21.01.2015 Views

Descargar en .pdf (16,6 Mb) - CCTV Center

Descargar en .pdf (16,6 Mb) - CCTV Center

Descargar en .pdf (16,6 Mb) - CCTV Center

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R<br />

Expansión<br />

Ajustar<br />

Servidor Conectado<br />

10<br />

Enlace Servidor<br />

100<br />

10/100 Ethernet<br />

C<strong>en</strong>tral de Alarma<br />

Terminación fin de línea<br />

ON<br />

OFF<br />

RS485 Red Local<br />

Codigo de cable CAT5<br />

Tx<br />

Rx<br />

12V<br />

Red LED<br />

Amber LED<br />

Gre<strong>en</strong> LED<br />

Data/D0<br />

Clock/D1<br />

Media Detect<br />

0V<br />

12V<br />

Red LED<br />

Amber LED<br />

Gre<strong>en</strong> LED<br />

Data/D0<br />

Clock/D1<br />

Media Detect<br />

0V<br />

O u<br />

n p u t s<br />

R e l a y<br />

e l a y<br />

u t t o<br />

x i<br />

C o n t a c<br />

/ T a m p e r<br />

Expansion<br />

Set<br />

Server Connected<br />

10<br />

Server Link 100<br />

10/100 Ethernet<br />

http://paxton.info/107<br />

LABEL 123456<br />

HERE<br />

00-01-02-03-04-05<br />

End of Line Termination<br />

ON<br />

OFF<br />

RS485 Network<br />

CAT5 Cable Coding<br />

Scre n<br />

Tx<br />

Rx<br />

1<br />

R elay<br />

xit<br />

12V<br />

0V<br />

0V<br />

N.C.<br />

N.O.<br />

COM<br />

N.C.<br />

N.O.<br />

COM<br />

Alarm<br />

12V<br />

Gre<strong>en</strong> LED<br />

Exit<br />

0V<br />

Contact<br />

0V<br />

0V<br />

Tamper<br />

PSU<br />

CONTROL DE ACCESOS<br />

Sistemas Paxton - Net2<br />

Unidades de control Net2<br />

Las unidades de control Net2 clásicas, plus y nano pued<strong>en</strong><br />

combinarse librem<strong>en</strong>te d<strong>en</strong>tro de un mismo sistema Net2<br />

de forma que se puede elegir, <strong>en</strong> cada caso, el po de controlador<br />

que mejor se adapte a cada situación.<br />

Al igual que el resto de sistemas Paxton, las unidades de<br />

control son muy fáciles de conectar gracias al código de<br />

colores y a los rótulos que id<strong>en</strong>can todos los compon<strong>en</strong>tes.<br />

Además, los principales conectores dispon<strong>en</strong> de<br />

LEDs de estado para indicar el correcto funcionami<strong>en</strong>to de<br />

la unidad.<br />

A la hora de elegir un controlador asegúrese de que el modelo<br />

elegido <strong>en</strong>e conectores para el número de puertas<br />

y/o lectores requerido así como para el resto de compon<strong>en</strong>tes<br />

que desee instalar.<br />

Las unidades pued<strong>en</strong> suministrarse sin caja o con una variedad<br />

de carcasas, fu<strong>en</strong>tes de alim<strong>en</strong>tación y baterías.<br />

Lector 1<br />

Lector 2<br />

Unidad de control Net2 plus<br />

Conexión<br />

TCP/IP<br />

Pulsador<br />

salida<br />

Net2 plus<br />

Las unidades Net2 plus son más rápidas y dispon<strong>en</strong> de más memoria que el resto de controladores Net2. Además, dispon<strong>en</strong> de un<br />

conector RJ45 para conectarse directam<strong>en</strong>te a una red TCP/IP lo que permite reducir los costes de equipami<strong>en</strong>to y el empo de instalación<br />

sobre todo <strong>en</strong> proyectos <strong>en</strong> los que ya existe una red IP instalada.<br />

En situaciones <strong>en</strong> las que no existe un punto de red <strong>en</strong> el lugar elegido para instalar el controlador, las unidades Net2 plus pued<strong>en</strong><br />

actuar como conversores TCP/IP a RS-485. En estos casos, la unidad Net2 plus se conecta a la red TCP/IP y se cablea una línea RS-485<br />

hacia las unidades de control Net2 clásico o hacia otras unidades Net2 plus.<br />

