Service tasks AirCon Service Center 3. Replace the drained oil receptacle (O) and the O-ring (P). O P 4. When replacing the cover (N), ensure that the lug (Q) is positioned correctly. N Q 5. Clip the drained oil receptacle into the snap lock. 9.11 Cleaning and maintenance • Clean the exterior of the device with a damp cloth as required. If necessary, use a small amount of dishwashing detergent. Do not use solvents or scouring agents. • Check the service hoses (10) and (11) and the service couplings (12) and (13) for damage regularly. Do not start up the AirConServiceCenter if it is damaged. 104 EN

AirCon Service Center Disposal 10 Disposal 10.1 Disposing of used fluids I NOTE Used oil is hazardous waste. Do not mix used oil with other fluids. Keep used oil in suitable containers prior to disposal. 10.2 Disposing of packaging material • The cardboard packaging material should be disposed of with other waste paper. • Plastic packaging material should be added to other recyclable waste. 10.3 Scrapping the old unit • If you wish to scrap the AirConServiceCenter, first completely drain it of all liquids and dispose of them in an environmentally responsible manner. • Take the old device to your nearest recycling centre or contact the customer service. EN 105

<strong>Service</strong> tasks<br />

<strong>AirCon</strong> <strong>Service</strong> Center<br />

3. Replace the drained oil receptacle (O) and the O-ring (P).<br />

O<br />

P<br />

4. When replacing the cover (N), ensure that the lug (Q) is positioned<br />

correctly.<br />

N<br />

Q<br />

5. Clip the drained oil receptacle into the snap lock.<br />

9.11 Cleaning and maintenance<br />

• Clean the exterior of the device with a damp cloth as required. If<br />

necessary, use a small amount of dishwashing detergent. Do not use<br />

solvents or scouring agents.<br />

• Check the service hoses (10) and (11) and the service couplings (12)<br />

and (13) for damage regularly. Do not start up the <strong><strong>AirCon</strong><strong>Service</strong>Center</strong><br />