Operation AirCon Service Center 8. Enter the vehicle data (model, type) in the blank field and press ENTER to confirm. ____________ 0 ___________________ ____________ g. ___ 0 9. Enter the refrigerant quantity and press ENTER to confirm. AUDI 0 A4 (8E) 2000 - 2004 g. 500 I NOTE The entry has been created. AUDI 0 A4 (8E) 1 You can now create another entry (use the cursor keys to select and proceed as described) or press “STOP” to exit the menu. The personal entries are saved in the control board, not on the flash memory card.The entries will be retained even after updating the software. The entries are stored chronologically (not alphanumerically). 8.4 Refrigerant consumption display The station saves the data on the amount of refrigerant filled and extracted. You can print out this data as an annual or monthly overview. 1. In the basic menu, use the cursor keys or to select “Other selections”: Short selection Free selection Other selections ENTER-OK 2. Press ENTER to confirm. 3. Use the cursor key to select “Service” and press ENTER to confirm: Flushing Reset scales. Service. ENTER-OK STOP-EXIT 80 EN
AirCon Service Center Operation 4. Enter the password “9051” and press ENTER to confirm. Service. ---- 5. Use the cursor keys or to select the year and press ENTER to confirm: 2010 I NOTE Example: “R134a from system” shows the quantity of refrigerant extracted. A total of 18,650 g of refrigerant was extracted by the station in 2010 in this example. Use the cursor key to move to the next total amount of filling refrigerant for the corresponding year: Press the cursor key R134a from system Total 2010 g. 18650 PRINT STOP-EXIT R134a to system Total 2010 g. 9000 PRINT STOP-EXIT to view the display for the monthly overview: R134a from system 01/2010 g. 2400 PRINT STOP-EXIT A total of 2,400 g of refrigerant was extracted in January 2010 in this example. In the monthly overview, the filled and extracted amount is always displayed alternately. Press “ENTER” to print out the overview at any time. Press “STOP” to exit the overview. EN 81
- Page 30 and 31: Betrieb AirCon Service Center I HIN
- Page 32 and 33: Betrieb AirCon Service Center 8.6.1
- Page 34 and 35: Betrieb AirCon Service Center 3. We
- Page 36 and 37: Betrieb AirCon Service Center 17. M
- Page 38 and 39: Servicearbeiten AirCon Service Cent
- Page 40 and 41: Servicearbeiten AirCon Service Cent
- Page 42 and 43: Servicearbeiten AirCon Service Cent
- Page 44 and 45: Servicearbeiten AirCon Service Cent
- Page 46 and 47: Servicearbeiten AirCon Service Cent
- Page 48 and 49: Servicearbeiten AirCon Service Cent
- Page 50 and 51: Servicearbeiten AirCon Service Cent
- Page 52 and 53: Entsorgung AirCon Service Center 10
- Page 54 and 55: Was tun, wenn? AirCon Service Cente
- Page 56 and 57: Contents AirCon Service Center 1 Ab
- Page 58 and 59: About this operating manual AirCon
- Page 60 and 61: Safety AirCon Service Center Each t
- Page 62 and 63: Optional extras AirCon Service Cent
- Page 64 and 65: Overview of the AirConServiceCenter
- Page 66 and 67: Initial start-up AirCon Service Cen
- Page 68 and 69: Initial start-up AirCon Service Cen
- Page 70 and 71: Initial start-up AirCon Service Cen
- Page 72 and 73: Initial start-up AirCon Service Cen
- Page 74 and 75: Operation AirCon Service Center 8 O
- Page 76 and 77: Operation AirCon Service Center 8.2
- Page 78 and 79: Operation AirCon Service Center 8.2
- Page 82 and 83: Operation AirCon Service Center 8.5
- Page 84 and 85: Operation AirCon Service Center 8.6
- Page 86 and 87: Operation AirCon Service Center 8.6
- Page 88 and 89: Operation AirCon Service Center 3.
- Page 90 and 91: Service tasks AirCon Service Center
- Page 92 and 93: Service tasks AirCon Service Center
- Page 94 and 95: Service tasks AirCon Service Center
- Page 96 and 97: Service tasks AirCon Service Center
- Page 98 and 99: Service tasks AirCon Service Center
- Page 100 and 101: Service tasks AirCon Service Center
- Page 102 and 103: Service tasks AirCon Service Center
- Page 104 and 105: Service tasks AirCon Service Center
- Page 106 and 107: Troubleshooting AirCon Service Cent
- Page 108 and 109: Technical data AirCon Service Cente
- Page 110 and 111: Acerca de estas instrucciones de us
- Page 112 and 113: Seguridad AirCon Service Center 2 S
- Page 114 and 115: Volumen de entrega AirCon Service C
- Page 116 and 117: Vista general del AirConServiceCent
- Page 118 and 119: Primera puesta en funcionamiento Ai
- Page 120 and 121: Primera puesta en funcionamiento Ai
- Page 122 and 123: Primera puesta en funcionamiento Ai
- Page 124 and 125: Primera puesta en funcionamiento Ai
- Page 126 and 127: Primera puesta en funcionamiento Ai
- Page 128 and 129: Funcionamiento AirCon Service Cente
Operation<br />
<strong>AirCon</strong> <strong>Service</strong> Center<br />
8. Enter the vehicle data (model, type) in the blank field and press<br />
ENTER to confirm.<br />
____________ 0<br />
___________________<br />
____________ g. ___ 0<br />
9. Enter the refrigerant quantity and press ENTER to confirm.<br />
AUDI 0<br />
A4 (8E)<br />
2000 - 2004 g. 500<br />
I<br />
NOTE<br />
The entry has been created.<br />
AUDI 0<br />
A4 (8E)<br />
1<br />
You can now create another entry (use the cursor keys to select and<br />
proceed as described) or press “STOP” to exit the menu.<br />
The personal entries are saved in the control board, not on the flash memory<br />
card.The entries will be retained even after updating the software.<br />
The entries are stored chronologically (not alphanumerically).<br />
8.4 Refrigerant consumption display<br />
The station saves the data on the amount of refrigerant filled and<br />
extracted. You can print out this data as an annual or monthly overview.<br />
1. In the basic menu, use the cursor keys or to select “Other<br />
selections”:<br />
Short selection<br />
Free selection<br />
Other selections<br />
ENTER-OK<br />
2. Press ENTER to confirm.<br />
3. Use the cursor key to select “<strong>Service</strong>” and press ENTER to<br />
confirm:<br />
Flushing<br />
Reset scales.<br />
<strong>Service</strong>.<br />
ENTER-OK STOP-EXIT<br />
80<br />
EN