12V<br />

Red LED<br />

Amber LED<br />

Gre<strong>en</strong> LED<br />

Data/D0<br />

Clock/D1<br />

Media Detect<br />

0V<br />

12V<br />

Red LED<br />

Amber LED<br />

Gre<strong>en</strong> LED<br />

Data/D0<br />

Clock/D1<br />

Media Detect<br />

0V<br />

Lector e a d e 1 r 1<br />

Lector R e a d e 2 r 2<br />

Expansion<br />

Precaución: C Solo para lecotres a 12VDC y<br />

a u t i o n :<br />

F o r 1 2 V D C r e a d e r s o n l<br />

N . O .<br />

Set<br />

Server Connected<br />

10<br />

Server Link 100<br />

C O M<br />

10/100 Ethernet<br />

S e n s e<br />

Intruder Alarm<br />

Net2 plus<br />

c a b l e<br />

End of Line T ermination<br />

ON<br />

OFF<br />

c o r e s f r o m d a t a<br />

A r m<br />

RS485 Network<br />

CA T5 Cable Coding<br />

S c r e e n o r s p a r e<br />

W h t / G r n<br />

0 V<br />

http://paxton.info/107 o/107<br />

12345612<br />

PLACE SERIAL<br />

NUMBER<br />

LABEL 123456<br />

HERE<br />

00-01-02-03-04-05<br />

Ma la o hilos sueltos<br />

del cable de red<br />

G r e e n<br />

W h t / O r n g<br />

O r a n g e<br />

I tputs<br />

r e w o P<br />

Entradas Salidas<br />

Alim<strong>en</strong>t<br />

C Pulsador E t B de salida n<br />

R Relé 1 2<br />

Relé 2 1<br />

PS<br />

SU/Tamper<br />

U<br />

ontac t<br />

12V<br />

0V<br />

0V<br />

N.C.<br />

N.O .<br />

COM<br />

N.C.<br />

N.O .<br />

COM<br />

Alarm<br />

12V<br />

Gre<strong>en</strong> LED<br />

Exit<br />

0V<br />

Contact<br />

0V<br />

0V<br />

T amper<br />

Conexión<br />

bus RS-485<br />

PSU<br />

Cerradura eléctrica<br />

Tamper<br />

antisabotaje<br />

Contacto<br />

magnético<br />

CONTROL DE ACCESOS<br />

0V<br />

Arm<br />

S<strong>en</strong>se<br />

COM<br />

N.O.<br />

Power<br />

Net2 plus<br />

Net2 plus<br />

Net2 clásica<br />

Reader 1<br />

C aution:<br />

y<br />

For 12V DC readers onl<br />

Reader 2<br />

Intruder Alarm<br />

Net2 plus<br />

1234561<br />

cores<br />

cable<br />

or spare<br />

from data<br />

Wht/Grn<br />

I nputs<br />

Output s<br />

Orange<br />

Wht/Orng<br />

Gre n<br />

Relay<br />

C ontac E Butto n<br />

2<br />

P SU/Tamper<br />

t<br />

PC Net2<br />

TCP/IP<br />

Net2 nano<br />

Las unidades Net2 nano no requier<strong>en</strong> cableado porque comunican con el PC Net2 a través de una conexión inalámbrica <strong>en</strong>criptada.<br />

Basta con conectar un receptor inalámbrico Bridge (directam<strong>en</strong>te al PC por USB o a cualquier punto de la red por Ethernet) y podrá<br />

comunicar con los controladores nano que se <strong>en</strong>cu<strong>en</strong>tr<strong>en</strong> <strong>en</strong> el rango de alcance. Si necesita ampliar la distancia de alcance o escalar<br />

el sistema podrá hacerlo fácilm<strong>en</strong>te añadi<strong>en</strong>do receptores Bridge adicionales.<br />

RS-485<br />

Conexión TCP/IP<br />

PC Net2<br />

Receptor inalámbrico<br />

Net2Air<br />

(conexión Ethernet)<br />

Net2 nano<br />

PC Net2<br />

Receptor inalámbrico<br />

Net2Air<br />

(conexión USB)<br />

Net2 nano Net2 nano Net2 nano<br />

Net2 PaxLock<br />

Los sistemas inalámbricos PaxLock integran una unidad de control y un lector de proximidad <strong>en</strong> una unidad con rador lista para ser<br />

instalada <strong>en</strong> una puerta cov<strong>en</strong>cional. Las unidades PaxLock ulizan tecnología inalámbrica segura Net2 Air y comunican con el PC Net2<br />

a través de un receptor inalámbrico Net2 Air del mismo modo que las unidades de control Net2 nano.<br />

PC Net2<br />

Receptor<br />

Net2 Air<br />

Unidades inalámbricas PaxLock<br />

www.cctvc<strong>en</strong>tersl.es<br />

149

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!