3a-i VFD's U-6 - FM3 - Inj. Fan - AFS Energy Systems

3a-i VFD's U-6 - FM3 - Inj. Fan - AFS Energy Systems 3a-i VFD's U-6 - FM3 - Inj. Fan - AFS Energy Systems

afsenergy.com
from afsenergy.com More from this publisher
05.05.2013 Views

f Allen Bradley Power J @ 40 Adjustable Frequency AC Drive Drehzahlveranderbarer Frequenzumrichter Variateur de vitesse c a Inverter CA a frequenza variabile Variador de Frecuencia Ajustable de CA AC Drive Inversor CA de FreqOencia Ajustavel FRN 2 xx Quick Start Kurzanleitung Guide de mise en route Avviamento rapido Inicio Rapido Snel aan de slag Partida rapida Rockwell Automation

f Allen Bradley<br />

Power J @<br />

40<br />

Adjustable Frequency AC Drive<br />

Drehzahlveranderbarer Frequenzumrichter<br />

Variateur de vitesse c a<br />

Inverter CA a frequenza variabile<br />

Variador de Frecuencia Ajustable de CA<br />

AC Drive<br />

Inversor CA de FreqOencia Ajustavel<br />

FRN 2 xx<br />

Quick Start<br />

Kurzanleitung<br />

Guide de mise en route<br />

Avviamento rapido<br />

Inicio Rapido<br />

Snel aan de slag<br />

Partida rapida<br />

Rockwell<br />

Automation


tm<br />

PowerFlex 40 Adjustable<br />

Frequency AC Drive<br />

FRN2 xx<br />

Quick Start<br />

This Quick Start guide summarizes the basic steps needed to install<br />

start up<br />

and program the PowerFlex 40 Adjustable Frequency AC Drive<br />

The information provided Does Not replace the User Manual and is<br />

intended for qualified drive service personnelonly<br />

For detailed PowerFlex 40 information induding EMC instructions<br />

application considerations and related precautions refer to the<br />

PowerFlex 40 User Manual Publication 22B UMOOl on the CD<br />

supplied with the drive or at wwwab com manuals dr<br />

General Precautions<br />

ATTENTION The drive contains high voltage capacitors which take<br />

time to discharge after removal of mains supply Before working on<br />

drive ensure isolation of mains supply from line inputs R S T Ll<br />

L2 L3 Wait three minutes for capacitors to discharge to safe voltage<br />

levels Failure to do so may resultin personal injury or death<br />

Darkened display LEDs is not an indication that capacitors have<br />

discharged to safe voltage levels<br />

ATTENTION Equipment damage andor personal injury may result<br />

if parameter A092 Auto RstrtTries or A094 Start At PowerUp is<br />

used in an inappropriate application Do not use this function without<br />

considering applicable local national and international codes<br />

standards or regulations industry guidelines<br />

ATTENTION Only qualified personnel familiar with adjustable<br />

frequency AC drives and associated machinery should plan or<br />

implement the installation start up and subsequent maintenance of the<br />

system Failure to comply may result in personal injury andor<br />

equipment damage<br />

ATTENTION This drive contains ESD Electrostatic Discharge<br />

sensitive parts and assemblies Static control precautions are required<br />

when installing testing servicing or repairing this assembly<br />

Component damage may result if ESD control procedures are not<br />

followed If you are not familiar with static control procedures<br />

reference A B publication 8000 4 5 2 Guarding Against Electrostatic<br />

Damage or any other applicable ESD protection handbook<br />

ATTENTION An incorrectly applied orinstalled drive can result in<br />

component damage ora reduction in product life Wiring or application<br />

errors such as undersizing the motor incorrect or inadequate AC<br />

supply orexcessive ambient temperatures may result in malfunction of<br />

the system


English 2<br />

Mounting Considerations<br />

Mount the drive upright on a flat vertical and level surface<br />

Frame Screw Size Screw Torque DIN Rail<br />

B M4 8 32 1 56 1 96 N m 14 17 lb in 35mm<br />

C M5 10 24 245 2 94 N m 22 26 lb in<br />

Protect the cooling fan by avoiding dust or metallic particles<br />

Do not expose to a corrosive atmosphere<br />

Protect from moisture and direct sunlight<br />

Minimum Mounting Clearances<br />

See page 16 for mounting dimensions<br />

V 0 1V 0 1<br />

120mm<br />

4 7 In<br />

odobo odobo<br />

fJPoo 6l 00<br />

0 0<br />

120mm<br />

47ln<br />

0 0<br />

i II 1<br />

1 Mounting Option A<br />

J No clearance required<br />

between drives<br />

Mounting Option B<br />

Ambient Operating Temperatures<br />

rl<br />

o<br />

Iillm<br />

odobo<br />

fJPoo<br />

25mm<br />

ro 1 0 in<br />

1 V 0 1<br />

120mm<br />

0 0<br />

47in<br />

odobo<br />

Woo<br />

1<br />

o 0<br />

120 mm<br />

47 in<br />

I II I<br />

Ambient Temperature Enclosure Rating Minimum Mounting<br />

Minimum Maximum Clearances<br />

1<br />

400C 104OF<br />

IP 20 0pen Type<br />

Use Mounting Option A<br />

10oC WF IP 30 NEMA 1 UL Type 11 1 Use Mounting Option B<br />

500C 122OF IP 20 0pen Type Use Mounting Option B<br />

Rating requires installation of the PowerFlex 40 IP 30 NEMA 1 UL Type 1 option kit<br />

General Grounding Requirements<br />

CE Conformity<br />

Important Remove the MOV to ground jumper if the<br />

drive is installed on an ungrounded distribution system<br />

Tighten screw after jumper removal<br />

D<br />

odo bo<br />

6000<br />

0<br />

Refer to the PowerFlex 40 User Manualon the CD supplied with the<br />

drive for details on how to comply withthe Low Voltage LV and<br />

Electromagnetic Compatibility EMC Directives


Drive Ratings<br />

Catalog<br />

Number<br />

Specifications Fuses and Circuit Breakers<br />

Output Ratings Input Ratings Branch Circuit Protection<br />

22B V2P3Nl04 04 0 5 2 3 90 132 1 15 9 0 15 140M C2E C16 100 C12 30<br />

22B V5PON104 075 1 0 5 0 90 132 245 20 3 35 140M D8E C20 100 C23 56<br />

22B V6PON104 1 15 6 0 90 132 3 0 24 0 40 140M F8E C32 100 C37 70<br />

all<br />

200 240V AC 1 0r 1 Phase Input O 230V 3 Phase Output<br />

22B A2P3Nl04 04 0 5 2 3 180 264 15 6 0 10 140M C2E B63 100 C09 30<br />

22B A5PON104 075 10 5 0 180 264 245 12 0 20 140M C2E C16 100 C12 55<br />

22B A8PON104 15 2 0 8 0 180 264 4 0 18 0 30 140M 08E C20 100 C23 80<br />

22B A012N104 2 2 3 0 12 0 180 264 5 5 25 0 40 140M F8E C32 100 C37 110<br />

200 240V AC 110 3 Phase Input O 230V 3 Phase Output<br />

22B B2P3N104 04 0 5 2 3 180 264 15 2 5 6 140M C2E B40 100 C07 30<br />

22B B5PON104 075 10 5 0 180 264 245 5 7 10 140M C2E C10 100 C09 55<br />

22B B8PON104 1 5 2 0 8 0 180 264 4 0 9 5 15 140M C2E C16 100 C12 80<br />

22B B012Nl04 2 2 3 0 12 0 180 264 5 5 15 5 25 140M C2E C16 100 C23 115<br />

22B B017N104 3 7 5 0 17 5 180 264 8 6 210 35 140M F8E C25 100 C23 165<br />

22B B024Nl04 5 5 7 5 24 0 180 264 11 8 26 1 40 140M F8E C32 100 C37 226<br />

22B B033N104 7 5 10 0 33 0 180 264 16 3 34 6 60 140M G8E C45 100 C60 290<br />

380 480V AC 110 3 Phase Input 0 460V 3 Phase Output<br />

22B Dl P4N104 04 0 5 14 342 528 14 1 8 3 140M C2E B25 100 C07 30<br />

22B D2P3N104 075 10 2 3 342 528 2 3 3 2 6 140M C2E B40 100 C07 40<br />

22B D4PON104 1 5 2 0 4 0 342 528 4 0 5 7 10 140M C2E B63 100 C09 60<br />

22B D6PON104 2 2 3 0 6 0 342 528 5 9 7 5 15 140M C2E Cl0 100 C09 90<br />

22B D010Nl04 4 0 5 0 10 5 342 528 10 3 13 0 20 140M C2E C16 100 C23 150<br />

22B D012Nl04 5 5 7 5 12 0 342 528 11 8 14 2 25 140M D8E C20 100 C23 160<br />

22B D017Nl04 7 5 10 0 17 0 342 528 16 8 184 30 140M D8E C20 100 C23 200<br />

22B D024Nl04 11 0 15 0 24 0 342 528 234 26 0 50 140M F8E C32 100 C43 285<br />

460 600VAC 110 3 Phase Input 0 575V 3 Phase Output<br />

22B El P7N104 0 75 1 0 1 7 414 660 2 1 2 3 6 140M C2E B25 100 C09 40<br />

22B E3PON104 15 2 0 3 0 414 660 3 65 3 8 6 140M C2E B40 100 C09 60<br />

22B E4P2Nl04 2 2 3 0 4 2 414 660 5 2 5 3 10 140M C2E B63 100 C09 90<br />

22B E6P6Nl04 4 0 5 0 6 6 414 660 8 1 8 3 15 140M C2E Cl0 100 C09 150<br />

22B E9P9Nl04 5 5 7 5 9 9 414 660 12 1 11 2 20 140M C2E C16 100 C16 160<br />

22B E012Nl04 7 5 10 12 2 414 660 14 9 137 25 140M C2E C16 100 C23 200<br />

22B E019N104 110 15 0 19 0 414 660 23 1 24 1 40 140M D8E C25 100 C30 285<br />

1<br />

2<br />

200 240V AC 1 Phase drives are also available withan integral EMC filter Catalog suffix<br />

changes from N104 to Nl14<br />

Refer to the Bulletin 140M Motor Protectors Selection Guide publication 140M SG001<br />

determine the frame and breaking capacity required for your application<br />

English 3<br />

to


English 4<br />

Programmable Output form C relay<br />

Resistive Rating 3 0A at 30V DC 3 0A at 125V AC 3 0A at 240V AC<br />

Inductive Rating 0 5A at 30V DC 0 5A at 125V AC 0 5A at 240V AC<br />

Fuses and Circuit Breakers<br />

o<br />

UL508C C CSA22 2 0<br />

Dlrea<br />

EMC<br />

36<br />

LV EN50178 EN60204<br />

EMC EN61800 3 EN 50081 EN50082 2<br />

Opto Outputs<br />

30V DC 50mA<br />

Non inductive<br />

Recommended Fuse Type UL Class J CC T or Type BS88 600V 550V or equivalent<br />

Recommended Circuit Breakers HMCP circuit breakers or equivalent<br />

Protective Features<br />

Motor Protection 12t overload protection 150 for 60 Secs 200 for 3 Secs Provides Class 10 protection<br />

Overcurrent 200 hardware iimit 300 instantaneous fault<br />

Analog Outputs 10bit<br />

oIOV Ikohm Min<br />

4 20mA 525 ohm Max<br />

Over Voltage 100 120V AC Input Trip occurs at 405V DC bus voltage equivalent to 150V AC incoming line<br />

200 240V AC Input Trip occurs at 405V DC bus voltage equivalent to 290V AC incoming line<br />

380 460V AC Input Trip occursat 810V DC bus voltage equivalent to 575V AC incoming iine<br />

460 600V AC Input Trip occurs at 1005V DC bus voltage equivalent to 711V AC incoming iine<br />

Under Voltage 100 120V AC Input Trip occurs at 210V DC bus voltage equivalent to 75V AC incoming line<br />

200 240V AC Input Trip occurs at 210V DC bus voltage equivalent to 150V AC incoming iine<br />

380 480V AC Input Trip occurs at 390V DC bus voltage equivalent to 275V AC incoming line<br />

460 600V AC Input If P042 3 High Voltage trip occursat487V DC bus voltage 344V AC incoming iine<br />

If P042 2 Low Voltage trip occursat 390V DC bus voltage 275V AC incoming iine<br />

Control Ride Through Minimum ride through is 0 5 Secs typical value 2 Sees<br />

Faultless Power Ride Through 100 milliseconds<br />

Dynamic Braking<br />

Internal brake IGBT included with all ratings Refer to Appendix B of the PowerFlex 40 User Manual on CD for DB resistor<br />

ordering information


Power Wiring<br />

Power Wire Rating<br />

Unshielded BOOV 75 C 167 F THHNITHWN<br />

Shielded 600V 75 C or 90 C 167 F or 194 F RHHI<br />

RHW 2<br />

Shielded Tray rated 600V 75 C or 90 C 167 F or 194 F<br />

RHH RHW 2<br />

Power Terminal Block<br />

Terminal<br />

1<br />

Description<br />

RL1 S L2 1 Phase Input<br />

R L 1 S L2 T L3 3 Phase Input<br />

C Frame<br />

RILl Sl2<br />

English S<br />

Recommended Copper<br />

Wire<br />

15 Mils insulated dry location<br />

Anixter OLF 7xxxxx<br />

Belden 29501 29507 or<br />

equivalent<br />

Anixter 7V 7xxxx 3G<br />

Shawflex 2ACD 3ACD or<br />

equivalent<br />

UfT1 To Motor UfT1<br />

W Switch two motor<br />

any<br />

VIT2 To Motor VIT2 leads to change<br />

forward direction<br />

WIT3 To Motor WIT3<br />

P2 P1<br />

DC Bus Inductor Connection C Frame drives only<br />

The C Frame drive is shipped with a jumper between<br />

Terminals P2 and P1 Remove this jumper only when a DC<br />

Bus Inductor will be connected Drive will not power up<br />

without a jumper or inductor connected<br />

OCt DC DC Bus Connection<br />

BRt BR Dynamic Brake Resistor Connection<br />

@ Safety Ground PE<br />

1<br />

Important Terminal screws may become looseduring shipment Ensure that all<br />

terminal screws aretightened to the recommended torque before applying power to<br />

the drive<br />

Power Terminal Block Specifications<br />

Frame Maximum Wire Size 2 Minimum Wire Size 2<br />

Torque<br />

B 53 mm2 10 AWG 1 3 mm2 16 AWG 1 7 22 N m 16 19 lb in<br />

C 84 mm2 8AWG 1 3 mm2 16 AWG 2 9 3 7 N m 26 33 lb in<br />

2 Maximum minimum sizes that the terminal block will accept these are not<br />

recommendations


English 6<br />

Input Power Conditions<br />

Input Power Condition Corrective Action<br />

Low Line Impedance less than 1 line reactance Install Line Reacto 1<br />

Greater than 120 kVA supply transformer<br />

or Isolation Transformer<br />

or Bus Inductor 5 5 11 kW<br />

7 5 15 HP drives only<br />

Line has power factor correction capacitors Install Line Reactor<br />

Line has frequent power interruptions<br />

Line has intermittent noise spikes in excess of<br />

6000V lightning<br />

or Isolation Transformer<br />

Phase to ground voltage exceeds 125 of normal Remove MOV jumper to ground<br />

line to line voltage or Install Isolation Transformer<br />

Ungrounded distribution system<br />

with grounded secondary if<br />

necessary<br />

240V open delta configuration stinger leg Install Line Reactor<br />

1<br />

Refer to Appendix B of the PowerFlex 40 User Manual on CD for accessory ordering<br />

information<br />

I O Wiring Recommendations 2<br />

Wire Type s Description Minimum Insulation<br />

Rating<br />

Belden 8760 9460 0 8 mm2 18AWG twisted pair 100 shield<br />

or equiv with drain 300V<br />

60 degrees C<br />

Belden 8770<br />

or equiv<br />

0 8 mm2 18AWG<br />

remote pot only<br />

3 conductor shielded for 140 degrees F<br />

2<br />

Ifthe wires are short and contained within a cabinet which has no sensitive circuits<br />

the use of shielded wire may not be necessary but is always recommended<br />

1 0 Terminal Block Specifications<br />

Frame Maximum Wire Size 3 Minimum Wire Size 3<br />

Torque<br />

B C 1 3 mm2 16 AWG 0 13 mm2 26 AWG 0 50 8 N m 4 7 lb in<br />

3 Maximum minimum that the terminal block will accept these are not<br />

recommendations<br />

Refer to the PowerFlex 40 UserManual on CD for maximum power and<br />

control cable length recommendations


1<br />

Control Terminal Block<br />

Control Wiring Block Diagram<br />

Relay NO Rl<br />

Relay Common<br />

Enable 4<br />

Jumper<br />

R2<br />

f<br />

m<br />

Stop 1<br />

01<br />

Start<br />

T plcal<br />

SR Wiring<br />

W<br />

Run FWD 2<br />

02<br />

03<br />

04<br />

05<br />

06<br />

07<br />

08<br />

09<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

DirectionRun REV<br />

Oigital Common<br />

Digital Input 1<br />

Digital Input 2<br />

Oigitallnput 3<br />

Digital Input 4<br />

Opto Common<br />

24V DC<br />

10V OC<br />

I I<br />

0 10V I I<br />

or t10V lnput<br />

Analog Common<br />

4 20mA input<br />

Analog Output<br />

Relay<br />

17<br />

18<br />

19<br />

RS485 Shield<br />

I j<br />

V ENBL<br />

05 06 07 08 09<br />

4<br />

Enable<br />

Jumper<br />

N C<br />

R3<br />

I i 30VOC<br />

50mA<br />

I<br />

Non inductive<br />

1 I 1<br />

o<br />

I rg1TT Analog Output Select<br />

V0 20mA SRC<br />

01 02 03 04<br />

tJ V<br />

181<br />

EJ Jl Jl<br />

13 14 15 16 17 18 1<br />

lDC D ClD ClD ClD ClD ClD<br />

1<br />

t24V<br />

Important I O Terminal 01 is always a coast to stop<br />

input except when P036 Start Source is set to<br />

3 Wire control In three wire control I O Terminal 01<br />

is controlled by P037 Stop Mode All other stop<br />

sources are controlled by P037 Stop Mode<br />

101<br />

I<br />

I I<br />

English 7<br />

Important The drive is shipped with a jumper installed between I O Terminals 01 and 11 Remove<br />

this jumper when using I O Terminal 01 as a stop or enable input<br />

2 Two wire control shown For three wire control use a momentary input on I O Terminal 02 t9<br />

command a start Use a maintained input 0 for I O Terminal 03 to change direction<br />

3 When using an opto output with an inductive load such as a relay install a recovery diode parallel<br />

to the relay as shown to prevent damage to the output<br />

P0361Slart Source SlOp 110 Terminal 01 Stop<br />

Keypad Per P03 Coa<br />

3 Wire Per P037 Per P037<br />

2Wira PerP037 Coa<br />

RS485 Port PerP037 Coa<br />

4 When the ENBLjumper is removed I O Terminal 01will always act as a hardware enable causing<br />

a coast to stop Refer to the PowerFlex 40 User Manual on CD for more information<br />

3<br />

24V


English a<br />

Control 1 0 Terminal Designations<br />

No Signal Default Description Paramo<br />

Rl Relay N O Fault Normally open contact for output relay A055<br />

R2 Relay Common Common for output relay<br />

R3 Relay N C Fault Normally closed contact for output relay A055<br />

Analog Output Select<br />

DIP Switch<br />

SinkSource<br />

DIP Switch<br />

01 Stop 1<br />

0 10V Sets<br />

analog output to either voltage or current Setling must match<br />

A065 Analog Out Sel<br />

Source SRC<br />

Inputs can be wired as Sink SNK or Source SRC via DIP Switch<br />

setling<br />

Coast The factory installed jumper ora normally closed P036 1<br />

input must be present for the drive to start<br />

02 StartRun FWD Not Active Command comes from the integral keypad by default P036 P037<br />

03 Direction Run REV Not Active<br />

To disable reverse operation see A095 Reverse P036 P037<br />

Disable<br />

04 Digital Common For digital inputs Electronically isolated with digital<br />

inputs from analog I O and opto outputs<br />

05 Digital Input I Preset Freq Program with A051 Digitallnl Sel A051<br />

A095<br />

06 Digital Input 2 Preset Freq Program with A052 Digitalln2 Sel A052<br />

07 Digital Input 3 Local Program with A053 Digitalln3 Sel A053<br />

08 Digital Input 4 Jog Forward Program with A054 Digitalln4 Sell A054<br />

09 Opto Common For opto coupled outputs Electronically isolated with<br />

opto outputs from analog I O and digital inputs<br />

11 24V DC Referenced to Digital Common<br />

Drive supplied power for digital inputs<br />

Maximum output current is 100mA<br />

12 10V DC Referenced to Analog Common P038<br />

Drive supplied powerfor0 1 OV external<br />

potentiometer<br />

Maximum output current is 15mA<br />

13 10V In 2 Not Active For external 0 1 OV unipolar or1 OV bipolar input P038<br />

supply input impedance lOOk ohm or A051 A054<br />

potentiometer wiper A123 A132<br />

14 Analog Common For 01 OV In or 4 20mA In Electronically isolated<br />

15 4 20mA In 2<br />

with analog inputs and outputs from digital 110 and<br />

opto outputs<br />

Not Active For external4 20mA input supply P038<br />

input impedance 250 ohm A051 A054<br />

16 Analog Output OutFreq 0 10 The default analog output is 0 1 OV To covert to a A065 A066<br />

current value change the Analog Output Select DIP<br />

Switch to 0 20mA Program with A065 Analog Out<br />

Sel Max analog vaiue can be scaled with A066<br />

Analog Out High<br />

Maximum Load 4 20mA 525 ohm 10 5V<br />

0 10V 1k ohm 10mA<br />

17 Opto Output 1 MotorRunning Program with A058 Opto Outl Sel A058 A059<br />

18 Opto Output 2 At Frequency Program with A061 Opto Out2 Sell A061 A062<br />

19 RS485 DSI Shield Terminal should be connected to safety ground PE<br />

I<br />

See Footnotes 1 and 4 on page 7<br />

when using the RS485 DSI communications port<br />

2 0 10V In and 4 20mA In aredistinct input channels and be connected<br />

may simultaneously<br />

Inputs may be used independently for speed control or jointly whenoperating in PID mode<br />

A132<br />

A064<br />

A064


Prepare For Drive Start Up<br />

ATTENTION Power must be applied to the drive to perform the<br />

following start up procedures Some of the voltages present<br />

English 9<br />

are at<br />

incoming line potentiai To avoid electric shock hazard or damage to<br />

equipment only qualified service personnel should perform the<br />

following procedure Thoroughly read and understand the procedure<br />

before beginning If an event does not occur while performing this<br />

procedure Do Not Proceed Remove All Power including user<br />

supplied control voltages User supplied voltages may exist even when<br />

main AC power is not applied to the drive Correct the malfunction<br />

before continuing<br />

Before Applying Powerto the Drive<br />

o 1 Confirm that all inputs are connected to the correct terminals and are<br />

secure<br />

o 2 Verify that AC line power at the disconnect device is within the rated<br />

value of the drive<br />

o 3 Verify that any digital control power is 24 volts<br />

o 4 Verify that the Sink SNK Source SRC Setup DIP Switch is set to<br />

match your control wiring scheme See page 7 for location<br />

Important The default control scheme is Source SRC The Stop<br />

terminal is jumpered IOTerminals 0I and II to allow<br />

starting from the keypad If the control scheme is changed<br />

to Sink SNK the jumper must be removed fromIO<br />

Terminals 01 and 11 and installed betweenIO Terminals<br />

01 and 04<br />

o 5 Verify that the Stop input is present or the drive will not start<br />

Important IfIO Tenninal 01 is used as a stop input the jumper<br />

betweenIO Terminals 0 I and 11 must be removed<br />

Applying Power to the Drive<br />

o 6 Apply AC power and control voltages to the driVe<br />

o 7 Familiarize yourself with the integral keypad features see next page<br />

before setting any Program Group parameters<br />

Start Stop Direction and Speed Control<br />

Factory default parameter values allow the drive to be controlled from<br />

the integral keypad No programming is required to start stop change<br />

direction and control speed directly from the integral keypad<br />

Important To disable reverse operation see A095 Reverse Disable<br />

If a fault appears on power up refer to page 17 for an explanation of the<br />

fault code For complete troubleshooting information refer to the<br />

with the drive<br />

PowerFlex 40 User Manual on the CD supplied


English 10<br />

Integral Keypad<br />

FAULT<br />

00 00<br />

@CBCV@ 0<br />

10<br />

Menu<br />

No LED LED State Description<br />

d<br />

p<br />

R<br />

Description<br />

Display Group View Only<br />

Consists of commonly viewed drive operating<br />

conditions<br />

Basic Program Group<br />

Consists of most commonly used<br />

programmable functions<br />

Advanced Program Group<br />

Consists of remaining programmable functions<br />

F Fault Designator<br />

Consists of list of codes for specific fault<br />

conditions Displayed only whenfault is present<br />

0 Run Direction Steady Red Indicates drive is running and commanded motor direction<br />

Status<br />

Flashing Red Drive has been commanded to change direction Indicates<br />

actual motor direction while decelerating to zero<br />

@ Alphanumeric Steady Red Indicates parameter number parameter value or fault code<br />

Display<br />

Flashing Red Single digit flashing indicates that digit can be edited<br />

AIi digits flashing indicates a fault condition<br />

@ Displayed Units Steady Red Indicates the units of the parameter value being displayed<br />

0 Program Status Steady Red Indicates parameter value can be changed<br />

0 Fault Status Flashing Red Indicates drive is faulted<br />

0 Pot Status Steady Green Indicates potentiometer on Integral Keypad is active<br />

0 Start Key Status Steady Green Indicates Start key on Integral Keypad is active<br />

The Reverse key is also active unless disabled by A095<br />

Reverse Disable<br />

No Key Name<br />

Description<br />

0 Escape Back one step in programming menu<br />

Cancel a change to a parameter valueand exit Program<br />

Mode<br />

0<br />

@ Select Advance one step in programming menu<br />

Select a digit when viewing parameter value<br />

i@ Up Arrow Scroll through groups and parameters<br />

Down Arrow Increase decrease the valueof a flashing digit<br />

8 Enter Advance one step in programming menu<br />

Save a change to a parameter value<br />

0 Potentiometer Used to control speed of drive Default is active<br />

Controlled by parameter P038<br />

Start Used to start the drive Default is active<br />

CI<br />

QJ<br />

Controlled by parameter P036<br />

Reverse Used to reverse direction of the drive Default is active<br />

Controlied by parameters P036 and A095<br />

Stop<br />

Used to stop the drive or clear a fault<br />

This key is always active<br />

Controlled by parameter P037


Viewing and Editing Parameters<br />

English 11<br />

The last userselected Display Group parameter is saved when power is removed and is<br />

displayed by default when power is reapplied<br />

The following is an example of basic integral keypad and display functions This example<br />

provides basic navigation instructions and illustrates how to program the first Program<br />

Group parameter<br />

Step Key s<br />

1 When power is applied the last user selected<br />

Display Group parameter number is briefly<br />

displayed with flashing characters The display<br />

then defaults to that parameter s current value<br />

Example shows the value of d001 Output<br />

Freq with the drive stopped<br />

2 Press Ese once to display the Display Group<br />

parameter number shown on power up The<br />

parameter number will flash<br />

3 Press Ese again to enter the group menu The<br />

group menu letter will flash<br />

4 Press the Up Arrow or Down Arrow to scroll<br />

through the group menu d P and A<br />

0orCY<br />

5 Press Enter or Sel to enter a group The right Bor@<br />

digit of the last viewed parameter in that group<br />

will flash<br />

6 Press the Up Arrow or Down Arrowto scroll<br />

through the parameters that arein the group<br />

7 Press Enteror Selto view the value of a<br />

parameter If you do not want to edit the value<br />

press Ese to return to the parameter number<br />

8 Press Enter or Sel to enter program mode to<br />

edit the parameter value The right digit will<br />

flash and the Program LED will illuminate If the<br />

parameter can be edited<br />

9 Press the Up Arrow or Down Arrow to change<br />

the parameter value If desired press Sel to<br />

movefrom digit to digit or bit to bit The digit or<br />

bit that you can change will flash<br />

10 Press Ese to cancel a change The digit will<br />

stop flashing the previous value is restored and<br />

the Program LED will turn off<br />

Or<br />

Press Enterto save a change The digit will stop<br />

fiashing and the Program LED will turn off<br />

11 Press Ese to return to the parameter list<br />

Continue to press Ese to back outof the<br />

programming menu<br />

If pressing Ese does not change the display<br />

then d001 Output Frequency is displayed<br />

Press Enter or Sel to enter the group menu<br />

0or@<br />

Bor@<br />

Bor@<br />

B<br />

Example Displays<br />

0orG<br />

VOLTS<br />

Inu Unlo<br />

PROGRAM FAULT<br />

o 0<br />

Id 0 0 lm<br />

PROGRAM FAULT<br />

o 0<br />

oo<br />

PROGRAM FAULT<br />

o 0<br />

P 0 3 H<br />

PROGRAM FAULT<br />

o 0<br />

I 2 3 Ol<br />

PROGRAM FAULT<br />

o 0<br />

I 2 3 Q<br />

PROGRAM FAULT<br />

0<br />

I<br />

0 VOLTS<br />

0 AMPS<br />

o HERTZ<br />

2 2 UOHERTZ nl<br />

PROGRAM FAULT<br />

o 0<br />

10<br />

OVOLTS<br />

n J<br />

U J<br />

J<br />

PROGRAM FAULT<br />

o 0


English 12 See the PowerFlex 40 User Manual on CD for more information on parameters<br />

Display Group Parameters<br />

No Parameter MinIMax Display Options<br />

dOOl Output Freq O O Maximum Freq 0 1 Hz<br />

d002 Commanded Freq O O Maximum Freq 0 1 Hz<br />

d003 Output Current O OO Drive Amps x 2 01 Amps<br />

d004 Output Voltage OlDrive Rated Volts 1 VAC<br />

d005 DC Bus Voltage Based on Drive Rating 1 VDC<br />

dOOS Drive Status 0 1 1 Condition True W ill lU Bi1Q<br />

Decelerating Accelerating FOnNard Running<br />

d007 Fault x Code F2IF122 FI<br />

d009<br />

dOlO Process Dispiay 0 00 9999 0 01 1<br />

dOl2 Control Source 0 9 l1il1 Speed Command Bit 0 StartCommand<br />

See P038 9 Jog Freq See P036 9 Jog<br />

d013 Contrlln Status 01 I Input Present W W lU Bi1Q<br />

DB Trans On Stop Input Dir REV In StartFWD In<br />

d014 Dig In Status 0 1 1 Input Present W ill lU Bi1 Q<br />

Digitalin 4 Digitalin 3 Digitalin 2 Digitalin 1<br />

dOl5 Comm Status 01 1 Condition True W ill lU Bi1Q<br />

Comm Error DSI Option Transmitling Receiving<br />

dOl6 Control SW Ver 1 00 99 99 0 01<br />

dOl7 Drive Type 1001 9999 I<br />

dOl8 Elapsed Run Time 0 9999 Hrs 1 10 Hrs<br />

dOl9 Testpoint Data O FFFF I Hex<br />

d020 Analog In O IOV 0 0 100 0 1<br />

d021 Analog In 4 20mA 0 0100 0 0 1<br />

d022 Output Power O OO Drive Power x 2 0 01 kW<br />

d023 Output Powr Fctr 0 0 180 0 deg 0 1 deg<br />

d024 DriveTemp 0 120 degC 1 degC<br />

d025 Counter Status 0 9999 1<br />

d026 Timer Status 0 0 9999 0 1 Sees<br />

d028 Stp Logic Status 07 1<br />

d029 Torque Current O OO Drive Amps x 2 0 01 Amps<br />

Smart Start Up with Basic Program Group Parameters<br />

The PowerFlex 40 is designed so that start up is simple and efficient The Program Group<br />

contains the most commonly used parameters<br />

QJ Stop drive before changing this parameter<br />

No Parameter IMlnlMax Display Options Default<br />

P031 Motor NP Volts 120 Drive Rated Volts 1 VAC Based on Drive Rating<br />

QJ Set to the motor nameplate rated volts<br />

P032 Motor NP Hertz 115 400 Hz 1 Hz 60 Hz<br />

QJ Set to the motor nameplate rated frequency<br />

P033 MotorOL Current 10 0 Drive Rated Ampsx2 0 1 Amps Based on Drive Rating<br />

