HeartStart XL Instructions for Use and Service Manual Addendum This addendum provides updates to HeartStart XL Instructions for Use Edition 7, publication M4735-91900 and HeartStart XL Service Manual Edition 6, publication M4735-90900. Defibrillator Charge Time The charge time to 200 Joules with a new, fully charged M3516A SLA battery at 25°C is less than 3.5 seconds. Delivered Energy Accuracy Delivered Energy Accuracy for some energies has changed from absolute to percentage values. For Selected Energies of 20 J and 30 J, all load impedance values, the Accuracy values are ± 15%. Disposable Internal Paddles The following disposable internal paddles have been discontinued: 989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171. SpO 2 Sensors The M1903B and M1904B SpO 2 sensors have been discontinued. New sensors M1191B, M1191BL, M1192T, M1196A, and M1196T are available. The SpO 2 sensors characteristics are: Sensor Type Patient Type Patient Weight 1 Ideal Placement Cable Length Accuracy* M1191A M1191AL Adult > 50 kg Finger 200 cm 300 cm ± 2.5% M1191B M1191BL Adult, Large Adult > 50 kg Finger 200 cm 300 cm ± 2.5% M1192A M1192T Reusable Small adult, Pediatric 15 -50 kg 150 cm 45 cm ± 3.0% M1194A Pediatric, Adult Ear lobe 150 cm ± 4.0% M1196A M1196T Adult > 40 kg Finger 300 cm 35 cm ± 3.0% M1131A Disposable Pediatric, Adult > 20 kg 45 cm * With 1 standard deviation 70% to 100%. In other words, pulse oximeter equipment measurements are statistically distributed, therefore only about two-thirds of pulse oximeter equipment measurements can be expected to fall within ± Arms of the value measured by a CO-oximeter. The HeartStart XL is calibrated to display functional oxygen saturation.
- Page 2 and 3: HeartStart XL Addendum bij de Gebru
- Page 4 and 5: Addendum delle Istruzioni per l'uso
- Page 6 and 7: Anexo a las Instrucciones de uso y
- Page 8 and 9: HeartStart XL -käyttöohjeen ja -h
- Page 10 and 11: Tillägg till bruksanvisningen och
- Page 12 and 13: Συμπλήρωμα στις Οδ
- Page 14 and 15: Dodatek do Instrukcji obsługi i in
- Page 16 and 17: Приложение к инстр
- Page 18 and 19: HeartStart XL Kullanım Talimatlar
- Page 20 and 21: HeartStart XL 使用說明與服務
- Page 22: Philips Healthcare 3000 Minuteman R
<strong>HeartStart</strong> <strong>XL</strong> Instructions for Use and Service Manual Addendum<br />
This addendum provides updates to <strong>HeartStart</strong> <strong>XL</strong> Instructions for Use Edition 7, publication M4735-91900 and<br />
<strong>HeartStart</strong> <strong>XL</strong> Service Manual Edition 6, publication M4735-90900.<br />
Defibrillator Charge Time<br />
The charge time to 200 Joules with a new, fully charged M3516A SLA battery at 25°C is less than 3.5 seconds.<br />
Delivered Energy Accuracy<br />
Delivered Energy Accuracy for some energies has changed from absolute to percentage values. For Selected Energies of<br />
20 J and 30 J, all load impedance values, the Accuracy values are ± 15%.<br />
Disposable Internal Paddles<br />
The following disposable internal paddles have been discontinued: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 Sensors<br />
The M1903B and M1904B SpO 2 sensors have been discontinued. New sensors M1191B, M1191BL, M1192T,<br />
M1196A, and M1196T are available. The SpO 2 sensors characteristics are:<br />
Sensor Type Patient Type Patient<br />
Weight<br />
1<br />
Ideal<br />
Placement<br />
Cable<br />
Length<br />
Accuracy*<br />
M1191A<br />
M1191AL<br />
Adult > 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2.5%<br />
M1191B<br />
M1191BL<br />
Adult,<br />
Large Adult<br />
> 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2.5%<br />
M1192A<br />
M1192T<br />
Reusable Small adult,<br />
Pediatric<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3.0%<br />
M1194A Pediatric, Adult<br />
Ear lobe 150 cm ± 4.0%<br />
M1196A<br />
M1196T<br />
Adult<br />
> 40 kg<br />
Finger<br />
300 cm<br />
35 cm ± 3.0%<br />
M1131A Disposable Pediatric, Adult > 20 kg 45 cm<br />
* With 1 standard deviation 70% to 100%. In other words, pulse oximeter equipment<br />
measurements are statistically distributed, therefore only about two-thirds of pulse<br />
oximeter equipment measurements can be expected to fall within ± Arms of the value<br />
measured by a CO-oximeter. The <strong>HeartStart</strong> <strong>XL</strong> is calibrated to display functional<br />
oxygen saturation.
<strong>HeartStart</strong> <strong>XL</strong> Addendum bij de Gebruiksaanwijzing en Service<br />
Manual<br />
Dit addendum biedt updates voor de <strong>HeartStart</strong> <strong>XL</strong> Gebruiksaanwijzing editie 7, publicatie M4735-91903 en<br />
<strong>HeartStart</strong> <strong>XL</strong> Service Manual editie 6, publicatie M4735-90900.<br />
Oplaadtijd defibrillator<br />
De oplaadtijd tot 200 joule met een nieuwe, volledig opgeladen M3516A SLA-batterij bij 25 °C is minder dan <br />
3,5 seconden.<br />
Nauwkeurigheid afgegeven energie<br />
De nauwkeurigheid van de afgegeven energie is voor sommige energieën van absolute waarden gewijzigd naar<br />
procentuele waarden. Voor geselecteerde energieën van 20 J en 30 J zijn de nauwkeurigheidswaarden voor alle<br />
belastingsimpedantiewaarden ± 15%.<br />
Disposable interne paddles<br />
De volgende disposable interne paddles zijn uit productie genomen: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -sensoren<br />
De SpO 2 -sensoren M1903B en M1904B zijn uit productie genomen. Nieuwe sensoren M1191B, M1191BL,<br />
M1192T, M1196A en M1196T zijn beschikbaar. De kenmerken van de SpO 2 -sensoren zijn:<br />
Sensor Type Type patiënt Gewicht<br />
patiënt<br />
Sensorplek Lengte<br />
kabel<br />
M1191A<br />
M1191AL<br />
Volw. > 50 kg Vinger<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Volw.,<br />
Grote volw.<br />
> 50 kg Vinger<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Duurzaam Kleine volw.,<br />
Pediatrie.<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A Pediatrie, Volw.<br />
Oorlel 150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
Volw.<br />
> 40 kg<br />
Vinger<br />
300 cm<br />
35 cm ± 3,0%<br />
M1131A Wegwerpartikel Pediatrie, Volw. > 20 kg 45 cm<br />
Nauwkeurigheid*<br />
* Met 1 SD bij 70% - 100%. Met andere woorden, metingen met een pulsoximeter kennen een<br />
statische verdeling; slechts van tweederde van het aantal metingen mag verwacht worden dat ze<br />
binnen de ± gespecificeerde waarde vallen, gemeten door een CO-oximeter. De <strong>HeartStart</strong> <strong>XL</strong> is<br />
gekalibreerd om functionele zuurstofsaturatie te tonen.<br />
2
Addenda au Manuel d’utilisation du <strong>HeartStart</strong> <strong>XL</strong> et au<br />
<strong>HeartStart</strong> <strong>XL</strong> Service Manual (en langue anglaise)<br />
Cet addenda présente les mises à jour relatives au Manuel d’utilisation du <strong>HeartStart</strong> <strong>XL</strong> Edition 7, numéro de<br />
publication M4735-91901, et au <strong>HeartStart</strong> <strong>XL</strong> Service Manual Edition 6 (Manuel de maintenance, en langue<br />
anglaise), numéro de publication M4735-90900.<br />
Temps de charge du défibrillateur<br />
Le temps de charge à 200 joules, avec une nouvelle batterie SLA M3516A à pleine charge et utilisée à une température<br />
