The functions of the two indicator lights and the signal relay are<br />

as shown in the following table:<br />

Indicator lights Signal relay activated during:<br />

Fault<br />

(red)<br />

Operation<br />

(green)<br />

Fault/Alarm,<br />

Warning and<br />

Relubricate<br />

Operating Ready<br />

Resetting of fault indication<br />

A fault indication can be reset in one of the following ways:<br />

• Briefly press the button or on the pump. This will not<br />

change the setting of the pump.<br />

A fault indication cannot be reset by means of<br />

buttons have been locked.<br />

or if the<br />

• Switch off the electricity supply until the indicator lights are off.<br />

• Switch the external start/stop input off and then on again.<br />

• Use the R100, see section 9.1.3 Fault indications.<br />

When the R100 communicates with the pump, the red indicator<br />

light will flash rapidly.<br />

Pump<br />

running<br />

Description<br />

Off Off The electricity supply has been switched off.<br />

Off<br />

Permanently<br />

on<br />

The pump is operating<br />

Off Flashing The pump has been set to stop.<br />

Permanently<br />

on<br />

Permanently<br />

on<br />

Permanently<br />

on<br />

Off<br />

Permanently<br />

on<br />

Flashing<br />

C NO NC C NO NC C NO NC C NO NC<br />

C NO NC<br />

C NO NC C NO NC C NO NC<br />

C NO NC C NO NC C NO NC C NO NC<br />

C NO NC C NO NC C NO NC C NO NC<br />

C NO NC C NO NC C NO NC C NO NC<br />

C NO NC C NO NC C NO NC C NO NC<br />

17. Insulation resistance<br />

Caution<br />

Caution<br />

The pump has stopped because of a Fault/<br />

Alarm or is running with a Warning or<br />

Relubricate indication.<br />

If the pump was stopped, restarting will be<br />

attempted (it may be necessary to restart the<br />

pump by resetting the Fault indication).<br />

The pump is operating, but it has or has had<br />

a Fault/Alarm allowing the pump to continue<br />

operation or it is operating with a Warning or<br />

Relubricate indication.<br />

If the cause is “sensor signal outside signal<br />

range”, the pump will continue operating<br />

according to the max. curve and the fault<br />

indication cannot be reset until the signal is<br />

inside the signal range.<br />

If the cause is “setpoint signal outside signal<br />

range”, the pump will continue operating<br />

according to the min. curve and the fault<br />

indication cannot be reset until the signal is<br />

inside the signal range.<br />

The pump has been set to stop, but it has<br />

been stopped because of a Fault.<br />

0.37-7.5 kW<br />

Do not measure the insulation resistance of<br />

motor windings or an installation incorporating<br />

E-pumps using high voltage megging equipment,<br />

as this may damage the built-in electronics.<br />

11-22 kW<br />

Do not measure the insulation resistance of an<br />

installation incorporating E-pumps using high<br />

voltage megging equipment, as this may damage<br />

the built-in electronics.<br />

The motor conductors can be disconnected<br />

separately and the insulation resistance of the<br />

motor windings can be tested.<br />

29