Set to the maximum aiiowable motor current<br />

P034 Minimum Freq 10 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

Sets the lowest frequency the drive will output<br />

continuously<br />

P035 Maximum Freq 10 400 Hz I Hz 60 Hz<br />

QJ Sets the highest frequency the drive will output<br />

P036 Start Source 10 6 0 Keypad I<br />

QJ<br />

Sets the control scheme used to start the drive<br />

1<br />

When active the Reverse key isaiso active<br />

unless disabled by A095 Reverse Disable<br />

1 3 Wire<br />

2 2Wire<br />

3 2 W Lvi Sens<br />

4 2 W Hi Speed<br />

5 Comm Porf<br />

6 Momt FWDIREV<br />

0


See the PowerFlex 40 UserManual on CD for more information on parameters English 13<br />

QJ Stop drive before changing this parameter<br />

No Parameter IMinlMax Display Options<br />

P037 Stop Mode 10 9 o Ramp CP1<br />

1 Coast Cp<br />

0<br />

l<br />

Active stop mode for all stop sources eg 2 ke6Pad DC Brake Cp I<br />

run forward I 1<br />

O Terminal 02 run reverse<br />

3 DCBrkAuto CF l<br />

Terminal 03 RS485 port exceptas I<br />

noted below<br />

4<br />

Important O Terminal 01 is always a coast to<br />

5<br />

stop input except when P036 Start Source is<br />

Ramp<br />

Coast<br />

set<br />

6<br />

for 3 Wire control When<br />

DC Brake<br />

in I three wire control O 7<br />

Terminal 01 is controlled by P037 Stop Mode<br />

8<br />

DC BrakeAuto<br />

Ramp EM B CP<br />

9 Ramp EM Brk<br />

1 Stop input also clears active fault<br />

P038 Speed Reference o Drive Pof 0<br />

107 I<br />

Sets the lnternaIFreq<br />

source of the speed reference to the drive<br />

2 0 1 OV Input<br />

Important When A051 orA052 Digitallnx Sel is<br />

3 4 20mA Input<br />

set to option 2 4 5 6 13 or14 and the digital 4 Preset Freq<br />

input is active A051 A052 A053 orA054 will<br />

5 Comm Port<br />

override the speed reference commanded by this<br />

6 Stp Logic<br />

parameter Refer to Chapter I of the PowerFlex 40<br />

7 Anlg In Muir<br />

UserManual on CD for details<br />

Default<br />

P039 Accel Time IJ 10 0 600 0 Secs 0 1 Secs 10 0 Secs<br />

Sets the rate of accel for all speed increases<br />

P040 Decel Time 1<br />

10 1600 0 Secs 0 1 Secs 10 0 Secs<br />

Sets the rate of decel for all speed decreases<br />

P041 ResetTo Defalts 101 o Ready idle 0<br />

QJ Resets all parameter values tofactory defaults<br />

I Factory Rset<br />

P042 Voltage Class 12 3 2 Low Voltage 480V<br />

QJ Sets thevoltage class of 600Vdrives 3 High Voltage 600V<br />

Advanced Group Parameters<br />

No Parameter MinIMax Display Options Default<br />

A051 Digitalin I Sel 0 26 o Not Used 13 IOV In Ctrl 4<br />

I O Terminal 05 1 Acc Dec 2 14 20mA In Ctrl<br />

A052 Digltalln2 Sel 2 Jog 15 PID Disable 4<br />

I O Terminal 06 3 Aux Fault 16 MOP Up<br />

A053 Digitalln3 SelJ 4 Preset Freq 17 MOP Down 5<br />

I OTerminal 07 5 Local 18 Timer Start<br />

A054 Digitalln4 SelJ 6 Comm Port 19 Counter In 11<br />

QJ I O Terminal 08 7<br />

8<br />

Clear Fault<br />

RampStop CP<br />

20<br />

21<br />

Reset Timer<br />

Reset Countr<br />

9 CoastStop CP 22 Rset Tim Cnt<br />

10 DClnjStop CP 23 Logic Inl<br />

11 Jog Forward 24 Logic In2<br />

12 Jog Reverse 25 Current Lmt2<br />

26 Anlg Invert<br />

A055 Relay Out Sel 0 22 o Ready Fault 11 Logic in l 0<br />

1 At Frequency 12 Logic In 2<br />

2 MotorRunning 13 Logic 1 2<br />

3 Reverse 14 Logic 1 or 2<br />

4 Motor Overld 15 StpLogic Out<br />

5 Ramp Reg 16 Timer Out<br />

6 Above Freq 17 Counter Out<br />

7 Above Cur 18 Above PF Ang<br />

8 Above DCVolt 19 Anlg In Loss<br />

9 Retries Exst 20 ParamControl<br />

10 Above Anlg V 21 NonRec Fault<br />

22 EM Brk Cntrl<br />

A056 Relay Out Level 0 0 9999 0 1 0 0<br />

A058 Opto Outl Sel 0 22 o Ready Fault 11 Logic In l 2<br />

A061 Opto Out2 SelJ 1 At Frequency 12 Logic In 2 1<br />

2 MotorRunning 13 Logic 1 2<br />

3 Reverse 14 Logic 1 or 2<br />

4 Motor Overld 15 StpLogic Out<br />

5 Ramp Reg 16 Timer Out<br />

6 Above Freq 17 Counter Out<br />

7 Above Cur 18 Above PF Ang<br />

8 Above DCVolt 19 Anlg In Loss<br />

9 Retries Exst 20 ParamControl<br />

10 Above Anlg V 21 NonRec Fault<br />

22 EM Brk Cntrl<br />

3


English 14 See the PowerFlex 40 User Manual on CD for more information on parameters<br />

No Parameter IMinlMax Display Options Default<br />

A059 Opto Out1 Level 0 9999<br />

10 10 1 A062 Oplo Out2 LevelJ<br />

0 0<br />

A055 A058 A061 Setting A056 A059 A062 MinIMax<br />

6 01400 Hz<br />

7<br />

01180<br />

8 01815 Volts<br />

10 0 100<br />

16<br />

0 19999 Sees<br />

17 1 9999 Counts<br />

18<br />

20 011<br />

1 180degs<br />

A064 Opto Out LogicJ 10 3 11 0<br />

AD64 Option OptoOul1Loglc OPto Out2 Logic<br />

0 NO Normal Open NO Normal Open<br />

1 NC Normal Closed NO Normal Open<br />

2 NO Normally Open NC Normal Closed<br />

3 NC Normal Closed NC Normal Closed<br />

A065 Analog Oul SelJ 10 20 II 0<br />

Option Output Renge Minimum Output Value<br />

Maximum Output Value<br />

Analog Out High<br />

o OutFreq 010 0 10V OV OHz POl5 MaKimum Freql 0 10V<br />

1 OutCurrO 10 0 10V OV 0 Amps 200 Drive Raled FLA 0 10V<br />

2 OutVoII 010 0 10V OV 0 Volts 120 Drive Rated Output Volts 0 10V<br />

3 Outf owrO l0 010V OV OkW 200Drive Rated Power 010V<br />

4 OeteO 10 0 10V OV OOOO 65535 Hex FFFF 0 10V<br />

5 OutFreq 020 020mA OmA OHz P035 IMaxlmum Freq 020 mA<br />

6 OutCurr 020 020mA OmA OAmps 200 Drive Rated FlA 020mA<br />

7 OutVoII 0 20 020mA OmA OVolts 120 Drive Rated Output Volts 0 20 mA<br />

8 Outf owr020 020mA OmA OkW 200 Drive Rated Power 020mA DIP Switch Position<br />

9 stOata020 020mA QmA OOOO 65535 Hex FFFF 020mA 10 OutFreq4 2Q 4 20mA 4mA OHz P035f aximum Freq 020mA<br />

11 OutCurr4 20 4 20mA 4mA OAmps 200 Drive Rated FlA 020mA<br />

12 OutVoIl4 20 4 20mA 4mA OVolts 120 DriveRated Output Volts 0 20mA<br />

13 Outf owr 4 20 4 20mA 4mA OkW 200 DriveRated Power 020mA<br />

14 TslOala 4 20 4 20mA 4 mAs 0000 65535 Hex FFFF 020mA 15 OutTorq 010 0 10V OV 0 Amps 200 Drive Rated FLA 0 10V<br />

16 OutTorq 020 0 20mA OmA OAmps 200 Drive Rated FlA 020mA<br />

17 OutTorq 4 20 4 20mA 4mA OAmps 200 Drive Rated FlA 020mA<br />

18 Sotpnt 0 10 010V OV O 100 0 Setpolnt Setting 010V<br />

19 Setpn 0 20 0 20 mA QmA O 100 0 Selpelnl Setting o20mA<br />

2Q Setpnt 4 20 4 20 mA<br />

O 100 0<br />

4mA<br />

Selpelnl Setting 020mA<br />

A066 Analog Out HighJ 0 800 1 100<br />

A067 Accel Time 2J 0 0 600 0 Secs 0 1 Secs 20 0 Secs<br />

A068 Decel Time 2J 0 1 600 0 Secs 0 1 Secs 20 0 Secs<br />

A069 Internal Freql 0 0 400 0 Hz 0 1 Hz 60 0 Hz<br />

A070 Preset Freq OJI 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A071 Preset Freq I I 5 0Hz<br />

A072 Preset Freq 2J 10 0 Hz<br />

A073<br />

A074<br />

Preset Freq<br />

Preset Freq 3j<br />

20 0 Hz<br />

4 30 0 Hz<br />

A075 Preset Freq 5J 40 0 Hz<br />

A076 Preset Freq 6J 50 0 Hz<br />

ADn Preset Freq 7 60 0 Hz<br />

1<br />

To activate Preset Freq OJ set P038 Speed ReferenceJ to option 4<br />

O n8j jl fj e<br />

1 On81 1l lj e<br />

2 o n81 t<br />

lj e<br />

3 Frequency Source 2<br />

Aceal J DacetParameter Used<br />

VO Terminal 05 110Terminal 06 110 Terminal07<br />

0 0 0 Prese1 Freq 0 Accel Time 1 I DecelTime 1<br />

1 0 0 PresetFreq 1 Accel Time 1J I Decel TIme 1<br />

0 1 0 Preset Freq 21 Accel Time I Decel Time 2<br />

1 t<br />

0 Preset Freq 31 Accel Time 2 I Decel Time 2<br />

0 0 1 PreselFreq4 Accel Time 111 DecelTime 1<br />

1 0 1 Preset Freq 51 Accel Time1 I DecelTime 1<br />

0 1 1 Preset Freq 61 Accel Time 2J I Decel Time 21<br />

1 1 1 PreselFreq7J Accel Time2 I DecelTime 21<br />

2<br />

When a DigltallnpUlls set to Accel 2 Decel2 and the Input Is active that inputoverrides the settings In thistable<br />

A078 Jog FrequencyJ 1001Maximum FreqJ 10 1 Hz 10 0 Hz


See the PowerFlex 40 User Manual on CD for more information on parameters English 1S<br />

No Parameter MinIMax Display Options Default<br />

A079 Jog AccelIDecel 0 11600 0 Secs 0 1 Secs 10 0 Secs<br />

A080 DC Brake Time 0 0199 9 Secs 0 1 Sees 0 0 Secs<br />

A setting of 99 9 Sees Continuous<br />

AOB1 DC Brake Level O OI Drive Amps x I B 0 1 Amps Amps x 0 05<br />

A082 DB Resistor Sel 0199 o Disabled 2 NoProtection 0<br />

1 Normal RA Res 3 99 of Duty Cycle<br />

Q<br />

A083 S Curve 01100 1 0 Disabled<br />

A084 Boost Select 0114 Settings in of base voltage 8<br />

Only active when A125Torque Pert ModeJ is<br />

set to 0 VlHz<br />

o Custom V1Hz<br />

Variable Toroue Constant Torque<br />

7 4 11 kW<br />

5 15HP<br />

I 30 0 IT 5 0 0 no IR 10 10 0 CT<br />

2 35 0 IT 6 0 0 11 12 5 CT<br />

3 40 0 IT 7 2 5 CT 12 15 0 CT<br />

4 45 0 IT 8 5 0 CT 13 17 5 CT<br />

9 7 5 CT 14 20 0 CT<br />

A085 Start Boost 10 0125 0 0 1 2 5<br />

Only active when A084 Boost Select and AI25 Torque Pert Mode are set to 0<br />

AOB6 Break Voltage 10 01100 0 1 10 25 0<br />

Only active when A084 Boost Select and A125 Torque Pert Mode are set to 0<br />

A087 Break Frequency 10 01400 0 Hz 10 1 Hz 15 0 Hz<br />

Only active when A084 Boost Select and A125 Torque Pert Mode are setto 0<br />

A08B Maximum Voltage 20lRated Volts I VAC Rated Volts<br />

A089 Current Limit IJ O ll Drive Amps x 1 8 0 1 Amps Amps x 1 5<br />

A090 Motor OL Select 012 o No Derate I Min Derate 0<br />

2 Max Derate<br />

A091 PWM Frequency 2 0116 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Auto Rstrt Tries 019 I 0<br />

A093 Auto Rstrt Delay 0 013000 Secs 0 1 Secs 1 0 Secs<br />

A094 Start At PowerUp 011 o Disabletl 1 Enabled 0<br />

Q<br />

A095 Reverse Disable 011 o Rev Enabled 1 Rev Disabled 0<br />

Q<br />

A096 Flying Start En 011 o Disabled I Enabled 0<br />

A097 Compensation 013 o Disabled 2 Mechanical 1<br />

I Electrical 3 Both<br />

A098 SW Current Trip O OI Drive Amps x 2 0 1 Amps 0 0 Disabled<br />

A099 Process Factor 0 11999 9 0 1 30 0<br />

Al00 Fault Clear 012 o Readylldle 1 Reset Faulr 0<br />

Q<br />

2 Clear Buffer<br />

Al01 Program Lock 019999 0 Unlocked 1 Locked 0<br />

Al02 Testpoint Sel 400lFFFF 1 Hex 400<br />

Al03 Comm Data Rate 015 0 1200 3 9600 3<br />

Power to drive must be cycled before any<br />

I 2400 4 19 2K<br />

changes will affect drive operation<br />

2 4800 5 38 4K<br />

Al04 Comm Node Addr 111241 I 100<br />

Power to drive must be cycled before any<br />

changes will affect drive operation<br />

AI05 Comm Loss Action 013 o Fault 2 Stop O<br />

1 Coast Stop 3 Continu Lasr<br />

AI06 Comm Loss Time 0 1160 0 Secs 0 1 5 0<br />

AI07 Comm Format 012 0 RTU 8 N l 3 RTU 8 N 2 0<br />

Power to drive must be cycled before any<br />

changes<br />

1 RTU 8 E 1 4 RTU 8 E 2<br />

will affect driveoperation<br />

2 RTU B O I 5 RTU 8 0 2<br />

A10B Language 1110 1 English 6 Reserved I<br />

2 Fran is 7 portugues<br />

3 Espaiiol B Reserved<br />

4 Italiano 9 Reserved<br />

5 Deutsch 10 Nederlands<br />

Al09 Anlg Out Setpt 0 01100 0 0 1 0 0<br />

Al10 Anlg In 0 1 OV Lo 0 01100 0 0 1 0 0<br />

Q


English 16 See the PowerFlex 40 User Manual on CD for more information on parameters<br />

No Parameter MinIMax Dlsplay Opllons Default<br />

A111 Anlg In 0 10V Hi 0 0 1000 0 1 100<br />

ill<br />

A112 Anlg In4 20mA Lo 0 0100 0 0 1 0 0<br />

ill<br />

r5l Anlg In4 20mA Hi 0 0100 0 0 1 100<br />

A114 Slip Hertz @ FLA 0 010 0 Hz 0 1 Hz 2 0 Hz<br />

A115 Process Time Lo 0 00 99 99 0 01 0 00<br />

A1l6 Process Time Hi 0 00 99 99 0 01 0 00<br />

A117 Bus Reg Mode 0 1 o Disabled 1 Enabled I<br />

AI18 Current Limit 2 O I Drive Amps x 1 8 0 1 Amps Amps x 1 5<br />

A119 Skip Frequency 0 400 Hz 1 Hz o Hz<br />

A120 Skip Freq Band 0 0 30 0 Hz 0 1 Hz 0 0 Hz<br />

A121 Stall Fault TimeJ 0 5 o 60 Seconds 3 360 Seconds 0<br />

I 120 Seconds 4 480 Seconds<br />

2 240 Seconds 5 Fit Disabled<br />

A122 Analog In Loss 0 6 o Disabled 4 Min Freq Ref 0<br />

I Fault F29 5 Max Freq Ref<br />

2 Stop 6 Int Freq Ref<br />

3 Zero Ref<br />

AI23 IOV Bipolar Enbl 0 1 0 Un i Polar In I Bi Polar In 0<br />

AI24 Var PWM Disable 0 1 o Enabled I Disabled 0<br />

AI25 Torque Perl Mode 0 1 0 V Hz I Sensrls Vect 1<br />

AI26 Motor NP FLA O I Drive Amps x 2 0 1 Amps Rated Amps<br />

A127 Autotune 0 2 0 Readyndle 2 Rotate Tune 0<br />

I Static Tune<br />

A128 lR Voltage Drop 0 0 230 0 VAC 0 1 VAC Rated Volts<br />

AI29 Flux Current Reij 0 001Motor NP Volts 0Q1 Amps Rated Amps<br />

A130 PID Trim Hi 0 0 400 0 0 1 60 0<br />

AI31 PID Trim Lo 0 0 400 0 0 1 0 0<br />

AI32 PID Ref Sel 0 8 0 PID Disabled 5 Setpnt Trim 0<br />

1 PID Setpoint 6 0 101 Trim<br />

2 0 1 OV Input 7 4 20mA Trim<br />

3 4 20mA Input 8 Comm Trim<br />

4 Comm Porr<br />

A133 PID Feedback Sel 0 2 o 0 1 OV Input 2 Comm Port 0<br />

I 4 20mA Inpur<br />

AI34 PID Prop Gain 0 00 99 99 0 01 0 01<br />

AI35 PiD Integ Time 0 0 999 9 Secs 0 1 2 0<br />

AI36 PID Diff Rate 0 00 99 99 I Secs 0 01 0 00<br />

AI37 PID Setpoint 0 0 1000 0 1 0 0<br />

A13B PID DeadbandJ 0 0 10 0 0 1 0 0<br />

A139 PID Preload 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A140 Stp Logic 0 7J 0001 bAFF 4 Digits 00F1<br />

A147 Fora list of digit options refer to the PowerFlex 40<br />

UserManual on the CD supplied with the drive<br />

A150 Stp Logic Time 0 7 0 0 999 9 Secs 0 1 Secs 30 0 Secs<br />

A157<br />

A160 EM Brk Off Delay 0 01 10 00 Secs 0 01 Secs 2 00 Secs<br />

A161 EM Brk On Delay 0 01 10 00 Secs 0 01 Secs 2 00 Secs<br />

A162 MOP Reset Sel 0 1 o Zero MOP Ref 1 Save MOP Ref I


Fault Codes<br />

English 17<br />

To clear a fault press the Stop key cycle power or set AIOO Fault Clear to I or<br />

2<br />

1<br />

No Fault Description<br />

F2 Auxiliary Inputll Check remote wiring<br />

F3 Power Loss Monitor the incoming AC line for low voltage or line power interruption<br />

F4 UnderVoltagelll Monitor the incoming AC line for low voltage or line power interruption<br />

FS OverVoltagel1T Monitor the AC line for high line voltage or transient conditions Bus overvoltage can also be<br />

caused by motor regeneration Extend the decel time or install dynamic brake option<br />

F6 Motor Stalled 1 Increase Accel Time xl or reduce load so drive output current does not exceed the current set<br />

by parameter A089 Current Limit<br />

F7 Motor Overloadl1 An excessive motor load exists Reduce load so drive output current does not exceed the<br />

current set by parameter P033 Motor OL Current<br />

F8 Heatsink OvrTmpll Check for blocked or dirty heatsink fins Verify that ambient temperature has not exceeded 40C<br />

104 Ffor IP 3nNEMA1UL Type 1 instaI onsor 5OC 122 F forOpen type installations<br />

Check fan<br />

F12 HW OverCurrent Check programming Check for excess load improper DC boost setting DC brake volts set too<br />

high orother causes of excess current<br />

F13 Ground Fault Check the motor and external wiring to the drive output terminals for agrounded conditiOn<br />

F29 Analog Input Loss 1 An analog input is configured to fault on signal loss A signal loss has occurred<br />

F33 Auto RstrtTries Correct the cause of the fault and manually clear<br />

F38 Phase U to Gnd Check the wiring between the driveand motor Check motor for grounded phase<br />

F39 Phase V to Gnd Replace drive iffault cannot be cleared<br />

F40 Phase W to Gnd<br />

F41 Phase UV Short Check the motor and drive output terminal wiring for a shorted condition<br />

F42 Phase UW Short Replace drive iffault cannot be cleared<br />

F43 Phase VW Short<br />

F48 Params Defaulted The drive was commanded to writedefault values to EEPROM Clear the fault orcycle powerto the drive Program thedrive parameters as needed<br />

F63 SW OverCurrent 1 Check load requirements and A098 SW Current TripI setting<br />

F64 Drive Overload Reduce load orextend Accel Time<br />

F70 Power Unit Cycle power Replace drive if fault cannot be cleared<br />

F71 Net Loss The communication network has faulted<br />

FaD SVC Autotune The autotune tunction was either cancelled by the userOf failed<br />

F81 Comm Loss If was adapter not intentionally disconnected check wiring to the porI Replace wiring port<br />

expander adapters orcomplete drive as required Check connection An adapter was<br />

intentionally disconnected Turn off using AIDS Comm Loss Action<br />

FWD Parameter Checksum Restore factory defaults<br />

F122 IO Board Fail Cycle power Replace drive if fault cannot be cleared<br />

I<br />

Auto Reset Run type fault Configure with parameters A092 and A093


English 18<br />

Drive Dimensions<br />

PowerFlex 40 Frames Ratings are in kW and HP<br />

Frame 120V AC 1 Phase 240V AC 1 Phase 240V AC 3 Phase 480V AC 3 Phase 600V AC 3 Phase<br />

B 04 0 5 04 0 5 0 4 0 5 2 2 3 0 0 4 0 5 2 2 3 0 0 75 10 4 0 5 0<br />

0 75 1 0 0 75 10 075 10 37 5 0 075 10 4 0 5 0 1<br />

1 1 15 1 5 2 0 1 5 2 0 1 5 2 0 2 2 3 0<br />

512 0l<br />

r5<br />

C 2 2 3 0 5 5 7 5 5 5 7 5 11 0 15 0 5 5<br />

7 5 10 0 7 5 10 0 7 5 10 0<br />

r AD 11<br />

m m<br />

CJ<br />

oc5o bo<br />

0 lOO<br />

rIl Gl<br />

11 5 5 0 22<br />

5<br />

0<br />

c<br />

PowerFlex 40 AC Drive<br />

Dimensions arein millimeters and inches<br />

Weights arein kilograms and pounds<br />

110 15 0<br />

E<br />

Ship<br />

1 A B C 0 E F Weight<br />

B 100 180 136 87 168 87 4 2 2<br />

3 94 7 09 5 35 343 6 61 344 4 9<br />

C 130 260 180 116 246 4 3<br />

5 1 10 2 7 1 4 57 9 7 9 5<br />

Communication RFI Filter IP 30 NEMA 1UL Type 1 Option Kits<br />

6<br />

Al CIl 222<br />

0 B7<br />

m<br />

m<br />

o<br />

E<br />

B Frame C Frame<br />

is Option Drive Drive<br />

A Comm Cover 25 0 98 25 0 98<br />

B EMC Line Filter 50 1 97 60 2 36<br />

C EMC Line Filter 229 9 02 309 12 17<br />

D IP30INEMA l UL 33 130 60 2 36<br />

Type 1<br />

IP30INEMA IUL 64 2 52 60 2 36<br />

Type I for Comm<br />

Cover<br />

B Frame 22 JBAB C Frame 22 JBAC<br />

B Frame 22 JBCB<br />

used with Comm Cover<br />

108 7 42B<br />

92 2 3 63<br />

692 272<br />

57 1BO<br />

220 B7<br />

U S Allen Bradley Drives Technical Support<br />

Tel 1 262 512 B176 Fax 1 262 5122222 Email support@driveSJa rockwellcom Onllne www ab comlsupporVabdrtves<br />

Rockwell<br />

Publication 22B QSOOI B EN P January 2004 Automation<br />

Supersedes October 2002 Copyright@2004 Rockwell Automation Inc All ri9hts reserved Prinled in TBiwan<br />

152 2


tab<br />

QllV<br />

PowerFlex 40<br />

Frequenzumrichter<br />

FRN 2 xx<br />

In dieser Kurzanleitung wird beschrieben wie Sie den PowerFlex 40<br />

Kurzanleitung<br />

Frequenzumrichter installieren in Betrieb nehmen und programmieren<br />

Die hierin enthaltenen Informationen sind jedoch Iilln Ersatz fijr das<br />

Benutzerhand buch und sind nurfijr qualifiziertes FU Wartungspersonal<br />

vorgesehen<br />

Genauere lnfonnationen iiber den PowerFlex 40 einschlieBlich EMV Hinweise<br />

Anwendungsaspekte und die entsprechenden sicherheitstechnischen Hinweise<br />

finden Sie im Benutzerhandbuch des PowerFlex 40 Publikation 22B UMOOI<br />

aufder demFU beigepackten CD oder unter wwwab com manuals dr<br />

Allgemeine Vorsichtshinweise<br />

ACHTUNG Der FU enthalt Hochspannungskondensatoren die sich erst<br />

nach gewisser Zeit nach dem Trennen yom Netz entladen VorArbeiten am<br />

Frequenzumrichter muss sichergestellt werden dass die Netzspannung vonden<br />

Netzanschliissen R S T Ll L2 L3 getrennt isDrei Minuten warten bis<br />

die Kondensatoren sich aufeine ungefahrliche Spannung entladen haben<br />

Nichtbeachtung kann schwere oder todliche Verletzungen zur Folge haben<br />

Eine dunkle LED Anzeige bedeutet nicht dass sich die Kondensatoren aufeine<br />

entladen haben<br />

ungefahrliche Spannung<br />

ACHTUNG Die sachwidrige Verwendung des Parameters A092 Fhl<br />

Neustartvers oder A094 Autostart kannzu Schaden am Gerat und oder<br />

Verletzungen fiihren Diese Funktionen sind nur unter Beachtung der lokal<br />

national und international geltenden Gesetze Standards Vorschriften und der<br />

in der Industrie geltenden Bestimmungen anzuwenden<br />

ACHTUNG Die Planung und Ausfiihrung der Installation sowie die<br />

Inbetriebnahme und spatere Wartung des <strong>Systems</strong> sollte nur von qualifiziertem<br />

Fachpersonal ausgefiihrt werden das mitFrequenzumrichtern und den daran<br />

angeschlossenen Maschinen vertraut is Zuwiderhandlungen konnen zu<br />

Personen undoder Sachschaden fiihren<br />

ACHTUNG Dieser FU enthalt Teile und Baugruppen die empfindlich auf<br />

elektrostatische Entladung reagieren Bei der Installation Prtifung und Wartung<br />

oder Reparatur des Gerats mtissen deshalb VorsichtsmaBnahmen getroffen<br />

werden urn soleh eine elektrostatische zu Entladung verhindern da<br />

Komponenten andernfalls beschadigt werden konnen Sollten Sie mit dem<br />

nicht vertraut sein ziehen Sie<br />

Verfahren zur Verhinderung statischer Entladung<br />

bitte die A B Publikation 8000 4 5 2 Guarding Against Electrostatic Damage<br />

oder ein Handbuchheran<br />

entsprechendes<br />

ACHTUNG Wird ein FU nicht ordnungsgemaB eingesetzt bzw installiert<br />

konnen Komponenten beschadigt und die Lebensdauer des Produkts dadurch<br />

verktirzt werden Verdrahtungs bzw Anwendungsfehler wie z B<br />

unzureichende MotorgroBe falsche oder unzureichende Netzversorgung und zu<br />

hohe Umgebungstemperaturen konnen zu Fehlfunktionen im System fiihren


Deutsch 2<br />

Erlauterungen zum Aufstellen des FUs<br />

Befestigen Sie den FU aufrecht an einer flachen senkrechten und ebenen<br />

Fliiche<br />

BaugroBe SchraubengroBe Anzugsmoment DIN Schiene<br />

B M4 8 32 1 561 96 Nm 35mm<br />

C M5 10 24 2 452 94 Nm<br />

Oas Kilhlgeblase vorStaub und Metallpartikeln schiltzen<br />

Keiner korrosiven Umgebung aussetzen<br />

Vor Feuchtigkeit und direktem Sonnenlicht schiltzen<br />

Beirn Aufstellen zu beachtende Mindestabstiinde<br />

Einbauabmessungen linden Sie auf Seite 16<br />

v 0 V<br />

120mm<br />

odobo odobo<br />

61600<br />

120 mm<br />

0 0<br />

0 0<br />

o o<br />

oo<br />

I II I<br />

BefestigUngSoPtion A<br />

Kein Abstand zwischen<br />

FUs erlorderlich<br />

Befestigungsoption B<br />

Umgebungs Betriebstemperatur<br />

rl<br />

odobo<br />

0<br />

oo<br />

R<br />

25 mm<br />

V 0<br />

120mm<br />

odobo<br />

G<br />

o 0<br />

oo<br />

120mm<br />

I II I<br />

Umgebungstemperatur Schutzart Beim Aufstellenzu beachtende<br />

Minimum Maximum Mindestabstande<br />

40 C<br />

IP 20 offen<br />

Befestigungsoption A verwenden<br />

10 C IP 30 NEMA I UL Typ 11l Belestigungsoption B verwenden<br />

50 C IP 20 offen<br />

Befestigungsoption B verwenden<br />

1<br />

Nennwert ertordert die Installation des PowerFlex 40 0ptionskits IP 30 NEMA I UL Typ 1<br />

