Technical data<br />

<strong>AirCon</strong> <strong>Service</strong> Center<br />

Problem Cause Remedy<br />

The display shows<br />

“Error 10”<br />

The display shows<br />

“Error 11”<br />

The display shows<br />

“Error 12”<br />

It was not possible to reduce<br />

the pressure sufficiently<br />

during the "Software test".<br />

It was not possible to drain<br />

any used oil during the<br />

"Software test".<br />

It was not possible to remove<br />

any refrigerant from the<br />

internal tank during the<br />

"Software test".<br />

Residual pressure on the<br />

pressure gauges? Check<br />

pressure transducer<br />

calibration. Check internal<br />

bottle pressure. Check the<br />

compressor and the<br />

corresponding solenoid<br />

valves.<br />

Insert receptacle for drained<br />

oil correctly. Check that the<br />

solenoid valve can move<br />

freely. Check that the scale is<br />

working properly.<br />

Check pressure transducer<br />

calibration.<br />

Check if the valve on the<br />

internal tank is open. Check<br />

the RE valve.<br />

12 Technical data<br />

<strong>ASC2500</strong> <strong>AirCon</strong> <strong>Service</strong> Center ASC 2500<br />

Item number: 8885200095<br />

Dimensions (width x height x depth):<br />

560 mm x 1300 mm x 650 mm<br />

Weight:<br />

100 kg<br />

Power supply:<br />

230 V/240 V – 50 Hz/60 Hz<br />

Refrigerant extraction rate:<br />

30 kg / h<br />

Vacuum pump output:<br />

5 cars / h<br />

Hermetic compressor output:<br />

0.32 kW<br />

Drier filter output:<br />

150 kg<br />

Filling cylinder accumulator capacity:<br />

16 kg<br />

Noise emission:<br />

55.5 dB (A)<br />

Accuracy of the electronic scale for refrigerant:<br />

± 10 g<br />

Accuracy of the electronic scale for old/new oil:<br />

± 1 g<br />

Accuracy of the electronic scale for UV additive: ± 1 g<br />

Operating temperature range: + 5 °C to + 50 °C<br />