de 25 °C, est inférieur à 3,5 secondes.<br />
Précision de l’énergie délivrée<br />
La précision de l’énergie délivrée qui, pour certains niveaux d'énergie, était auparavant exprimée en valeur absolue est<br />
désormais exprimée en pourcentage. Ainsi, pour des niveaux d'énergie sélectionnée de 20 J et de 30 J (correspondant<br />
toutes à des valeurs d’impédance de charge), les valeurs de précision sont de ± 15 %.<br />
Electrodes de défibrillation interne à usage unique<br />
La commercialisation par <strong>Philips</strong> des modèles suivants d'électrodes de défibrillation interne à usage unique a été<br />
interrompue : 989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Capteurs de SpO2 La commercialisation par <strong>Philips</strong> des capteurs de SpO2 M1903B et M1904B a été interrompue. De nouveaux modèles<br />
de capteurs sont désormais disponibles : M1191B, M1191BL, M1192T, M1196A et M1196T. Les caractéristiques de<br />
ces capteurs de SpO2 sont les suivantes :<br />
Capteur Type Type de patient Poids du<br />
patient<br />
3<br />
Site<br />
d'application<br />
Longueur<br />
du câble<br />
Précision*<br />
M1191A<br />
M1191AL<br />
Adulte > 50 kg Doigt<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1191B<br />
M1191BL<br />
Adulte, grande<br />
taille<br />
> 50 kg Doigt<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1192A<br />
M1192T<br />
Réutilisable Adulte de petite<br />
taille, enfant<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0 %<br />
M1194A Enfant, adulte<br />
Lobe de l'oreille 150 cm ± 4,0 %<br />
M1196A<br />
M1196T<br />
M1131A<br />
A usage<br />
unique<br />
Adulte<br />
Enfant, adulte<br />
> 40 kg<br />
> 20 kg<br />
Doigt<br />
300 cm<br />
35 cm<br />
45 cm<br />
± 3,0 %<br />
* Avec 1 écart-type de 70 % à 100 %. En d’autres termes, les mesures de l’oxymètre de pouls<br />
étant distribuées statistiquement, on estime que seuls environ deux tiers des mesures<br />
provenant de ces appareils peuvent respecter la précision de la valeur quadratique moyenne<br />
mesurée par un CO-oxymètre. Le <strong>HeartStart</strong> <strong>XL</strong> est calibré de façon à indiquer la saturation<br />
en oxygène du sang artériel (hémoglobine fonctionnelle).
Addendum delle Istruzioni per l'uso e del manuale tecnico di<br />
<strong>HeartStart</strong> <strong>XL</strong><br />
Il presente addendum contiene aggiornamenti alle Istruzioni per l'uso di <strong>HeartStart</strong> <strong>XL</strong> Settima Edizione, numero<br />
di parte M4735-91905 e al Service Manual (manuale tecnico, disponibile in lingua inglese) di <strong>HeartStart</strong> <strong>XL</strong> Sesta<br />
Edizione, numero di parte M4735-90900.<br />
Tempo di carica del defibrillatore<br />
Il tempo di carica a 200 Joule con una batteria SLA M3516A nuova e completamente carica a 25 °C è inferiore a <br />
3,5 secondi.<br />
Precisione dell'energia erogata<br />
La precisione dell'energia erogata in alcuni casi non viene più espressa in valori assoluti ma in valori percentuali. Per i livelli<br />
di energia selezionata di 20 e 30 joule, per tutti i valori di impedenza di carico, i valori di precisione sono pari a ± 15%.<br />
Piastre interne monouso<br />
Le seguenti piastre interne monouso non sono più disponibili per il sistema <strong>HeartStart</strong> <strong>XL</strong>: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Sensori SpO 2<br />
I sensori per SpO 2 M1903B e M1904B non sono più disponibili. Sono disponibili i seguenti nuovi sensori: M1191B,<br />
M1191BL, M1192T, M1196A e M1196T. Di seguito sono elencate le caratteristiche dei sensori SpO 2 :<br />
Sensore Tipo Tipo di<br />
paziente<br />
Peso<br />
paziente<br />
Punto di Lunghezza<br />
applicazione cavo<br />
ideale<br />
Precisione*<br />
M1191A<br />
M1191AL<br />
Adulti > 50 kg<br />
Dito della<br />
mano<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Adulti, adulti di<br />
corporatura<br />
robusta<br />
> 50 kg<br />
Dito della<br />
mano<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Adulti di<br />
Riutilizzabile<br />
corporatura 15 -50 kg<br />
minuta, bambini<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A Adulti, bambini<br />
Lobo<br />
150 cm<br />
dell'orecchio<br />
± 4,0%<br />
M1196A<br />
M1196T<br />
Adulti<br />
> 40 kg<br />
Dito della<br />
mano<br />
300 cm<br />
35 cm ± 3,0%<br />
M1131A Monouso Adulti, bambini > 20 kg 45 cm<br />
* Con 1 deviazione standard dal 70 al 100%. In altri termini, le misurazioni ottenute<br />
mediante pulsossimetro sono distribuite statisticamente, pertanto è prevedibile che solo<br />
due terzi di tali misurazioni rientrino nel valore ± Arms del valore misurato da un <br />
CO-ossimetro. Il sistema <strong>HeartStart</strong> <strong>XL</strong> è calibrato per visualizzare la saturazione di<br />
ossigeno funzionale.<br />
4
<strong>HeartStart</strong> <strong>XL</strong> Gebrauchsanweisung und Service Manual – Nachtrag<br />
Dieser Nachtrag enthält Aktualisierungen zur <strong>HeartStart</strong> <strong>XL</strong> Gebrauchsanweisung 7. Auflage (Publikationsnummer<br />
M4735-91902) sowie zum <strong>HeartStart</strong> <strong>XL</strong> Service Manual 6. Auflage (Publikationsnummer M4735-90900).<br />
Ladedauer des Defibrillators<br />
Die Aufladung auf 200 Joule erfolgt mit einem neuen, voll aufgeladenen M3516A auslaufsicheren Blei-Säure-Akku bei<br />
25 °C in weniger als 3,5 Sekunden.<br />
Genauigkeit der abgegebenen Energie<br />
Die Genauigkeit der abgegebenen Energie wurde bei manchen Energiewerten von einem absoluten in einen<br />
prozentualen Wert geändert. Für die ausgewählten Energiewerte 20 J und 30 J (alle Lastimpedanzwerte) sind die<br />
Genauigkeitswerte ± 15%.<br />
Interne Einweg-Schocklöffel<br />
Der Vertrieb der folgenden internen Einweg-Schocklöffel wurde eingestellt: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -Sensoren<br />
Der Vertrieb der SpO 2 -Sensoren M1903B und M1904B wurde eingestellt. Die neuen Sensoren M1191B, M1191BL,<br />
M1192T, M1196A und M1196T sind verfügbar. Die SpO 2 -Sensoren verfügen über folgende Merkmale:<br />
Sensor Typ Geeignet für Körpergewicht<br />
5<br />
Messort Kabellänge Genauigkeit*<br />
M1191A<br />
M1191AL<br />
Erwachsene > 50 kg Finger<br />
200 cm<br />
300 cm<br />
±2,5%<br />
M1191B<br />
M1191BL<br />
Erwachsene, <br />
> 50 kg<br />
Erwachsene (groß)<br />
Finger<br />
200 cm<br />
300 cm<br />
±2,5%<br />
M1192A<br />
M1192T<br />
Wiederverwendbar<br />
Erwachsene<br />
(klein), Kinder<br />
15–50 kg<br />
150 cm<br />
45 cm<br />
±3,0%<br />
M1194A<br />
Kinder, <br />
Erwachsene<br />
Ohrläppchen 150 cm ±4,0%<br />
M1196A<br />
M1196T<br />
Erwachsene<br />
> 40 kg<br />
Finger<br />
300 cm<br />
35 cm<br />
±3,0%<br />
M1131A Einmalverwendbar<br />
Kinder, <br />
Erwachsene<br />
> 20 kg 45 cm<br />
* Mit einer Standardabweichung von 70% bis 100%. Mit anderen Worten: Da die<br />
Ergebnisse von Pulsoxymeter-Messungen statistisch verteilt sind, fallen voraussichtlich nur<br />
etwa zwei Drittel der Pulsoxymeter-Messungen in den ± Arms-Bereich des Wertes, der von<br />
einem CO-Oxymeter gemessen wird. Der <strong>HeartStart</strong> <strong>XL</strong> ist so kalibriert, dass er die<br />
funktionelle Sauerstoffsättigung anzeigt.