Allgemeine Voraussetzungen fur die Erdung<br />

Erlauterung<br />

Wichtig Die Brucke MOV Erde sollIe enffernt werden wenn der FU<br />

in einem nicht geerdeten Verteilungssystem installiert wird<br />

Ziehen Sie die Schraube nach dem Enffernen der Brucke fest<br />

der EU Richtlinien<br />

D<br />

00000<br />

6600<br />

Einzelheiten zur Einhaltung der Niederspannungs und der EMVRichtIinie<br />

finden Sie im PowerFlex 40 Benulzerhandbuch aufder im Lieferumfang des FUs<br />

enthaltenen CO


Sic erungen und Leistungsschalter TechnischeDaten<br />

22B V2P3N104 04 2 3 90132 1 15 9 0 15 140M C2E C16 100 C12 30<br />

22B V5PON104 0 75 5 0 90 132 245 20 3 35 140M D8E C20 100C23 56<br />

22B V6PON104 1 1 6 0 90132 3 0 24 0 40 140M FBE C32 l00C37 70<br />

200240 V AC 10 Elnphasen l<br />

eingang 0230 VAcOretphasenausgang<br />

22B A2P3N104 0 4 2 3 180 264 1 15 6 0 10 140M C2E B63 100 C09 30<br />

22B A5PON104 0 75 5 0 180 264 2 45 12 0 20 140M C2E C16 100 C12 55<br />

22B A8PON104 1 5 8 0 180 264 4 0 18 0 30 140M D8E C20 100C23 80<br />

22B A012Nl04 2 2 12 0 180264 5 5 25 0 40 140M F8E G32 100C37 110<br />

200240 VAC 10 Oreiphasenelngang 0230 V AcOreiphasenausgang<br />

22B B2P3N104 0 4 2 3 180 264 1 15 2 5 6 140M C2E B40 100 C07 30<br />

22B B5PON 1 04 0 75 5 0 180 264 2 45 5 7 10 140M C2E Cl0 100C09 55<br />

22B B8PON 1 04 1 5 8 0 180264 4 0 9 5 15 140M C2E CI8 100C12 80<br />

22B B012N104 2 2 12 0 180264 5 5 15 5 25 140M C2E C16 100C23 115<br />

22B B017N104 3 7 17 5 180264 8 6 21 0 35 140M F8E C25 100 C23 165<br />

22B B024Nl04 5 5 24 0 180 264 11 8 28 1 40 140M F8E C32 100 C37 226<br />

22B B033Nl04 7 5 33 0 180 264 16 3 34 6 60 140M G8E C45 100C60 290<br />

380 480 V AC 10 Oreiphaseneingang 0460 V AcOretphasenausgang<br />

22B D1P4Nl04 04 1 4 342 528 1 4 I B 3 140M C2E B25 100C07 30<br />

22B D2P3N104 0 75 2 3 342 528 2 3 3 2 6 140M C2E B40 100 C07 40<br />

22B D4PoNl04 1 5 4 0 342 528 4 0 57 10 140M C2E B63 100C09 60<br />

22B D6PON104 2 2 6 0 342 528 5 9 7 5 15 140M C2E Cl0 100 C09 90<br />

22B D010N104 4 0 10 5 342 528 10 3 13 0 20 140M G2E C16 100C23 150<br />

22B D012N104 5 5 12 0 342 528 11 8 14 2 25 140M D8E C20 100C23 160<br />

22B D017N104 7 5 17 0 342 528 16 8 184 30 140M D8E C20 100 C23 200<br />

22B D024Nl04 11 0 24 0 342 528 23 4 26 0 50 140M F8E C32 100 00 285<br />

46tHiOO VAC 10 Drelphasenelngangll 575 VAC Drelphasenausgang<br />

22B E1P7N104 0 75 17 414 660 2 1 2 3 6 140M C2E B25 100 C09 40<br />

22B E3PON104 1 5 3 0 414 660 3 65 3 8 6 140M C2E B40 100 C09 60<br />

22B E4P2Nl04 2 2 4 2 414 660 5 2 5 3 10 140M C2E B63 100 C09 90<br />

22B E6P6N104 4 0 6 6 414 660 8 1 8 3 15 140M C2E Cl0 1 OO C09 150<br />

22B E9P9N104 5 5 9 9 414 660 12 1 11 2 20 140M C2E G16 100C16 160<br />

22B E012N104 7 5 12 2 414 660 14 9 13 7 25 140M C2E C16 100 C23 200<br />

22B E019Nl04 11 0 19 0 414 660 23 1 24 1 40 140M D8E C25 100 C30 285<br />

Deutsch 3<br />

1<br />

200 240 Y AC 1 Phasen FUs sind auBerdem mil einem integrierten EMY Filter erhiiltlich<br />

2<br />

Bestellnummer Ergiinzung von Nl04 in N114 geiindert<br />

Weitere Informationen zur Bestimmung der fUr Ihre Anwendung ben6tigten Baugr6Be undAusschaltleistung<br />

entnehmen Sie bille der Motorschutzschalter Bulletin 140M Auswahlanleitung Publikation 140M<br />

SG001


Deutsch 4<br />

Programmierl7arer Ausgang Relaiskontakt Form C<br />

Ohmscha Last 3 0 A bai 30 V DC 3 0 A bai 125 V AC 3 0 A bai 240V AC<br />

Induktivlast 0 5 A bei 30 V DC 0 5 A bal125 V AC 0 5 A bal240 V AC<br />

Sicherungen und Leistungsschalter<br />

Emplohiener Sicherungslyp UL Klasse J CC Toder Typ BS88 600 V 550 V oder glaichwertig<br />

Emplohiene Leislungsschafter HMCP Leistungsschalter odar gleichwertige<br />

Schutzvorrichtungen<br />

Molorschutz 12t Obertastschulz 150 lOr 60 s 200 fUr 3 s bietat Sehulz gam Klassa 10<br />

Ul5OBC C CSA22 2 C<br />

EMC Di 8m36<br />

LV EN50178 EN60204<br />

EMC EN618QO 3 EN5008I 1 ENSOO82 2<br />

OptischaAusg nga<br />

30 V DC 50 mA<br />

Induktionsfral<br />

f6eW6<br />

n 0 Bil<br />

420 mA 525 Ohm Max<br />

Oberslrom 200 Hardware Grenza 300 Impulsgrenze<br />

Oberspannung 100120 V AC Eingang Auslosung bai 405 V DC Busspannung siner Netzeingangsspannung<br />

lentspricht<br />

von 150 V<br />

200240 V AC Eingang Auslosung bal405 V DC Busspannung entsprieht einer 380 460 V AC Eingang<br />

Netzelngangsspannung von 290 V AC<br />

Auslosung bai 810 V DC Busspannung enlsprieht einar 460 600 V AC Eingang<br />

Netzeingangsspannung von 575 V AC<br />

Auslosung bei 1005 V DC Busspannung entspricht einer Natzeingangsspannung von 711 V A I<br />

lentsPrieht<br />

Unlerspannung 100120 V AC Eingang Auslosung bei 210 V DC 200240 V AC Eingang<br />

Busspannung siner Netzeingangsspanhung yon 75 V AC<br />

Auslosung bei 210 V DC Busspannung entsprieht siner 380 480 V AC Eingang<br />

Netzeingangsspannung von 150 V<br />

Auslosung ACI<br />

bei 390 V DC 46H00 V AC Eingang<br />

Busspannung entsprieh1 einer Netzeingangsspannung yon 275 V AC<br />

Wenn P042 3 ertolgt die Hochspannungsauslosung bei elner Busspannung yon 487 V DC<br />

Netzeingangsspannung von 344 V AC<br />

Wenn P042 2 ertolgt die NiedatSpannungsauslosung bei einar Busspannung von 390V DC<br />

Natzeingangsspannung von 275 V AC<br />

Steuerverm6gen beiNelzauslail Minlmale Toleranz batrtigt 0 5 s Iypischer Wortbatragt 2 s<br />

FehlerlreieNelzauslall Oberl7rOckung 100 ms<br />

Dynamische Bremsung<br />

Aile FUs mlt ailan Nennwerten Sind mit intamem Brems IGBT ausgestattet Bestellinformationen fOr DB Widarstandesind Anhang B des aulder CO<br />

anthailanen Powerflax4D Benulzerhandbuchs zu entnehman<br />

ACl


Netzanschluss<br />

Verdrahlungsnennwerte<br />

Nicht abgeschirmt 600 V 75 C THHNffHWN<br />

Abgeschirmt 600 V 75 C oder 90 C RHH RHW 2<br />

Abgeschirmter Kabelkanal mit Nennwert 600 V 75 C oder 90 C<br />

RHH RHW 2<br />

Klemmenblock fOr den Netzanschluss<br />

Klemme 1 Beschreibung<br />

AIL 1 S L2 l Phasen Eingang<br />

AIL 1 S L2 T L3 3 Phasen Eingang<br />

Uff1<br />

Zu Motor Uff1<br />

Empfohlener Kupferdrahl<br />

Deutsch S<br />

04mm isoliert fur lrockene<br />

Standorte<br />

Anixter OLF 7xxxxx<br />

Belden 29501 29507 oder<br />

gleichwertig<br />

Anixter 7V 7xxxx 3G<br />

Shiiwflex 2ACD 3ACD oder<br />

gleichwertig<br />

11<br />

Zwei Motorkabel<br />

Vff2 Zu Motor Vff2 vertauschen um<br />

Drehrichtung zu iindern<br />

Wff3 Zu Motor Wff3<br />

P2 PI<br />

DC Bus Induktoranschluss nurbei FUs der BaugroBe C<br />

Beim FU der BaugroBe C ist bei Anlieferung zwischen den Klemmen<br />

P2 und PI eine BrOcke installiert Entfernen Sie diese BrOcke nur<br />

wenn ein DC Bus Induktor angeschlossen werden soil Der FU kann<br />

nicht ohne eine angeschlossene Brucke oder einen angeschlossenen Induktor<br />

gestartet werden<br />

DCt DC DC Busverbindung<br />

BRt BR<br />

@ Schutzerde PE<br />

Anschluss des Widerstands fUr die dynamische Bremse<br />

1 Wichtig Klemmenschrauben konnen sich wiihrend des Transports losen Stellen Sie vor dem<br />

Einschalten des FUs slcher dass aile Klemmenschraubenmil dem empfohlenen Drehmoment<br />

angezogen sind<br />

Klemmenblock fOr den Netzanschluss Technische Daten<br />

BaugroBe Maximaler Minimaler Drehmoment<br />

Leiterquerschnill 2<br />

Leiterquerschnill 2<br />

B 5 3 mm2 AWG 10 1 3 mm2 AWG 16 1 7 2 2 Nm<br />

C 84 mm2 AWG 8 1 3 mm2 AWG 16 2 9 3 7 Nm<br />

2<br />

Die angegebene Leiterstiirke bezeichnet Maximal bzw MinimalgroBen die in den Klemmenblock<br />

passen es handelt sich nicht um Empfehlungen


Deutsch 6<br />

Netzeigenschaften<br />

Netzeigenschaften<br />

AbhilfemaBnahme<br />

Niedrige Impedanz weniger als 1 Reaktanz Netzdrossel l<br />

GroBer als 120 kVA Netztransformator<br />

oder Trenntransformator<br />

oder Businduktor installieren nur<br />

bei FUs mit 5511 kW<br />

Leitung vertiigt iiber Netzdrossel<br />

Blindleistungskompensationskondensatoren oder Trenntransformator<br />

Hiiufige Netzunterbrechungen<br />

Kurzfristige Spannungsspitzen von mehr als 6000 Y<br />

Blitzschlag<br />

Leiter Erde s annung iiberschreitet 125 dernormalen MOY Briicke zu Erde entfernen<br />

Leiter Leiter pannung und Trenntransformator mit<br />

Ungeerdetes Verteilungssystem<br />

geerdeter Sekundiirwicklung<br />

installieren<br />

240 Y offene Delta Konfiguration<br />

1<br />

Netzdrossel installieren<br />

Bestellinformationen fiir ZubehOrteile sind Anhang B des auf der CD enthaltenen<br />

PowerFlex 40 Benutzerhandbuchs zu entnehmen<br />

Empfohlene E1A Verdrahtung 2<br />

Leitertyp en Beschreibung Minimale<br />

Nennisolierspannung<br />

Belden 8760 9460<br />

oder gleichw<br />

0 8 mm2 AWGI8 verdrillt 100<br />

Kabel mit Ableiter<br />

abgeschirmtes<br />

300 V<br />

0 8 mm2 AWG 18 3 adrig abgeschirmt nurfiir<br />

60 Grad C<br />

Belden 8770<br />

oder gleichw Fernpoti<br />

140Grad F<br />

2 Wenn die Kabel kurz sind und sich in einem Schaltschrank befinden der keine empfindiichen<br />

Schaltungen enthiilt ist zwar keine Abschirmung fiir diese Kabel ertorderlich jedoch wird diese<br />

empfohlen<br />

E1A Klemmenblock Technische Daten<br />

BaugroBe Maxlmaler Minimaler Drehmoment<br />

3<br />

Leiterquerschnltt Leiterquerschnltt 3<br />

B und C 1 3 mm2 AWG 16 0 13 mm2 AWG 26 0508 Nm<br />

3 Die angegebene Lelterstiirke bezeichnet Maximal bzw MinimalgraBen die in den Klemmenblock<br />

passen es handelt sich nicht um Empfehlungen<br />

Empfohlene maximale Langen fur Netz und Steuerkabel sind dem aufder CD<br />

enthaltenen PowerFJex 40 Benutzerhandbuch zu entnehmen


SchlieBerrelais<br />

Relais Bezugspotenzial<br />

Steuerein und ausgange<br />

Steuerleitun9sblockdiagramm<br />

Offnerreiais<br />

Ohmscher Widersland<br />

lndulctiv<br />

AktivierungsbrGcka 4<br />

R1<br />

R2<br />

R3<br />

I I<br />

i<br />

30V DC<br />

50mA<br />

Indu tions rei<br />

24 V<br />

05<br />

06<br />

07<br />

08<br />

09<br />

11<br />

Deutsch 7<br />

Typlsche SRC Typlsche SNK<br />

1<br />

Stopp<br />

Verdrahtung Verdrahtung<br />

wUi<br />

StarWorwartslauf 2<br />

Oig Eingang 2<br />

Dig Eingang 3<br />

Oig Eingang 4<br />

Opto Bezugspotenzial<br />

24V DC<br />

16v 10V DC<br />

I<br />

I<br />

I<br />

12<br />

0 10V oder 10V<br />

Eingang<br />

13<br />

Anai09 S0llw<br />

I I<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

Poti muss<br />

4 20 mA Eing 10 kOhm<br />

2 W Min sein<br />

Analogausgang<br />

0 10V Wahl Analogar Ausgang<br />

8<br />

VO 20 mA 01 02 03<br />

V<br />

04<br />

I<br />

Aktivierungsbrucka<br />

C1DR2 C1DR3 SRC<br />

J 13 14 15 16 17 18 1<br />

4<br />

V<br />

05 06<br />

ENBL 30<br />

07 08 09<br />

1<br />

Wichtig An EA Klemme 01 ertolgt nur dann kein Auslauf<br />

wenn P036 Startquelle auf 3 Draht Steuerung eingestellt<br />

ist Bei der 3 Draht Steuerung wird EA Klemme 01 uber<br />

P037 Stoppmodus gesteuert Aile weiteren Stoppquellen<br />

werden uber P037 Stoppmodus gesteuert<br />

2<br />

3<br />

1<br />

jjjjCID CID CID CID CID CID CID<br />

Wichtig Bei Anlieferung des FUs ist zwischen EA Klemme<br />

01 und 11 eine Brucke installiert Wenn EtA Klemme 01 als<br />

Stopp oder Aktivierungseingang verwendet wird muss diese Brucke entfernt werden<br />

P036 StartquelleJ Stopp EtA Klemme 01 Stapp<br />

Tastenblock GamlB PII37 Auslauf<br />

3Dreht GemaB PII37 GemaB P037<br />

2 Drahl GemaB P037 Auslauf<br />

RS485 Anschruss Gemar3 P037 Auslauf<br />

Hier ist die 2 Draht Steuerung abgebildet Bei der 3 Draht Steuerung ist an EA Klemme 02 ein<br />

einmaliger Befehl fUr einen Start ertorderlich Zur Richtungsanderung an EA Klemme 03 lfO ist ein<br />

Dauerbefehl ertorderlich<br />

Bei Gebrauch eines Optoausgangs mit einer induktiven Last z B ein Relais installieren Sie wie gezeigt eine<br />

Seriendiode parallel um Relais um Schiiden am Ausgang zu vermeiden<br />

4<br />

Wenn die ENBL Brucke entfernt ist fungiert die EA Klemme 01 stets a s Hardware Aktivierung und bewirkt<br />

einen Auslauf Weitere Informationen dazu finden Sie im PowerFlex 40 Benutzerhandbuch auf CD ROM<br />

3


Deutsch S<br />

Steuerungs E1A Klemmenbezeichnungen<br />

Nr Signal Einslellung Beschrelbung Paramo<br />

A1 SchlieGerrelais Fehler SchlieBerkontakt fUr Ausgan9sreleis A055<br />

R2 Relais Bezugspotenzial Ausgangsrelais Bezugspotenzial<br />

R3 Offnerrelais Fehler Offnerkontakt lOr Ausgangsrelais A055<br />

Wahl Analoger Ausgang<br />

DIP Schalter<br />

DIP Schaller<br />

fOr stromziehendlstromliefernd<br />

01 Stopp l<br />

010 V Stellt den Anelogausgang auf Spannung oder Strom ein Diese Einstellung<br />

muss mitA065 Wahl Anlg Ausg Obereinstimmen<br />

Stromliefernd SAC Eingange kOnnen Ober die OIP Schaltereinstellung als stromziehend SNK<br />

oder stromliefernd SRC verdrahtet werden<br />

Auslauf Oie werkseitig Installierte BTOcke oder ein Oftner Eingang muss P036 1<br />

vorhanden sein um den FU zu starten<br />

02 StarWorwartslauf Nicht ektiv Befehl wird vorgabemaBig Ober die integrierte Tastatur P036 P037<br />

03 AichtunglROckwartslauf Nicht aktiv eingegeben Zur Oeaktivierung des AOckwarlslaufs siehe A095 P036 P037<br />

AOckw deak<br />

A095<br />

04 Digitales Bezugspotential FOr digitale Eingange Durch digilale EingAnge von Analog E1A<br />

und Optoausgangen elektronisch getrennt<br />

05 Dig Eingang 1 Voreinst Freq Mit A051lWahl Dig Eing1 programmieren A051<br />

06 Oig Eingang 2 Voreinst Freq Mil A052 Wahl Dig Eing2 pro9rammieren A052<br />

07 Dig Eingang 3 Lokal Mit A053 Wahl Oig Eing3 pr09rammieren A053<br />

08 Dig Eingang 4 Tipp vor Mit A054 Wahl Di9 Eing4 programmieren A054<br />

09 Opto Bezugspotenzial FOr optischgekoppelle Ausgange Durch OptoausgAn9a von<br />

11 24 V DC<br />

Anaiog E1A und digitalen EingAngen elektronisch getrennt<br />

Bezug auf digitales Bezugspotenzial<br />

FU lieferte Strom fOr di9itate Eingange<br />

Maximaler Aus9anggstrom betra9t 100 mA<br />

12 10 V OC Bezug auf enaloges Bezugspotenzial P038<br />

13 tl0 VEin 2<br />

FU lielerte Strom fOr externes 0 1 0 V Potenziometer<br />

MaximalerAusganggstrom betragt 15 mA<br />

Nicht aktiv FOr externe 010 V unipolare oder tlO V bipolare P038<br />

Eingangsversorgung Eingangsimpedanz 100 kOhm oder A051 A054<br />

Potenziometeranschluss A123 AI32<br />

14 Analog Sollw FOr010 V Eing oder 4 20 mA Eing Durch Analogeingange<br />

und ausgangevon digitalen E1A Optoausgangen getrennt<br />

15 4 20 mA Eing l2 Nicht aktiv FOr externe 4 20 mA Eingan9sspannung P038<br />

Eingangsimpedanz 250 Ohm A051A054<br />

A132<br />

16 Analogausgang Ausg freq 010 Der standardmaBige Analogausgang 1st 010V Zum<br />

Konvertieren in einen Stromwert stellen Sie den<br />

Analogausgang OIP Wahlschalter auf020 mA Mit A065<br />

A065 A066<br />

Wahl Anlg Ausg programmieren Oer maximale Analogwert<br />

kann mit A066 Anlg Ausg OG skaliert werden<br />

Maximallast 4 20 mA 525 Ohm 10 5 V<br />

010V 1 kOhm 10 mAl<br />

17 Optoausgang 1 Motor lauft Mit A058 Wahl Optoausg 1 programmieren A058 A059<br />

18 Optischer Ausgang 2 Frequenz erreicht Mil A061 Wahl Optoaus92 programmieren A061 A062<br />

19 AS485 OSI Klemme sollte mlt dam Massepunkt PE verbunden sein wenn<br />

Abschirmung der AS485 OSI Kommunikationsport verwendet wird<br />

1<br />

Siehe FuBnoten I und 4 auf Seite 7<br />

2<br />

010 V Eing und 4 20 mA Eing sind zwei verschiedene Eingangskanale die gleichzeitig angeschlossen<br />

werden kOnnen Diese Eingange kOnnen unabhangig voneinander zur Drehzahlsteuerung oder gemeinsam im<br />

PID Modus benutzt werden<br />

A064<br />

A064


o<br />

o<br />

o<br />

o<br />

Vorbereitun9 auf die FU Inbetriebnahme<br />

Deutsch 9<br />

ACHTUNG Legen Sie zunachst Spannung an den FUan urn die im<br />

Folgenden beschriebenen Vorgange fiir die Inoetriebnahme durchfiihren zu<br />

konnen 1m Gerat liegen allerdings Spannungen in der Hoheder Netzspannung<br />

an Zur Vermeidung eineselektrischen Schlags bzw von Gerateschaden soil ten<br />

die folgenden Schritte nur yon qualifiziertem Wartungspersonal durchgefiihrt<br />

werden Lesen Sie vor der Inbetriebnahme samtliche Anweisungen aufmerksam<br />

durch<br />

Fahren Sie nichtfort falls wiihrend der Durehfiihrung dieser<br />

Anweisung ein beschriebenes Ereignis nicht eintritt Schalten Sie die<br />

Stromversorgung aDS einschlieBlich aller anlagenintemen Sieuerspannungen<br />

Es konnen anlageninteme Spannungen anliegen auch wenn amFU kein<br />

Netzstrom anliegt Beheben Sie die BetriebsstOrung bevor Sie fortfahren<br />

Vor dem Einschalten<br />

1 Stellen Sie sicher dass samtliche Eingange an die korrekten Klemmen<br />

angeschlossen und gesichert sind<br />

2 Stellen Sie sieher dass die anzuschlieBende Netzspannung innerhalb des fiir<br />

den FU zulassigen Bereichs liegt<br />

3 Stellen Sie sicher dass die digitale Steuerspannung 24 V betragt<br />

4 Stell en Sie sicher dass die DlP Schaltereinstellung fiir SNK stromziehend t<br />

SRC stromliefernd dem Steuerverdrahtungsplan entspricht FiirStandort<br />

siehe Seite 7<br />

Wichtig Der voreingestellte Steuerplan lautet stromliefernd SRC Die<br />

Stopp Klemme ist iiberbriiekt EtA Klemme 01 und II urn den<br />

Start tiberdie Tastatur zu ermoglichen Wenn der Steuerplan auf<br />

stromziehend SNK geandert wird muss die Briicke von EtA Klemme<br />

01 und IIentfernt und zwischen EtA Klemme 01 und 04 angebracht<br />

werden<br />

o 5 Stellen Sie sicher dass der Stoppeingang vorhanden ist andernfalls wird der<br />

FU nicht gestartet<br />

Wichtig Wenn EtA Klemme 01 als Stoppeingang verwendet wird muss die<br />

Briicke zwischen EtA Klemme 01 und 11 entfernt werden<br />

Einschalten des FUs<br />

o 6 Schalten Sie die Netzspannung und Eingangssteuerspannungen zum FUein<br />

o 7 Machen Sie sich mitden Funktionender integrierten Tastatur siehenachste<br />

Seite vertraut bevor Sie Parameter der Programm Gruppe einstellen<br />

Start Stopp Richtungs und Drehzahl Steuerung<br />

Der FUkann anhand der werkseitig eingestellten Parameterwerte tiberdie<br />

integrierte Tastatur gesteuert werden Zum Starten Stoppen und zur<br />

Drehzahlregelung direkt iiber die integrierte Tastatur ist keine Programmierung<br />

erforderlich<br />

Wichtig Zur Deaktivierung des Riickwartslimfs siehe A095 Riickw deak<br />

Falls wahrend des Einschaltvorgangs ein Fehlercode angezeigt wird finden Sie<br />

eine entsprechende Erlauterung auf Seite 17 Inforrnationenzur<br />

Vollstandige<br />

Fehlersuche sind dem aufder CD enthaltenen PowerFlex 40 Benutzerhandbuch<br />

zu entnehmen


Deutsch 10<br />

Integrierter Tastenblock<br />

00 00<br />

@w@ 9<br />

0 80 10<br />

c1<br />

CD QJ<br />

10<br />

Menu Beschrelbung<br />

d<br />

p<br />

R<br />

Nr LED LED Zustand Beschreibung<br />

Anzelge Gruppa nur zur Anzalga<br />

Beslehl aus haulig angezeigten FU Betnabszustandan<br />

Grundsatzllcha Programm Gruppe<br />

BeSlehl aus haulig varwandetan progmmmlerbaran<br />

Funktionen<br />

Erwelterte Progremm Gruppe<br />

Bastaht aus den mslllcMn programmierbaren<br />

Funktionen<br />

F Starung<br />

Besteht aus ainer Auflistung YOn Codes fUr beslimmte<br />

FehlerzustAnde Wird our dann angezeigt wenn ein<br />

Fehlar vorliegt<br />

0 Setriebs f Stetig rot FU liiutt und Motordrehung erlolgt in SOllrichtung<br />

Richtungsstatus Blinkt rot Der FU hat einen Richtungswechsel Befehl erhalten Zeigt die<br />

tatsiichliche Motordrehrichtung wiihrend der Verz6gerung auf Null an<br />

t Alphanumerische Stetig rot Zeigt Parameternummer Parameterwert oder Fehlercode an<br />

Anzeige Blinkt rot Wenn eine Zifter blinkt kann diese bearbeitet werden<br />

Wenn aile Ziftern blinken liegt eine St6rung vor<br />

8 Anzeigeeinheiten Stetig rot Zeigt die Einheiten des angezeigten Parameterwerts an<br />

0 Programmstatus Stetig rot Zeigt an dass Parameterwerte geandert werden k6nnen<br />

0 Fehlerstatus Slinkt rot Es liegt ein FU Fehler vor<br />

0 Poti Status Stetig grun Potenziometer der integrierten Tastatur ist aktiviert<br />

8 Start Tastenstatus Stetig grun Start Taste der integrierten Tastatur ist aktiviert<br />

Richtungswechsel Taste ist ebenfalls aktivert sofern sie nicht mit<br />

A095 Ruckw deak deaktiviert wurde<br />

Nr Taste Bezelchnung Beschreibung<br />

0 Escape 1m ProgrammiermenO einen Schrill zurOck gehen<br />

Die Anderung eines Parameterwerts abbrechen und den<br />

Programm Modus verlassen<br />

0<br />

@ Select Taste im ProgrammiermenO einen Schrill weiter gehen<br />

Bei der Anzeige eines Parameterwerts eine Zifter auswahlen<br />

CDGD Pfeil nach oben Sildlauf durch Gruppen und ParameterdurchfOhren<br />

Pfeil nach unten Den Wert einer blinkenden Zifter erh5hen verringern<br />

8 Eingabe<br />

1m PrQgrammiermenO einen Schritt weitergehen<br />

Eine Anderung eines Parameterwerts speichern<br />

Potentiometer Dient zur Steuerung der FU Drehzahl 1st vorgabemiiBig aktiviert<br />

Wird Ober Parameter P038 gesteuert<br />

CD Start Dient zum Starten des FUs 1st vorgabemaBig aktiviert<br />

Wird Ober Parameter P036 gesteuert<br />

QJ<br />

ROckwiirts Dient zur Anderung der FU Richtung 1st vorgabemaBig aktiviert<br />

Wird abet Parameter P036 und A095 gesteuert<br />

Stopp Dient zum Stoppen des FUs oder zum L6schen eines Fehlers<br />

Diese Taste ist immer aktiviert<br />

Wi d uber Parameter P037 gesteuert


Deutsch 11<br />

Anzeigen und Bearbeiten yon Parametern<br />

Beim Abschalten wird der zuletzt vom Benutzer gewiihlte Anzeige Gruppe Parameter gespeichert<br />

Dieser wird standardmiiBig beim niichsten Einschalten angezeigt<br />

Es folgt ein Beispiel grundlegender Funktionerider integrierten Tastatur und der Anzeige Dieses<br />

Beispiel enthiilt grundlegende Navigationsanweisungen und veranschaulicht wie der erste Parameter<br />

der Programm Gruppe programmiert wird<br />

Schritt Taste n Beispielanzeigen<br />

1 Beim Einschalten wird der vom Benutzer zuletzt<br />

gewiihlte n<br />

Parameter der Anzeige Gruppe mit<br />

blinkenden Zeichen kurz angezeigt Danach wird u u<br />

wieder der aktuelle Wert des Parameters PROGRAM FAULT<br />

angezeigt 1m Beispiel wird der Wert von dOOl<br />

Ausgangsfreql<br />

0 0<br />

bel gestopptem FU angezeigt<br />

I<br />

VOLTS<br />

nlo<br />

2 Drucken Sie Esc einmal um die beim Einschalten<br />

Id n n VOLTS<br />

eingeblendete Parameternummer der<br />

Anzeige Gruppe anzuzeigen Nun blinkt die U U<br />

Parameternummer PROGRAM FAULT<br />

0 0<br />

3 Drucken Sie Esc erneut um das Gruppenmenu<br />

aufzurufen Der Gruppenmenu Buchstabe blinkt<br />

4 Driicken Sie den Pfeil nach oben bzw den Pfeil<br />

nach unten um einen Bildlauf durch das<br />

Gruppenmenu d P und A durchzufUhren<br />

5 Drucken Sie zum Eingeben einer Gruppe die<br />

Elngabe oder die Sel Taste Nun blinkt die rechte<br />

Zifter des zuletzl angezeigten Parameters dieser<br />

@ Ildnn<br />

J oder 0D<br />

OUU I<br />

PROGRAM FAULT<br />

o 0<br />

rlo<br />

Bader @ P 0 3 H<br />

Gruppe PROGRAM FAULT<br />

6 Drucken Sie den Pfeil nach oben bzW den Pfeil<br />

J oder nach unten um einen Sildlauf durch die in der<br />

Gruppe enthaltenen Parameter durchzufUhren @J<br />

0 0<br />

BOder@ I<br />

2 3 nlo<br />

7 Drucken Sie die Eingabe oder die Sel Taste um<br />

VOLTS<br />

den Wert eines Parameters anzuzeigen Wenn der<br />

Wert nicht bearbeiten werden soli kehren Sie<br />

U b<br />

durch Drucken der Esc Taste zur PROGRAM FAULT<br />

Parameternummer zuruck 0 0<br />

8 oder @ 2 3<br />

8 Driicken Sie die Eingabe oder Sel Taste um<br />

zur Searbeitung des Parameterwerts den<br />

Programm Modus aufzurufen Die rechte Zifter<br />

blinkt und die Programm LED leuchtet wenn der PROGRAM FAULT<br />

Parameter bearbeitet werden kann 0<br />

9 Driicken Sie zum Andern des Parameterwerts den<br />

Pfeii nach oben bzw den Pfeil nach unten Bei<br />

Bedart kennen Sie mit der Sel Taste von Zifter zu<br />

Zifter bzw Bit zu Sit wechseln Die Zifter bzw das<br />

Bit das geiindert werden kann blinkt<br />

10 Drucken Sie die Esc Taste um eine Anderung<br />

abzubrechen Die Zifter hert nun auf zu blinken der<br />

vorllergehende Wert wird wieder hergestellt und<br />

die Programm LED erlischt<br />

oder<br />

Drucken Sie zum Speichern einer Anderung die<br />

Eingabetaste Die Zifter hert nun auf zu blinken<br />

und die Programm LED erlischt<br />

11 Driicken Sie die Esc Taste um zur Parameterliste<br />

zuruckzukehren Drucken Sie die Esc Taste bis<br />

das Programmiermenu ausgeblendet wird<br />

Wenn sich die Anzeige bei Betiitigung der Esc Taste<br />

@oder jJ<br />

VOLTS<br />

8 I 2 2 UnlOVOLTS b<br />

PROGRAM FAULT<br />

0 0<br />

PO j<br />

I<br />

PROGRAM FAULT<br />

nicht veriindert wird dOOI Ausgangsfreql 0 0<br />

an eZelgt Drucken Sie die Eingabe oder<br />

Se Taste um das Gruppenmenu aufzurufen<br />

I b<br />

VOLTS<br />

10


Deutsch 12 Weltare Informationan zu dan Paramatem finden Sia im PowerFlex 40 Banutzer11andbuch auf CO AOM<br />

