Use this section to copy Grafica sections [001] to [004], all zone labels, area labels and user labels to the Memory Key. Only the Memory Key will function with Grafica keypads. 1. Insert the Memory Key into the keypad’s connector (Figure 9 on page 39). Ensure that the Memory Key’s jumper is ON (Figure 10 on page 40). 2. To copy the contents to the Memory Key, enter the keypad’s programming mode (section 4.1 on page 5) and enter section [110] in step 5. 3. After the confirmation beep, wait five seconds and remove the Memory Key after the second confirmation beep. After copying data, set the jumper to OFF to avoid accidentally overwriting its contents (Figure 10 on page 40). 6.3 Updating Grafica’s Firmware Version Update Grafica’s firmware version, without physically changing the microprocessor, by using the Universal In-Field Programmer (UIP-256). Connect the Universal In-Field Programmer to Grafica (Figure 9 on page 39) and refer to the Universal In-Field Programmer Instructions to update Grafica’s firmware version. 7.0 Programming Sections = Default Setting Section [001]: Keypad Partition Assignment Option OFF ON [1] PARTITION 1 DISABLED ENABLED [2] PARTITION 2 DISABLED ENABLED [3] PARTITION 3 DISABLED ENABLED [4] PARTITION 4 DISABLED ENABLED [5] PARTITION 5 DISABLED ENABLED [6] PARTITION 6 DISABLED ENABLED [7] PARTITION 7 DISABLED ENABLED [8] PARTITION 8 DISABLED ENABLED 10 Reference & Installation Manual
= Default Setting Section [002]: General Options 1 Option OFF ON [1] DISPLAY CODE ENTRY DISABLED ENABLED [2] DISPLAY EXIT DELAY DISABLED ENABLED [3] DISPLAY ENTRY DELAY DISABLED ENABLED [4] CONFIDENTIAL MODE DISABLED ENABLED [5] TO EXIT CONFIDENTIAL MODE * ENTER CODE PRESS KEY [6] EXIT DELAY BEEP DISABLED ENABLED [7] KEYPAD INPUT TYPE TEMP. SENSOR ZONE [8] KEYPAD TAMPER DISABLED ENABLED * Must be enabled through Option [4] in section [002] first. = Default Setting Section [003]: Beep on Trouble Option OFF ON [1] SYSTEM & CLOCK TROUBLE BEEP DISABLED ENABLED [2] COMMUNICATOR TROUBLE BEEP DISABLED ENABLED [3] MODULE & COMBUS TROUBLE BEEP DISABLED ENABLED [4] ALL ZONE TROUBLE BEEP DISABLED ENABLED [5] FUTURE USE N/A N/A [6] FUTURE USE N/A N/A [7] FUTURE USE N/A N/A [8] FUTURE USE N/A N/A Default Setting: 120 seconds Section [004]: Confidential Mode Timer Data ___/___/___ (005 to 255 seconds) Section [005]: Outside Temperature Calibration Data ___/___/___ (001 to 254; 000 and 128 = no calibration value) Section [006]: Inside Temperature Calibration Data ___/___/___ (001 to 254; 000 and 128 = no calibration value) Reference & Installation Manual 11
- Page 1: V1.4 DNE-K07 Reference and Installa
- Page 4 and 5: English Instructions (P. 2 - 12) Gr
- Page 6 and 7: 3.2 Keypad Cover Clearance Grafica
- Page 8 and 9: 4.2.3 Hexadecimal Programming Some
- Page 10 and 11: Option [7] OFF = Temperature sensor
- Page 14 and 15: Section [100]: Download From Memory
- Page 16 and 17: Interruptor Antisabotaje: Pantalla:
- Page 18 and 19: 4.0 Programación Gráfica es progr
- Page 20 and 21: Opción [3] OFF = No se muestra el
- Page 22 and 23: 5.10 Tiempo de Modo Confidencial SE
- Page 24 and 25: = Valor De Fábrica Sección [002]:
- Page 26 and 27: Instructions en Français (P. 24 -
- Page 28 and 29: 3.0 Installation 3.1 Angle de prise
- Page 30 and 31: Pour repérer le numéro de série
- Page 32 and 33: Le Grafica passe du mode confidenti
- Page 34 and 35: secondes (par défaut : 120 seconde
- Page 36 and 37: [2] AFFICHAGE DU DÉLAI DE SORTIE H
- Page 38 and 39: Figure / Figura 3 - Built-in Temper
- Page 40 and 41: Figure / Figura 6 A A Clip A Figure
- Page 42 and 43: A Figure / Figura 10 B A - When jum
- Page 44: For technical support in Canada or
= Default Setting<br />
Section [002]: General Options 1<br />
Option OFF ON<br />
[1] DISPLAY CODE ENTRY DISABLED ENABLED<br />
[2] DISPLAY EXIT DELAY DISABLED ENABLED<br />
[3] DISPLAY ENTRY DELAY DISABLED ENABLED<br />
[4] CONFIDENTIAL MODE DISABLED ENABLED<br />
[5] TO EXIT CONFIDENTIAL MODE * ENTER CODE PRESS KEY<br />
[6] EXIT DELAY BEEP DISABLED ENABLED<br />
[7] KEYPAD INPUT TYPE TEMP. SENSOR ZONE<br />
[8] KEYPAD TAMPER DISABLED ENABLED<br />
* Must be enabled through Option [4] in section [002] first.<br />
= Default Setting<br />
Section [003]: Beep on Trouble<br />
Option OFF ON<br />
[1] SYSTEM & CLOCK TROUBLE BEEP DISABLED ENABLED<br />
[2] COMMUNICATOR TROUBLE BEEP DISABLED ENABLED<br />
[3] MODULE & COMBUS TROUBLE BEEP DISABLED ENABLED<br />
[4] ALL ZONE TROUBLE BEEP DISABLED ENABLED<br />
[5] FUTURE USE N/A N/A<br />
[6] FUTURE USE N/A N/A<br />
[7] FUTURE USE N/A N/A<br />
[8] FUTURE USE N/A N/A<br />
Default Setting: 120 seconds<br />
Section [004]: Confidential Mode Timer<br />
Data ___/___/___ (005 to 255 seconds)<br />
Section [005]: Outside Temperature Calibration<br />
Data ___/___/___ (001 to 254; 000 <strong>and</strong> 128 = no calibration value)<br />
Section [006]: Inside Temperature Calibration<br />
Data ___/___/___ (001 to 254; 000 <strong>and</strong> 128 = no calibration value)<br />
<strong>Reference</strong> & <strong>Installation</strong> <strong>Manual</strong> 11