<strong>AirCon</strong> <strong>Service</strong> Center<br />

<strong>Service</strong> tasks<br />

I<br />

NOTE<br />

6. Once the oil has been completely drained from the pump housing,<br />

screw the oil drain plug (J) back in.<br />

7. Top up with new vacuum pump oil to the middle of the sight glass (H)<br />

and screw the oil filling plug (G) back in.<br />

8. Put the front panel and control panel back on and reconnect the power<br />

plug.<br />

After finishing the service tasks, you must delete the respective service<br />

messages (counter reset). To do this, switch to the “Other selections” –<br />

“<strong>Service</strong>” menu and enter the code “7782”. Use the cursor keys or to<br />

select the required entry and press ENTER to confirm. Follow the display<br />

instructions, and press and hold the ENTER button for 3 seconds. Switch<br />

back to the previous selection using STOP.<br />

When changing the vacuum pump oil, the counter “Vacuum time” must be<br />

reset.<br />

R134a from system<br />

07/09/10<br />

g. 1455<br />

STOP-EXIT<br />

“R134a from system” indicates how many grams of refrigerant have been<br />

extracted from air conditioning systems using the menu item “Short<br />

selection” or “Free selection” since the last reset (see date).<br />

R134a from tank<br />

07/09/10<br />

g. 3395<br />

STOP-EXIT<br />

“R134a from tank” indicates how many grams of refrigerant were added<br />

to the device using the menu item “Int. vessel filling” since the last reset<br />

(see date).<br />

R134a to system<br />

07/09/10<br />

g. 1200<br />

STOP-EXIT<br />

“R134a to system” indicates how many grams of refrigerant have been<br />

filled into air conditioning systems using the menu item “Short selection”<br />

or “Free selection” since the last reset (see date).<br />