Parameter der Anzeige Gruppe<br />

Nr Parameter MlnJMax AnzelgeJOptlonen<br />

dOOl Ausgangsfreql O O Meximalfrequenz 0 1 Hz<br />

d002 Freauenzsollwert O O Maximalfrequanz 0 1 Hz<br />

d003 Ausga troml O OO FU Strom A x 2 0Q1 A<br />

d004 Ausgan annung O FU Nennspannung 1 VAC<br />

dOOS DC pannungj Basiarend auf 1 VDC<br />

FU Nennspannung<br />

d006 Gertitestatusj 01 1 ZuSlandwahr Bil 3 au BiU Bil Q<br />

Vaflogerung Beschlaunigung VorwMs Betnab<br />

d007 Code Storung xl F2IF122 Fl<br />

d009<br />

dOlO Prozessanzelgel 0 00 9999 0 01 1<br />

d012 Sleuerquella 09 Bit 1 Drehzahlsollwert Bit 0 Slartbefehl<br />

siahe P0311 9 Tippfreqi slehe P036 9 Tippbelnebi<br />

d013 Steuereing Stat Oil I Eingang ekluell Bil 3 au BiU Bil Q<br />

DB Trens ein Stopp Eing AichVRW Ein SlrtNW Eing<br />

d014 Dig Eing Status 0 1 1 Eingang aktuell Bil 3 au BiU BjtQ<br />

Dig Eing 4 Dig Eing 3 Dig Eing 2 Dig Elng 1<br />

d01S Komm Statusj 0 1 1 Zustand wahr Bil 3 au BiU Bil Q<br />

Fehlar DSI Tx Ax<br />

dOl6 Aaglar SW Vars 1 1 00 99 99 0 01<br />

d017 Geratetypj 1001 9999 1<br />

d016 IBetnebszaltj 09999 Std 1 10 Sid<br />

d019 lTeslpunkt Oaten O FFFF I hexadezimel<br />

d020 Anlg Elng 0 10 VI 0 0 100 0 0 1<br />

d021 Anlg Eing 4 20mAI 0 0 100 0 0 1<br />

d022 Ausgangsleistungl O OO FU Laislungx 2 0 01 kW<br />

d023 Ausg Lelstungsf 0 0 160 0 Grad 0 1 Grad<br />

d024 Geratetemp 0 120 C I C<br />

d025 ZAhlerslatus 0 9999 1<br />

d026 lTimerstatusj 0 0 9999 0 1 s<br />

d028 Stp Loglkslatus OfT 1<br />

d029 Wirkstroml O OO FU Strom A x 2 0 01 A<br />

Schnell Inbetriebnahme mit den wichtigsten Parametern<br />

der Programm Gruppe<br />

Der PowerFlex 40 istfjr eine schnelle und problemlose Inbetriebnahme konstruiert Die<br />

Programm Gruppe enthiilt die am meisten verwendeten Parameter<br />

QJ Bevordiesar Parameter geandert wird muss der FU gestoppt werden<br />

Nr Parameter IMlnJMax Anzelge Optlonen Elnslellung<br />

P031 Motornennspg 120lFU Nennspannung 1 V AC Basierend auf<br />

QJ Eingestelltauf die Nennspannung des MOlors Typenschild<br />

FU Nennspannung<br />

P032 Motnennfreq 115 400 Hz 1 Hz 60Hz<br />

QJ Eingestelll auf die Nennfraquenz des Motors Typenschild<br />

P033 UbertaSls1rom 10 0 FU Nannstrom A x2 0 1 A Basierend auf<br />

Auf den maximal zulassigen Motorstromwert einslellen<br />

FU Nennspannung<br />

P034 Minimalfrequenz 10 0 400 0 Hz 0 1 Hz O OHz<br />

Legl die nledrigste kontinuierliche Ausgangsfrequenz des FUs fest<br />

P035 Maximalfrequenz 10 400 Hz 1 Hz 60 Hz<br />

QJ Leg1 die hOchste Ausgangsfrequenz des FUs fest<br />

P036 Slartquellel 10 6 0 Tastenbl0ci<br />

11j<br />

QJ Stellt den zum Startendes FUs verwendelen Steuerplan<br />

I 3 Drahr<br />

ein<br />

1<br />

2 2 Draht<br />

1m aktMerten Zustand ist die AichlUngswechsel Taste ebenfalls 3 2 W PegSens<br />

4 2W Ho DrehI<br />

aktiviert sofarn sie nlchtmit A095 AOckw deak deaktivlert<br />

5 COM Port<br />

wurde<br />

6 MomVWIRWStrg<br />

0


Waitare Informationen zu dan Paramelernlinden Sie im PowerFlax 40 Benutzerhandbuchauf CD ROM Deutsch 13<br />

Q Bevordiaser Parameter gelindert wird muss der FU gasloppt werdan<br />

Nr Parameter MinJMax AnzeigelOptionen Einslellung<br />

P037 ISloppmodusj 1019 o Rampe CF ll 1 Auslau CF<br />

0<br />

II<br />

Aktivar Stoppmodus lur aUa Stoppquallen z B Tastalur<br />

VOIwlirtslaul EtA Klemme 02 Rucl wlirtslauf EtA Klemma 03<br />

2<br />

3<br />

DC Bremse<br />

DCBrAulo CF crill<br />

1<br />

RS485 AhSchluss wobel dia unlen au gafUhrtan Ausnahman<br />

zutreffen<br />

WiChll An EIA Klemme01 erlolgl nur dann kein Auslauf wenn<br />

P0361 lartquallaj<br />

4<br />

5<br />

8<br />

Rampe<br />

Auslaur<br />

DC Bremse<br />

auf 3 Drahl Stauarung eingestellt ist Bei dar 7 DC Br Auto<br />

3 Draht Steuerung wird EtA Klemma 01 uber P037 Stoppmodusj 8 Rmp EMBSg FO<br />

gesteuart 9 Rmp EMB Slrg<br />

1 1<br />

StoPll ingang IOscht auch aktive Fahler<br />

P038 SoUdrehzahl 10 7 o FU por 0<br />

1<br />

Stellt dia Drehzahlsol ertQualle des FUs ein<br />

2<br />

Inl Frequ<br />

o 10V Wlchtlg<br />

Elng<br />

Wenn A051 odar A052 Wahl Dig Ein x aui Oplion 2 4 3 4 20mA 5 6 13 odar 14<br />

Eing<br />

ein estellt ISI undder digitala ingang aktiviert ist<br />

ubersteuern A051 052 A053 bzw A054den durch diesen<br />

q<br />

Paramatar festgelegtan Drehzahlsollwert Elnzelheiten sind Kapilel 6 Stp Logik<br />

1 des auf der CD enthaltenen powerFlex 40 BenutzertJandbuchs<br />

7 AlgEingMulti<br />

tu entnehmen<br />

P039 IBeschl Zeit 1 10 01600 0 s 0 1 S 10 0s<br />

Definiert die Zen die dar FU fUr die Bescl1leunigung aui slimtlicl1e<br />

Fraquenzen banOtigt<br />

P040 VerzOg Zeil 1 10 11600 0 s 0 1 s 10 Os<br />

Daliniert die Zeit dia der FU fUr Verzogarungen benOtigt<br />

P041 IReset Werkseinst 10 1 0 Be aitllnakt QJ<br />

0<br />

Setzt die Werte allar Paramaler aui die Werkseinstallung zurOck<br />

1 Rucks Std<br />

P042 ISpannungs asse 1213<br />

QJ Legl<br />

2<br />

480 V<br />

Niedersp<br />

3<br />

die Spannungsklasse der FUs mit600 V fest<br />

3 Hochsp 600 V<br />

Erweiterte Parametergruppe<br />

Nr Parameter MinJMax Anzeige Optionen Einstellung<br />

A051 Wahl Dig Eingl<br />

EJA Kfemme 05<br />

0126 0<br />

1<br />

Nicht verw<br />

BeschNerz2 13<br />

14<br />

10V EingSlrg<br />

20mA EingSt<br />

4<br />

A052 Wahl Dig Eing2<br />

EJA Kfemme 06<br />

2<br />

3<br />

1ippen<br />

Ex Fehla<br />

15<br />

16<br />

PID deaktiv<br />

Pol erh<br />

4<br />

A053 Wahl Dig Elng3 4 Eingest Fraq 17 PoI reduz 5<br />

EJA Klemme 07 5 Lokal 18 Timerstart<br />

A054 Wahl Dig Eing4j<br />

QJ<br />

6 COM Port 19 zahlerEing 11<br />

EJA Klemme 08 7 t<br />

Fehlerquitt<br />

r<br />

20<br />

21<br />

22<br />

RucksTime<br />

ROckszahle<br />

ROcks1im Zlih<br />

1 0 DClnj op CF 23 Logikeing 1<br />

11 1ippvorw 24 Logikeing 2<br />

12 Tlpp rOckw 25 Stromgrenza2<br />

26 Anlg Invert<br />

A055 Wahl Relaisausg 0 22 o BerIFehlel<br />

1 wFreq<br />

11 Logikeing 1 0<br />

erreich 12 Logikeing 2<br />

2 Motor lauft 13 Logik 1 2<br />

3 Ruckwarts 14 Logik 1 oder 2<br />

4 MotorObert 15 StpLogikAusg<br />

5 ampe Reg 16 Timer Ausg<br />

6 Vber F equ 17 Jiihler Ausg<br />

7 Ubar Strom 18 Uba PF Ang<br />

8 Uber DC Volt 19 VerIAnEing<br />

9 wNeuversuche 20 ParamSlrg<br />

10 Uber Anlg V 21 N wiederh Fhl<br />

22 EM Brmsstrg<br />

A056 Ebene Relaisausg 0 0 9999 0 1 0 0<br />

A058 WahlOptoausg 1 0122 o BerlFehle 11 Logikeing 1 A061 Wahl Optoausg2<br />

1 Freq<br />

2<br />

erreich 12 Logikeing 2 2 Motor lauft 13 Logik<br />

1<br />

1 2<br />

3 ROckwarls 14 Logik 1 oder 2<br />

4 MotorObert 15 StpLogikAusg<br />

5 ampe Reg 16 Timer Ausg<br />

6 Vber Frequ 17 Jiihler Ausg<br />

7 Vber Strom 18 Uber PF Ang<br />

8 Ubar DC Voir 19 VarIAnElng<br />

9 N uversuche 20 ParamStrg<br />

1 0 Uber Anlg V 21 N wiederh Fhl<br />

22 EM Srmsstrg<br />

6


Deutsch 14 Weltere Informationen zu den Palametern flndan Sie 1m PowarFlex 40 Benutzarhandbuch auf CD ROM<br />

Nr Parameter I Mln Max<br />

EbeneOptoausgll 10<br />

A059<br />

A062 IEbanaOptoausg2<br />

0 9999<br />

Einsrellung A055 A05B und A061 A056 AD59 und A062 MinJMax<br />

6 0 400 Hz<br />

7 Ol1ao<br />

8 01815 V<br />

10 0 100<br />

16<br />

0 19999s<br />

17 119999 Zihler<br />

la 1 laOGred<br />

20<br />

0 1<br />

10<br />

Anzelge Optionen Elnstellung<br />

A064 Optoausg Loglk 10 3 I 0<br />

A064 Option Optoausg ILogik Optoausg 2Logik<br />

0 NO SchlieBer NO SchlieBer<br />

1 NC ffner NO SchlieBer<br />

2 NO SchlieBer NC Oflner<br />

3 NC Offner NC Offner<br />

A065 Wahl Antg Ausg 10 20 11 0<br />

m<br />

Option Ausgangsbereich Mlnlmaler Ausgangswerl<br />

Position des<br />

DtP Schalle<br />

o AusFreq 0 10 010V OV O Hz P035 Maxlmaltrequenz 010 V<br />

gAO aings rt<br />

I OulSlrmo l0 010V OV OA 2000 FU Nennstrom o IOV<br />

2AusVolto I0 010 V OV OVolI 120 FU Nennausgangsspannung 010 V<br />

3 Auslstg 0 10 010V OV OkW<br />

4 TstDetO IO 010 V<br />

200 FU Nenntelstung 010 V<br />

OV OOOO 65535 Hox FFFF o IOV<br />

5 AusFreq 0 20 020 mA OmA OHz P035 Maximalfrequenzj 020 mA<br />

6 OulStrom 0 20 0 20 mA OinA OA 200 FU Nennstrom 020 mA<br />

7 AusVolI 020 020 mA OmA OVolt 120 FU Nennausgangsspannung 020 mA<br />

a Auslstg 0 20 020mA OmA OkW 200 FU Nennleislung 0 20 mA<br />

9 TstDetO 20 020 mA o mA 0000 65535 Hex FFFF 0 20 mA<br />

10 AusFreq 4 20 4 20mA 4mA OHz P035 Maximalfrequenzj 020 mA<br />

11 OulStrom 4 20 4 20 mA 4inA OA 200 FU Nennslrom 020 mA<br />

12 AusVoI14 20 4 20 mA 4mA OVolI 120 FU 020 mA<br />

Nennausgangsspannung<br />

13Auslstg 4 20 4 20inA 4mA OkW 200 FUNenntelstung 020inA<br />

14 TslDat4 20 4 20 mA 4 mA 0000 65535 Hex FFFF 0 20 mA<br />

15 AusDrhm 0 IO 010V OV OA 200 FU Nennslrom oIOV 16 AusDrhm 0 20 020 mA OmA OA 200 FU Nennstrom 020 mA<br />

17 AusDrhm 4 20 4 20inA 4inA OA 200 FUNennslrom 020inA<br />

la Sollw 0 10 0 10V OV O 100 0 SOllwert Einstellung oIOV<br />

19 Sollw 020 020inA OmA O 100 0 SoItwert EinstelJung Q20inA<br />

20 Sollw 4 20 420 mA 4mA 0 100 0 Sollwert Elnsteltung 020 mA<br />

A066 IAnlg Ausg OG 0 800 1<br />

A067 Bescht Zelt 21 0 0 600 0 s 0 1 s 20 0s<br />

A068 VerzOg Zait2 0 1 600 0 s 0 1 s 20 0s<br />

A069 Interne Frequenzl 0 0 4000 Hz 0 1 Hz 60 0 Hz<br />

1<br />

A070 orelnst Freq 0 0 0 4000 Hz 0 1 Hz 0 0 Hz<br />

A071 orelnst Freq I<br />

A072 VoreinstFreq<br />

5 0 Hz<br />

2<br />

10 0 Hz<br />

A073 oreinsl Freq 3<br />

A074 Vorelnst Freq<br />

20 0 Hz<br />

4<br />

30 0 Hz<br />

A075 oreinst Freq 5<br />

A076 Vorelnst Freq 6<br />

40 0 Hz<br />

50 0 Hz<br />

A077 oreinst Freq 7<br />

I<br />

60 0 Hz<br />

Zur Aktivlerung von Voreinst Freq OJ muss P038 Solldrehzahi euf Option 4 eingestellt werden<br />

Elngangsstalus<br />

eA 5<br />

van Ein8angsslalus Ilal Ein8angsstalus<br />

EinK<br />

BeSChIN eler wild<br />

lJ 2 yon ilaJ Elng 3 ElA emme 6 ElA<br />

lemme07<br />

Frequenzquelle<br />

0 0 0 Voreinsl FreqO<br />

I 1<br />

1<br />

0 0 VoreinslFreq Bescl1I Zen Zeill<br />

0 0 VoreinslFreq2 Beschl Zeil Zeil2<br />

I I 0 VoreinslFreq3j Beschl Zeil Zeil2j<br />

0 0 I VorelnslFreq4 Besch I Zeit Zeit 1<br />

I<br />

I I<br />

1 0 VorelnstFreq5 Bescht Zelt IJl VerzOg Zelt 11<br />

0 1 1 Vorelnsl Freq6 Bescht leit 2J1 VerzOg 2eil2<br />

1 Voreinsl Freq7 eescht Zelt 2J1 VerzOg Zelt 2<br />

2 Wenn ein digllaler Elngang aufJ3eschl 2 und VerzOg 2 elngestelll und der Eingang aklivlert1st Obersleuerl dieser Eingang<br />

die Einstellungen dieser Tabelle<br />

A07e Tippfrequenz 10 0 Maximalfrequanz 10 1 Hz 10 0 Hz<br />

0 0<br />

100


Weilere Inlormalionan zu den Parametamfinden 5ie im PowerFlax 40 Benutzerhandbuchauf CD ROM Deutsch 1S<br />

Nr<br />

A079<br />

AOBO<br />

A081<br />

A082<br />

QJ<br />

A083<br />

A084<br />

Parameter MinJMax<br />

IBeselllNerzog 10 1 600 0 s<br />

Dauer DC Bramse 10 0 99 9s<br />

Einslallung 99 9 s Deuarbalrieb<br />

Ebene DC Bremse 0 0 FU 5trom A x 1 8<br />

Wahl DB Widarst 0199<br />

S Kurve 0100<br />

WahlVerstark 014<br />

Nuraktiv wenn A125 Momenlpert mod aulO VlHz<br />

aingaslelltist<br />

A085 Slartverslark 10 0 25 0 0 1<br />

AnzeigeJOptionen<br />

0 1 s<br />

0 1 s<br />

0 1 A<br />

o AUS<br />

1 Normaler RA Wid<br />

1<br />

Einslellungan in<br />

0<br />

VlHz Wert<br />

1 30 0 IT<br />

2 35 0 IT<br />

3 40 0 IT<br />

4 45 0 IT<br />

der EeI spannung<br />

5 0 0 kein IR<br />

6 0 0<br />

72 5 CT<br />

8 5 0 CT<br />

9 7 5 CT<br />

Nur aktiv wenn A084 WahlVerslark und A125 Momentpan mod j auf 0 eingaslallt sind<br />

A086 Knickspannung 10 0100 0 10 1<br />

Nur aktiv wann AOB4 Wahl Verslark und A125 Momentpert mod aul 0 eingeslelll sind<br />

A087 Knickfrequenz 10 0 4000 Hz 10 1 Hz<br />

Nur aktiv wenn A084 Wahl Verstark undAI25IMomenlpert mod auf 0 eingestelll sind<br />

AOB8 IMaximalspannung 20INannspannung V 1 V AC<br />

A089 Slrombegrenzl O I FU SlromAxl B 0 1 A<br />

2 KeinSchutz<br />

3 99 der Einschalldauar<br />

A090 ObenaSI Modus 0 2 0 Keine Reduz 1 Min Raduz<br />

2 Max Reduz<br />

A091<br />

A092<br />

A093<br />

A094<br />

QJ<br />

A095<br />

QJ<br />

A096<br />

A097<br />

A09B<br />

A099<br />

Al00<br />

Q<br />

Al0l<br />

Al02<br />

Al03<br />

Al04<br />

Al05<br />

Al06<br />

Al07<br />

Al08<br />

Taktfrequanzj<br />

IFhl Naustartvers<br />

Ilnl Neustartversj<br />

Autoslart<br />

ROckw deak<br />

IAiag Slart EINj<br />

Kompensation<br />

SW Stromauslos<br />

Prozess Faktor<br />

5torungsquitt<br />

2 0 16 0 kHz<br />

0 9<br />

0 0 300 0 s<br />

01<br />

01<br />

011<br />

013<br />

O O FU Slrom A x 2<br />

0 1 999 9<br />

0 2<br />

Progr blockier 0 9999<br />

Teslpunkt Wahl 400IFFFF<br />

Komm Dalenrale 0 5<br />

oer FU myss aus und wiedereingeschaltet werden<br />

bevor die Anderungen wirksam werden<br />

Komm Knolenadr j 11247 oer FU muss aus und wiedereingeschaltet werden<br />

bevor die Anderungenwirksam werden<br />

MaBnKommVerlustj 0 3<br />

Komm Verlustzeil 0 1 60 0 s<br />

Komm Formal 0 2<br />

Oer FU mllss aus und wieder eingeschaltet werden<br />

bevor die Anderungen wirksamwerden<br />

15prache<br />

A 109 AnIAusg 5ollw<br />

Al10 AnlgEin 0 10V UG<br />

Ol<br />

1 10<br />

0 0 100 0<br />

0 0 100 0<br />

0 1 kHz<br />

1<br />

0 1 s<br />

o AUS 1 Freigabe<br />

o ROel EIN 1 ROck AU5<br />

o AUS 1 Freigabe<br />

10 10 0 CT<br />

11 12 5 CT<br />

12 15 0 CT<br />

13 17 5 CT<br />

14 20 0 CT<br />

o AUS 2 Mechanischn<br />

1 Elektrisch 3 Beide<br />

0 1 A<br />

0 1<br />

o Bereitllnakt 1 FehlerrOeI s<br />

2 Puffer losch<br />

o Freigegeben 1 Blockiert<br />

1 hexadezimal<br />

0 1200 3 9600<br />

1 2400 4 19 2 K<br />

2 4800 5 <strong>3a</strong> 4 K<br />

1<br />

o Fehle 2 Slopp<br />

1 Auslaufslopp 3 Letzte Forts<br />

0 1<br />

0 RTU B N l 3 RTU B N 2<br />

1 RTU 8 E l 4 RTU B E 2<br />

2 RTU 8 Dl 5 RTU 8 D 2<br />

1 English 6 reserviert<br />

2 Franyais 7 Portugues<br />

C r<br />

8<br />

9<br />

reserviert<br />

reservierr<br />

5 Deutsell 10 Nederlands<br />

0 1<br />

0 1<br />

Einstellung<br />

100s<br />

O Os<br />

A x 0 05<br />

o<br />

o AUS<br />

8<br />

7 4 11 kW<br />

2 5<br />

25 0<br />

15 0 Hz<br />

Nennspannung V<br />

Ax 1 5<br />

o<br />

4 0 kHz<br />

o<br />

1 0s<br />

o<br />

0 0 Aus<br />

o<br />

o<br />

30<br />

400<br />

3<br />

100<br />

5 0<br />

o<br />

0 0<br />

0 0


Deutsch 16<br />

WeltaraInformetionen zu denParametarn flndan Sieim PowerAax 40 Banutzerhandbuch aufCO AOM<br />

Nr Parameter MlnJMax Anzelge Optlonen elnstellung<br />

All1 IAnlgEln 0 f OV OG 0 0 100 0 0 1 100 0<br />

QJ<br />

A112 AnlEin 4 20mA UG 0 01100 0 0 1 0 0<br />

QJ<br />

A113 AnlEin 4 20mA OG 0 0100 0 0 1 100<br />

QJ<br />

Al14 SchlupfHz Voll A 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

Al15 Prozasszall Min 0 00 99 99 0 01 0 00<br />

Al16 Prozessze Max 0 00 99 99 0 01 0 00<br />

A117 Busreg Modus 01 0 AUS 1 Freigabe 1<br />

A118 Slrombegrenz 2 0 l FU Slrom Ax 1 8 0 1 A Ax 1 5<br />

A119 Sprungfraquenz 0 400 Hz 1 Hz OHz<br />

Al20 ISprungfreq Band 0 0 30 0 Hz 0 1 Hz 0 0 Hz<br />

A121 Verz Slorungl 0 5 o 60 Sekunden 3 360 Sakunden 0<br />

1 120 Sekunden 4 480 Sekunden<br />

2 240 Sekunden 5 Fehlar AUS<br />

A122 Verl Anlg Eing 0 6 0 AUS 4 Min Freq Aef 0<br />

1 Fehler F29 5 Max Fra Aer<br />

ff er<br />

6 Inl Freq ar<br />

Af23 10 V Bipolar ald 01 o Einpol Eing I zweipol Eing 0<br />

A124 Var PDM daald 01 o Freig be I AUS 0<br />

A125 Momantperl mod 0 1 0 VlHz 1 Sans Vacto 1<br />

A126 Molornannslrom O l FU SlrOm A x 2 0 1 A Nennstrom A<br />

A127 Auloluning 02 o BeraiVlnakf 2 Tuning Oreh 0<br />

1 Tuning Still<br />

A128 IA Spgsabfall 0 0 230 0 V AC 0 1 V AC Nannspannung V<br />

A129 Magn stromvorg O OO Molornennspg 0 01 A Nannstrom A<br />

A130 PID Trimm OG 0 0 400 0 0 1 60 0<br />

A131 PID Trlmm UG 0 0 400 0 0 1 0 0<br />

A132 Wahl PID Sollw 0 8 0 PID AUS 5 SollwTrlmm 0<br />

1 PID Sollwert 6 0 10V Trlmm<br />

2 O IOV Eing 7 4 20mA Trim<br />

3 A 20mA Elng 8 Komm Trlm<br />

4 COM Pon<br />

Al33 PID lstw Auswahl 0 2 0 0 10VEing 2 COM Port 0<br />

f HOmA Eing<br />

A134 PID Prop Vers 0 00 99 99 0 01 0 01<br />

A135 PID lnleg Zeil 0 0 999 9 s 0 1 2 0<br />

A136 PID Diff Aale 0 00 99 99 l s 0 01 0 00<br />

A137 PID Sollwert 0 0 100 0 0 1 0 0<br />

A138 PID Tolband 0 0 10 0 0 1 00<br />

A139 PID Vorein 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A140 Sip logik 0 7 000l bAFF 4Ziffern ooF1<br />

A147<br />

Eine Uste der Zilfernoplionen ist dem aufder CD enthaltenen<br />

PowerFlex40 Benutzerhandbuchzu entnehmen<br />

A150 SIp Logikzelt 0 7J 0 0 9999 0 1 3O Os<br />

A157<br />

A160 EM Brm Aus Verz 0 01110 00 0 01 2 00<br />

A161 EM Brm Ein Verz 0 01110 00 0 01 2 00<br />

A162 WhIMOP Re elmod 0 1 o Null MOP SW 1 MOP Wrt sp 1


Fehlercodes<br />

Deutsch 17<br />

Urn einen Fehler zu loscheiJ die Stopp Taste drticken die Strornversorgung aus<br />

und wiedereinschalten oder A100 Storungsquitt auf I oder 2 einstellen<br />

Nr Fehler Beschreibung<br />

F2 Hillseingangl l Detentrale Verdrahtung aberprOlen<br />

F3 Netzstorung Eina UberprOlung aul niedrige Netzspannung odar Spannungsunterbrechungan durchfUhren<br />

F4 Unlerspannungl l<br />

Eine OberprOlung auf niadriga Netzspannung oder Spannungsunterbrechungen durchfUhren<br />

F5 Oberspannungl Die Netzleitung aul hohe Leiters annung oder Obergangszusffinde prOfen OberMhte Busspannung kann auch<br />

auf generatorischen Motorbetrie zurOckzufOhren sain Verzogerungszeil verlangem oder optionale dynamische<br />

Bremseinstallieren<br />

F6 Motor blocldart 1 Beschl Zeit xlerMhen bzw dia last verrin ern damit derFU t<br />

Ausgangsstrom den mif ParamaterA089<br />

Strombegrenzl eingastalltan Stromwert nlc aberschraitat<br />

F7 Motor aberlasfetl Dja Motonast ist zu hoch Sie muss reduziert werdan sodass der FU Ausgangsstrom den mit Parameter P033<br />

Uberlaststrom eingastellten Stromwert nicht abarschreitat<br />

F8 Kahlk Obertemp Den Kahlkorper aul blockierte odar verschmutzte Kahlrippen untarsuchen PrOlen ob die Umgabungstamperetur<br />

aber 40 C far IP 3Qlnstallationan NEMA Typ 1 bzw aber 50 C fUr offene Installafionen angestiegen ist<br />

Laffer prOfen<br />

FI2 HW Oberstrom Programmierung pralen Auf abermaBige Belastung f lsche DC Boosteinstellung zu hoch eingestellte<br />

Spannung fUr DC Bremse oder andere Ursachen fUr Uberstrom prOlen<br />

FI3 Erdschluss Den Motor und die extarne Verdrahtung zudan Ausgangsklemmen das FUs auf Erdung abarprOlen<br />

F29 Van Anlg Eing Ein Analogeingang ist so konfiguriert dass bei eiliem Signalver1ust ein Fehler ausgegeben wird Es ist ein<br />

Signalvenust aufgetreten<br />

F33 Fhl Neustartvers Fehlerursache beheben undmanuell quittieren<br />

F38 Erdschluss Ph U Verdrahtung zwischen FU und Motor aberprUfan Motor auf Erdschluss in einerPhase prafen<br />

FU auswechseln wenn Fahler nicht behoben werden kann<br />

F39 Erdschluss Ph V<br />

F40<br />

Erdschluss Ph W<br />

F41 Kurzschluss UV Motor undVerdrahtung der FU Ausgangsklemmen aUf Kurzschluss pralen<br />

FU auswechseln wenn Fehler nich1 behoben werden kano<br />

F42 Kurzschluss UW<br />

F43 Kurzschluss VW<br />

F48 ParamWerkseinst Der FU hat den Befehl emalten Standardwerte in denEEPROM zu schreiben Fehler quiltieren oder FU aus und<br />

wiedereinschalten FU Parameter nach Bedan programmieren<br />

F63 SW Oberstrom lastanforderungen und Einsfellung des Parameters A098 SW Stromauslosl abarprOlen<br />

F64 FU Obenast last verring rn oder Beschl Zeitverlangern<br />

F70 Leistungseinheit Stromzufuhr aus und wiedereinschalten FU auswechseln wenn Fehler nicht behobenwerden kann<br />

F71 Adpt Ntzw Ven 1m Kommunikationsnetz ist ein Fehler aufgetre ten<br />

FBO Autotune Fehler Die Autotuning Funktion wurde durch den Benutzer abgebrochen oder ist ausgefallen<br />

FBI Komm Venust Falls der Adapter nicht absichtlich getrennt wurde die Verdrahtung zum Anschluss prOfen Nach Bedan<br />

o<br />

n Verbindung aberprOfen Ein<br />

X p7e 1<br />

1 i i e f r<br />

FIOO Param PrOfsumme Werkseinstellungen wiederhersleHen<br />

nu t uuS I<br />

FI22 ElA Kartenlehler Stromzufuhr aus und wiedereinschalten FU auswechseln wenn Fehler nic t behoben werden kann<br />

I<br />

Auto Reset<br />

Betriebsfehler Mit den Parametern A092 und A093 konfigurieren


Deutsch 18<br />

FU Abmessungen<br />

PowerFlex 40 BaugroBe Nennwerte sind in kW angegeben<br />

BaugraBe 120 V AC 1 Phase 240 V AC 1 Phase 240 V AC 3 Phasen 480 VAC 3 Phasen 600 VAC 3Phasen<br />

B 0 4 0 4 0 4 2 2 0 4 2 2 0 75 4 0<br />

0 75 0 75 0 75 3 7 0 75 4 0 1 5<br />

1 1 1 5 1 5 1 5 2 2<br />

C 2 2 5 5 5 5 11 0 5 5 11 0<br />

7 5 7 5 7 5<br />

r<br />

0<br />

0<br />

Al<br />

PowerFlex 40 Frequenzumrichter<br />

io In<br />

0000<br />

u<br />

m<br />

o m<br />

Abmessungen sind in mm angegeben<br />

Gewicht ist in kg angegeben<br />

ell<br />

l<br />

Versand<br />

A B C 0 E F gewlchl<br />

8 100 180 136 87 168 874 2 2<br />

C 130 260 180 116 246 4 3<br />

Kommunikation HF Filter Optionskit gemiiB IP30 NEMA 1UL Typ 1<br />

FU<br />

FU<br />

Option BaugroBe B BaugroBe C<br />

A Komm Abdeckung 25 25<br />

8 EMV Netzfilter 50 60<br />

C EMV Netzfiller 229 309<br />

0 IP30INEMA1UL Typ 1 33 60<br />

IP30INEMA1UL Typ 1 64 60<br />

lOr Komm Abdeckung<br />

U s Allen Bradley Drives Technical Support<br />

Tel 1 262 512 8176 Fax 1 262512 2222 Email support@dnves ra rockwell com Online www ab comlsupportJabdrtves<br />

Publikation 22B QSOOI B DE P Januar 2004<br />

Rockwell<br />

Automation<br />

Ersetzt Publikation vom Oktober 2002 Copyright@2004 Rockwell Automation Inc Aile Rechtevorbehalten Gedruckt in Taiwan<br />

152<br />

022


tlm<br />

fA<br />

fA<br />

fA<br />

fA<br />

fA<br />

Variateur de vitesse c a<br />

PowerFlex 40<br />

FRN 2 xx<br />

Guide de mise en route<br />

Ce guide de mise en route resume les etapes de base necessaires a I installation<br />

la mise en service et laprogrammation du variateur de vitesse c a PowerFlex 40<br />

