<strong>AirCon</strong> <strong>Service</strong> Center<br />
<strong>Service</strong> tasks<br />
I<br />
NOTE<br />
6. Once the oil has been completely drained from the pump housing,<br />
screw the oil drain plug (J) back in.<br />
7. Top up with new vacuum pump oil to the middle of the sight glass (H)<br />
and screw the oil filling plug (G) back in.<br />
8. Put the front panel and control panel back on and reconnect the power<br />
plug.<br />
After finishing the service tasks, you must delete the respective service<br />
messages (counter reset). To do this, switch to the “Other selections” –<br />
“<strong>Service</strong>” menu and enter the code “7782”. Use the cursor keys or to<br />
select the required entry and press ENTER to confirm. Follow the display<br />
instructions, and press and hold the ENTER button for 3 seconds. Switch<br />
back to the previous selection using STOP.<br />
When changing the vacuum pump oil, the counter “Vacuum time” must be<br />
reset.<br />
R134a from system<br />
07/09/10<br />
g. 1455<br />
STOP-EXIT<br />
“R134a from system” indicates how many grams of refrigerant have been<br />
extracted from air conditioning systems using the menu item “Short<br />
selection” or “Free selection” since the last reset (see date).<br />
R134a from tank<br />
07/09/10<br />
g. 3395<br />
STOP-EXIT<br />
“R134a from tank” indicates how many grams of refrigerant were added<br />
to the device using the menu item “Int. vessel filling” since the last reset<br />
(see date).<br />
R134a to system<br />
07/09/10<br />
g. 1200<br />
STOP-EXIT<br />
“R134a to system” indicates how many grams of refrigerant have been<br />
filled into air conditioning systems using the menu item “Short selection”<br />
or “Free selection” since the last reset (see date).<br />