11.07.2015 Views

Short Instruction EMB 7200.pdf - ferralux.ro

Short Instruction EMB 7200.pdf - ferralux.ro

Short Instruction EMB 7200.pdf - ferralux.ro

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Connection Options, Settings and Display Elements of Cont<strong>ro</strong>l Unit <st<strong>ro</strong>ng>EMB</st<strong>ro</strong>ng> 72001 off = locking function1 on = biased off(dead man) functionDrive line monitoring:2 off = yes2 on = noConnections:For drive line fault:3 off = no emergency on3 on = emergency on6,3 ATBack-up battery4 - basic attitude = off *)5 - basic attitude = off *)<st<strong>ro</strong>ng>EMB</st<strong>ro</strong>ng> 7200ON*) Note:Hence switch 4 and 5have to be in the off position !Exception: to setting theventilation functions (seeSETTING VENTILATIONCONTROLS)3Transformer(secondary)4 51 2OFFAdjustementof operating mode5 ATBack-up batteryPOw.PEG<strong>ro</strong>undS6,3 ATREL 65Ord.no. 650200Slot for plug-in cardREL 65fault signal1 AMLM1,25 ATNLSlot for plug-in cardREL 65signal”Emergency open”RESET/EM.CLOSE.EM OpStör.OperCLOPNTransformer(primary)0,615 AT 0,615 AT1 2 3 4 5 6 7 8 9 10 11 1213 14 15 1617 18 19 20 21 2223 24Mains powersupply230 V AC, 50 Hz230 VN LService boardOrd.no. 681010Slot forService ModuleIndicator (green): Power supplyIndicator (red): Ventilation openIndicator (green): Ventilation closeWarning: Cont<strong>ro</strong>l Circuits are Low DC Voltage up to 50 volts.Indicator (green): OperationIndicator (yellow): Fault “M”Indicator (yellow): Fault “Stör.”OPEN CLOSEIndicator (red): Fault “L”IndicatorsVentilation28 V, max. 0,2 AIndicator (red): EMERGENCY ONSwitch: Reset / EMERGENCY CLOSEResetting smoke detectorsOPEN CLOSE*Important NotesWind rain sensorset 70 / 71 / 72Ord.no. 482100+The RE resistor must remainin circuit within the last inline or only manual detector.Resistors must always beremoved f<strong>ro</strong>m intermediateunits.StopAll wiring must be carried out in accordancewith the National Regulations and guidelinies for electrical installations.Wind sensorVentilationCheck that all terminal connections andplug-in cards are secure.65 4 3 21Junction box+65 4 3 21<st<strong>ro</strong>ng>ferralux</st<strong>ro</strong>ng>®Rain sensorView on base (without indicators)b<strong>ro</strong>wnblueEach SHEV cont<strong>ro</strong>l unit <st<strong>ro</strong>ng>EMB</st<strong>ro</strong>ng> 7200has 2 detector lines:Line a: Terminal 15 -16 forbreakglass unitLine b: Terminal 17/18 forautomatic detectionOKSHEV Drives Junction boxOKb<strong>ro</strong>wn+blue10 k resistors are p<strong>ro</strong>vided foreach detector line. When a lineis not used leave the resistorconnected in the terminal block.When detector lines are usedend of line resistors must be incircuit. Refer to connectiondetails of breakglass units andautomatic detectors.SETTINGVENTILATIONCONTROLS:65 4 3 2110 kOrd.no. 528691 up to 528695G<strong>ro</strong>und FloorDrive end linemodule 70 MIf one drive operates in the w<strong>ro</strong>ngdirection interchange the leadsb<strong>ro</strong>wn / blue. If all drives operate inthe w<strong>ro</strong>ng direction, interchange theleads panel terminal 1/2.Note the current operationalsetting of DIP 1,2 and 3.Then set DIP switches 3 and4 to on and 1,2 and 5 to off.For setting the wind sensor:Set a value between 2 and10 m/s (0 = deactivated).For setting a drive operationtime:Set a value between 2 and100 s. (0 = deactivated)For setting an automaticCLOSE:Set a value between 2 and120 minutes (0 = deactivated)Finally, briefly set DIP switch 5to on, then turn it back to off.Now set DIP switch 4 back tooff and 1, 2 and 3 to the previouslynoted position. Check thesettings and function; repeatp<strong>ro</strong>cedure if necessary.All three ventilation functionscan be operated together.Ensure end of line resistor isconnected within circuit at thelast in line or only detector.Upper FloorOrd.no. 528691 up to 5286951 2 3 4 5 6 7 8 9 10 11Optical smoke detectorREA drive end line module 70 Mmust be installed within circuitat the last in line or only drive.rt gn geDRIVESEMERGENCYIf drive end module 70 M is notconnected correctly a fault indicationwill occur within app<strong>ro</strong>x. 5 seconds.OPENCLOSEO.K.FaultEMERGENCYOPENOrd.no. 513533SwitchesIndicatorsAUTOMATICDETECTORSBreakglass UnitsFault types indication with indicator “Stör.”, “M” and “L”:Line bMANUAL DETECTORSLine aWind & rain operational indication:Operational of “Zu/Cl.” “M” “L” “Betr./Oper.”Wind on on off onRain on off on onWind and rain on on on onFault types “Stör./ Fault” “M” “L” PriorityNo power supplyl very quick flash off off 1Breakage line a on flash on 2<st<strong>ro</strong>ng>Short</st<strong>ro</strong>ng> circuit line a on flash flash 3Breakage line b on quick flash on 4<st<strong>ro</strong>ng>Short</st<strong>ro</strong>ng> circuit line b on quick flash flash 5Drive line on on off 6Emergency closed quick flash off off 7Battery on off off 8This drawing must neither be rep<strong>ro</strong>duced nor handed over to a third party unless with the permission of the p<strong>ro</strong>ducer. The drawing is subject to technical changes.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!