Les informations foumies ne remplacent pas Ie manuel utilisateur et<br />

s adressent uniquement au personnel qualifie pour la maintenance des<br />

variateurs<br />

Pour obtenir les informations detaillees sur Ie PowerFlex 40 dontles instructions<br />

relatives a laCEM les remarques sur les applications et les precautions associees<br />

reportez vous ala publication 22B UMOOI Manuel utilisateur du<br />

PowerFlex 40 disponible sur Ie CD foumi avec Ie variateur ou sur Ie site<br />

Internet wwwab commanuals dr<br />

Precautions generales<br />

ATTENTION Ie variateur contient des condensateurs a haute tension dont Ie<br />

dechargement prend un certain temps apres la coupure de I alimentation secteur<br />

Avant d intervenirsur Ie variateur verrouillezIisolation entre Ie secteur et les<br />

entrees d alimentation R S T Ll L2 L3 Attendez trois minutes que les<br />

condensateurs se dechargent et atteignent des niveaux de tension non dangereux<br />

L inobservation de cette procedure peut eogendrer des blessures graves ou<br />

mortelles<br />

Des voyants eteints n indiquent pas que les condensateurs se sont decharges et<br />

ont atteint des niveaux de tension non dangereux<br />

ATTENTION unedeterioration de Iequipement etlou des blessures peuvent<br />

survenir si Ie A092 Essai Demar Auto ou A094 Demarr Mise<br />

parametre<br />

Srr<br />

est utilise dans une application inappropriee Ne pas utiliser cette fonction sans<br />

avoir pris en consideration les lois locales nationales et internationales de<br />

meme que les normes les reglementations ou 1es recommandations de<br />

I industrie<br />

ATTENTION seul un personnel qualifie familiarise avec les variateurs c a et<br />

les equipements associes doit concevoir ou proceder aIinstallation la mise en<br />

serviceet la maintenance du systeme L inobservation de ces regles peut<br />

entrainer des blessures etlou des degats materiels<br />

ATTENTION ce variateur contient des composantset des sous ensembles<br />

sensibles aux decharges electrostatiques ESD Des precautions de contrale<br />

delelectricite statique sont requises lors deIinstallation du test de la<br />

maintenance ou de la reparation de cet appareil Les composants risquent d etre<br />

deteriores si les procedures de contrale des decharges electrostatiques oe sont<br />

pas respectees Si vous n etes pas familiarise avec ces procedures reportez vous<br />

a ladocumentation 8000 4 5 2 Guarding Against Electrostatic ou<br />

Damage<br />

tout autre manuel traitant de la protection contre les decharges electrostatiques<br />

ATTENTION un variateur incorrectement utilise ou installe risque de<br />

deteriorer les compos ants ou de reduire la duree de vie du produit Des erreurs<br />

de cablage ou d application telles qu un moteur sous dimehsionne une<br />

alimentation c a incorrecte ou inadaptee ou des temperatures ambiantes<br />

excessives peuvent provoquer un dysfonctionnement du systeme


Fran ais 2<br />

Instructions de montage<br />

Montez Ie variateur verticalement sur unesurface plate verticale et plane<br />

Taille Taille des vis Couple de serrage Rail DIN<br />

B M4 n 8 32 1 56 1 96 Nm 14 17 lb in 35mm<br />

C M5 n 10 24 245 2 94 Nm 22 26 lb in<br />

Protegez Ie ventIlateur de la poussiere ou des copeaux metalhques<br />

Ne pas exposer 11 un milieu corrosif<br />

Proteger de I humidite et des rayons directs du solei<br />

Degagements minimum pour Ie montage<br />

Voir les dimensions de montage page 16<br />

v 0 V<br />

120 mm<br />

4 7 in<br />

odobo odobo<br />

POD POD<br />

120 mm<br />

4 7 in<br />

0 0<br />

1r l11 1<br />

o o<br />

25 mm<br />

1 0 in<br />

V 0<br />

120 mm<br />

47in<br />

Option de montage A<br />

Pas d espace necessaire odobo odobo<br />

entre es variateurs<br />

6 00 POD<br />

Option de montage<br />

Bfj 0<br />

Temperatures ambiantesde fonctionnement<br />

0<br />

120 mm<br />

4 7 in<br />

tr 11 I I<br />

Temperature ambiante Type de coffret Degagements minimum pour<br />

Minimum Maximum Ie montage<br />

I<br />

40 C 104 F<br />

IP 20fType ouvert Utilisez I option de montage A<br />

10 C 14 F IP 30INEMA I UL Type 11 Utilisez option de montage B<br />

50 C 122 F IP 20fType ouvert Utilisez I option de montage B<br />

1 Cette classification necessite I installation du kit d option PowerFlex 40 IP 30INEMA IUL Type I<br />

Criteres generaux de mise a la terre<br />

Conformite CE<br />

Important retirez Ie cavalier de mise a la terre du MOV si Ie<br />

variateur est installe sur un systeme de distribution sans terre<br />

Serrez la viS apres avoir retire Ie cavalier<br />

D<br />

00000<br />

f ooo<br />

lll<br />

1111<br />

UIf1<br />

Vrr2<br />

wrr3<br />

o<br />

fi<br />

ILJ<br />

Reportez vous au Manuel utilisateur du PowerFlex 40 inclus dansIe CD foumi<br />

avec Ie variateur pour connaitre les details permettant de se conformer aux<br />

DirectivesBasse Tension et Compatibilite Electromagnetique CEM


Specitic tlons fus ib l s et disjoncteurs<br />

Caracteristiques nominales des variateurs<br />

Reference<br />

Caracterlstiques<br />

nomlnales de sortie<br />

22B V2P3Nl04 0 4 0 5 2 3 90 132 1 15 9 0 15 140M C2E CI6 100C12 30<br />

22B V5PON104 0 75 1 0 5 0 90132 245 203 35 140M D8E C20 100C23 56<br />

22B V6PON104 1 1 1 5 6 0 90132 3 0 24 0 40 140M F8E C32 100C37 70<br />

Entree monophasee 200240 V c a 10 f sortie triphasee 0230 V<br />

22B A2P3N104 M 0 5 2 3 180 264 1 15 60 10 140M C2E B63 100C09 30<br />

22B A5PON104 0 75 1 0 5 0 180264 2 45 12 0 20 140M C2E C16 100C12 55<br />

22B A8PON104 1 5 2 0 8 0 180 264 4 0 18 0 30 140M D8E C20 100C23 80<br />

22B AOI2N 1 04 2 2 3 0 12 0 180 264 5 5 25 0 40 140M F8E C32 100C37 110<br />

Entreetriphesee 200240 Vc a 10 sortie triphasee 0230V<br />

22B B2P3Nl04 04 0 5 2 3 180264 1 15 2 5 6 140M C2E B40 l00C07 30<br />

22B B5PON104 0 75 1 0 5 0 180 264 2 45 5 7 10 140M C2E ClO IOQ C09 55<br />

22B B8PON104 1 5 2 0 8 0 180264 4 0 9 5 15 140M C2E C16 100C12 80<br />

22B B012Nl04 2 2 3 0 12 0 180264 5 5 15 5 25 140M C2E C16 100C23 115<br />

22B BOI7N 1 04 3 7 5 0 17 5 180264 8 6 21 0 35 140M F8E C25 100 C23 165<br />

22B B024N 1 04 5 5 7 5 24 0 180 264 11 8 26 1 40 140M F8E C32 100C37 226<br />

22B B033Nl04 7 5 10 0 33 0 180264 16 3 34 6 60 140M G8E C45 100C60 290<br />

Entree trlphasee 380 480 V C a 10 j sortie triphasee0460 V<br />

22B D1P4Nl04 0 4 0 5 14 342 528 1 4 1 8 3 140M C2E B25 100C07 30<br />

22B D2P3Nl04 0 75 1 0 2 3 342 528 2 3 3 2 6 140M C2E B40 100C07 40<br />

22B D4PON104 1 5 2 0 4 0 342 528 4 0 57 10 140M C2E B63 1 OO C09 60<br />

22B D6PON104 2 2 3 0 6 0 342 528 5 9 7 5 15 140M C2E Cl0 100 C09 90<br />

22B D010Nl04 4 0 5 0 10 5 342 528 10 3 13 0 20 140M C2E CI6 l00C23 150<br />

22B D012N104 5 5 7 5 120 342 528 11 8 14 2 25 140M D8E C20 100C23 160<br />

22B D017Nl04 7 5 10 0 17 0 342 528 16 8 184 30 140M D8E C20 100C23 200<br />

22B D024Nl04 11 0 15 0 24 0 342 528 23 4 26 0 50 140M FBE C32 100C43 285<br />

Entree trlphasee 460 600 V c a 10 j sortietrlphasee Hi75 V<br />

22B El P7Nl04 0 75 1 0 1 7 414 660 2 1 2 3 6 140M C2E B25 100C09 40<br />

22B E3PON 1 04 1 5 2 0 3 0 414 660 3 65 3 8 6 140M C2E B40 100 C09 60<br />

22B E4P2Nl04 2 2 3 0 42 414 660 5 2 5 3 10 140M C2E B63 100C09 90<br />

22B E6P6Nl04 4 0 5 0 6 6 414660 8 1 8 3 15 140M C2E Cl0 l00C09 150<br />

22B E9P9N104 5 5 7 5 9 9 414 660 12 1 11 2 20 140M C2E CI6 100 C16 160<br />

22B E012Nl04 7 5 10 0 12 2 414 660 14 9 13 7 25 140M C2E CI6 100C23 200<br />

22B EOI9Nl04 11 0 15 0 19 0 414 660 23<br />

1 24 1 40 140M D8E G25 100C30 285<br />

Fran ais 3<br />

Dissipation<br />

1 Des variateurs 20G240 V c a monophases sont aussi disponibles avec un filtre CEM integre Dans ce cas<br />

Ie suffixede lareference est Nl14 au lieu de Nl04<br />

2 Reportez vous a la publication 140M SGOO1<br />

Bulletin 140M Motor Protectors Selection Guide pour determiner<br />

la taille et la capacite de coupure necessaire a votre application


Fran ais 4<br />

Sortie programmable reals lorme C<br />

Charge r sistive 3 0 A sous30 V cc 3 0 A sous 125 V c a 3 0 A sous240 V c a<br />

Charge Inductive 0 5 A sous 30 V cc 0 5 A sous 125 V c a 0 5 A sous 240 V c a<br />

Fusibles et disjoncteurs<br />

Type de luslble re mmand UL Ciassa J CC T ou Type esaa 600 V 550 V ou quivalent<br />

DisjoncleulS r8<br />

XJmmand s disjoncteurs HMCPou quivalants<br />

Fonctionnalites de protection<br />

o @Yul5Oac c CSA22 2 e<br />

EMC Dlrecfi 89<br />

LV EN 50178 EN 60204<br />

EMC EN61800 3EN50081 1 EN50082 2<br />

c<br />

Sorties oplo<br />

30 V cc 50 mA<br />

Non Inductil<br />

Sorlies analogiques 10 bffs<br />

0 10 V 1 kohm mini<br />

4 20 mA 525 ohms maxi<br />

Protection moleur protaction nlre les surcharges 12t 150 pendant 60 s 200 pendant 3s toumit une protection de dasse 10<br />

Surlntensff limite mat rial200 d laut Instantan 300<br />

Surtenslon Entree 100120V c a La dedanchement se produit pour una tension da bus de 405 V c c equivaient Aune tansion d entree de 150 Vca<br />

Entree200240V c a La dOclancl1ement sa produipour una tansion de bus da 405 V cc 0quivaIent Aune tanslond entrBe de 290 V ca<br />

Entree 380 460 V c a Le dOclanchement se produipour une tansion da bus de al 0 V c c equivaient Aune tansion d entree de 575 V c a<br />

Entree460600 V C a La dOclanchement sa produit una<br />

pour tanslon de bus da 1005V c c Bquivalent Aune tBl15ion dentree de 711 V Sous tension<br />

ca<br />

Entree 100120 V ce La dOclenchement sa produi pour une lension de busde 20 V C c<br />

Auna tBl15ion dentree de75 Vca<br />

Entree 2IlO 24O V ca La dOclanchemant sa produit pour iequivalent<br />

una tensJon de busde 210 V cc OquIvaIentAuna tension dentree de 150V ca<br />

Entree 380 480 V ca La dOclenchement sa produit pour una tension de busde 390 V cc equivalent Auna tension dentree da275 V ca<br />

Entree 46O roO V ce Si P042 3 Tens Elevee Ie dOclenchement sa produit pourunetension de bus de 487 Vcc<br />

OQuivalent A una tensiondentree de 344 V cal Si P042 2 Tens Faibla 0 la dOcIenchemant sa produit pour unetensionde busde 390V cc<br />

equivalent A une tension dentree de 275 V c a<br />

Tenus de Is commands BUX mlcros coupures Is tenuBminimum aux microcoupures est de0 5 s valeur typique 2 s<br />

Tenus BUX microcoupures d alimentBtfon 100 ms<br />

Freinage dynamique<br />

IGaT interne de freinage lnclus pour lautes les puissances Pour connaitre les informations de commandede la resistance de freinage<br />

reportez vous A I annexe B du Manuel utilisateur du PowerFlex 40 disponlble sur Ie CD


Cablage de puissance<br />

Section du cablage d alimentation<br />

Non blinde 600 V 75 C 167 F THHNfTHWN<br />

Blinde 600 V 75 C ou 90 C 167 F ou 194 F RHH RHW 2<br />

Blinde pour chemin de ciible 600 V 75 C ou 90 C<br />

167 F ou 194 F RHHlRHW 2<br />

Bornier de puissance<br />

Bornier 1<br />

Description<br />

AIL 1 S L2 Entree monophasee<br />

AIL 1 SL2 T L3 Entree triphasee<br />

fi1n<br />

Conducteur de cuivre<br />

recommande<br />

Isolation 0 4 mm site sec<br />

Anixter OLF 7xxxxx<br />

Belden 29501 29507 ou<br />

equivalent<br />

Anixter 7V 7xxxx 3G<br />

Shawflex 2ACD 3ACD ou<br />

equivalent<br />

Fran ais S<br />

UfT1 Vers UfT1 moteur<br />

Permutez deux<br />

conducteurs moteur<br />

VfT2<br />

Vers VfT2 moteur<br />

quelconque pour modifier<br />

WfT3 Vers WfT3 moteur Ie sens de rotation avant<br />

P2 PI<br />

Connexion de la self de bus c c Variateurs de taille C seulement<br />

Le variateur de taille C est liVre avec un cavalier entre les bornes P2<br />

et PI Retirez ce cavalier seulement quand une self de bus c c doit<br />

etre connectee Le variateur ne se metlra pas sous tension si un<br />

cavalier ou une self n est pas connecte<br />

DC DC Connexion du bus C C<br />

BR BR Connexion de la resistance de freinage<br />

@ Terre de securite PE<br />

I<br />

Important les vis des bornes peuvent se desserrer pendant Ie transport Verifiez que toutes les<br />

vis des bornes sont serrees avec Ie couple recommande avant de metlre Ie variateur sous tension<br />

Specification du bornier de puissance<br />

Taille Section maxi du conducteur 2 Section mini du conducteur 2 Couple<br />

B 5 3 mm2 10 AWG 1 3 mm2 16 AWG 1 7 2 2 Nm 16 19 lb in<br />

C 8 4 mm2 8 AWG 1 3 mm2 16 AWG 2 9 3 7 Nm 26 33 lb in<br />

2 Sections maximumminimum que Ie bornier accepte Ce ne sont pas des recommandations


Fran ais 6<br />

Conditionnement de I alimentation<br />

Conditlonnement de I entree d alimentation Action corrective<br />

Basse impedance de Iigne reactance de ligne inferieurea I Installez une self de Iigne ll<br />

Transformateur d alimentation superieur a 120 kVA<br />

ou un transformateur d isolement<br />

ou une self de bus seulement sur<br />

les variateurs 5 5 11 kW 7 5 15 CV<br />

Ligne passMant des condensateurs de correction du Installez une self de Iigne<br />

facteur de puissance ou un transformateur d isolement<br />

Ligne ayant de frequentes coupures d alimentation<br />

Ligne a nt des surtensions transitoires superieures<br />

a 6000 foudre<br />

Tension entre phase et terre superieure 125 de la Retirez Ie cavalier de mise a laterre<br />

tension entre phases<br />

du MOV<br />

Systemes de distribution sans terre<br />

au installez si necessaire un<br />

transformateur d isolement dont Ie<br />

secondaire est mis a la terre<br />

Configuration triangle 240 V Installez une self de ligne<br />

1 Pour connaitre les informations de commande des accessoires reportez vous a I annexe B du<br />

Manuel utilisateur du PowerFlex 40 disponible sur Ie CD<br />

Recommandations de cablage des E1S 2<br />

Type s de conducteur Description Valeur nomlnale<br />

minimum d isolation<br />

Belden 8760 9460 0 8 mm2 18AWG paire torsadee 100 blindee<br />

ou equiv avec drain 300 V<br />

Belden 8770 0 8 mm2 18AWG 3 cond blinde uniquement<br />

60 C<br />

140 F<br />

ou equivalent pour Ie pol ext<br />

2 Si les fils sont courts et enfermes a I interieur d une armoire n ayant pas de composants sensibles<br />

I utilisation de fil blinde n est pas indispensable mais toujours preferable<br />

Specifications du bornier d EtS<br />

Tallie Section maxi du conducteur 3 Section mini du conducteur 3 Couple<br />

Bet C 1 3 mm2 16 AWG 0 13 mm2 26 AWG 0 5 08Nm 4 7 lb in<br />

3 Sections maximumminimum tolerees par Ie bornier il ne s agit pas des recommandations<br />

Pour connaltre les longueurs maximales recommandees pour les dibles<br />

d alimentation et de commande reportez vous au Manuel utilisareur du<br />

PowerFlex 40 disponible sur Ie CD


1<br />

Relais N O<br />

Commun relais<br />

Resistif<br />

lnductij<br />

Relais N F<br />

Bornier de commande<br />

Schema fonctionnel du cablage de com mande<br />

4<br />

Validercavaliers Rl<br />

R2<br />

01<br />

02<br />

03<br />

Arret 1<br />

DirectionlMarcha Arr<br />

I<br />

r<br />

Commun TOR<br />

SNK SRC 04<br />

t r Entree Dig 1<br />

I I<br />

OS<br />

06<br />

Entrea Oig 2<br />

i<br />

I<br />

07<br />

Entrea Dig 3<br />

I<br />

l<br />

l<br />

u<br />

24 V<br />

0<br />

08<br />

09<br />

11<br />

Entree Oig 4<br />

Commun Opto<br />

24 V C c<br />

10V c c<br />

12<br />

Entree 0 10 V<br />

oUiIO V<br />

13<br />

14<br />

15<br />

16<br />

Commun analoglqua<br />

Entrea 4 20mA<br />

Sortiaanalogique<br />

R3 17<br />

Sortieopto 1<br />

I I I<br />

I 30Vc c<br />

18<br />

Sortie 0 to 2<br />

SOmA<br />

non inductif<br />

1<br />

Blindage RS465 DSI<br />

19<br />

i<br />

i<br />

1<br />

0 10V<br />

Selection sortia analogi que<br />

8<br />

VO<br />

V<br />

20 mA Valider cavaliars<br />

V<br />

01 02 03 04 05 06<br />

Rl R 2 R3<br />

SNK<br />

aD aD aD 8<br />

SRC<br />

4<br />

ENBL<br />

07 06 09<br />

aD<br />

40 V c a<br />

30 A<br />

aSA<br />

Important la borne 01 des E1S est toujours<br />

une entree d arret en roue libre saul quand P036<br />

Source Demarrage est regie pour la commande<br />

3 fils En commande 3 fils la borne 01 des E1S<br />

est contr61ee par P037 Mode Arret Toutes les<br />

autres sources d arret sont contr61ees par P037<br />

Mode Arret<br />

1<br />

I I<br />

I<br />

Fran ais 7<br />

Important Ie variateur est livre avec un cavalier installe entre les bornes 01 et 11 du bornier des E1S Retirez ce<br />

cavalier quand vous utilisez la borne 01 des E S comme entree d arret ou de validation<br />

2 Commande deux fils representee Pour la commande 3 fils utilisez une entree impulsionnelle sur la borne 6io<br />

02 des E1S pour commander un demarrage Utilisez une entree a encliquetage lfO sur la borne 03 des E1S<br />

pour modifier Ie sens de rotation<br />

3 Quand vous utilisez une sortie opto avec une charge inductive telle qu un relais installez une diode de protection<br />

en parallele sur Ie relais comme indique pour eviter d endommager la sortie<br />

4<br />

Quand Ie cavalier ENBL est retire la borne 01 des E1S agira toujours en tant que validation cablee provoquant un<br />

arreten roue libre Pourplus d inforrnations reportez vous au manuel utilisateurdu PowerFlex 40 disponible sur Ie CD<br />

3<br />

24V<br />

P036 Source Demarrage Arret Arr@t borne01 des EIS<br />

Clavier Selon P037 Roue Iibre<br />

3 Fils Selon P03 Seton P03l<br />

2 Fils Selon P03l Rouelibre<br />

Port RS4aS Seton P037 Rouetibre


Fran ais 8<br />

Designations du bornier des E1S de commande<br />

NO Signal Par delaut Description Paramo<br />

RI Relais N O Oefaut Contact normalement 04vert pour relais de sortia A055<br />

R2 Commun relais Commun pour relais de sortie<br />

R3 Relais N F Defaut Contact normalement ferme pour relaisde sortie A055<br />

Micro interrupteur de<br />

selection de la sortie<br />

analogique<br />

Micro interrupteur<br />

NPNIPNP<br />

1<br />

01 Arret<br />

0 10V Regie la sortie analogique pour la tension ouIe courant Le reglage doit<br />

correspondre II celui deA065 Sel Sort Ana<br />

Source PNP Le reglage du micro interrupteur permetde cabler les entrees en NPN<br />

ou en PNP<br />

Roue libre Le cavalier installe en usine ou une entree normalement P036 1<br />

fermee doit etre presentpour que Ie variateur puisse<br />

demarrer<br />

02 Oemarrage Marche Inactif Par defaut la commande provient du ciavier integre Pour P036 P037<br />

avant desactiver la marchearriere voir A095 Oesact Arriere<br />

03 OirectionlMarche Arr Inactif P036 P037<br />

A095<br />

04 Commun TOR Pour les entrees TOR Isolation electronique entre les entrees<br />

TORetles E1S analogiques et les sorties opto<br />

05 Entree Dig 1 Freq Presel Programme par A051 Sel Entr Dig 1J A051<br />

06 Entree Oig 2 Freq Presel Pr09ramme par A052 Sel Entr Di9 2 A052<br />

07 Entree Dig 3 Local<br />

08 Entree Dig 4 A Coups Avnt<br />

Programme par A053 Sel Entr Oig 3 A053<br />

Programme par A054 Sel Entr Oig 4 A054<br />

09 Commun Opto Pour les sortiesopto couplees Isolation electronique entre les<br />

sorties optoet les E1S analogiques et les entrees TOR<br />

11 24 V c c Reference aucommun TOR<br />

Alimentation des entrees TOR fournie par Ie variateur<br />

intensite de sortie maximum est 1 00mA<br />

12 10Vc c Reference au commun analogique P038<br />

13 Entree 10 V 2<br />

Alimentation fournie par Ie variateur pour la potentiometre<br />

externe 0 10 V<br />

intensite de sortie maximum est15 mA<br />

Inactif Pour I entree d alimentation externe 010 V unipolaire P038<br />

ou 10 V bipolaire impedance d entree 100 kohms A051 A054<br />

ou Ie curseur du potentiometre A123 A132<br />

14 Commun analogique Pour I entree 0 10 V ou 4 20 mA Isolation electronique entre<br />

15 Entree 4 20 mA 2<br />

les entrees et les sorties anal09iques et les E1S TOR etles<br />

sorties opto<br />

Inactif Pour une entree d alimentation externe 4 20 mA P038<br />

impedance d entree 250 ohms A051 A054<br />

16 Sortie enalogique SrtFreq 010 La sortie analogique pardefaut est 0 10 V Pour convertir en<br />

valeur decourant commutez ie micro interrupteur<br />

A065 A066<br />

de<br />

selection de la sortie analogique sur Ie choix 0 20 mA<br />

Programmez avec A065 Sel Sort Ana La valeur<br />

analogiqua maxi peutetre mise II I I echelle II aide de<br />

A066 Sortie Ana Haute<br />

Charge maximum 4 20 mA 525 ohms 10 5 VI<br />

0 10 V 1 kohm 10 mAl<br />

17 Sortie opto 1 Mot en Mrche Programmez avec A058 Sel Sort Opto 1 A058 A059<br />

18 Sortie opto 2 FreqAlleinte Programmez avec A061 Sel Sort Opto 2 A061 A062<br />

19 Blindage RS485 OSI La borne doit We reliee II la terre de securite PE quand on<br />

1 Voir les notes de pied 1 et 4 en page 7<br />

utilise Ie port de communication RS485 OS I<br />

2 Les entrees 0 10 V et 4 20 mA sont des voies d entree distinctes qui peuvent tre connectees simultaOllment<br />

Les entrees peuvent tre utilisees independamment pour la commande de vitesse ou conjointement lorsqu on<br />

fonctionne en mode PID<br />

A132<br />

A064<br />

A064


Preparation<br />

de la mise en service du variateur<br />

Fran ais 9<br />

ATTENTION pour proceder a lamise en service du variateur vous devez<br />

Ie mettre sous tension Certaines des tensions presentes sont au potentiel de<br />

l alimentation Pour eviter tout risque d electrocution ou de materiel Ia<br />

degat<br />

procedure suivante doit etre executee uniquement par un personnel qualifie<br />

Vous devez lireattentivement et comprendre laprocedure avant de commencer<br />

Si un evenement ne se produit pas pendant I execution de cette procedure ne<br />

continuez pas Retirez toutes les alimentations y compris les tensions de<br />

commande foumies parl utilisateur Des tensions utilisateur peuvent etre<br />

presentes meme si Ie variateur n est pas alimente par la source c a principale<br />

Corrigez Ie dysfonctionnement avant de continuer<br />

Avant de mettre Ie variateur sous tension<br />

o 1 Assurez vous que toutes les entrees sont correctement connectees auxbomes<br />

correspondantes<br />

o 2 Verifiez sur Ie sectionneur que la tension d alimentation ca est dans les<br />

tolerances de la valeur nominale du variateur<br />

o 3 Verifiez que toute alimentation de commande TOR est a 24 volts<br />

o 4 Verifiez que Ie reglage du micro interrupteur NPNIPNP correspond avotre<br />

systeme de cablage de commande PourI emplacement voir page 7<br />

Important Ie systeme de commande par defaut est PNP La borne Arret est<br />

cablee bomes 0 et I des E S pour autoriser Ie demarrage a partir<br />

du clavier Si Ie systeme de commande est modifie en NPN Ie<br />

cavalier reliant les bomes 0 et I des E S doit etre retire et installe<br />

entre les bomes 0I et 04<br />

o 5 Verifiez que I entree Arret est presente sinon Ie variateur ne pourra pas<br />

demarrer<br />

Important si laborne 01 des E S est utilisee comme entree d arret Ie cavalier<br />

reliant les bomes 0 et I doit etre retire<br />

Mise sous tension du variateur<br />

o 6 Appliquez I alimentation c a et les tensions de commande au variateur<br />

o 7 Familiarisez vous avec les fonctionnalites du clavier integre voir page<br />

suivante avant de regler tout parametre du groupe de programmation<br />

Commandes Demarrage Arret Sens et Vitesse<br />

Les valeurs par defaut des parametres permettent la commande du variateur a<br />

partir du clavier integre Aucune programmation n est necessaire pour demarrer<br />

arreter modifier Ie sens de rotation et contrOler la vitesse a partir du clavier<br />

integre<br />

Important pour desactiver la marche arriere voir A095 Desact ArriereJ<br />

Si un defaut apparait ala mise sous tension reportez vous ala page 17 pour<br />

I explication du code de defaut Pour des informations detaillees sur Ie<br />

depannage reportez vous au Manuel utilisateur du PowerFlex 40 disponible<br />

sur Ie CD foumi avec Ie variateur


Fran ais 1 0<br />

Clavier integre<br />

@<br />

o<br />

UH<br />

P nj UJ<br />

00 00<br />

GDG C3<br />

U 10<br />

Menu<br />

NO DEL Etat DEL Description<br />

d<br />

p<br />

R<br />

F<br />

Description<br />

Groupe offlchoge lecture seute<br />

Affiehe les oonditions do lonclionnemenl du varleleur<br />

courammenl visualisees<br />

Groupo deprogrommotlon de baso<br />

R9roupo les fonctlons progremmables les plus<br />

courammenl ulilisees<br />

Groupe de programmetlon 6volu6e<br />

Rassemble Ie reste des fonctions programmables<br />

Indlceteurde dMoul<br />

USle des oodes oorrespondanl A des oondilions de<br />

d6taulsp6dfiques S affiehe uniquemenl en cas de<br />

d6faut<br />

0 Etat Marche Sens Rouge fixe Indique que Ie variateur fonctionne et commande Ie sens de rotation<br />

du moteur<br />

Rouge clignotant Le variateur a re u I ordre de changer Ie sens de rotation Indique Ie<br />

sens de rotation reel du moteur pendant la deceleration jusqu a zero<br />

@ Afficheur Rouge fixe Indique un numero de parametre une valeur de parametre ou un code<br />

alphanumerique<br />

de defaut<br />

Rouge clignotant Un seul chiffre c1 notant indique que ce chiffre peut etre modifie<br />

Le clignotement e tous les chiffres indique une condition de defaut<br />

@ Unites affichees Rouge fixe Indique les unites de la valeur du para metre affiche<br />

0 Etat Programmation Rouge fixe Indique que la valeur du parametre peut etre modifiee<br />

0 Etat Defaut Rouge c1ignotant Indique que Ie variateur est en defaut<br />

0 Etat Potentiometre Vert fixe Indique que Ie potentiometre du clavier integ e est actif<br />

8 EtatTouche Vert fixe Indique que la touche DemarTage du clavier integre est active<br />

Demarrage<br />

La touche Inversion est egalement active saul si elle est desactivee<br />

par A095 Desact Arriere<br />

NO Touche Nom Description<br />

i Echappement Recule d une etape dans Ie menu de programmation<br />

Annule la modification d une valeur de para metre et quitte Ie mode<br />

Programmation<br />

0<br />

@ Selection Avance d une etape dans Ie menu de programmation<br />

Selectionne un chiffre quand on affiche une valeur de parametre<br />

GDGD Fleche Haut Parcourent les groupes et les parametres<br />

Fleche Bas Augmente diminue la valeur d un chiffre clignotant<br />

8 Entree Avance d une etape dans Ie menu de programmatlon<br />

Sauvegarde la modification d une valeur de parametre<br />

d Potentiometre Sert a controler fa vitesse du variateur etat par defaut est Controle par Ie parametre P038<br />

actif<br />

CD Marche Sert a mettre Ie variateur en marche etat Controlee par Ie parametre P036<br />

par defaut est actif<br />

QJ<br />

Arrlere Sert a inverser Ie sens de rotation commande par Ie variateur<br />

etat par defaut est actif<br />

Controlee par les parametres P036 et A095<br />

Arret Sert a arreter Ie variateur ou effacer un defaut<br />

Cette touche est toujours active<br />

Controlee par Ie parametre P037


Etape<br />

Affichage et modification des parametres<br />

Fran ais 11<br />

Le dernier parametre du groupe Affichage selectionne par I utilisateur est memorise quand<br />

I alimentation est coupee il est affiche par defaut lorsque que I alimentation est retablie<br />

exemple qui suit monfre les fonctions de base du clavier integre et del afficheur II fournit les<br />

instructions de navigation de base et montre comment programmer Ie premier parametre du groupe<br />

