Operation<br />
<strong>AirCon</strong> <strong>Service</strong> Center<br />
8.6.3 Filling process<br />
1. Enter the preferred settings and press ENTER to confirm.<br />
Filling<br />
phase?<br />
Yes<br />
No<br />
I<br />
NOTE<br />
2. If “Filling phase” has been selected, enter the required value,<br />
otherwise continue with “Select connections”.<br />
3. Enter the refrigerant oil quantity.<br />
4. Press the cursor key .<br />
5. Enter the additive quantity.<br />
6. Press the cursor key .<br />
7. Enter the refrigerant quantity.<br />
8. Press ENTER to confirm all settings.<br />
• If extraction is taking place in the same process sequence, the quantity of<br />
fresh oil is counted as an additional filling quantity, and is added to the<br />
drained oil quantity extracted beforehand. If this value is set to 0, exactly<br />
the quantity of oil which was extracted will be filled again.<br />
• To add fresh oil or UV additive, a vacuum process must be performed in<br />
the same process sequence. If no vacuum process has been selected,<br />
only refrigerant can be selected in the filling menu.<br />
8.6.4 Selecting connections<br />
ENTER-OK STOP-EXIT<br />
PAG oil ml. 1<br />
UV tracer ml. 7<br />
Refrigerant g. 500<br />
ENTER-OK STOP-EXIT<br />
1. Select the parameters in accordance with the air conditioning system<br />
connections:<br />
• Air conditioning system has a high pressure and a low pressure<br />
connection: Select LP / HP.<br />
• Air conditioning system only has a high pressure connection:<br />
Select HP.<br />
• Air conditioning system only has a low pressure connection:<br />
Select LP.<br />