Anexo a las Instrucciones de uso y al Service Manual del<br />
<strong>HeartStart</strong> <strong>XL</strong><br />
Este anexo proporciona información actualizada referente a las Instrucciones de uso <strong>HeartStart</strong> <strong>XL</strong>, 7.ª edición, n.º de<br />
publicación M4735-91904 y al Service Manual <strong>HeartStart</strong> <strong>XL</strong>, 6.ª edición, n.º de publicación M4735-90900.<br />
Tiempo de carga del desfibrilador<br />
El tiempo de carga a 200 julios con una batería de plomo-ácido nueva y completamente cargada M3516A a 25 °C es<br />
inferior a 3,5 segundos.<br />
Precisión de la energía suministrada<br />
La precisión para algunas energías suministradas ha cambiado de valores absolutos a valores porcentuales. Para las<br />
energías seleccionadas de 20 J y 30 J, todos los valores de impedancia de carga, la precisión es ± 15%.<br />
Palas internas desechables<br />
Se han descatalogado las siguientes palas internas desechables: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Sensores de SpO 2<br />
Los sensores M1903B y M1904B de SpO 2 se han descatalogado. Los nuevos sensores M1191B, M1191BL, M1192T,<br />
M1196A y M1196T ya están disponibles. Las características de estos sensores de SpO 2 son:<br />
Sensor Tipo Tipo de paciente Peso del<br />
paciente<br />
Colocación<br />
adecuada<br />
Longitud<br />
del cable<br />
Precisión*<br />
M1191A<br />
M1191AL<br />
Adulto > 50 kg<br />
Dedo de<br />
la mano<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Adulto,<br />
Adulto grande<br />
> 50 kg<br />
Dedo de<br />
la mano<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Reutilizable<br />
Adulto pequeño,<br />
Pediátrico<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A Pediátrico, Adulto<br />
Lóbulo de<br />
la oreja<br />
150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
Adulto<br />
> 40 kg<br />
Dedo de<br />
la mano<br />
300 cm<br />
35 cm ± 3,0%<br />
M1131A Desechable Pediátrico, Adulto > 20 kg 45 cm<br />
* Con 1 desviación estándar del 70% al 100%. En otras palabras, las mediciones de<br />
pulsioximetría se distribuyen estadísticamente; por tanto, sólo se puede prever que dos<br />
tercios de dichas mediciones aproximadamente recaigan dentro de ± Arms del valor<br />
medido por un Co-oxímetro. El <strong>HeartStart</strong> <strong>XL</strong> está calibrado para indicar la saturación<br />
de oxígeno funcional.<br />
6
Instruções de Uso e Manual de Manutenção do<br />
<strong>HeartStart</strong> <strong>XL</strong> - Adendo<br />
Este adendo fornece dados atualizados para as Instruções de Uso do <strong>HeartStart</strong> <strong>XL</strong>, 7ª edição, número de publicação<br />
M4735-91913 e o Manual de Manutenção do <strong>HeartStart</strong> <strong>XL</strong>, 6ª edição, número de publicação M4735-90900.<br />
Tempo de recarga do desfibrilador<br />
O tempo de carga a 200 Joules com uma bateria M3516A SLA nova, totalmente carregada, a 25°C, é inferior a <br />
3,5 segundos.<br />
Precisão da energia aplicada<br />
No caso de determinados níveis de energia, a precisão da energia aplicada passou de valores absolutos para valores<br />
percentuais. No caso de energias selecionadas iguais a 20 J e 30 J, em todos os valores de impedância de carga, <br />
a precisão equivale a ± 15%.<br />
Pás internas descartáveis<br />
As seguintes pás internas descartáveis deixaram de ser usadas: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Sensores de SpO 2<br />
Os sensores M1903B e M1904B SpO 2 já não são usados, sendo usados agora os sensores M1191B, M1191BL,<br />
M1192T, M1196A e M1196T. Os sensores de SpO 2 têm as seguintes características:<br />
Sensor Tipo Tipo de<br />
paciente<br />
7<br />
Peso do<br />
paciente<br />
Colocação<br />
ideal<br />
Extensão<br />
do cabo<br />
* Com 1 desvio padrão de 70% a 100%. Ou seja, as medidas dos equipamentos de<br />
oximetria de pulso são distribuídas estatisticamente, portanto apenas dois terços<br />
dessas medidas estarão dentro da precisão de ± Arms do valor medido por um cooxímetro.<br />
O <strong>HeartStart</strong> <strong>XL</strong> foi calibrado para exibir a saturação funcional de<br />
oxigênio.<br />
Precisão*<br />
M1191A<br />
M1191AL<br />
Adulto > 50 kg Dedo<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Adulto,<br />
> 50 kg<br />
Adulto grande<br />
Dedo<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Reutilizável<br />
Adolescente,<br />
Pediátrico<br />
15 a 50 kg<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A<br />
Pediátrico,<br />
Adulto<br />
Lóbulo da<br />
orelha<br />
150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
M1131A Descartável<br />
Adulto<br />
Pediátrico,<br />
Adulto<br />
> 40 kg<br />
> 20 kg<br />
Dedo<br />
300 cm<br />
35 cm<br />
45 cm<br />
± 3,0%
<strong>HeartStart</strong> <strong>XL</strong> -käyttöohjeen ja -huolto-oppaan lisäys<br />
Tässä lisäyksessä on päivityksiä <strong>HeartStart</strong> <strong>XL</strong> -käyttöohjeen painokseen 7, julkaisu M4735-91909,<br />
ja <strong>HeartStart</strong> <strong>XL</strong> -huolto-oppaan painokseen 6, julkaisu M4735-90900.<br />
Defibrillaattorin latausaika<br />
Laite latautuu 200 jouleen uudella, täyteen ladatulla M3516A SLA -akulla 25 °C:n lämpötilassa alle 3,5 sekunnissa.<br />
Laukaistun energian tarkkuus<br />
Joidenkin energioiden laukaistun energian tarkkuus on muuttunut absoluuttisesta prosenttiarvoksi. Valittujen<br />
energioiden 20 J ja 30 J (kaikki kuorman impedanssiarvot) tarkkuusarvot ovat ±15 %.<br />
Kertakäyttöiset sisäiset elektrodit<br />
Seuraavien kertakäyttöisten sisäisten elektrodien myynti on lopetettu: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -anturit<br />
M1903B- ja M1904B SpO 2 -anturien myynti on lopetettu. Saatavana on uudet anturit M1191B, M1191BL,<br />
M1192T, M1196A ja M1196T. SpO 2 -anturien ominaisuudet:<br />
Anturi Tyyppi Potilaan<br />
tyyppi<br />
Potilaan<br />
paino<br />
Kiinnityspaikka Kaapelin<br />
pituus<br />
Tarkkuus*<br />
M1191A<br />
M1191AL<br />
Aikuinen >50 kg Sormi<br />
200 cm<br />
300 cm<br />
±2,5 %<br />
M1191B<br />
M1191BL<br />
Aikuinen, suuri<br />
>50 kg<br />
aikuinen<br />
Sormi<br />
200 cm<br />
300 cm<br />
±2,5 %<br />
M1192A<br />
M1192T<br />
Kestokäyttöinen Pieni aikuinen,<br />
15–50 kg<br />
lapsi<br />
150 cm<br />
45 cm<br />
±3,0 %<br />
M1194A Lapsi, aikuinen Korvannipukka 150 cm ±4,0 %<br />
M1196A<br />
M1196T<br />
Aikuinen<br />
>40 kg<br />
Sormi<br />
300 cm<br />
35 cm ±3,0 %<br />
M1131A Kertakäyttöinen Lapsi, aikuinen >20 kg 45 cm<br />
* 1 vakiopoikkeama 70–100 %. Toisin sanoen koska pulssioksimetriamittaukset jakautuvat<br />
tilastollisesti, todennäköisesti vain noin kaksi kolmasosaa pulssioksimetriamittauksista on<br />