Programmation<br />

1 A la mise sous tension Ie dernier numero de<br />

parametre du groupe Affichage selectionne par<br />

I utilisateur s affiche brievement en clignotant Puis<br />

i ecran affiche par defaut la valeur actuelle de ce<br />

parametre Iexemple montre la valeur de dOOl Freq<br />

Sortie avec Ie variateur arrete<br />

2 Appuyez une fois sur Esc pour afficher Ie numero du<br />

parametre du groupe Affichage qui apparait a la mise<br />

sous tension Le numero du parametre se met a<br />

c1ignoter<br />

3 Appuyez de nouveau sur Ese pour entrer dans Ie<br />

menu de groupe La lettre du menu de groupe se met<br />

a clignoter<br />

4 Appuyez sur Fleche Haut ou Fleche Bas pour<br />

parcourir Ie menu de groupe d P et A<br />

5 Appuyez sur Enter ou Sei pour entrer dans un groupe<br />

Le chiffre de droite du dernier parametre affiche dans<br />

ce groupe se met a c1ignoter<br />

6 Appuyez sur Fleche Haut ou Fleche Bas pour faire<br />

defiler les parametres de ce groupe<br />

7 Appuyez sur Enter ou Sel pour voir la valeur d un<br />

parametre Si vous ne voulez pas modifier la valeur<br />

appuyer sur Ese pour retourner au numero du<br />

parametre<br />

8 Pour modifier la valeur du parametre appuyez sur<br />

Enter ou Sel pour passer en mode programmation<br />

Le ehiffre de droite se met a clignoter et Ie voyant<br />

Program s allume si Ie parametre peu lIre modifie<br />

9 Appuyez sur Fleehe Haut ou Fleche Bas pour changer<br />

la valeur du parametre Si vous Ie souhaitez appuyez<br />

sur Sel pour vous deplacer de ehiffre en chiffre ou de<br />

bit en bit Le chiffre ou Ie bit que vous pouvez modifier<br />

se met a elignoter<br />

10 Appuyez sur Ese pour annuler une modification Le<br />

chiffre cesse alors de elignoter la valeur precedente<br />

est retablie est Ie voyant Program s eteint<br />

Ou<br />

Appuyez sur Enter pour memoriser la modification Le<br />

ehiffre cesse alors de clignoter et Ie voyant Program<br />

s eteint<br />

11 Appuyez sur Ese pour relourner a la liste des<br />

parametres Continuez d appuyer sur Esc pour quitter<br />

Ie menu de programmation<br />

Si Ie fait d appuyer sur Esc ne modifie pas I affichage<br />

alors dOOl Freq Sortie est affiche Appuyez sur Enter<br />

ou Sel pour entrer dans Ie menu de groupe<br />

Touche s<br />

jJou @<br />

ou@<br />

C0ou@<br />

ou@<br />

C0ou@<br />

3<br />

ou@<br />

Exemples d affichage<br />

VOLTS<br />

n<br />

U Unlo<br />

PROGRAM FAULT<br />

o 0<br />

Id<br />

n n<br />

o U u<br />

PROGRAM FAULT<br />

o 0<br />

aa<br />

PROGRAM FAULT<br />

o 0<br />

P a 3<br />

PROGRAM FAULT<br />

o 0<br />

PROGRAM<br />

o<br />

2 J<br />

FAULT<br />

0<br />

2 3 Q<br />

PROGRAM FAULT<br />

0<br />

VOLTS<br />

J<br />

10<br />

VOLTS<br />

0 AMPS<br />

o HERTZ<br />

unlOVOLTS<br />

2 2 unlOVOLTS<br />

PROGRAM FAULT<br />

o 0<br />

IP 0 3 H<br />

PROGRAM FAULT<br />

o 0


Fran ais 12 Pour plus d inlormations sur les parametres consultez Ie manual utilisateur du PowerFIax 40 disponlble sur IeCD<br />

Parametres du groupe Affichage<br />

NO Parametre MlnJMax Affichage Optlons<br />

d001 iFreq Sortia O O IFrequence Maxi 0 1 Hz<br />

d002 Freq Commandea O O Frequence Maxi 0 1 Hz<br />

d003 Intanslte Sortie O OOAntensite varlateur x 2 0Q1 A<br />

d004 Tansion Sortie OITension nominale variateur 1 V c a<br />

dOOS Tansion Bus CC Depend du type de variateur 1 V c c<br />

d006 Etat Variataur 0 1 1 Condition vraie IliI 3 Bil2 tlIl1 BiLl<br />

Endeceleration En acceleration Avant En marcha<br />

d007 Code Delaut x F2F122 Fl<br />

d009<br />

dOlO Visu Process 0 00 9999 0 01 1<br />

d012 Source Commande 0 9 rence de vitesse Bit 0 Commands demarra e<br />

Voir P038 9 Freq ACOups Voir P036 9 A Coups<br />

1 d013 Elat Entr Cda 0 1 Entree presente IliI 3 Ili1l tlIl1 BiLl<br />

Tst FrnDynDN Entree Arret Ent SansAn Ent MrchlAvt<br />

d014 Etat Entr Digit 0 1 1 Entrea presenta IliI 3 Bil2 tlIl1 BiLl<br />

Entree Dig 4 Entree Dig 3 Entrea Dig 2 Entree Dig 1<br />

d01S IEtat Comml 0 1 1 Condilion vraia Iita Bil2 tlIl1 BiLl<br />

En DSI Tx Ax<br />

d016 Varslon Logi<br />

el 1 00 99 99 0 01<br />

dOl7 Typa Variateur 1001 9999 1<br />

d018 Tamps Foncl Var 0 9999 h 1 10h<br />

d019 Donneas Pt Test O FFFF 1 Hexadecimal<br />

d020 Entr Ana 0 10 V 0 0 1000 0 1<br />

d021 Entr Ana 4 20 mAl 0 0 100 0 0 1<br />

d022 Puissanca Sortie O OO Puissance Variataurx 2 0 01 kW<br />

d023 IFact Puiss Sort 0 0180 0 dag 0 1 dag<br />

d024 Temperalure Var 0 120 C 1 C<br />

d025 Elat Compleur 0 9999 1<br />

d026 Etat Temporisat 0 0 9999 0 1 s<br />

d028 Etape Etat Log on 1<br />

d029 ICourent Couplal O OO Intensite variateur x 2 0 01 A<br />

Mise en service intelligente avec Ie groupe de parametres debase<br />

de programmation<br />

Le PowerFlex 40 est con upour simplifier et optimiser la mise en service Le groupe Programme<br />

contient les parametres les plus couramment utilises<br />

QJ Arrlltez Ie varlateuravant de modifier oe para metre<br />

NO Parametre I MlnJMax AffichagelOptlons Par delaut<br />

P031 Tens Nom Motaurl 120fTension nominaJe varlaleur QJ Aegle<br />

1 VC e Depend du type da variataur<br />

e la valeur da la tension nomlnala Indiquee sur la plaque<br />

slgnaletique du molaur<br />

P032 Freq NomMoteur 115 400 Hz 1 Hz 60Hz<br />

QJ Regie a la valeur de la frequence nominate indiquee sur la<br />

plaque signaletique du moleur<br />

P033 Ilnl Surcl1 Moteur lo o Inlens te nomlnale variateur x 2 0 1 A Depend du type de variateur<br />

IntensUe mateur reglee au maximum admissible<br />

P034 Frequence Mini 10 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

Definit la frequence la plus basse qui sera delivree en<br />

permanence par Ie variateur<br />

P035 Frequence Maxij 10 400 Hz 1 Hz 60Hz<br />

QJ Delini la frequence la plus elevee qui sera delivree par Ie<br />

variateur<br />

P036 ISource Demanaga 10 6 0 Clavier 1 0<br />

QJ Definitlesysteme<br />

1 3 Fils<br />

de commande utilise pour demarrer 1<br />

Ie<br />

variateur<br />

2<br />

3<br />

2 Fils<br />

2FDetNiv<br />

La touche Inversion est egalement active saufsi elie est<br />

desaclivee parA095 Desact Arrlere<br />

4<br />

5<br />

6<br />

2 F Hte Vii<br />

PortComm<br />

Cde AVNTARR


Pour plus d inlormations sur les parametres consultet Ie manuel utilisateur du PowerFlex40 disponible Sur IeCD Fran ais 13<br />

QJ Arretet Ie valiateur avant de modifier ce parametre<br />

NO Parametre I MinJMax Affichage Options Par defaut<br />

P03 Mode Arret 10 9 o Aampe CF<br />

1<br />

1<br />

1<br />

1<br />

1<br />

Mode d arret actil pour toutes les sources d arret c a d davier<br />

2<br />

Aoue Lbr CF<br />

Frein CC CF<br />

marche avant orne 02 des E1Sl marche arriere borne 03<br />

des<br />

3 FrnCCAuto CF<br />

E1S port S485 saul pour les exceptionsindiquees<br />

ci dessous<br />

Important la borne 01 des E1S<br />

4<br />

5<br />

Aampe<br />

cc Roue libre<br />

est toujours une entree d arrel 6 Freinage CC<br />

en roue libre saulquand P036 Source r<br />

Demarrage est regie<br />

Ia<br />

7 cc FreinCC Auto<br />

commande 3 lils En conlrOle 3 lils la borne 01 des<br />

est contrOl par P03 Mode Arret<br />

8<br />

9<br />

AamjlF EM CF<br />

Aamp FmEM<br />

1<br />

entree Arret efface aussi Ie defaut ectil<br />

P038 Ael Vitessel 10 7 0<br />

1<br />

PatVar<br />

Freq<br />

0<br />

Interne<br />

Oefinit la source de la reference de vitesse du variateur<br />

2 EntrDl0V<br />

Important quand A051 ou A052 Sel Entr Dig xl est I<br />

regie pour 3<br />

option<br />

Entr 4 20 mA<br />

2 4 5 6 13 au 14 et que j entree digitale esl active<br />

4 Freq Presel<br />

5 PortComm<br />

de vitesse commandee par ce parametre Pour plus<br />

reportez vous au<br />

1 du Manuel uti isateurdu PowerFlex<br />

40 disponible surcha8itre Ie D<br />

6 Etape Log<br />

Mult EntrAna<br />

A05 A052 A053 ou A054 seront pnonlaires sur la reference<br />

de details<br />

P039 Temps Aceel 11 10 0 600 0 s 0 1 s 10 Os<br />

Oefinit la rampe d accehration pour tautes les augmentations de<br />

vitesse<br />

P040 Temps Decel 11 10 1 600 0 s 0 1 s 10 Os<br />

Etablit la rampe dedeceleration pour toutes les diminutions de<br />

vilesse<br />

P041 Valeurs Defaut 10<br />

QJ Aelablit les valeurs pardelaut de taus les parametres<br />

1 0 PnWAttente I<br />

1 AAZVallDef<br />

P042 Classe Tension 1213 2 Tens Faible 480 V<br />

QJ Etablit la c1asse de tension pour les variateurs 600 V<br />

3 Tens Elevee 600 V<br />

Groupe des parametres evolues<br />

It<br />

NO Parametre MinJMax AffichagelOptions<br />

Par defaut<br />

A051 Sel Entr Dig<br />

lk<br />

0 26 o Inutilisee<br />

13 EnCtrll0V Borne 05des S 1 Ace etDec2 14 Ent Ctrl20mA<br />

4<br />

A052 Sel Entr Dig 21 2 A coups 15 Devalide PID 4<br />

Borne 06des EIS 3 Defaut Aux 16 Incr Pot Mot<br />

A053 Sel Entr Dig 3 4 Freq Presel 17 Deer Pot Mot 5<br />

Borne 07des ES 5 Local 18 Marche Tempo<br />

AOS4<br />

wel Entr QJ<br />

Dig<br />

4k<br />

6 Port Comm 19 Entr Comptr 11<br />

orne 08 des S 7 RAZ defau<br />

8 ArretAamp<br />

20 RAZ Tempo<br />

CF 21 AAZ Compteur<br />

9 ArretALbr CF 22 AAZ Tps Cpt<br />

10 ArrtFrnCC CF 23 EnlrLogl<br />

11 ACoups Avt 24 EntrLog2<br />

12 A Coups Arr 25 Urn Inlens 2<br />

26 OndlrAnalog<br />

A055 Sel Sort Aelais 0 22 0 PrellDefaut 11 EntLogl 0<br />

1 Freq Atteint 12 EnILog2<br />

2 Mol en Mrche 11<br />

13 Log 1<br />

e12<br />

3 Arriera II<br />

14 Loglou2<br />

r 15 Sort EtapLog<br />

16 Sort Tempo<br />

6 Depasmt Freq 17 Sort Complr<br />

7 Surintensite 18 Depl Angl FP<br />

8 Surtens CC 19 Pert Ent It<br />

Essais<br />

Ana<br />

9 Ctr1 Param<br />

n Epuises 20<br />

10 Depass v Ana 21 Del NonAecup<br />

22 Ctrl Frn<br />

EM<br />

A056 Niv SortAelais 0 0 9999 0 1 0 0<br />

A058<br />

Isel Sort Opto 1 022 o A061 Sel Sort Opto<br />

Pre1lDelaut 11 EntLog 1 2<br />

2 1 I<br />

Freq Attaint l 12 Ent Log 2 II<br />

1<br />

2 Mot en Mrche 13 Loglet2<br />

3 Arriere<br />

14 Log 1 ou2<br />

4<br />

SrCharAe Mol 15 Sort 5 Aegul<br />

EtapLog<br />

ampe 16 II<br />

II<br />

Sort Tempo<br />

6 Depasml Freq 17 Sort Coi nptr<br />

7 Surintensite 18 Dept Angl FP<br />

8 SurtensCC 19 Pert Ent Ana<br />

9 Essais Epuises 20 CI11 Param<br />

10 Depass v Ana 21 Del NonAecup<br />

22<br />

CI11 Frn EM<br />

0<br />

0<br />

3


Fran ais 14<br />

Pour plus d informalions sur les parametres consultez Ie manuel utilisataur du PowerFIex 40 disponlble sur IeCD<br />

NO Parama re IMlnJMax Affichage Optlons Par defaut<br />

A059 N Sort Opto<br />

A062 N Sort Opto 2<br />

11 10<br />

0 9999<br />

R 91 ga d AD55 A05e el AD61 Mini lMaxl de AD56 A059 el AD62<br />

6 01400 Hz<br />

7 0 1 eo<br />

e<br />

10 01100<br />

16 0 19999s<br />

17<br />

Ie<br />

20 011<br />

0815volls<br />

19999 PoInls<br />

1 1eOdeg<br />

10 1 0 0<br />

AD64 Log Sort OplO 10 3 11 0<br />

Oplion A064 Logique Sort Opto 1 LogiqueSortOpto2<br />

0 N O normalemenl ouvert N D normalemenl owerl<br />

1 N F norrnalemenllerme N C normalemenl ouvert<br />

2 N D normalemenl owert N F normalement fennel<br />

3 N F normalement lerme N F normalemenl fennel<br />

A065 Sel Sort Anal 10 20 11 0<br />

PI gede Valeurmlnlmale Valeur maximalede sartie Position<br />

Opllon sortie de sortie SortieAneHauteJ mlcro lnterrupteur<br />

O Fr qSorI0 l0 O IOV OV OHz P035 Fr quence MaxlJ 010V 1 SortlntO l0 010V OV OA 200 de In variateur 010V<br />

2 TensSrtO l0 O IOV OV Ovolt 120 de Ie tension nomlnals desortie du variateur olOV<br />

3 PulsSrt010 0 10V OV OkW 200 de Ie puissance nominate du varialeur 010V<br />

4 DalaTstO IO O IOV OV OOOO 65535 Hexa FFFF o IOV<br />

5 Fr qSort 0 20 020mA OmA OHz P035 Fr quence MaxlJ 020 mA<br />

6 Sortlnl020 0 20mA OmA OA 200 de Invarlateur 02OmA<br />

7 TensSrt 0 20 0 20mA OmA Ovolt 120 de Ie tension nominale desortie duvariateur 020mA<br />

e PulsSrt0 20 020mA OmA OkW 200 de la puissance nomlnale du variateur 02OmA<br />

9 DataTsIO 20 0 20mA o mA 0000 65535 Hex FFFF 0 20mA<br />

10 FreqSort 4 20 4 20mA 4mA OHz P035 Fr quence Maxi 0 2OmA<br />

11 SortlnI4 20 4 20mA 4 mA OA 200 de In varlateur 0 20mA<br />

12 TensSrt4 20 4 20mA 4mA Ovolt 120 de la tension nominale de sortie du variateur 0 20 mA<br />

13 PulsSrt 4 20 4 20 mA 4mA OkW 200 dela puissance nominale duvariateur 02OmA<br />

14 DaleTsI4 20 4 20mA 4 mA 0000 65535 Hexe FFFF 0 20mA<br />

15 SrtCpleO IO 010 V OV OA 200 detn variateur 0 10 V<br />

16 SrtCple 0 20 0 20mA OmA OA 200 de Invariateur 0 20mA<br />

17 Sr1C e 420 4 2OmA 4mA OA 200 de In variateur 0 20 mA<br />

Ie PICnslgo lO O IOV OV O 100 0 du reglagede la consigne 0 10V<br />

19 P1CnsI90 20 0 2OmA OmA O 100 0 du reglage de la consigne 0 20 mA<br />

20 PlCnslg 4 20 4 20mA 4mA 0 100 0 du reglage de la conslgne 02OmA<br />

A066 Sortie Ana HauteJ 0 800 1 100<br />

A067 Temps Accel 2 0 0 600 0 s 0 1 s 20 0s<br />

A068 Temps De L 2J 0 1 600 0 s 0 1 20 Os<br />

A069 Freq lnlerne 0 0 400 0 Hz 0 1 Hz 600 Hz<br />

IFreq<br />

A070 PreseL 0 I l 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A071 Freq Presel 1 5 0 Hz<br />

A072 Freq PreseL 2 10OHz<br />

A073 Freq Presel 3 20 0 Hz<br />

A074 Fnlq Presel 4 30 0 Hz<br />

A075<br />

IFreq Presel 5 A076 Freq Presel 6<br />

40 0 Hz<br />

50 0 Hz<br />

A077 Freq Pr s 1 7 1<br />

60 0 Hz<br />

Pour activer Freq Presel OJ reglez P038 Ref Vilesse pour I option 4<br />

Etal de I entree Elatde I enlree EtatdeI enlree<br />

Entree Dig 1 Entree 01g 2 Enlree Dig 3<br />

Bome 05des E1S Borne 06 des E1S Bome 07 des E1S<br />

2<br />

ourceda<br />

Irequence<br />

da r 3tise 2<br />

0 0 0 Fr q Pr s L OJ Temps Accel lJ 1 Temps Dec l lJ<br />

1 0 0 Fr q Pres L 1 TempsAcceL 1J 1 Temps Oec 1 lJ<br />

0 1 0 Freq Pres L2j Temps AcceL 2J 1 Temps Decel 2J<br />

I 1 0 Freq Pre L3 Temps Accel 2J 1 1<br />

Temps Decel 2J<br />

0 0 Fr<br />

q Pres 1 4 1<br />

TempsAcceI IJ TempsDecel lj<br />

1 0 Freq Pre L 5 Temps Accel lJ 1 Temps Dec l lJ<br />

0 1 1 Freq Pres 1 6 Temps Accel 2J 1 Temps Dec 1 2J<br />

1 1 1 Fr q Pres L 7 Temps AcceL 2J 1 Temps Dec 1 2J<br />

Quand Acrel2 etDecel2 sonl assIgnes a una entree dignale et que celie entree eslactive ene est prioritalre sur les<br />

reglagesdecetableau<br />

A07B Freq A CoupsJ I OMFrequence MaxlJ 10 1 Hz 10 0 Hz


Pourplus d in ormations sur les parametres consultez Ie manuel utilisateur du PowerFlex 40 diSponible sur Ie CO Fran ais 1S<br />

NO Parametre IMlnJMax Affichage Options Par defaut<br />

A079 Acc O A Coups 10 1 600 0 s 0 1 s 10 Os<br />

A080 Tps Frein CC 10 0199 9 s 0 1 s 0 0 s<br />

Un reglage de 99 99 s Permanenl<br />

A081 Niv Frein CC O O Intensne vanaleur x 1 8 0 1 A Intensite x 0 05<br />

A082 Sel Resist Frein 099 o Desactive 0<br />

Cl<br />

2 Sans Protect 0<br />

1 Res RA Normale 3 99 du cycle de trevail<br />

CQJ<br />

A083 Courte en S 0 100 1 o Desactive<br />

A084 Select Boost 0 14 Reglages en de la tension nominale 8<br />

Acti seulement quandA 125 Mode Prod Couplej est<br />

I<br />

7 4 11 kW<br />

regie sur 0 VlHz<br />

g u aZrj<br />

cial<br />

Gouole constant<br />

5 15CV<br />

1 30 0 Cple V<br />

0<br />

5<br />

0 0 sans RI 10 100 CpleC<br />

2 35 0 CpleV 6 0 0 11012 5 Cple C<br />

3 40 0 CpleV 7 2 5 CpleC 120 15 0 CpleC<br />

4 45 0 Cple V 8 5 0 Cple C<br />

13 17 5 Cple C<br />

9<br />

7 5 Cple C 140 20 0 Cple C<br />

A085 Boost Demerrege 10 0125 0 0 1 2 5<br />

Acti seulement quandA084 Select Boosl el A 125 Mode Prod Couple sonl mis e 0<br />

A086 Tension Cassure 10 0 100 0 10 1 25 0<br />

Acti seulement quandA084 Select BOOSI etA 125 Mode Prod COuple sont mis e 0<br />

A087 Freq Cassure 10 01400 0 Hz 1 Hz 15 OHz<br />

10<br />

Acti seulement quandA084 Select Boosl et A 125 Mode Prod Couple sont mis e 0<br />

A088 Tension Maxi 20rrension Nominale 1 Vc a Tension Nominale<br />

A089 Lim Inlensite I 0 l llnlensne varialeur x 1 8 0 1 A Intensitex 1 5<br />

It<br />

A090 Sel Surch MOleur 0 2 o Sims declassemenl 1 Dllclass mini 0<br />

It<br />

2 Declass maxi<br />

A091 Frequence MlI 2 0116 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Essai Demar Auto 0 9 1 0<br />

A093 Tps Redemar Aulo 0 0 300 0 s 0 1 s 1 0 s<br />

A094 Demarr MiseSfT 011 o Desactive 1<br />

QJ<br />

II<br />

II<br />

Active 0<br />

A095<br />

QJ<br />

Desac Arriere 011 o Arr Active 1 Arr Des ctve 0<br />

A096 Valid Repr Volee 01 0 Desactive<br />

II<br />

II<br />

A097 Compensation 0 3 o Desactive 2<br />

1<br />

Active 0<br />

Mecanique 1<br />

1 Electrique 3 Les deux<br />

A098 Surinlens Soft O Olllnlensite variateur x 2 0 1 A 0 0 Desactive<br />

A099 Echelle Process 0 11999 9 0 1 30<br />

Al00 RAZ De aut 0 2 0 PreVAttente 0 1<br />

Q<br />

RAZ de aut 0<br />

2 RAZ Mem Tamp<br />

AIOI Verrou Prog 0 9999 o Deverrouille 1 Verrouille 0<br />

Al02 Sel Point Testl 400IFFFF 1 Hexadetimal 400<br />

Al03 Vilesse Comm 015 0 1200 3 9600 3<br />

La variateur doitelre rafnis sous tensionavant 1<br />

que 2<br />

toutemodification puisse affecter Ie fonctionnement du<br />

variateur<br />

2400<br />

4800<br />

4<br />

5<br />

19 2K<br />

38 4K<br />

Al04 Adr Station Comm 247 1 100<br />

11<br />

La varialeur doit etre remis sous tension avant que<br />

loute modification puisse affecter Ie fonctionnement du<br />

variateur<br />

l<br />

fl<br />

Al05 Act PerteComm 0 3 o Deleut 2 Arr 0<br />

1 ArrtRouelbre 3 Continu Dern<br />

Al06 Temps Perte Comml 0 1 60 Os 0 1 5 0<br />

AIOl Format Comm l 0 2 o RTU 8 N 3 RfU BN 2 0<br />

1<br />

La variateur doit tre ramis sous tension avant que<br />

RTU BE l 4 toute modification puisse<br />

RfU 8 E 2<br />

affecter Ie fonctionnement du 2 RfU 8 0 1 5 RfU 80 2<br />

variateur<br />

Al08 Langue 1 10 1 English 6 Reserve II<br />

1<br />

2<br />

Fran is 1 Portugu s<br />

II<br />

fl<br />

3 Espana 8 Reserve<br />

4 Italiano II<br />

9 Reserve<br />

5 Deutsch 10 Nedertands<br />

Al09 Consign Sort Ana 0 0 100 0 0 1 0 0<br />

Al10 EnlAna0 10V Bas 0 0 100 0 0 1 0 0<br />

Q


Fran ais 16<br />

Pour plus d informalions sur les parametres consullez Ie manuel ulilisateurdu PowerRex 40disponible sur Ie CO<br />

NO Parametre MlnJMax Afflchage Options Pardl laut<br />

r51 EniAna 0 1 OV Hlel 0 0100 0 0 1 100 0<br />

AI12 IEniAna 4 20mABas 0 0 100 0 0 1 0 0<br />

Q<br />

rrn IEniAna 4 20mAHlel 0 0 100 0 0 1 100 0<br />

AI14 1Hz Glissml @ In 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

AilS Tps Process Bas 0 00 99 99 0 01 0 00<br />

AI16 Tps Process Hie 0 00 99 99 0Q1 0 00<br />

AI17 IRegul Bus Mode 0 1 o Desective I Active I<br />

AI16 IUm Inlensile 2 O II lnlenslle varialeur x 0 1 A Inlensite x 1 5<br />

1 6<br />

A119 Saul Frequence 0 400 Hz I Hz OHz<br />

A120 Bande Saut Fnlq 1 0 0 30 0 Hz 0 1 Hz 0 Hz<br />

A121 Tps Def Blocage 0 5 o 60 Secondes 3 360 Secondes 0<br />

I 120 Secondes 4 460 Secondes<br />

2 240 Secondes 5 Def Devalide<br />

A122 Perte Enlr Ana 016 0 Desactive 4 Ref Freq Min 0<br />

1 Defaul F29 5 Ref Freq Max<br />

2 Arret 6 RefFnlq Inl<br />

3 R9IZero<br />

AI23 lValid 10V Bipolr 0 1 0 Enlr Unlpolr I Enlr Bipolr 0<br />

AI24 IDesact MLI Varl 0 1 0 Aclive I Oesactive 0<br />

AI25 IMode Prod Couple 0 1 O VlHz I Vect SansCod 1<br />

AI26 Ilnl Nom MOleur 0 I Inlenslle vanaleur x 2 0 1 A I Nomlnale<br />

AI27 IReglage Aulo 0 2 0 PreVAtlenle 2 Reglage Dyn 0<br />

I Reglage Sial<br />

AI26 IChule Tension RI 0 01230 0 V c a 0 1 Vc e Tension Nomlnale<br />

AI29 Ref Inl Flux O OOtlTens Nom MOleurj 0 01 A I Nominale<br />

AI30 Corr PID Hie 0 0 400 0 0 1 60 0<br />

A131 ICorr PID Bas 0 01400 0 0 1 0 0<br />

AI32 Sel Ref PID 0 6 0<br />

I<br />

PID Desaelve<br />

Consigne e<br />

PID<br />

2 Enlr O IOV 7 4 20mA Corr<br />

3 Enlr4 20mA 6 Comm Corr<br />

4 Por1Comm<br />

0<br />

AI33 Sel Retour PID 02 0 Enlrol0V 2 PortComm 0<br />

I Enlr 4 20 mA<br />

AI34 IGain Prop PID 0 00 99 99 0 01 0 01<br />

AI3S Temps Inlegr PID 0 0 999 9 s 0 1 2 0<br />

AI36 Taux<br />

Diff PID 0 00 99 99 lis 0 01 0 00<br />

AI37 IConsigne PIDI 0 0 100 0 0 1 0 0<br />

AI36 Plage Morle PID 0 0110 0 0 1 0 0<br />

AI39 Precharge PIDj 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A140 Elape Log 07 OOOI bAFF 4 chiffres ooFI<br />

A147<br />

a uj<br />

avecIe varialeur<br />

e<br />

p e<br />

n<br />

i<br />

o<br />

l i tb uUm<br />

AlSO Tps Elape Log 071 0 0 999 9 s 0 1 s 30 0 s<br />

AIS7<br />

AI60 Tempo Decl Frein 0 01 II 0 00 s 0Q1 s 2 00s<br />

AI61 Tempo End Frein 0 01 10 00 s 0 01 s 2 oos<br />

AI62 Sel Mode RAZ MOP 01 o Zero Ref MOP I Sauv Rei MOP 1<br />

0


Codes de defaut<br />

Pour effacer un defaut appuyez sur la touche Arret coupez et retablissez<br />

Ialimentation ou donnez aAIDO RAZ Defaut la valeur I ou 2<br />

NO Defaut Description<br />

F2 Entree Auxiliaire 1<br />

Verifiez la cAblage exteriaur<br />

F3 Perte ligna Surveillez la tensiond alimentation trop bassel au recherchez une coupurede l alimentation<br />

F4 Sous tensfon111 Surveillaz la tensiond alimentation trop basse ou recherchez Una coupure de l alimentation<br />

Fran ais 17<br />

F5 Surtension lJ<br />

Verifiez que la ligna C B ne presente pas de conditions de tension elevse ou de transitoires Une surtension du<br />

bus paut auss etre provoquee par la regeneration du moteur Augmentez Ie temps de deceleration ou instaliez<br />

une option de freinage dynamique<br />

F6 Moteur bloque 1 Augmentez remps Accel<br />

xloU rMuisez la charge afin que Ie courant de sortie du variateur ne depasse pasIe courant dOlini par Ie param tre A089 lim Intensitel<br />

F7 Surcharge Moteu J Une charge excessive du meteur existe Aeduisez la charge afin que Ie courant de sortie du varialeur ne depasse<br />

pas Ie courant delini par leparametre P033 Int Surch Moteur<br />

J F8 Surchauffe radiateu veriftez<br />

que les ailettes du radialeur ne sont pas obstruees ou sales Verifiez que la temperatureambianle ne<br />

depasse pas 40 c 104 OF pour<br />

les installafionSIP 30 NEMA 1UL Type 1 ou 50 oc installalions IP 00<br />

122 oF pour les<br />

Verifiez Ie ventilateur<br />

F12 Surintensite materiel Verifiez la programmalion Veriflez que la charge nest pas excessive que Ie reglage du boos C c est correct<br />

que la tension de freinage c c n esl pas Irop eleveeou loul autre cause provoquant un courant excessif<br />

F13 Detaut de terre Yerifiez que Ie moleur elle cablage externe jusqu aux bornes de sortiedu variateur ne presententpas de dllfaut<br />

de mise a la terre<br />

F29 Perte entree analogique 1 Une entree analogique est configuree pour provoquer un detau en cas de perte du signal Une perte de signal<br />

s est produite<br />

F33 Essal Demar Auto Corriger la cause du delaut et effacer manuellemen<br />

F38 Phase U a la terre Wrilfez Ie cAblage entre Ie variateur et Ie moteur Veriliez qu une phase du moteur n est pas a la terre<br />

F39 Phase V a la terre Remplacez Ie variateur sl Ie delautne peut pas<br />

elre efface<br />

F40 Phase Wa la terre<br />

F41 Phases UV CC Verifiez qli il ny apas de court circuit dans le moteur el dans Ie cAblage en sortiedu vatiateur<br />

F42 Phases UW C C Remplacez Ie variateur5i Iedelaut ne peut pas etre efface<br />

F43 Phases VW CC<br />

I I F48 ParamlDelaut Le variateur a reftu ordre d ecrire les valeurs par defaut dans EEPROM Effacez Ie defaut ou coupezet remetlez Ie variateur sous tension Programmez Jes parametres du variateur selon les besoins<br />

F63 Surintensite elec Veriliez les crit res de charge et Ie reglage de A098 Surintens Soft<br />

F64 Surcharge Variateur ROduisez la charge ou augmentezIe temps d acceleralion<br />

F70 Bloc transistor Coupez et remettez lalimentation Remplacez Ie variateur si Ie defaut ne peut pasetre efface<br />

