Results<br />
i<strong>de</strong>xx.com<br />
Twenty three thermal pool water samples were analyzed during this study. Of these<br />
samples, four were found to be naturally contaminated with P. aeruginosa. The ability of the<br />
<strong>Pseudalert*</strong> and the ISO 16266 methods to <strong>de</strong>tect these natural P. aeruginosa popu<strong>la</strong>tions is<br />
shown below:<br />
Recovery of natural P. aeruginosa popu<strong>la</strong>tions by the two methods matched perfectly,<br />
which suggests that both methods have simi<strong>la</strong>r specificities for P. aeruginosa. Four of the<br />
samples (No.’s 1, 2, 3, and 4) tested with the ISO 16266 method had presumptive positive<br />
colonies that required secondary confirmation to exclu<strong>de</strong> the presence of P. aeruginosa.<br />
Pseudalert was able to suppress these bacteria and did not require additional testing. Over