verinäytteistä tehtyjen CO-oksimetriamittausten ±Arms-arvojen rajoissa. <strong>HeartStart</strong> <strong>XL</strong> on<br />
kalibroitu näyttämään funktionaalinen happisaturaatio.<br />
8
Tillegg til brukerhåndboken og servicehåndboken for <strong>HeartStart</strong> <strong>XL</strong><br />
Dette tillegget inneholder oppdateringer av brukerhåndboken for <strong>HeartStart</strong> <strong>XL</strong>, utgave 7, publikasjonsnr.<br />
M4735-91908, og servicehåndboken for <strong>HeartStart</strong> <strong>XL</strong>, utgave 6, publikasjonsnr. M4735-90900.<br />
Ladetiden til defibrillatoren<br />
Ladetiden til 200 joule med et nytt, fulladet M3516A SLA-batteri ved 25 °C er mindre enn 3,5 sekunder.<br />
Nøyaktighet på levert energi<br />
Nøyaktigheten på levert energi for noen energier er endret fra absolutte verdier til prosentverdier. For de valgte<br />
energiene på 20 J og 30 J og alle lastimpedansverdier er nøyaktighetsverdiene ± 15 %.<br />
Interne engangselektroder<br />
Følgende interne engangselektroder er ikke lenger tilgjengelige: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -prober<br />
SpO 2 -sensorene M1903B og M1904B er ikke lenger tilgjengelige. De nye sensorene M1191B, M1191BL, M1192T,<br />
M1196A og M1196T er tilgjengelige. SpO 2 -sensorene har følgende egenskaper:<br />
Probe Type Pasienttype Pasientens<br />
vekt<br />
9<br />
Ideell Kabellengde Nøyaktighet*<br />
plassering<br />
M1191A<br />
M1191AL<br />
Voksen > 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1191B<br />
M1191BL<br />
Voksen,<br />
stor voksen<br />
> 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1192A<br />
M1192T<br />
For<br />
flergangsbruk<br />
Liten voksen/<br />
barn<br />
15-50 kg<br />
150 cm<br />
45 cm<br />
± 3,0 %<br />
M1194A Barn, voksen<br />
Øreflipp 150 cm ± 4,0 %<br />
M1196A<br />
M1196T<br />
Voksen<br />
> 40 kg<br />
Finger<br />
300 cm<br />
35 cm<br />
± 3,0 %<br />
M1131A<br />
For<br />
engangsbruk<br />
Barn, voksen > 20 kg 45 cm<br />
* Med et standardavvik på 70–100 %. Pulsoksymetermålinger er med andre ord statistisk<br />
distribuert. Derfor kan man forvente at bare ca. to tredjedeler av målinger er innenfor<br />
± Arms av verdiene som måles med et CO-oksymeter. <strong>HeartStart</strong> <strong>XL</strong> er kalibrert til å<br />
vise funksjonell oksygenmetning.
Tillägg till bruksanvisningen och servicehandboken för<br />
<strong>HeartStart</strong> <strong>XL</strong><br />
Det här tillägget innehåller uppdateringar till bruksanvisningen för <strong>HeartStart</strong> <strong>XL</strong>, Utgåva 7, publikationsnummer<br />
M4735-91906 och servicehandboken för <strong>HeartStart</strong> <strong>XL</strong>, Utgåva 6, publikationsnummer M4735-90900.<br />
Defibrillatorns laddningstid<br />
Med ett nytt, fulladdat M3516A SLA-batteri är laddningstiden till 200 joule mindre än 3,5 sekunder vid 25 °C.<br />
Precision hos den avgivna energinivån<br />
Värdena för precision hos den angivna energinivån har för vissa energinivåer ändrats från absoluta värden till<br />
procentvärden. För valda energinivåer på 20 J och 30 J, alla laddningsimpedansvärden, är<br />
noggrannhetsvärdena ± 15 %.<br />
Interna spatlar för engångsbruk<br />
Följande interna spatlar för engångsbruk är utgångna: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -givare<br />
SpO 2 -givarna M1903B och M1904B är utgångna. De nya givarna M1191B, M1191BL, M1192T, M1196A och<br />
M1196T finns tillgängliga. SpO 2 -givarna har följande egenskaper:<br />
Givare Typ Patienttyp Patientvikt Givarställe Kabellängd Precision*<br />
M1191A<br />
M1191AL<br />
Vuxen > 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1191B<br />
M1191BL<br />
Vuxen, stor vuxen > 50 kg Finger<br />
200 cm<br />
300 cm<br />
± 2,5 %<br />
M1192A<br />
M1192T<br />
Flergångs<br />
Liten vuxen, barn 15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0 %<br />
M1194A Barn, vuxen<br />
Örsnibb 150 cm ± 4,0 %<br />
M1196A<br />
M1196T<br />
Vuxen<br />
> 40 kg<br />
Finger<br />
300 cm<br />
35 cm ± 3,0 %<br />
M1131A Engångs Barn, vuxen > 20 kg 45 cm<br />
* Med 1 standardavvikelse 70 % till 100 %. Med andra ord är mätningar utförda med<br />
pulsoximeter statistiskt fördelade och därför kan bara ca två tredjedelar av dessa<br />
mätvärden förväntas falla inom ± Arms av det värde som uppmäts med en COoximeter.<br />
<strong>HeartStart</strong> <strong>XL</strong> är kalibrerad för att visa funktionell syrgasmättnad.<br />
10
<strong>HeartStart</strong> <strong>XL</strong> Dodatek návodu k obsluze a servisnímu manuálu<br />
Tento dodatek poskytuje aktualizace k <strong>HeartStart</strong> <strong>XL</strong> návodu k obsluze Vydání 7, publikace M4735-91925 a<br />
<strong>HeartStart</strong> <strong>XL</strong> servisnímu manuálu Vydání 6, publikace M4735-90900.<br />
Doba nabíjení defibrilátoru<br />
Doba nabíjení na 200 joulů při použití nové, plně nabité baterie M3516A SLA při 25 °C je do 3,5 sekundy.<br />
Přesnost aplikované energie<br />
Přesnost aplikované energie se u některých energií změnila z absolutních na procentuální hodnoty. U vybraných<br />
energií 20 J a 30 J, všech hodnot impedance zatížení jsou hodnoty přesnosti ± 15 %.<br />
Jednorázové interní přikládací elektrody<br />
Následující jednorázové interní přikládací elektrody se již neprodávají. <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Snímače SpO 2<br />
Snímače M1903B a M1904B SpO 2 přestaly být prodávány. Nové snímače M1191B, M1191BL, M1192T,<br />
M1196A, a M1196T jsou k dispozici. Snímače SpO 2 mají následující vlastnosti:<br />
Snímač Typ Typ pacienta Hmotnost<br />
pacienta<br />
11<br />
Ideální<br />
místo<br />
aplikace<br />
Délka<br />
kabelu<br />
M1191A<br />
200 cm<br />
Dospělý > 50 kg Prst ruky<br />
M1191AL 300 cm<br />
M1191B<br />
M1191BL<br />
Dospělý, dospělý<br />
> 50 kg<br />
velké postavy<br />
Prst ruky<br />
200 cm<br />
300 cm<br />
M1192A<br />
M1192T<br />
Opakovaně<br />
použitelný<br />
Dospělý malé<br />
postavy, dítě<br />
15-50 kg<br />
150 cm<br />
45 cm<br />
M1194A Dítě, dospělý<br />
Přesnost*<br />
± 2,5 %<br />
± 2,5 %<br />
± 3,0 %<br />
Ušní lalůček 150 cm ± 4,0 %<br />
M1196A<br />
> 40 kg<br />
300 cm<br />
Dospělý<br />
M1196T Prst ruky 35 cm<br />
M1131A Jednorázový Dítě, dospělý >20 kg 45 cm<br />
± 3,0 %<br />
* S 1 směrodatnou odchylkou 70 % až 100 %. Jinými slovy, hodnoty naměřené<br />
pulzním oxymetrem jsou zpracovávány statisticky, proto pouze asi dvě třetiny<br />
takových hodnot jsou v rozsahu ± Arms (rms = kvadratický průměr) hodnot<br />
naměřených CO-oxymetrem. Přístroj <strong>HeartStart</strong> <strong>XL</strong> je kalibrován pro zobrazování<br />
funkční saturace krve kyslíkem.