F71 Perte reseau Le reseau de cO mmunication est tombe en defaul<br />

F80 R age automatique La lonction de regfage aUfomalique aete I<br />

cv<br />

interrompue par uliiisateur ou aechouee<br />

F81 Perte Comm Si I adaptateur na pas ete intenlionnellement debranche verifiezIe cablage sur Ie port Remplacez Ie cAblage le<br />

multiplexeur de port les adaptaleurs ou Ie variateur complet selon Ie cas Yerifiez la connexion Un adaptateur a<br />

ete intentionneliement deeonnecte Arretez d utiiiser Al05 Act Perte Comm<br />

Fl00 Checksum parameire Retablissez les valeurs par detau<br />

F122 Delau Carte E1S Coupez at remettez I alimentation Remplacez Ie variateursi Ie defaut ne peut pas etre efface<br />

I<br />

RAZ AutofType delaut en marche Configurez avec les parametres A092 el A093


Fran ais18<br />

Dimensions du variateur<br />

Tailles des PowerFlex 40 Puissances en kW et CV<br />

120 V c a 240 V c a<br />

Tallie Monophase Monophase 240 V c a Trlphase 480 V c a Trlphase 600 V c a Trlphase<br />

8 0 4 0 5 04 0 5 1<br />

04 0 5 2 2 3 0 4 0 5 2<br />

0 75 1 0 4 0 5 0<br />

0 75 1 0 0 75 0 0 75 1 0 3 7 5 0 0 75 1 0 4 0 5 0 1 5 2<br />

1 1 1 5 1 5 2 0 1 5 2 0 1 5 2 0 2 2 3 0<br />

C 2 2 3 0 5 5 5 5 5 11 0 15 0 5 5 11 0 15 0<br />

7 517 5 10 0 7 5 IT10 0 7 5l7 5 10 0<br />

r Ao 1ij<br />

I 5 5 0 22<br />

l<br />

in<br />

c<br />

0<br />

o oo b 0<br />

0000<br />

G<br />

m<br />

Variateur c a PowerFlex 40<br />

01<br />

2l3 Ol<br />

Kits options Communication Filtre RFI IP 30 NEMA 1IUL Type 1<br />

0<br />

m<br />

Varlateur Varlateur<br />

Option tallle B tellle C<br />

A Capol Comm 25 0 98 25 0 98<br />

B Flitre de ligne CEM 50 1 97 60 2 36<br />

C Fillre de ligne CEM 229 9 02 309 12 17<br />

0 IP 30lNEMA 1J JL Type 1 33 1 30 60 2 36<br />

IP30lNEMA llUL Type 1 64 2 52 60 2 36<br />

pour capol Comm<br />

8<br />

Les dimensions sont en millimetres et en pouces<br />

Les poids sont en kilogrammes et en livres<br />

Polds<br />

i A B C 0 E F d expedltlon<br />

8 100 160 136 87 166 87 4 2 2<br />

3 94 7 09 5 35 3 43 6 61 3 44 4 9<br />

C 130 260 180 116 246 4 3<br />

5 1 10 2 7 1 4 57 9 7 9 5<br />

Ol<br />

000<br />

000<br />

DQa JO<br />

CbWcK l<br />

0 0 CDJ oO<br />

D D<br />

Tallie C 22 JBAC<br />

U s Allen Bradley Drives Technlcsl Suppon<br />

Tel 1 262 512 8176 Fsx 1 262 512 2222 Emaii support@dnves ra rocI wall com Online www ab comfsupporVabdnves<br />

Rockwell<br />

Publication 22B QSOOl B FR P Janvier 2004 Automation<br />

Remplace Octobre 2002 Copyright@2004 Rockwell Automation Inc Tous droits reserves Imprlme A Taiwan<br />

222<br />

0 e7


tMl<br />

A<br />

A<br />

A<br />

Inverter PowerFlex 40<br />

a frequenza variabile<br />

FRN2 xx<br />

Avviamento rapido<br />

Questa guida di avviamento rapido riepiloga Ie fasi di basenecessarie per<br />

install are avviare e programmare I inverter PowerFlex 40 a frequenza variabile<br />

Le informazioni contenute in questasede rum sostituisconoil manuale per<br />

I utente e sonodestinate solo a personale specializzato negli interventi di<br />

manutenzione allinverter<br />

Per informazioni dettagliate sui PowerFlex 40 incluse Ie istruzioni sui controllo<br />

delle emissioni evaporative Ie considerazionisull applicazione dell inverter<br />

e Ie relative precauzioni a cui attenersi consultare il Manuale per l utente<br />

PowerFlex 40 pubblicazione 22B UMOOl contenuto sui CD in dotazione<br />

all inverter oppure disponibile all indirizzo wwwab comlmanuals dr<br />

Precauzioni generali<br />

ATTENZIONE l inverter contiene condensatori ad alta tensioneche si<br />

scaricano lentamente dopo larimozione dall alimentazione di rete Prima di<br />

intervenire sull inverter accertarsi che I alimentazione di rete sia isolata<br />

dagli ingressi di linea R S T Ll L2 L3 Attendere treminuti affincM i<br />

condensatori si scarichino per garantire livelli di tensione sicuri La mancata<br />

osservanza di questa precauzione pub causare gravi lesioni 0 morte<br />

Le spie LED imbrunite sui display nonindicano che i condensatori si sono<br />

scaricati ad un livello di tensionesicuro<br />

ATTENZIONE se il parametro A092 Tent riavvio aut A094 Avvio<br />

all accensJ vieneutilizzato in un applicazione inadeguata potrebbero derivarne<br />

danni aile apparecchiature eolesioni a persone Non usare questa funzione<br />

senza considerare codici standard normative 0 direttive del settore siano esse<br />

locali nazionali ed internazionali<br />

ATTENZIONE Ie procedure di installazione avviamento 0 manutenzione<br />

successiva del sistema vanno espletate esclusivamente da personale qualificato<br />

con un adeguata conoscenza degli inverter a frequenza variabile e dei<br />

macchinari ad essi associati La mancata osservanza di questa precauzione<br />

pub causare lesioni a persone e o danni aile apparecchiature<br />

ATTENZIONE questo invertercontiene parti e gruppi sensibili a ESD<br />

Scarica elettrostatica DuranteIe procedure di installazione prova<br />

manutenzione 0 riparazione di questo gruppo si consiglia di osservare Ie<br />

precauzioni per il controllo dell elettrostatica La mancata osservanza di<br />

queste precauzioni pub causare danni ai componenti Qualora<br />

non si avesse<br />

dimestichezza con Ie procedure di controllo deIl elettrostatica consultare la<br />

pubblicazione A B 8000 4 5 2 Guarding Against Electrostatic Damage<br />

altro manuale di pertinenza<br />

0 un<br />

ATTENZIONE un inverter applicato 0 installato in modo incorretto pub<br />

causare danni ai componenti 0 compromettere lavita utile delprodotto Errori di<br />

cablaggio 0 di applicazione quali lataglia minorata delmotore alimentazionein<br />

CA incorretta 0 inadeguata 0 temperature ambiente eccessive possono causare<br />

guasti al sistema


Italiano 2<br />

Considerazioni sui montaggio<br />

Montare I inverter in posizione verticale su unasuperficie piatta ed in piano<br />

Telalo Misura viti Coppla di serraggio Binario DIN<br />

B M4 8 32 1 56 1 96 N m 14 17Iibbre pollici 35mm<br />

C M5 10 24 245 2 94 N m 22 26Iibbre pollici<br />

Proteggere la ventola di raffreddamento evitando polvere 0 particelle<br />

meta1 iche<br />

Non esporre ad atmosfere corrosive<br />

Proteggere dall umidita e dall esposizione diretta ai raggi solari<br />

Distanze minime per iI montaggio<br />

Vedere pagina 16 per Ie dimensioni di montaggio<br />

v 0 1V<br />

120mm<br />

4 7 polL<br />

odobo odobo<br />

a60D a60D<br />

0<br />

0<br />

120 mm<br />

4 7 polL<br />

PuwIltfll li<br />

0 0<br />

1 11r u1<br />

o o<br />

Opzione di montaggio A<br />

essuna distanza Ira gfi<br />

Inverter<br />

Opzi one di montagglo B<br />

rt<br />

Temperature ambiente di funzionamento<br />

odobo<br />

a60D<br />

25mm<br />

I Opoll<br />

1 V 0 1<br />

0 0<br />

PowetR8<br />

120 mm<br />

4 7 polL<br />

odobo<br />

a60D<br />

o 0<br />

120 mm<br />

4 7 polL<br />

I II I<br />

Temperatura ambiente Categorie custodie Distanze mini me per iI<br />

Minima Massima montaggio<br />

1<br />

IP 20fTipo aperto Usare I opzione di montaggio A<br />

40 C 104 F<br />

IO C 14 F IP 30 NEMA lfTipo UL jT1r Usare I opzione di montaggio B<br />

50 C 122 F I P 20fTipo aperto Usare I opzione di montaggio B<br />

ii valore nominale richiede I installazionedi un kit opzionale PowerFlex 40 IP 30 NEMA lfTipo UL 1<br />

Requisiti generali per la messa aterra<br />

Conformita CEE<br />

Importante togliere II ponticello dal MOV a massa se I inverter viene<br />

installato su un sistema di distribuzione senza potenziale di terra<br />

Dopo ia rimozione del ponticello serrare la vite<br />

o<br />

00000<br />

ooo<br />

Consultare il Manua e per ute71fe PowerFlex 40 contenuto suI CD in dotazione<br />

all inverter per dettagli su come garantire la conformita aileDirettive sulla bassa<br />

tensione LV e sulla compatibilita elettromagnetica EMC


Valori nomina Ii inverter<br />

Numero di<br />

catalogo<br />

Specifiche fusibili ed interruttori automatici<br />

Italiano 3<br />

Usclta nominale Ingresso nomlnale Protezione elrculto dl diramazlone Disslpazione<br />

di corrente<br />

kW HP Fusibifi<br />

Ingresso monofase da 100 120 V c a 10 Uscita trlfase da 0 230 V<br />

22B V2P3N104 0 4 0 5 2 3 90 132 1 15 9 0 15 140M C2E C16 100C12 30<br />

22B V5PON104 0 75 1 0 5 0 90132 2 45 20 3 35 140M D8E C20 100C23 56<br />

22B V6PON104 1 1 1 5 6 0 90132 3 0 24 0 40 140M F8E C32 10Q C37 70<br />

Ingresso mcinofase da 200 240V c a 10<br />

1<br />

Uscila lrlfase da 0 230 V<br />

22B A2P3N104 0 4 0 5 2 3 160 264 1 15 6 0 10 140M C2E B63 100C09 30<br />

22B A5PON104 0 75 1 0 5 0 180264 2 45 12 0 20 140M C2E C16 1ODC12 55<br />

22B A6PON104 1 5 2 0 8 0 180264 4 0 18 0 30 140M D8E C20 100 C23 80<br />

22B A012N104 2 2 3 0 12 0 160 264 5 5 25 0 40 140M F8E C32 l00 C37 110<br />

Ingresso trlfase da 200 240 V c a<br />

10 Uscita trifase da 0 230V<br />

22B B2P3N104 0 4 0 5 2 3 180264 1 15 2 5 6 140M C2E B40 100 C07 30<br />

22B B5PON104 0 75 1 0 5 0 180264 245 57 10 140M C2E C10 100C09 55<br />

22B B8PON104 1 5 2 0 8 0 180264 4 0 9 5 15 140M C2E C16 100C12 60<br />

22B B012N104 2 2 3 0 12 0 160264 5 5 15 5 25 140M C2E C16 100 C23 115<br />

22B B017Nl04 3 7 5 0 17 5 180 264 8 6 21 0 35 140M F8E C25 100 C23 165<br />

22B B024N104 5 5 7 5 24 0 180 264 11 8 26 1 40 140M F8E C32 100C37 226<br />

22B B033N104 7 5 10 0 33 0 180264 16 3 34 6 60 140M G8E C45 100C60 290<br />

Ingresso trlfase da 380 480 V c a 10 Uselta trifase da 0 480 V<br />

22B D1 P4Nl04 04 0 5 1 4 342 528 1 4 1 8 3 140M C2E B25 100 C07 30<br />

22B D2P3Nl04 0 75 1 0 2 3 342 528 2 3 3 2 6 140M C2E B40 100C07 40<br />

22B D4PON104 1 5 2 0 4 0 342 528 4 0 5 7 10 140M C2E B63 100C09 60<br />

22B D6PON104 2 2 3 0 6 0 342 528 5 9 7 5 15 140M C2E ClO 100 C09 90<br />

22B D010N104 4 0 5 0 10 5 342 528 Hi 3 13 0 20 140M C2E C16 1ODC23 150<br />

22B D012N104 5 5 7 5 12 0 342 528 11 8 14 2 25 140M D8E C20 IODC23 160<br />

22B D017Nl04 7 5 10 0 17 0 342 528 16 8 184 30 140M D8E C20 100C23 200<br />

22B D024N104 11 0 15 0 24 0 342 52e 23 4 26 0 50 140M F8E C32 100C43 285<br />

Ingresso trifase da 460 600 V c a 10 Uscita trifase da 0 575 V<br />

22B E1P7N104 0 75 1 0 1 7 414660 2 1 2 3 6 140M C2E B25 100C09 40<br />

22B E3PON104 1 5 2 0 3 0 414 660 3 65 3 8 6 140M C2E B40 100C09 60<br />

22B E4P2Nl04 2 2 3 0 4 2 414 660 5 2 5 3 10 140M C2E B63 100C09 90<br />

22B E6P6Nl04 4 0 5 0 6 6 414 660 8 1 8 3 15 140M C2E C10 100C09 150<br />

22B E9P9N 104 5 5 7 5 9 9 414 660 12 1 11 2 20 140M C2E C16 100 C16 160<br />

22B E012N104 7 5 10 0 12 2 414 660 14 9 137 25 140M C2E C16 1ODC23 200<br />

22B E019Nl04 11 0 15 0 19 0 414 660 23 1 24 1 40 140M D8E C25 100C30 285<br />

IP20 aperto<br />

Wan<br />

1 80no inoltre disponibili inverter monofase da 200 240 V c a con filtro EMC integrale II suffisso del catalogo<br />

cambia da Nl04 a N114<br />

2 Consultare la Guida alia selez one delle protezioni motore 140M pubblicazione 140M<br />

telaio e lacapaciti di frenatura riChiesti per<br />

8GOO1 perdeterminare il<br />

I applicazione in questione


Italiano 4<br />

Uscl aprogrammablla rale modulo CJ<br />

Valora nomlnala resislivo 3 0 A e30 V CC 3 0 A a 125 V CA 3 0 A e240 V CA<br />

Valore nominale Indutllvo 0 5 A a 30 V CC 0 5 A a 125 V CA 0 5 A e240 V CA<br />

Fusibili ed inlerruUori aulomatici<br />

Tlpo di luslbile consigliato clesse UL J CC T 0Tipo BSBB 600 V 550 VI 0equivalenle<br />

fnte uttori automatici consigliBt lnlerruttoriautomatici HMCP 0 equivalenti<br />

Funzioni di protezione<br />

@Ul508C c@CSA22 C<br />

EMC Direct 89<br />

LV EN 5017e EN 60204<br />

EMC EN 61e1JO3 EN 50081 1 EN 50082 2<br />

Usclta oNicha<br />

30 V CC 50 mA<br />

Non induttive<br />

Protezione motore protezione da sovracearlco 121 150 per 60 secondi 200 per 3 secondi fom aprolezlona dl Classa 10<br />

Sovraoorrenta 200 del limite hardware 300 del guaslo istantaneo<br />

Usclta analoglche 10bll<br />

0 10 V 1 k ohm m nlmo<br />

4 20 mA 525 ohm max<br />

Sovmtensione ingressoda 100120 V CA Lo seatlo sl verifiea ad una lensione bus di 405V CC<br />

lequivalenle ad una lineadi Ingresso<br />

Ingresso da 150 V<br />

da 200240 V CA La 5Oatlo si verifica ad una tenslone bus di 405 V CC equ alente ed una linea di Ingresso<br />

Ingrasso da 290V CA<br />

da 380460 V CA La seatlo sl verifiea ed una tenslone bus di 810 V CC equivalentead una linea di Ingresso da 575V CA<br />

Ingresso da 460600 V CA La seatlo sl verifiea ad una lensionebus di 1005V CC equivalente ed una linea di ingressoda 711 V CA<br />

Sono ensione ngresso da 100 20 V CA Lo seatlo si verifiea ad una lensionebus dl210V CC equivalenla ad una lineadl Ingresso da 75 V CA<br />

Ingresso da 200 240V CA Loscatlo sl verificaad una lensione bus di 210 V CC<br />

lequivalenle ad una linea di Ingresso<br />

Ingresso da 150 V CA<br />

da 380480 V CA Loscatlo sl verifieaad una lensione bus di 390 V CC equivalenle ad una linea dl Ingresso da 275V CA<br />

Ingresso de 460 600V CA Sa 10 seatloP042 3 alia lensione si verifiea ed una tensiona bus de 487 V CC linea ell Ingresso de 344 V CA<br />

Sa 10 scatlo P042 2 bassalensiolle si vemad una lenslonebus de 390 VCC Inea ell Ingresso de275 V CA<br />

Superamento conlrollo I superamenlo minimo II di 0 5 second iI valore liplco II di 2 secondi<br />

Superamento corrente senza guasti 100 millisecondi<br />

Freno dinamico<br />

IGBT con Ireno ntemo in dotazione con lutle Ie laglie Consullare I Appendice B del Manuata per tutente PowerFlex 40conlenulo sui CD per<br />

lnlormazloni su come ordinare<br />

CAl


Cablaggio di alimentazione<br />

Filo di alimentazione nominaIe<br />

Non schermato da 600 V 75 C 167 F THHNfTHWN<br />

Consigliato filo in rail1e<br />

Italiano S<br />

Isolato da 15 millisecondi per<br />

ambienti asciutli<br />

Anixter OLF 7xxxxx<br />

RHH RHW 2 schermato da 600 V 75 C 0 90 C 167 F 0 194 F Belden 29501 29507 0<br />

equlvalente<br />

Anixter 7V 7tXxx 3G<br />

Schermato da 600 V 75 C 0 90 C 167 F 0194 F AHH RHW 2 Shawflex 2ACD 3ACD 0<br />

equivalente<br />

Morsettiera di alimentazione<br />

Terminale 1<br />

Descrizione<br />

R1L 1 S L2 Ingresso monofase<br />

R1L 1 S L2 T L3 I ngresso trifase<br />

UfT1 A UfT1 motore<br />

UicD<br />

Scambiare due condutlori<br />

VfT2 A VfT2 motore del m6tore perinvertire la<br />

direzione di marcia<br />

WfT3 A WfT3 motore<br />

P2 P1<br />

Collegamento indutlori bus CC solo inverter con telaioC<br />

L inverter con telaio C viene spedito con un ponticello tra i terminali<br />

P2 e Pl Togliere iI ponticello solo se viene collegato un induttore<br />

bus CC L inverter non si accencfe senza in ponticello 0 un<br />

indutlore collegato<br />

DCt DC Collegamento bus CC<br />

BRt BR Collegamento resistore freno dinamico<br />

@ Terra di sicurezza PE<br />

1<br />

Importante i terminali a vite potrebbero allentarsi durante la spedizione Accertarsi che tutti i<br />

terminali siano serrati secondo i valori di coppia consigliato prima di accendere I inverter<br />

Specifiche della morsettiera di alimentazione<br />

Telaio Misura massima fili 2<br />

Misura minima fili 2<br />

B 5 3 mm2 10 AWG 1 3 mm2 16 AWG<br />

C 8 4 mm2 8 AWG 1 3 mm2 16 AWG<br />

Coppia<br />

2 Le misure massima e minima accetlate dalla morsetliera Obbligatorie<br />

1 7 2 2 N m 16 19<br />

Iibbre pollici<br />

2 9 3 7 N m 26 33<br />

libbre pollici


Italiano 6<br />

Condizioni potenza in ingresso<br />

Condizloni potenza in ingresso<br />

Soluzione<br />

Impedenza di linea bassa inferiore aIII della reattanza Installare un reattore di linea 1<br />

di linea o trasformatore di isolamento<br />

Trasformatore di alimentazione superiore a 120 kVA<br />

o induttore bus Solo inverter da<br />

5 5 11 kW 7 5 15 HP<br />

La linea dispone di condensatori di correzione del fattore Installare un reattore di linea<br />

di potenza o trasformatore di isolamento<br />

La linea subisce frequenti interruzioni<br />

La linea subisce picchi di rumore intermittenli superiori a<br />

6000 V fulmini<br />

La tensione da lase a massa supera il125 della tensione Togliere il ponticello MOV a massa<br />

regolare da linea a tensione Installare il trasformatore di<br />

Sistema di distribuzione senza messa a terra<br />

isolamento con messa a terra<br />

secondaria se necessario<br />

Configurazione delta aperta da 240 V Installare un reattore di linea<br />

1 Consultare l Appendice B del Manuale per I utente PowerFlex 40contenuto sui CD per informazioni<br />

su come ordinare accessori<br />

Consigli sui cablaggio<br />

110 2<br />

Tipo di filo Descrizlone Isolamento mlnimo<br />

nomina Ie<br />

Belden 8760 9460<br />

0 equivalente<br />

0 8<br />

100<br />

mm2 18AWG coppia intrecciata schermatoal<br />

con drenaggio 300 V<br />

60 C<br />

Belden 8770 0 8 mm2 18AWG 3 conduttori schermato solo 140 F<br />

0 equivalente per potenziometro remoto<br />

2 Se i fili sono corti e rientrano in unacustodia priva di circuiti sensibili potrebbe non essere<br />

necessario usare un ilo schermato tuttavia sempre consigliato<br />

Specifiche della morsettiera 110<br />

Telalo Misura massima fili 3<br />

Misura minima liIi 3<br />

BeC 1 3 mm2 16 AWG 0 13 mm2 26 AWG<br />

3<br />

Le misure massima e minima accettate dalla morsettiera Obbligatorie<br />

Coppla<br />

0 5 0 8 N m 4 4 7<br />

libbre pollici<br />

Consultare jJ Manuale per lutellte powerFlex 40 contenuto suI CD per<br />

infonnazioni sulla lunghezza consigliata per i cavi di alimentazione e controllo


Rele normalmente eperto<br />

Morsettiera di controllo<br />

Schema del cablaggiodi controllo<br />

Comune rele<br />

Rele normalmente chiuso<br />

1<br />

2<br />

Resistivo<br />

Induttivo<br />

Abilitazione ponticello 4<br />

Rt<br />

R2<br />

R3<br />

1<br />

I c<br />

i<br />

i<br />

1<br />

I<br />

30VCC<br />

SOmA<br />

oni ivo<br />

Importante la morsettiera 110 01 a sempre impostata<br />

sullarresto per inerzia ad eccezione di quando il<br />

parametro P036 Fonte avvio a imposlalo sui controllo a<br />

tre fill Nel controllo a Ire fili ia morsettiera 110 01 viene<br />

controllata dal parametro P037 Modo arresto Tutte Ie<br />

altre fonti di arresto vengono controllate dal parametro<br />

P037 Modo arresto<br />

1<br />

24V<br />

10 i<br />

05<br />

06<br />

07<br />

08<br />

09<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

Cablegglo<br />

Arresto 1 SRC tlplco<br />

W<br />

Awio marcia avanti 2<br />

Direzione relromarcia<br />

Comune digitale<br />

Ingresso digitele 1<br />

Ingresso digitele 2<br />

Ingresso digitale 3<br />

Ingresso digitale 4<br />

Comune otlica<br />

24V CC<br />

10VCC<br />

Ingresso da 010 V<br />

0 10V<br />

Comune analogico<br />

Ingresso da 4 20 mA<br />

Useita analogica<br />

Useita otlica 1<br />

Useita otlica 2<br />

Schermo RS48S OSI<br />

I<br />

I I<br />

I<br />

I<br />

Italiano 7<br />

Importante I inverter viene spedilo con un ponticello installato tra Ie morsettiere 110 01 ell Togliere questo<br />

ponticello se si utilizza la morsettiera 110 01 come ingresso di arresto 0 di abilitazione<br />

La figura riporta il controllo a due fill Per il conlrollo a tre ili usare un in9resso temporaneo sulla morsettiera<br />

1002 per coman dare un arresto Usare un ingresso mantenuto 0 perla morsettiera 110 03 per cambiare<br />

direzione<br />

3 Se si usa un uscita ottica con un carico induttivo quale un rela installare un diodo di recupero parallelo al rela<br />

come mostrato in figura per impedire danni all uscita<br />

P036 Feme avvIe Arresto Morsettfera va 01 arresto<br />

Taslierino numerico PerP037 Inerzia<br />

3fi1i Per Pa3 PerP037<br />

2fiH PerP037 lnerzia<br />

Porta RS4e5 PerP037 Inerzia<br />

4 Con il ponticello ENBL rimosso il terminale 110 1 agisce sempre da abilitazione hardware causando un arresto<br />

per Inerzia Per ulterlori informazioni in merito consultare II Manuale per I utenle PowerFlex 40 sui CD<br />

3


Italiano S<br />

Designazione del terminali I O di controllo<br />

N Segnale 01 fabbrica Oescrizione Paramo<br />

Rl Rels normalmente Guasto Contatto normelmente aperto per il rels di uscita A055<br />

aperto<br />

R2 Comune rels Comune per il rels di uscita<br />

R3 Rels normalmente Guasto Contatto normalmente chiuso per iI chiuso<br />

rele di uscita A055<br />

Selezione uscita analogica<br />

Interruttore DIP<br />

0 10 V<br />

Interrutlore all Source SRC<br />

di sinksource<br />

01 Arresto l<br />

Imposta I uscita analogica su tensione 0 corrente L impostalione deve<br />

cornspondere a A065 Seuscita anlg<br />

Gli ingressi possono essere cablati come sink SNK 0 source SRC impostando<br />

I interruttore DIP<br />

Inerzia Per poter awiare i inverter devono essere presenti iI ponticello 1 036 1<br />

installato in fabbrica 0 un ingresso normalmente chiuso<br />

02 Awiolmarcia avanti Non attivo II comando proviene automaticamentedal tastierino integraie P036 P037<br />

03 Direzione retromarcia Non attivo<br />

Per disattivare il funzionamento in retromarcia vedere II<br />

parametro A095 Oisab inversione<br />

04 Comune digitale Per in9resso digitale Isolato elettronicamente con ingressi<br />

digitali dalle uscite 1 0 analogiche e ottiche<br />

05 Ingresso digitale 1 Freq predel Pr09rammare con A051 Sel ingr digit 11 A051<br />

06 Ingresso digltale 2 Freq predel Program marecon A0521Sel ingr digit 21 A052<br />

07 Ingresso digitale3 Locale Pr09rammare con A053 Sel ingr digit 3 A053<br />

08 Ingresso digitale4 Jog avanti Programmare con A054 Sel ingr digit 4 A054<br />

09 Comune ottica Per uscire ad accoppiamento ottico Isolato elettronicamente con<br />

uscite ottiche da ingressi I O anelogici edigitali<br />

11 24 V CC Riferimento ecomunedlgitale<br />

Alimentazione fornita dall inverter per ingressi digitali<br />

Le corrente in uscita massima s 100 mA<br />

12 10 V CC Riferimento ecomuneanalogico P038<br />

2<br />

13 ingresso da 10 V<br />

Corrente tornlla dallinverter per unpotenziometro esterno<br />

da 0 10 V<br />

La corrente in uscita massima e 15 mA<br />

1 036 1 037<br />

A095<br />

Non attivo Per alimenlazione ingressoesterno da 0 10 V unipolare 0 1 038<br />

da 10 V bipolare impedenza in9resso lOOk ohm 0 A051 A054<br />

eccentrico del potenziometro<br />

A123 Al32<br />

14 Comune analogico Per ingresso da 0 10 V0 4 20 mA Isolato elettronicamente con<br />

ingressi ed uscite analogici da uscite 1 0 digitali eottiche 15 Ingresso da 4 20mA 12 Non attivo Per alimentazione in ingresso esternada 4 20 mA 1 038<br />

impedenza ingresso 250 ohm A051 A054<br />

16 Uscita anal09ica Freq uscita 0 10 L uscita analogica predefinlta s 010 V Per passare ad un A065 A066<br />

valore di corrente cambiare I interruttore all di selezione<br />

uscite anal09iche su 0 20 mA Programmare con A065<br />

Seuscita anlg 11 valore anal09ico massimo pub essere<br />

scalato conA066 iUscila anlg alia<br />

Canco massimo 4 20 mA 525 ohm 10 5 V<br />

0 10V lkohm 10mA<br />

17 Uscita ottica 1 Motore in funzione Progremmare con A058 Sel usc ottica 11 A058 A059<br />

18 Uscita ottica 2 A frequenza Programmare conA061 iSel usc ottica 21 A061 A062<br />

I 19 Schermo RS485 OSI Se si utilizza la porta di comunicazione RS485 OS la<br />

morsettlera deve essere collegata alia massedi sicurezza pE<br />

1 Vedere Ie nota a pie 1 e 4 a pagina 7<br />

2 Gli ingressi da 0 10 V e 4 20 mA sono canali di ingresso separati e potrebbero essere collegati simultaneamente<br />

Gli ingressi possono essere usati indipendentemente per II controllo velocitil oppure insleme in modalitil PID<br />

A132<br />

A064<br />

A064


Preparazione dell inverter per I avviamento<br />

Italiano g<br />

ATTENZIONE per poter eseguire Ie procedure di avviamento che seguono<br />

occorre alimentare I inverter Alcune delle tensioni presenti neIl inverter<br />

raggiungono il potenziale della linea di ingresso Onde evitare il pericolo di<br />

folgorazione 0 danni alleapparecchiature la procedura che segue va fatta<br />

eseguire escIusivamente da personale di servizio qualificato Prima di<br />

cominciare leggere e comprendere bene la istruzioni Se durante questa<br />

procedura uno degli eventi non si verifica Non continuare Eliminare tutta<br />

l alimentazione incIuse Ie tensioni di controllo Anche nel caso in cui non si<br />

alimenti Iinverter potrebbero tuttavia esistere tensioni fomitedall utente Prima<br />

di continuare eliminare il problema<br />

Prima di alimentare I inverter<br />

o 1 Accertarsi che tutti gli altri ingressi opzionali siano collegati ai tenninali<br />

giusti e siano sicuri<br />

D 2 Controllare che I alimentazionedi linea c a in prossimita del dispositivo di<br />

scollegamento rientri nei valori nominali dell inverter<br />

o 3 Con troll are che una deIle alimentazioni di controIlo digitale sia di 24 volt<br />

o 4 ControIlare che I interruttore DIP di sink SNK source SRC sia impostato<br />

in modo da corrispondere alproprio schema di cablaggio di controllo Vedere<br />

pagina 7per I ubicazione<br />

Importante 10 schema di controllopredefinito e SRC La morsettiera di arresto<br />

e coIlegata tramite ponticello tenninali 1001 ell per consentire<br />

l avviamento dal tastierino Se 10 schema di controllo viene<br />

cambiato in sink SNK il va ponticello rimosso dalle morsettiere<br />

1001 e 11 ed instaIlato traIe morsettiere 1001 e 04<br />

D 5 Controllare che I ingresso di arresto sia presente altrimentilinverter non<br />

si avvia<br />

Importante se la morsettiera 10 01 vieneusatacome ingresso di arresto<br />

Alimentare I inverter<br />

occorre rimuovere il ponticeIlo traIe morsettiere 1001 e II<br />

o 6 Inviare all inverteralimentazione ca e tensioni di controllo<br />

D 7 Prendere dimestichezza con Ie funzioni deltastierino integrale vedere pagina<br />

successiva prima di impostare i parametri del gruppo Programma<br />

Controllo avvio arresto direzione e velocita<br />

I valori dei parametri predefiniti consentonoil controllo deIl inverter dal<br />

tastierino integrale Non occorre alcuna programmazione per avviare arrestare<br />

cambiare direzione e controllare ladirezione direttamente dal tastierino integrate<br />

Importante per disattivare il funzionamento in retromarcia vedere il parametro<br />

