<strong>Service</strong> tasks<br />

<strong>AirCon</strong> <strong>Service</strong> Center<br />

9.7 Correcting the filling quantity for long service<br />

hoses<br />

I<br />

NOTE<br />

• If longer or shorter service hoses are required for the device, you need to<br />

adjust the filling quantities to the new hose lengths.<br />

• The service hoses for the high and low pressure sides must always be of<br />

the same length, as otherwise the filling quantities will not be correctly<br />

measured.<br />

1. In the basic menu, use the cursor keys or to select “Other<br />

selections”:<br />

Short selection<br />

Free selection<br />

Other selections<br />

ENTER-OK<br />

2. Press ENTER to confirm.<br />

3. Use the cursor keys or to select “<strong>Service</strong>”:<br />

Int. vessel filling<br />

Flushing<br />

Reset scales.<br />

<strong>Service</strong>.<br />

4. Press ENTER to confirm.<br />

5. Enter the password “7732”.<br />

6. Enter the hose length in centimetres.<br />

7. Press ENTER to confirm.<br />

100<br />