Group 4: Communication cable (8-pin male socket) - only<br />

<strong>TPE</strong>D<br />

The communication cable is connected to the socket in group<br />

4. The cable ensures communication between the two pumps,<br />

whether one or two pressure sensors are connected, see<br />

section 5.6 Communication cable for <strong>TPE</strong>D pumps.<br />

The selector switch in group 4 enables changeover between<br />

the operating modes “alternating operation” and “standby<br />

operation”. See description in section 6.2.1 Additional<br />

operating modes – <strong>TPE</strong>D pumps.<br />

14<br />

Group 2<br />

1: Digital input<br />

9: GND (frame)<br />

8: + 24 V<br />

7: Sensor input<br />

B: RS-485B<br />

Y: Screen<br />

A: RS-485A<br />

6: GND (frame)<br />

5: + 10 V<br />

4: Setpoint input<br />

3: GND (frame)<br />

2: Start/stop<br />

Fig. 14 Connection terminals <strong>TPE</strong> <strong>Series</strong> <strong>2000</strong><br />

Group 3<br />

Group 1<br />

TM03 8608 2007<br />

Group 2 Group 4 Group 3<br />

1: Digital input<br />

9: GND (frame)<br />

8: + 24 V<br />

7: Sensor input<br />

B: RS-485B<br />

Y: Screen<br />

A: RS-485A<br />

6: GND (frame)<br />

5: + 10 V<br />

4: Setpoint input<br />

3: GND (frame)<br />

2: Start/stop<br />

Fig. 15 Connection terminals <strong>TPE</strong>D <strong>Series</strong> <strong>2000</strong><br />

Group 1<br />

A galvanic separation must fulfil the requirements for reinforced<br />

insulation including creepage distances and clearances specified<br />

in EN 61800-5-1.<br />

TM03 9134 3407