Walls facing three sides>1.97 (50)inch (mm)>3.94 (100)>13.78 (350)7.4. Installation instructionsMounting the outdoor unitWhen installing the outdoor unit, please refer to "6. Precautions oninstallation location" on page 4 to select an appropriate location.1 Check the strength and level of the installation ground so thatthe unit will not cause any operating vibration or noise afterinstallation.6.5. Additional precautionsIt is recommended to install the equipment and electric wires keepingproper distances away from stereo equipment, personal computers,etc... In extreme circumstances you shall keep distances of 9.84 ft(3 m) or more and use conduit tubes for power and transmissionlines.■■■■■Do not install the unit in places often used as work place.In case of construction works (e.g. grinding works) where a lot ofdust is created, the unit must be covered.Do not place any objects or equipment on top of the unit (topplate).Do not climb, sit or stand on top of the unit,Be sure that sufficient precautions are taken, in accordance withthe applicable legislation, in case of refrigerant leakage.2 Prepare 4 sets of 0.31 inch [close to 5/16 inch] (M8) or 0.39 inch[close to 3/8 inch] (M10) foundation bolts, nuts and washerseach (field supply).3 Fix the unit securely by means of the foundation bolts inaccordance with the figure below.It is best to screw in the foundation bolts until their lengthremains 0.79 inch (20 mm) above the foundation surface.Outdoor installation drawingunit: inch (mm)0.79 inch(20 mm)17. <strong>INSTALLATION</strong> OF THE UNIT7.1. Unpacking the unitCheck if all unit accessories are enclosed.WARNINGTear apart and throw away plastic packaging bags so thatchildren will not play with them. Children playing withplastic bags face danger of death by suffocation.7.2. InspectionAt delivery, the unit must be checked and any damage must bereported immediately to the carrier's claims agent.327.3. Handling the unitAs shown in the figure below, bring the unit slowly by grabbing the leftand right grips.612.99 (330)22.83 (580) 4.72 (120)54Do not hold the suction inlet in the side of the casing, otherwise thecasing could be deformed.CAUTIONTo avoid injury, do not touch the air inlet or aluminium finsof the unit.1 Wrap the insulation pipe with finishing tape from bottom to top.2 Stop valve cover3 9.84 inch (250 mm) from wall. Allow space for piping and electricalservicing.4 If there is danger of the unit falling or overturning, fix the unit withfoundation bolts, or with wire or other means.5 Distance from the outer side of the stop valve cover6 If the location does not have good drainage, place the unit onblock bases. Adjust foot height until the unit is levelled. Failure todo so may result in water leakage or accumulation.ERLQ018~030BAVJUOutdoor unit for air to water heat pump4PW62590-1 – 07.2010Installation manual6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!