Συμπλήρωμα στις Οδηγίες Χρήσης και στο Service Manual (Εγχειρίδιο<br />
Τεχνικής Υποστήριξης) του <strong>HeartStart</strong> <strong>XL</strong><br />
Το παρόν συμπλήρωμα περιλαμβάνει ενημερώσεις για τις Οδηγίες Χρήσης του <strong>HeartStart</strong> <strong>XL</strong>, Έκδοση 7, αρ.<br />
δημοσίευσης M4735-91917, και για το Service Manual (Εγχειρίδιο Τεχνικής Υποστήριξης) του <strong>HeartStart</strong> <strong>XL</strong>,<br />
Έκδοση 6, αρ. δημοσίευσης M4735-90900.<br />
Χρόνος Φόρτισης Απινιδωτή<br />
Ο χρόνος φόρτισης για 200 Joule με καινούρια, πλήρως φορτισμένη μπαταρία SLA M3516A σε θερμοκρασία 25°C<br />
είναι μικρότερος από 3,5 δευτερόλεπτα.<br />
Ακρίβεια Παρεχόμενης Ενέργειας<br />
Η ακρίβεια παρεχόμενης ενέργειας για ορισμένα επίπεδα ενέργειας έχει αλλάξει από απόλυτες σε ποσοστιαίες<br />
τιμές. Για τις επιλεγμένες ενέργειες των 20 J και 30 J, για όλες τις τιμές σύνθετης αντίστασης φορτίου, οι τιμές<br />
ακρίβειας είναι ± 15%.<br />
Εσωτερικά Paddles Μίας Χρήσης<br />
Έχει σταματήσει η παραγωγή και διάθεση των ακόλουθων εσωτερικών paddles μίας χρήσης: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Αισθητήρες SpO 2<br />
Έχει σταματήσει η παραγωγή και διάθεση των αισθητήρων SpO 2 M1903B και M1904B. Διατίθενται οι νέοι<br />
αισθητήρες M1191B, M1191BL, M1192T, M1196A και M1196T. Τα χαρακτηριστικά των αισθητήρων SpO 2<br />
είναι τα εξής:<br />
Αισθητήρας Τύπος Τύπος<br />
Ασθενούς<br />
Βάρος<br />
Ασθενούς<br />
Ιδανική Μήκος<br />
Τοποθέτηση Καλωδίου<br />
* Με 1 τυπική απόκλιση 70% έως 100%. Με άλλα λόγια, οι μετρήσεις εξοπλισμού<br />
παλμικής οξυμετρίας κατανέμονται στατιστικά, συνεπώς μόνο περίπου τα δύο τρίτα<br />
των μετρήσεων με εξοπλισμό παλμικής οξυμετρίας αναμένεται να εμπίπτουν στο<br />
± Arms της τιμής που μετράται από ένα CO-οξύμετρο. Το <strong>HeartStart</strong> <strong>XL</strong> είναι<br />
βαθμονομημένο για να εμφανίζει το λειτουργικό κορεσμό οξυγόνου.<br />
Ακρίβεια*<br />
M1191A<br />
M1191AL<br />
Ενήλικας > 50 kg<br />
Δάκτυλο<br />
χεριού<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Ενήλικας,<br />
Μεγαλόσωμος<br />
ενήλικας<br />
> 50 kg<br />
Δάκτυλο<br />
χεριού<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Πολλαπλών<br />
χρήσεων<br />
Μικρόσωμος<br />
15 -50 kg<br />
ενήλικας, Παιδί<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A<br />
Παιδί,<br />
Ενήλικας<br />
Λοβός του<br />
αυτιού<br />
150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
M1131A<br />
Ενήλικας<br />
Μίας χρήσης<br />
> 40 kg<br />
Δάκτυλο<br />
χεριού<br />
300 cm<br />
35 cm<br />
± 3,0%<br />
Παιδί,<br />
Ενήλικας<br />
> 20 kg 45 cm<br />
12
<strong>HeartStart</strong> <strong>XL</strong> Használati útmutató és Szervizkönyv kiegészítés<br />
Jelen kiegészítés a <strong>HeartStart</strong> <strong>XL</strong> használati útmutató M4735-91922 kiadványszámú 7. kiadásához és a<br />
<strong>HeartStart</strong> <strong>XL</strong> szervizkönyv M4735-90900 kiadványszámú 6. kiadásához tartalmaz frissítéseket.<br />
A defibrillátor töltési ideje<br />
Új, teljesen feltöltött M3516A SLA akkumulátorral a töltési idő (25 °C-on, 200 joule-ra) kevesebb mint <br />
3,5 másodperc.<br />
Leadott energiapontosság<br />
A leadott energiapontosság néhány energia esetében az abszolút értékről százalékos értékre változott. Egyes 20 J és<br />
30 J energiaértékek esetében a teljes terhelési impedenciaérték mellett a pontosság ± 15%.<br />
Egyszer használatos belső elektródák<br />
A következő belső elektródák forgalmazása megszűnt: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 -érzékelők<br />
Az M1903B és M1904B SpO 2 -érzékelők forgalmazása megszűnt. Új M1191B, M1191BL, M1192T, M1196A és<br />
M1196T érzékelők kerültek forgalomba. Az SpO 2 -érzékelők jellemzői:<br />
Érzékelő Típus Betegtípus Beteg<br />
testsúlya<br />
13<br />
Ideális<br />
elrendezés<br />
Kábelhosszúság<br />
Pontosság*<br />
M1191A<br />
M1191AL<br />
Felnőtt > 50 kg Ujj<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Felnőtt,<br />
nagyméretű felnőtt<br />
> 50 kg Ujj<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Többször<br />
használható<br />
Kisméretű felnőtt,<br />
gyermek<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A Gyermek, felnőtt<br />
Fülkagyló 150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
Felnőtt<br />
> 40 kg<br />
Ujj<br />
300 cm<br />
35 cm<br />
M1131A<br />
Egyszer<br />
használatos<br />
Gyermek, felnőtt > 20 kg 45 cm<br />
± 3,0%<br />
* 1 standard szórással 70% és 100% között. Más szóval a pulzoximetriás mérések<br />
eredményei statisztikailag szórnak, és a pulzoximetriás méréseknek várhatóan csak<br />
mintegy kétharmada esik a CO-oximéteres méréssel meghatározott ± Arms<br />
értéktartományba. A <strong>HeartStart</strong> <strong>XL</strong> a funkcionális oxigénszaturáció megjelenítésére lett<br />
bekalibrálva.
Dodatek do Instrukcji obsługi i instrukcji Service Manual aparatu<br />
<strong>HeartStart</strong> <strong>XL</strong><br />
Niniejszy dodatek zawiera informacje aktualizujące Instrukcję obsługi aparatu <strong>HeartStart</strong> <strong>XL</strong>, wydanie 7,<br />
numer publikacji M4735-91919 oraz instrukcję <strong>HeartStart</strong> <strong>XL</strong> Service Manual, wydanie 6, numer publikacji<br />
M4735-90900.<br />
Czas ładowania defibrylatora<br />
Czas ładowania do poziomu 200 dżuli przy zainstalowanym nowym, całkowicie naładowanym akumulatorze<br />
M3516A SLA w temperaturze 25°C wynosi poniżej 3,5 sekundy.<br />
Dokładność podawania energii<br />
Dokładność podawania energii dla niektórych energii została zmieniona z wartości absolutnych na wartości<br />
procentowe. Dla wybranych energii o wartości 20 J i 30 J (wszystkie wartości impedancji obciążeniowej)<br />
wartości dokładności wynoszą ± 15%.<br />
Jednorazowe łyżki wewnętrzne<br />
Dla tego aparatu jednorazowe łyżki wewnętrzne o następujących numerach katalogowych nie są już dostępne <br />
w sprzedaży: 989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Czujniki SpO 2<br />
Dla tego aparatu nie są już dostępne w sprzedaży czujniki SpO 2 o numerach katalogowych M1903B i M1904B.<br />
Dostępne są nowe czujniki o numerach katalogowych M1191B, M1191BL, M1192T, M1196A oraz M1196T.<br />
Opis czujników SpO 2 :<br />
Czujnik Typ Kategoria<br />
wiekowa<br />
pacjenta<br />
Waga<br />
pacjenta<br />
Miejsce<br />
pomiaru<br />
Długość<br />
kabla<br />
* Z jednym odchyleniem standardowym od 70% do 100%. Ponieważ pomiary<br />
pulsoksymetryczne mają rozkład statystyczny, tylko około dwóch trzecich<br />
pomiarów saturacji mieści się w zakresie ± Arms w porównaniu do pomiarów<br />
wykonanych za pomocą CO-oksymetru. Aparat <strong>HeartStart</strong> <strong>XL</strong> jest kalibrowany<br />
tak, aby wyświetlać funkcjonalną saturację tlenową.<br />
Dokładność*<br />
M1191A<br />
M1191AL<br />
Dorośli > 50 kg Palec<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1191B<br />
M1191BL<br />
Dorośli, duży<br />
rozmiar<br />
> 50 kg Palec<br />
200 cm<br />
300 cm<br />
± 2,5%<br />
M1192A<br />
M1192T<br />
Wielorazowy Dorośli, mały<br />
15 -50 kg<br />
rozmiar; dzieci<br />
150 cm<br />
45 cm<br />
± 3,0%<br />
M1194A Dzieci, dorośli<br />
Płatek uszny 150 cm ± 4,0%<br />
M1196A<br />
> 40 kg<br />
300 cm<br />
Dorośli<br />
M1196T Palec 35 cm<br />
M1131A Jednorazowy Dzieci, dorośli > 20 kg 45 cm<br />
± 3,0%<br />
14
Anexă la Instrucţiunile de utilizare şi la Manualul de service pentru<br />
<strong>HeartStart</strong> <strong>XL</strong><br />
Această anexă oferă actualizări pentru Instrucţiunile de utilizare <strong>HeartStart</strong> <strong>XL</strong> Ediţia 7, publicaţia 453564051291<br />
şi Manualul de service <strong>HeartStart</strong> <strong>XL</strong> Ediţia 6, publicaţia M4735-90900.<br />
Durata de încărcare a defibrilatorului<br />
Durata de încărcare la 200 jouli cu o baterie M3516A SLA nouă, complet încărcată, la 25°C, este mai mică de <br />
3,5 secunde.<br />
Precizia Energiei Transmise<br />
Precizia Energiei Transmise s-a modificat pentru unele tipuri de energie de la valori absolute la procente. Pentru<br />
Energiile selectate de 20 J şi 30 J, toate valorile de impedanţă de sarcină, valorile de precizie sunt ± 15%.<br />
Padele interne de unică folosinţă<br />
Comercializarea următoarelor padele de unică folosinţă a fost întreruptă:<br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Senzori SpO 2<br />
Comercializarea senzorilor M1903B şi M1904B SpO 2 a fost întreruptă. Sunt disponibili noii senzori M1191B,<br />
M1191BL, M1192T, M1196A şi M1196T. Caracteristicile senzorilor SpO 2 sunt:<br />
Senzor Tip Tip pacient Greutate<br />
pacient<br />
15<br />
Amplasare<br />
ideală<br />
Lungime<br />
cablu<br />
M1192A Adulţi cu<br />
150 cm<br />
M1192T<br />
Reutilizabil greutate mică,<br />
Copii<br />
15 -50 kg<br />
45 cm<br />
Precizie*<br />
M1191A<br />
Deget de la 200 cm<br />
Adulţi > 50 kg ± 2,5%<br />
M1191AL mână 300 cm<br />
M1191B Adulţi, Adulţi<br />
Deget de la 200 cm<br />
> 50 kg<br />
± 2,5%<br />
M1191BL cu greutate mare mână 300 cm<br />
± 3,0%<br />
M1194A Copii, Adulţi<br />
Lobul<br />
urechii<br />
150 cm ± 4,0%<br />
M1196A<br />
M1196T<br />
Adulţi<br />
> 40 kg<br />
Deget de la<br />
mână<br />
300 cm<br />
35 cm ± 3,0%<br />
M1131A Unică folosinţă Copii, Adulţi > 20 kg 45 cm<br />
* Cu 1 deviaţie standard 70% - 100%. Cu alte cuvinte, măsurătorile efectuate de către<br />
echipamentul de pulsoximetrie sunt distribuite statistic, de aceea, numai 2/3 din<br />
măsurătorile efectuate de către echipamentul de pulsoximetrie se vor încadra în<br />
± Arms a valorii măsurate cu un co-oximetru. <strong>HeartStart</strong> <strong>XL</strong> este calibrat pentru a<br />
afişa saturaţia în oxigen funcţional.
Приложение к инструкции по эксплуатации и руководству по<br />
сервисному обслуживанию <strong>HeartStart</strong> <strong>XL</strong><br />
В настоящем приложении содержатся дополнительные сведения к Инструкции по эксплуатации <strong>HeartStart</strong> <strong>XL</strong>,<br />
7-е издание, публикация M4735-91914, а также Руководству по сервисному обслуживанию <strong>HeartStart</strong> <strong>XL</strong>, <br />
6-е издание, публикация M4735-90900.<br />
Время набора заряда дефибриллятором<br />
Время набора заряда до 200 Дж при использовании нового полностью заряженного необслуживаемого<br />
свинцово-кислотного аккумулятора M3516A при температуре 25 °C меньше 3,5 секунд.<br />
Погрешность энергии разряда<br />
Для некоторых показателей энергии погрешность энергии разряда выражается не в абсолютных величинах,<br />
как прежде, а в процентах. Для значений 20 и 30 Дж в графе "Выбранная энергия" погрешность всех<br />
показателей сопротивления нагрузки составляет ± 15%.<br />
Одноразовые внутренние электроды<br />
В настоящий момент сняты с производства следующие одноразовые внутренние электроды: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Датчики SpO 2<br />
В настоящий момент сняты с производства датчики SpO 2 M1903B и M1904B. Вы можете заказать новые<br />
датчики M1191B, M1191BL, M1192T, M1196A и M1196T. Технические характеристики датчиков SpO 2 :<br />
Датчик Тип Тип пациента Вес<br />
пациента<br />
Оптимальное<br />
расположение<br />
Длина<br />
кабеля<br />
M1191A<br />
M1191AL<br />
Для взрослых > 50 кг Палец руки<br />
200 см<br />
300 см<br />
± 2,5%<br />
M1191B Для взрослых, для<br />
200 см<br />
M1191BL<br />
взрослых крупного > 50 кг<br />
телосложения<br />
Палец руки<br />
300 см<br />
± 2,5%<br />
M1192A Для взрослых<br />
150 см<br />
M1192T<br />
Многоразовый некрупного<br />
телосложения, <br />
для детей<br />
15 -50 кг<br />
45 см<br />
± 3,0%<br />
M1194A<br />
Для детей, для<br />
взрослых<br />
Мочка уха 150 см ± 4,0%<br />
M1196A<br />
M1196T<br />
Для взрослых<br />
> 40 кг<br />
Палец руки<br />
300 см<br />
35 см<br />
± 3,0%<br />
M1131A Одноразовый<br />
Для детей, для<br />
взрослых<br />
> 20 кг 45 см<br />
Погрешность*<br />
* При 1 стандартном отклонении от 70 до 100%. Иными словами, данные измерений,<br />
полученных с помощью пульсоксиметров, распределяются статистически, вследствие чего<br />
можно ожидать, что лишь около двух третей данных измерений, полученных с<br />
использованием пульсоксиметров, окажутся в пределах ± А (эффективное значение) от<br />
значения, измеренного СО-оксиметром. Прибор <strong>HeartStart</strong> <strong>XL</strong> откалиброван для<br />
отображения функционального насыщения кислородом.<br />
16
Dodatok k návodu na obsluhu a servisnému návodu <br />
pre <strong>HeartStart</strong> <strong>XL</strong><br />
Tento dodatok uvádza aktualizácie k Návodu na obsluhu pre <strong>HeartStart</strong> <strong>XL</strong>, 7. vydanie, publikácia M4735-91924 <br />
a Servisnému návodu pre <strong>HeartStart</strong> <strong>XL</strong>, 6. vydanie, publikácia M4735-90900.<br />
Čas nabíjania defibrilátora<br />
Čas nabíjania na 200 J s novou, plne nabitou batériou SLA M3516A pri 25 °C je menej než 3,5 sekundy.<br />
Poskytovaná energetická presnosť<br />
Poskytovaná energetická presnosť sa pre niektoré druhy energie zmenila z absolútnych hodnôt na hodnoty<br />
percentuálne. Pre vybrané energetické hodnoty 20 J a 30 J, všetky hodnoty vstupnej impedancie, hodnoty<br />
presnosti sú ± 15 %.<br />
Jednorazové interné prikladacie elektródy<br />
Nasledujúce jednorazové interné prikladacie elektródy už nie sú dostupné: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
Snímače SpO 2<br />
Snímače typu M1903B a M1904B SpO 2 už nie sú dostupné. K dispozícii sú nové snímače typu M1191B,<br />
M1191BL, M1192T, M1196A, a M1196T. Snímače SpO 2 majú nasledujúce vlastnosti:<br />
Snímač Typ Typ pacienta Hmotnosť<br />
pacienta<br />
17<br />
Ideálne<br />
umiestnenie<br />
Dĺžka<br />
kábla<br />
Presnosť *<br />
M1191A<br />
200 cm<br />
Dospelý > 50 kg Prst<br />
± 2,5 %<br />
M1191AL 300 cm<br />
M1191B Dospelý,<br />
200 cm<br />
M1191BL<br />
Opakovane<br />
Dospelý veľkej<br />
postavy<br />
> 50 kg Prst<br />
300 cm<br />
± 2,5 %<br />
M1192A<br />
M1192T<br />
použiteľné Dospelý malej<br />
postavy, Dieťa<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3,0 %<br />
M1194A Dieťa, Dospelý<br />
Ušnica 150 cm ± 4,0 %<br />
M1196A<br />
> 40 kg<br />
300 cm<br />
Dospelý<br />
M1196T Prst 35 cm<br />
M1131A Jednorazový Dieťa, Dospelý > 20 kg 45 cm<br />
± 3,0 %<br />
* S 1 štandardnou odchýlkou 70 % až 100 %. Inými slovami, hodnoty namerané<br />
pulzným oxymetrom sú spracovávané štatisticky, preto len asi u dvoch tretín hodnôt<br />
nameraných pulzným oxymetrom je možné predpokladať, že sú v rozsahu ± Arms<br />
(Arms = kvadratický priemer) hodnoty nameranej CO-oxymetrom. Zariadenie<br />
<strong>HeartStart</strong> <strong>XL</strong> je kalibrované na zobrazovanie funkčnej saturácie krvi kyslíkom.
<strong>HeartStart</strong> <strong>XL</strong> Kullanım Talimatları ve Servis Kılavuzuna Ek<br />
Bu ek <strong>HeartStart</strong> <strong>XL</strong> Kullanım Talimatları 7. Baskı, 453564077311 yayını ve <strong>HeartStart</strong> <strong>XL</strong> Servis Kılavuzu 6.<br />
Baskı, M4735-90900 yayını için bir güncelleme niteliğindedir.<br />
Defibrilatör Şarj Süresi<br />
Yeni ve 25°C'de tam şarj edilmiş bir M3516A SLA pil ile 200 Joules'ün şarj süresi 3,5 saniyeden daha kısadır.<br />
Verilen Enerjinin Doğruluğu<br />
Bazı enerjiler için verilen enerjinin doğruluğu mutlak değerden yüzdelik değere çevrilmiştir. Seçilen 20 J ve 30 J<br />
enerjileri için, tüm yük empedans değerleri, Doğruluk değerleri ± %15'tir.<br />
Tek Kullanımlık Dahili Kaşıklar<br />
Aşağıdaki tek kullanımlık dahili kaşıkların üretimi durdurulmuştur: <br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171.<br />
SpO 2 Sensörler<br />
M1903B ve M1904B SpO 2 sensörlerinin üretimi durdurulmuştur. Yeni M1191B, M1191BL, M1192T, M1196A,<br />
ve M1196T model sensörler mevcuttur. SpO 2 sensörünün özellikleri:<br />
Sensör Türü Hasta Türü Hasta<br />
Ağırlığı<br />
İdeal<br />
Yerleşim<br />
Kablo<br />
Uzunluğu<br />
Doğruluk*<br />
M1191A<br />
M1191AL<br />
Yetişkin > 50 kg Parmak<br />
200 cm<br />
300 cm<br />
± %2,5<br />
M1191B<br />
M1191BL<br />
Yetişkin,<br />
> 50 kg<br />
Büyük Yetişkin<br />
Parmak<br />
200 cm<br />
300 cm<br />
± %2,5<br />
M1192A<br />
M1192T<br />
Yeniden<br />
kullanılabilir<br />
Küçük yetişkin,<br />
15 -50 kg<br />
Pediatrik<br />
150 cm<br />
45 cm<br />
± %3,0<br />
M1194A<br />
Pediatrik,<br />
Yetişkin<br />
Kulak lobu 150 cm ± %4,0<br />
M1196A<br />
M1196T<br />
Yetişkin<br />
> 40 kg<br />
Parmak<br />
300 cm<br />
35 cm<br />
± %3,0<br />
M1131A Tek<br />
kullanımlık<br />
Pediatrik,<br />
Yetişkin<br />
> 20 kg 45 cm<br />
* 1 standart sapmayla %70 ila %100. Başka bir deyişle, nabız oksimetresi ekipman<br />
ölçümleri istatistiksel olarak dağılmaktadır, bu yüzden nabız oksimetresi ekipmanı<br />
ölçümlerinin sadece yaklaşık üçte ikisinin CO-oksimetresiyle ölçülen değerin<br />
± kolları arasında olması beklenir. İşlevsel oksijen satürasyonunu göstermek için<br />
<strong>HeartStart</strong> <strong>XL</strong> kalibre edilir.<br />
18
<strong>HeartStart</strong> <strong>XL</strong> 使用说明和维修手册补遗<br />
此补遗是对 <strong>HeartStart</strong> <strong>XL</strong> 使用说明第 7 版,出版号 M4735-91911 和 <strong>HeartStart</strong> <strong>XL</strong> 维修手册<br />
第 6 版,出版号 M4735-90900 的补充说明。<br />
除颤器充电时间<br />
在 25°C 条件下,要使充满电的新 M3516A SLA 电池达到 200 焦耳能量标准,所需的充电时间不超过<br />
3.5 秒。<br />
发送的能量的精确性<br />
某些能量的发送的能量精确性值已从绝对数值改为百分比值。对于选定的 20J 和 30J 的能量,所有负载<br />
阻抗值,精确性值为 ± 15%。<br />
一次性胸内电极板<br />
不再销售下列一次性胸内电极板:<br />
989803127121, 989803127131, 989803127141, 989803127151, 989803127161, 989803127171。<br />
SpO 2 传感器<br />
不再销售 M1903B 和 M1904B SpO 2 传感器。提供了新的传感器 M1191B, M1191BL, M1192T, M1196A 和<br />
M1196T。SpO 2 传感器具有下列特性:<br />
传感器 类型 病人类型 病人体重 放置位置 电缆长度 准确度*<br />
M1191A<br />
M1191AL<br />
成人 > 50 kg 手指<br />
200 cm<br />
300 cm<br />
± 2.5%<br />
M1191B<br />
M1191BL<br />
成人、<br />
大体型成人<br />
> 50 kg 手指<br />
200 cm<br />
300 cm<br />
± 2.5%<br />
M1192A<br />
M1192T<br />
可重复使用 小体型成人、<br />
儿童<br />
15 -50 kg<br />
150 cm<br />
45 cm<br />
± 3.0%<br />
M1194A 儿童、成人<br />
耳垂 150 cm ± 4.0%<br />
M1196A<br />
M1196T<br />
成人<br />
> 40 kg<br />
手指<br />
300 cm<br />
35 cm ± 3.0%<br />
M1131A 一次性 儿童、成人 > 20 kg 45 cm<br />
19<br />
* 具有一个标准偏差 70% 至 100%。即,由于脉搏氧饱和度设备的测量结果符合统<br />
计学分布,其测量结果中仅有大约 2/3 落在 CO- 氧饱和度计所测得的 ± 边缘值<br />
之内。<strong>HeartStart</strong> <strong>XL</strong> 已校准以显示功能性氧饱和度。
<strong>HeartStart</strong> <strong>XL</strong> 使用說明與服務手冊補述<br />
本補述提供 <strong>HeartStart</strong> <strong>XL</strong> 使用說明第 7 版,出版編號 M4735-91912 及 <strong>HeartStart</strong> <strong>XL</strong> 服務手冊<br />
第 6 版,出版編號 M4735-90900 之更新。<br />
電擊器充電時間<br />
在 25°C 溫度下,使用全新充滿電量的 M3516A SLA 電池充電達到 200 焦耳所需的時間低於 3.5 秒。<br />
傳送能量精確度<br />
對於某些傳送能量精確度的表示方式,已由絕對值改為百分比方式。若選擇能量為 20 焦耳與<br />
30 焦耳,全負載阻抗值,精確度為 ± 15%。<br />
拋棄式體內電擊板<br />
下列拋棄式體內電擊板已停產:<br />
989803127121、989803127131、989803127141、989803127151、989803127161、989803127171。<br />
SpO 2 感應器<br />
M1903B 及 M1904B SpO 2 感應器已停產。新的 M1191B、M1191BL、M1192T、M1196A,及 M1196T 感應器<br />
現已供應。SpO 2 感應器特性為:<br />
感應器 類型 病患類型 病患體重 理想施用<br />
部位<br />
導線長度 精確度*<br />
M1191A<br />
M1191AL<br />
成人 > 50 公斤 指尖<br />
200 公分<br />
300 公分<br />
± 2.5%<br />
M1191B<br />
M1191BL<br />
成人 /<br />
大型成人<br />
> 50 公斤 指尖<br />
200 公分<br />
300 公分<br />
± 2.5%<br />
M1192A<br />
M1192T<br />
重複使用式 小型成人 /<br />
小兒<br />
15 -50 公斤<br />
150 公分<br />
45 公分<br />
± 3.0%<br />
M1194A 小兒 / 成人<br />
耳垂 150 公分 ± 4.0%<br />
M1196A<br />
M1196T<br />
成人<br />
> 40 公斤<br />
指尖<br />
300 公分<br />
35 公分 ± 3.0%<br />
M1131A 拋棄式 小兒 / 成人 > 20 公斤 45 公分<br />
* 有 1 個標準差 70% 至 100%。換言之,脈衝式血氧飽和計設備的測量結果呈<br />
現統計學分佈型態,所以在脈衝式血氧飽和計設備的測量結果中,僅有大約<br />
2/3 預計會落在 CO 血氧飽和計測量的 ± Arms 值範圍內。 <strong>HeartStart</strong> <strong>XL</strong> 經<br />
校正以顯示功能性血氧飽和濃度。<br />
20
<strong>HeartStart</strong> <strong>XL</strong> ユーザーズ・ガイド / Service Manual 補遺<br />
本書は、『<strong>HeartStart</strong> <strong>XL</strong> ユーザーズ・ガイド第 7 版』(publication M4735-91907)および<br />
『<strong>HeartStart</strong> <strong>XL</strong> Service Manual Edition 6』(publication M4735-90900)の内容を更新す<br />
るものです。<br />
除細動器の充電時間<br />
新しい完全充電済み M3516A SLA バッテリを 25 ℃で使用している場合、200 ジュールまでの充電時<br />
間は 3.5 秒以内です。<br />
通電エネルギー確度<br />
一部のエネルギー値に対する通電エネルギー確度が、絶対値からパーセント値に変更されました。<br />
選択エネルギー 20 J および 30 J では、すべての負荷インピーダンス値に対する確度が ±15% です。<br />
SpO 2 センサ<br />
M1903B / M1904B SpO 2 センサの販売を終了しました: 新しいセンサとして、M1191B と M1191BL を使用<br />
できます。下表に SpO 2 センサの特性を示します:<br />
センサ タイプ 患者タイプ 患者体重 推奨装着<br />
部位<br />
M1191A*1<br />
200 cm<br />
成人用 > 50 kg 手指<br />
M1191AL*1 300 cm<br />
リユーザブル<br />
M1191B 成人用、<br />
200 cm<br />
> 50 kg 手指<br />
M1191BL 成人用(大) 300 cm<br />
21<br />
ケーブル長 確度 *2<br />
±2.5%<br />
±2.5%<br />
*1 日本国内では、M1191A および M1191AL は販売しておりません。<br />
*2 1SD(70% ~ 100%)の値を示します。パルスオキシメータ機器の測定値は統計的分<br />
布値であり、その測定値の約 3 分の 2 のみがコオキシメータで測定した ±Arms<br />
値の範囲内に含まれると予測されます。また <strong>HeartStart</strong> <strong>XL</strong> は動脈血の機能性酸<br />
素飽和度を表示するように校正されています。
<strong>Philips</strong> Healthcare<br />
3000 Minuteman Road<br />
Andover, MA 01810<br />
www.philips.com/healthcare<br />
© 2012 Koninklijke <strong>Philips</strong> Electronics N.V<br />
All rights are reserved<br />
Printed in the USA<br />
453564087591 Edition 2 * April 2012<br />
*453564087591 *<br />
*2*