A095 Disab inversione<br />

Se all accensione viene rilevato un guasto vedere pagina 17 una per spiegazione<br />

del codice di guasto Per informazionidettagliate sull individuazione dei<br />

problemi consultare il Manuale per l utente PowerFlex 40 contenuto sui CD in<br />

dotazione all inverter


Italiano 10<br />

o<br />

RUN<br />

Tastierino integrale<br />

PROGRAM<br />

@<br />

pnJLJ<br />

00 00<br />

@w@8<br />

00<br />

10<br />

CD QJ 10<br />

N LED Stato spia LED Descrizione<br />

Menu Descrlzlone<br />

d<br />

p<br />

R<br />

F<br />

Gruppo VlsuaUzzazlone solo vlsueUmzlona<br />

Include condizioni operetive dell inverter visualimle<br />

comunemente<br />

Gruppo Programma dl base<br />

Include Ie funzioni programmabi1i usate con maggiore<br />

frequenza<br />

Gruppo Programma avanzato<br />

Include Ie restanti funzioniprogrammabili<br />

Deslgnatora guasto<br />

Include un etenoo di codid per oondi onl di guasto<br />

spedtiche Visualizzalo solo In caso di guaslo<br />

0 Stato marcia Rossa sempre Indica che I inverter e in funzione con direzione di marcia comandata<br />

direzione accesa<br />

Lampeggia di inverter ha ricevuto iI comando di cambiare direzione di marcia<br />

rosso Indica la direzione effetliva del motore decelerando per arrivare<br />

a zero<br />

@ Display Rossa sempre Indica il numero di parametro il valore del parametro 0 il cod ice<br />

alfanumerico accesa di guasto<br />

Lampeggia di Una cifra sin ola lampeggiante indica che pub essere cambiata<br />

rosso Tutle Ie cifre ampegglanti indicano una condizione di guasto<br />

@ Units visualizzate Rossa sempre Indica Ie units del valore del parametro visualizzalo<br />

accesa<br />

0 Stato programma Rossa sempre Indica che il valore del parametro pub essere cambiato<br />

accesa<br />

0 Stato gusto Lampeggia di Indica un guasto all inverter<br />

rosso<br />

0 Stato potenziometro Verde sempre Indica che il potenziometro sui tastierino integrale e attivo<br />

accesa<br />

0 Stato lasto diawio Verde sempre indica che iI tasto diawio sui tastierino integrale e attivo<br />

accesa Anche il tasto di retromarcia e attivo a meno che non disabilitato dal<br />

parametro A095 Disab inversione<br />

N Tasto Nome Descrizlone<br />

0 Escape Indietro di una fase nel menu di programmazione<br />

Annullare la modi ica apportata ad un valore del parametro ed uscire<br />

dalla modalils Programma<br />

0<br />

@ Selezione Avanti di una fase nel menu di programmazione<br />

Selezionare una cifra durante la visualizzazione del valore del<br />

parametro<br />

W@ Freccia in su Scorrere lungo i gruppi ed i parametri<br />

Freccia in giu Aumentare ridurre il valore diuna cifra lampeggiante<br />

3 Enter Invio Avanti diuna fase nel menu di programmazione<br />

Salvare la modifica apportata ad un valore del parametro<br />

0 Potenziometro Usato per controllare ia velocits dellinverter Automaticamente atlivo<br />

Controllato dal parametro P038<br />

CD Awio Usato I per awiare inverter Automaticamente atlivo<br />

Controllato dal parametro P036<br />

CQJ<br />

Indietro Usato per invertire la marcia dell inverter Automaticamente attivo<br />

Controllato dai parametri P036 e A095<br />

Arresto Usato per arrestare I inverter 0 azzerare un guasto<br />

Questo tasto e sempre atlivo<br />

Controllato dal parametro P037


Fase<br />

Italiano 11<br />

Visualizzazione e modifica dei parametri<br />

ultimo parametro del gruppo Visualizzazione selezionato dall utente viene salvato prima di togliere ia<br />

corrente e viene visualizzato automatlcamente al rinvio di corrente<br />

Segue un esempio delle funzioni di base del tastierino integrale e di visualizzazione Questo esempio<br />

contiene istruzioni di base per la navigazione ed iIIustra come program mare il primo parametro del<br />

gruppo Programma<br />

I AI rinviodi corrente il numero dell ultimo<br />

parametro del gruppo Visualizzazione<br />

selezionato dall utente viene visualizzato<br />

brevemente con caratteri lampeggianti II display<br />

passa quindi automaticamente al valore corrente<br />

del parametro gli esempi riportano un valore<br />

dOOI Freq uscitaj con I inverter fermo<br />

2 Premere Esc unavolta pervisualizzare il numero<br />

del parametro del gruppo Visualizzazione<br />

all accensione II numero del parametro<br />

lampeggia<br />

3 Premere nuovamente Esc per passare al menu<br />

dei gruppi La lettera del menu lampeggia<br />

4 Premere la freccia versoIalto 0 verso il basso<br />

per scorrere lungo il menu dei gruppi d PeA<br />

5 Premere Invio 0 Sel per passare ad un gruppo<br />

La cifra a destra dell ultimo parametro<br />

visualizzato in que I gruppo lampeggia<br />

6 Premere Ie frecce verso Ialto 0 verso II basso<br />

per scorrere lungo i parametri contenuti nel<br />

gruppo<br />

7 Premere Invio per visualizzare II valore di un<br />

parametro Se nonsi intende modificare il valore<br />

premere Esc per tornare al numero di parametro<br />

8 Premere Invio 0 Sel per passare alia modalitil<br />

Programma e modificare il valore del parametro<br />

Se il parametro pub essere modificato la cifra a<br />

destra lampeggia e la spia LED Programma si<br />

accende<br />

9 Premere Ie frecce verso Ialto 0 verso il basso<br />

per cambiare il valore del parametro Se 10 si<br />

desidera premere Set per spostarsi da una cifra<br />

all altra 0 da un bit all altro La cifra 0 il bit<br />

modificabili lampeggiano<br />

10 Premere Esc per annullare la modifica<br />

apportata La cifra non lampeggia piu II valore<br />

precedente viene ripristinato e la spia LED<br />

Programma si spegne<br />

Oppure<br />

Premere Invio per salvare la modifica apportata<br />

La cifra non lampeggia piu e la spia LED<br />

Programma si spegne<br />

11 Premere Esc per tornare all elenco dei<br />

parametri Continuare a pre mere Ese per<br />

uscire dal menu dl programniazione<br />

Se premendo Esc il display non cambia si<br />

visualizza il parametro dOOl Freq uscita<br />

Premere invlo 0 Sel per passare al menu dei<br />

gruppi<br />

Tasti Esempi di display<br />

VOLTS n<br />

LI Unlo<br />

PROGRAM FAULT<br />

o 0<br />

d 0 0 A ri<br />

PROGRAM FAULT<br />

o 0<br />

d00<br />

J oppure PROGRAM FAULT<br />

o 0<br />

@ oppure @ P 0 3 ml<br />

rt fD<br />

oppure<br />

C3 oppure @<br />

C3 oppure @<br />

CfJ oppure<br />

C3<br />

PROGRAM FAULT<br />

0 0<br />

2<br />

PROGRAM FAULT<br />

o 0<br />

1<br />

1<br />

0 VOLTS<br />

0 AMPS<br />

o HERTZ<br />

J n VOLTS<br />

U<br />

23 H h<br />

PROGRAM FAULT<br />

0<br />

2 2 Unl<br />

PROGRAM FAULT<br />

o 0<br />

VOLTS<br />

P 0 3 ri<br />

PROGRAM FAULT<br />

o 0


Italiano 12 Per ullenori informazloni sui parameln consullare iI manuale dell uienle PowerAex 40 contenulo sui CO<br />

Parametri del gruppo Visualizzazione<br />

N Parametro MinIMex DisptaylOptlonl<br />

dOOI Freq uscila O OI Frequenza maxi 0 1 Hz<br />

d002 Freq comandela O OI Frequenza maxi 0 1 Hz<br />

d003 Corr in useila O OOIAmpere inverler x 2 0 01 Amp<br />

d004 Tens in uscilel orrens nom Inverter 1 VCA<br />

dooS Tens bus CC In base all inverter nomlnale I VCC<br />

d006 Slato unlta 0 1 1 Condizlone vera IliU llit2 lliU llit ll<br />

Decelerazione Accelerazione Marcia avantl In esecuzlone<br />

d007 Ccxllce guaslo xl F2F122 Fl<br />

d009<br />

dOlO Display di proc 0 00 9999 0 01 1<br />

d012 Fonle controlloj 019 Bit 1 Riferimenlo dells velocila Bit 0 Comando di awio<br />

Vedere P036 9 Freg jog Vedere P036 9 Jog<br />

d013 Slalo ingr conlr 011 1 Presente Ingresso IliU llit2 lliU llit ll<br />

Trens DB an Arresto ingresso OirlRetromarcia lng awiolavanti<br />

d014 Slalo ingr di91 011 1 Presente ingresso IliU llit2 lliU llit ll<br />

Ingrdigil4 Ingrdlgll3 Ingrdigll2 Ingrdlglt 1<br />

j d01S Slalo comun 011 1 Condlzlone vera IliU llit2 lliU llit ll<br />

Errore comunicazione Opzione DSI Transmissione Ricevimento<br />

d016 Vers software 1 00199 99 0 01<br />

d017 Tipo Inverterl 100119999 1<br />

d01S Tempo avvio scad 019999 ore 1 lOore<br />

d019 Dati tes pOlnl OIFFFF 1 esag<br />

d020 Ingr anlg 0 10 V 01100 0 0 1<br />

d021 Ingr an 4 20 mAj 0 01100 0 0 1<br />

d022 Potenza usella O OOI Allmenlezlone Invener x 2 0 01 kW<br />

d023 <strong>Fan</strong> pol uscile 0 01180 0 deg 0 1 deg<br />

d024 Temp inverter 01120 C I C<br />

d02S Slelo conlegglol 019999 1<br />

d026 Slalo timer 0 019999 0 1 See<br />

d02e Slato logica STP 017 1<br />

d029 Corr di coppia O OOI Ampere Inverter x 2 0 01 Amp<br />

Avviamento facilitato con i parametri di base del<br />

gruppo Programma<br />

inverter PowerFlex 40 e concepito per un awiamento semplice ed efficiente II gruppo Programma<br />

contiene i parametri usati con maggiore frequenza<br />

QJ Prlma di camblarequesto paramelro arrestare inverter<br />

N Parametro IMlnlMax DisplaylOpzlonl Ollabbrica<br />

P031 Tens Terga mot 120fTens nom Inverter I VCA In base allinverter nomlnale<br />

QJ Impostsre sulla tensione nominale riportata sulla larga del<br />

molore<br />

P032 Freq nom mot 151400 Hz I Hz 60Hz<br />

QJ Impostsre suUa frequenza nominate riportata sulla targa del<br />

motora<br />

P033 Carr sovracc mot<br />

Ir O Ampere nomineli 0 1 Inverter x 2<br />

Amp In baSEl al1 inverter nomlnale<br />

Impastato sulls correntemotore massima consentita<br />

PO 4 Freq minima 10 01400 0 Hz 0 1 Hz 0 0 Hz<br />

f<br />

ello minlmo di frequenza generatodi continuo<br />

P03S Frequenza maxi 101400 Hz I Hz 60Hz<br />

QJ<br />

f<br />

ello massimo di frequenza generato<br />

P036 Fonle awlol 1016 0 Teslierlno l<br />

QJ<br />

Imposta<br />

1 A3fili<br />

10 schema di oontrollo I<br />

1<br />

usalo per awiare inverter<br />

2 A2fi1F<br />

Seettlvo encl1e II taslo di retromarcla e attlvo a meno<br />

3<br />

4<br />

Sens liv a2 fill<br />

Alta vel e2 tilF<br />

che non disabililato dal paramelro A095 Disab 5 Porta comune<br />

Inverslonej 6 AvanMnd temp<br />

0


Per ullerion info rmazioni sui parametri consultare iI manuale del1 utenlePowerF1ex 40 contenuto suI CD Italiano 13<br />

QJ Prima di cambiare questo parametro arrestare I inverter<br />

N Parametro IMinIMax Display Opzloni 01 fabbrlca<br />

P037 Modo arrestoj 1019 0 Rampa CPl 1 nertia Cp l<br />

Attivare it modo arresto per tutte Ie fonti di arresto ad<br />

2 FrenoCC Cp ll<br />

1 esempio tastierino marcia avanti morsettiera 0 02<br />

3 FrenoCC autom CP 1<br />

r tromareia morsettiera 110 03 porta RS485 ad eocezlone 4<br />

di quanta<br />

Rampa<br />

annotato di seguito 5 Inerzia<br />

Importante la morsettlera 110 01 e sempre imposlata 6 FrenoCC<br />

sull arresto per inerzla ad eccezione di quando iI parametro 7<br />

P036 Fonte awio e impastato sui controllo atre fill Nel<br />

6<br />

controllo atre fili la<br />

F eno CC autom<br />

Rampa EM B CP<br />

morsettiera 110 01 viene controllata dal 1<br />

9<br />

o paramet P037 Modo arresto<br />

Rampa EM Freno<br />

L ingresso di arresto azzera inoltre i1 guasto<br />

attivo<br />

P036 Rilvelocitll 1017 o<br />

1<br />

Potenziom inverter<br />

Freq<br />

0<br />

interna<br />

Imposta la sorgente del riferimento velocitaal1 inverter<br />

2<br />

Importante quando<br />

Ingresso da0 1 0 V<br />

il parametro Sel Ingrdigit x A051 0 3 ngresso da 4 20 mA<br />

A052 e impostatosull opzione 2 4 5 6 13 0 14 el ingressO 4<br />

digitale e attivo A051 A052 A0530A054 sovraserive II<br />

5<br />

Freq predel<br />

Porta comunen<br />

riferimento della velocita comandatoda questo parametro 6 Logica STP<br />

Consullare iI Capitolo 1 del Manuale per utente PowerFlex 7 Molt ingr an<br />

40 contenulo sui CDper ulleriori informazioni<br />

P039 Tempo aceel 1 10 0 600 0 See 0 1 See 10 0 See<br />

Imposta la frequenza dl accelerazione per tutti gli incrementi<br />

di velodtll<br />

P040 Tempo deeel 11 10 1 600 0 See 0 1 See tO OSec<br />

Imposta la frequenza di decelerazione per tutti i decrementi<br />

di velocitA<br />

P041 Reset adelaull o 1011 P ontolFermo 0<br />

QJ Ripristina tutti i parametri sui valori 1 Ripr valori di fabbrica<br />

predefinitidi fabbrica<br />

P042 Categ tensione 123 2 Bassa tens 4eO V<br />

QJ Imposta la classe di te sione per gli inverter da 600 V 3 Alia tens 600V<br />

Parametri del gruppo Avanzato<br />

N Parametro MinIMax Olsplay Opzloni 01 fabbrlca<br />

A051 Sel ingr digit 11 0 26 o Nen usato 13 Contr ing da 10 V 4<br />

Morsettiera I O 05 1 Ace edecel2 14 Contr ing da 20 mA<br />

A052 Sel ing digit 2 2 Jog 15 OlsabPIO 4<br />

Morseniera I O 06 3 Errore aus 16 MOP suo<br />

A053 el ing digit 3 4 t<br />

Freq predel 17 MOP giu 5<br />

orseniera I O 07 5 Locale 18 lnizie timer<br />

A054 el ingr digit 4J 6 Porta comune<br />

iO<br />

11<br />

QJ<br />

orselliera I O 08 7<br />

e<br />

9<br />

Azzera guasti<br />

Arresto rampa<br />

CP<br />

Arresto per tnerzia<br />

21 Reset conteggio<br />

CF 22 Reset timer econr<br />

10 Arrestoiniez CC CF 23 lng logl<br />

11 Jog avanti 24 lng log2<br />

12 Jog Indietro 25 Um corrente 2<br />

26 Inverter anal<br />

A055 Sel usdta releJ 0 22 0 Pronto Guaste 11 ngrlog 1 0<br />

1 A frequenza 12 ngr log 2<br />

2 Motore in marcia 13 Logica 1 e 2<br />

3 Indietro 14 Logica 1 02<br />

4 Sovrac met 15 Use logiea STP<br />

5 Regol rampa 16 Uscita timer<br />

6<br />

7<br />

aOltrela frequenza<br />

Oltre la 1 git<br />

o<br />

g<br />

corrente<br />

i 6 Oftre Volt CC 19 Perd ingr an<br />

9 Esaurite riprove 20 Cont param<br />

10 Olt e V analog 21 Guasto non recup<br />

22 Contr freno EM<br />

A056 Liv usena relel 0 019999 0 1 0 0<br />

A056 Sel use ottica 1 022 0 P on1oIGuasto 11 lng log 1 2<br />

A061 Sel use ottica 2 1 RA frequenza 12 lng log 2 1<br />

2 Motore in marcla 13 Logica 1 e 2<br />

3 Indietro 14 Logica 1 02<br />

4 Sovrac mot 15 Use logica STP<br />

I<br />

5 Regol rampa 16 Useita timer<br />

6 Oltre la equenza g ap o<br />

R<br />

7 eltrela corrente<br />

8 Oltre I VallCC 19 Perd ingr ana<br />

9 Esauriteriprove 20 Contrparamo<br />

10 Ollre V analog 21 Guasto non recupa<br />

22 Contr Irena EM<br />

0<br />

3


Italiano 14 Per u1teriori informazlonl sui parametri consultare II manuale dell utente PowerFlex 40 contenuto suI CD<br />

N Parametro MinIMax IOlsplay Opztonl Oi labbrlca<br />

A059<br />

11IV use onlca I<br />

A062 lIv use onica 2<br />

0 9999<br />

10<br />

Imposlazlone A055 A05e eA061 Velori A056 A059 e A062 minimax<br />

6 01400 Hz<br />

7 Ol1eO<br />

e 0le15Vall<br />

10 01100<br />

16 0 1 9999 See<br />

17 119999conteggi<br />

le ll1eOdeg<br />

20 0 1<br />

10<br />

1 0 0<br />

A064 Log use olllea To 3 11 0<br />

OpzioneA064 log uscita otlica 1 log uscita ottica 2<br />

0 NO normalmente sparta NO normalmente aparta<br />

1 NC normalmente chiuso NO normalmente sperte<br />

2 NO normamenle sperta NC normalmenle chiuso<br />

3 NC normalmenle chiuso NC normalmente chluso<br />

A065 Sel usclla enlg 10120 11 0<br />

Gamma Valoredi Valara dl uscita massimo Posizione<br />

Opzione useila uscllamlnlmo Usel aanlg elle inlerrulloreDIP<br />

o Freq usc 0 10 0 10 V OV OHz P035 IFrequenze maxi ol0V<br />

1 Corr usc 0 10 0 10V o V 0 ampere<br />

200 FLA nomlna llnverter O IOV<br />

2 Ul0Volt usc 0 10V OV OVolt 120 volt uscita nominateinverter ol0V<br />

3 Pot uscilaO l0 010V OV OkW 200 potenza nominale inverter ol0V<br />

4 TstDala 0 10 0 10V OV OOOO 65535 FFFF esedeclmeli ol0V<br />

5 Freq use 0 20 01 20mA OmA OH z P0351Frequenze maxi 01 20 mA<br />

6 Corr use 0 20 01 20mA o mA 0 ampere<br />

200 FLA nominate Inverter 01 20 mA<br />

7 0 20 Volt usc 01 20 mA OmA OVolt 120 vo uscltanomlnale Inverter 0 20 mA<br />

e Pot uselte 0 20 01 20mA OmA OkW 200 potenza nomlnale Inverter 01 20mA<br />

9 TstData 0 20 01 20 mA o mA 0000 65535 FFFF esedecimeli 01 20 mA<br />

10 Freq usc 4 20 41 20mA 4mA OHz P035 IFrequenze maxi 01 20 mA<br />

11 Corr use 4 20 41 20mA 4 mA 0 ampere<br />

200 FLA nominate Inverter 01 20mA<br />

12 420 Voll use 41 20mA 4mA OV t 120 volt uscila nomlnale inverter 01 20 mA<br />

13 Pol uscita 420 41 20mA 4mA OkW 200 polenza nomlnale inverter 0 20mA<br />

14TstData 4 20 1 20 mA 4 mA 0000 65535 FFFF esadoomall 01 20 mA<br />

15 CoppiaUsc 0 10 0 10V OV Oampere 200 FLA nomlnale inverter 0 10V<br />

16CoppiaUsc 020 01 20 mA o mA 0 ampere<br />

200 FlA nominale inverter 01 2OmA<br />

17 CoppiaUsc 4 20 4 20mA 4 mA 0 ampere 200 FLA nominale inverter 01 20 mA<br />

18 Prestab 1O 0 10V OV O 100 0 di imposlazione prestabi1ita 010 V<br />

19 Prestab 0 20 O 20mA OmA O 100 di fmposl8zione preSlabllila 0I 20mA<br />

20 Preslab 420 41 20mA 4mA OO 100 0 dllmposlezione preslabilita 0I 20mA<br />

A066 Useile anlg alia OleOO 1 100<br />

A067 Tempo aceel 21 0 0 6000 See 0 1 See 20 0 See<br />

A066 Tempo decel 2 0 1 6000 Sec 0 1 See 20 0 Sac<br />

A069 IFreq Inlerna 0 0 4000 Hz 0 1 Hz 60 0 Hz<br />

A070 O<br />

0 0 4000 Hz 0 1 Hz 0 0 Hz<br />

A071 Freq predel f1 A072<br />

A073<br />

Freq predel 2<br />

Freq pradel<br />

5 0 Hz<br />

10 0 Hz<br />

3 A074<br />

A075<br />

A076<br />

Freq predel 4<br />

Freq predel 5<br />

Freq predel<br />

20 0 Hz<br />

30 0 Hz<br />

40 0 Hz<br />

6 50 0 Hz<br />

A077 Freq predel 60 0 Hz<br />

11 Per anivare Freq predel OJ Impostare P038 RII volocllal sull opzlone 4<br />

Slatolngresso Slalolngresso Slato lngrasso Sorgenledella accelerazion<br />

MO it6 05 MO r it6 06 iMO r<br />

M07<br />

frequenza<br />

d ne usato 2l<br />

0 0 0 IFreq predel 01 Tempo accel 1 II Tempo decel 1 I<br />

1 0 0 IFreq predef lJ Tefl1jlo aceel 1 1 Tempo decel 11<br />

0 1 0 IFreq predef 21 Tempo accel 211Tempo decel 21<br />

1 1 0 IFreq predef 31 Tempo eccel 2 1 Tempo decel 21<br />

0 0 1 IFreq predel 41 Tempo eceel 111 Tempo decel 11<br />

1 0 1 IFreq predef 5 Tempo accel 1 IITempo decel 11<br />

0 1 1 Freq predef 6 Tempo aceeL2 I Tempo decel 21<br />

1 1 1 IFreq predal 7 Tempo accel 2J 1 Tempo decel 21<br />

2<br />

Quando un ingressodigitale viene Impastato su Aceel 2 e decel 2 e I ingressoelittivo quellingressosovrascrlve Ie<br />

Imposlazlonl contenute in questa labella<br />

A078 Frequenza jog 10 0 Frequenza maxi 10 1 Hz 10OHt


Per ulteriori informazionl sui parametri consultare i1 manuale dell utente PowerFlex 40 contenuto sui CD Italiano 15<br />

N Parametro I MinIMax Oisptay Opzionl 01 labbrica<br />

A079 IAcceVdaceV jog 10 1 600 0 See 0 1 See 10 0 See<br />

A080 Tempo freno CC 10 0 99 9 See 0 1 See 0 0 See<br />

Un impotazione di 99 9 sec Continua<br />

A081 liv freno CC O O Ampere inverter x 1 8 0 1 Amp Ampere x 0 05<br />

A082 Sel res freno d 0 99 o Disattivalo 2 Nessuna protezione 0<br />

QJ<br />

1 Risol RA normate 3 99 del cicio di servizlo<br />

A083 1<br />

Curva S 0100 1 0 disabilneto<br />

A084 ISelezione boost 014 Impostazioni in della tensione dl base 8<br />

Attivo solo quandoA 1251Mod prest coppia e imposlato 0 V1Hz person<br />

su 0 VlHz Coppia<br />

7 4 11 kW<br />

variabile Coppiacostante 5 15 HP<br />

1 30 0 IT 5 D O no IR 10 10 0 cr<br />

2 35 0 IT 6 0 0 11 12 5 Cr<br />

3 400 IT 7 2 5 cr 12 15 0 cr<br />

4 45 0 IT 8 5 0 cr 13 17 5 cr<br />

9 7 5 cr 14 20 0 cr<br />

A085 ISoosl in Awio 10 0 25 0 0 1 2 5<br />

Attivo solo quando A084ISetezione boosll eA 125 Mod prest coppial sono impostati su 0<br />

A086 Tensioneinterr j 10 0100 0 10 1 25 0<br />

Attivo solo quandoA084ISelezione boost eA125 Mod prest coppial sono impostati su 0<br />

A087 IFreq inlerrl 10 0 400 0 Hz 10<br />

Attivo solo quando A0841Selezione boosl eA1251Mod prest coppial sono impostali su 0<br />

1 Hz 15 0 Hz<br />

A088 Tensione massimal 20NoII nominali 1 VCA Tensione nomin<br />

A089 llimite corr 11 0 1 Ampere inverter x 1 8 0 1 Amp Ampere x 1 5<br />

A090 Sel sovr mot 0 2 o Nessun declassamento 1 Declassamento minimo 0<br />

2 Declassamento massimo<br />

A091 Frequenza PWM 2 0116 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Tenl riawio aul 0 9 1 0<br />

A093 IRit nawio aull 0 0 300 0 See 0 1 See 1 0 See<br />

A094 IAwio allaco 0 1 o Disattivalo 1 Abililalo 0<br />

QJ<br />

A095 IDisab inversione 0 1 o Abilitazione inversione 1 Disabilitazione inversione 0<br />

QJ<br />

A096 ISlartVolo abil l 0 1 o Disattivalo 1 Abililalo 0<br />

A097 ICompensazione 03 o Disaltivato 2 Meccanico 1<br />

1 Elettrico 3 Entrambi<br />

A098 IScatto COIT SW O O Ampere inverter x 2 0 1 Amp 0 0 Disabilitalo<br />

A099 Fattore di prccl 0 1999 9 0 1 30 0<br />

Al00 IAzzera guasll 0 2 o Pronlo Fermo 1 Resetguasto 0<br />

Q<br />

2 Azzera buffe<br />

Al01 ISlocco programmal 09999 0 Sbloccato 1 Sloccalo 0<br />

Al02 ISel leslpoinl 400 FFFF 1 esag 400<br />

Al03 IFreq dali comun 0 5 0 1200 3 9600 3<br />

Per rendereeffeltive Ie modifiche apportate occorre<br />

spegnere<br />

1 2400 4 19 2 K<br />

e j quindi riaccendere inverter<br />

2 4800 5 384 K<br />

Al04 lind nodo comun 1 247 1 100<br />

Per rendereeffeltive Ie modifiche occorre<br />

apportate<br />

spegnere e quindi riaccendere l inverter<br />

Al05 AzioneGuastiCom 03 o Guasto 2 Arresto 0<br />

1 Arresto per inerzia 3 Continua ultima velocitA<br />

Al06 Tempo perd comj 0 160 08ec 0 1 5 0<br />

l l Al07 Formatocomun 0 2 0 RTU 8 N 3 RTU 8 N 2 0<br />

Per rendere effettive Ie modifiche apportate occorre<br />

l<br />

spegnere<br />

1 RTU 8 E 4 RTU 8 E 2<br />

e I quindi riaccendere inverter<br />

2 RTU 8 0 1 5 RTU 8 0 2<br />

Al08 llingua 10 1 English 6 Riservato 1<br />

2 Francais 7 Portugues<br />

3 Espanor 8 Riservato<br />

4 Italiano 9 Riservato<br />

5 Deutsche 10 Olandese<br />

Al09 Presl use anall 0 0 100 0 0 1 0 0<br />

All0 Ing an 0 10 V bal 0 0 100 0 0 1 0 0<br />

QJ


Italiano 16<br />

Per ulleriori informazioni sui paramelri consultare H manu ale del1 utente PowerFlex 40 conlenuto sui CD<br />

N Parametro MInIMax Dlsplay Opzlonl DI fabbrlca<br />

Al11 Ing an 0 10 Vel 0 0 100 0 0 1 100<br />

Q<br />

A112 Ing an 4 20 mA b 0 01100 0 0 1 0 0<br />

Q<br />

A113 Ing an 4 20 mA a 0 01100 0 0 1 100<br />

Q<br />

A114 Freq corr a FLA 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

A115 Tempo proc<br />

A116 Tempo prce<br />

basso 0 00 99 99 0 01 0 00<br />

alto 0 00 99 99 0 01 0 00<br />

A117 Modo reg busl 0 1 0 Disattivato 1 Abilitato 1<br />

Al18 Umite corr 2 O l Ampera Inverter x 1 8 0 1 Amp Ampere x 1 5<br />

Al19 Frequenza saito 0 400 Hz 1 Hz OHz<br />

A120 Banda freq saMo 0 0130 0 Hz 0 1 Hz 0 0 Hz<br />

A121 Tempo mot stallo 0 5 o 60 secondF 3 360 seeond 0<br />

1 120 secondi 4 480 second<br />

2 240 secondi 5 Guas1o disatt<br />

A122 Perd ingr anal l 0 6 o Disattivato 4 Rif Ireq min 0<br />

1 Guasto F29 5 Ril Ireq max<br />

2 Arresto 6 Ril Ireq int<br />

3 Ril zero<br />

A123 IAbil bipoll 0 V 0 1 0 Ingr unipolare 1 Ingr rnpolare 0<br />

A124 Disab PWM varieb 011 0 Abllitato 1 Disattivato 0<br />

A125 Mod prest coppia 0 1 0 VHz 1 Veltora sensorless 1<br />

A126 FLA nom mot O l Ampere inverter x 2 0 1 Amp Corrente nom<br />

A127 Autotune 0 2 0 ProntolFermo 2 Rotaz sint 0<br />

1 Sint statics<br />

A128 Cad tensione IR 0 0230 0 V CA 0 1 VCA Tenslone nomin<br />

A129 Ritcorr f1uss O OO Tens Targa mot 0 01 Amp Corrente nom<br />

A130 Trim PID allo 0 0 400 0 0 1 60 0<br />

AI31 Trim PID basso 0 0 400 0 0 1 0 0<br />

A132 Sel rif PID 0 8 o Disab PID 5 Trim prestab 0<br />

1 PID prestab 6 Trim da0 10 V<br />

2 Ingresso da 0 1 0 V 7 Trim da4 20 mA<br />

3 Ingresso da 4 20 mA e Trim di comun<br />

4 Porta comune<br />

A133 Sel leedback PID 0 2 o Ingresso da 0 10 V 2 Porta comune 0<br />

1 Ingresso da 4 20 mA<br />

Al34 Guad prop PID 0 00 99 99 0Q1 0 01<br />

A135 Tempo integr PIDI 0 0 999 9 See 0 1 2 0<br />

A136 Tasso dill PID 0 00 99 99 l sec 0 01 0 00<br />

A137 PID prestab 0 0 100 0 0 1 0 0<br />

A13e PID banda mortal 0 0 10 0 0 1 0 0<br />

A139 PID precarlco 0 0 400 0 Hz 0 1 Hz 0 Hz<br />

A140 Loglca prestab 0 7 0001 bAFF 4cllre OOFl<br />

A147 Per un elanco delle opzioniper Ie cifre consultsre iI Manualeper utente PowerFlex 40 contenulo sui CD In dotazione all inverter<br />

A150 Tempo log presto7 0 0 999 9 See 1<br />

A157<br />

0 See 30 0 See<br />

A160 Rit Ireno EM dis 0 01 10 00 See 0 01 See 2 00 See<br />

A161 Rit Ireno EM attl 0 01110 00 See 0 01 See 2 00 See<br />

A162 Sel reset MOP 0 1 o Ril MOP zero 1 Sa a rtl MOP 1<br />

I


Codici guasto<br />

Italiano 17<br />

Per azzerare un guasto premere il tasto Arresto togliere e rinviare corrente 0<br />

impostare il parametro AlOO Azzera guastiJ su I 02<br />

N Guasto Oescrizione<br />

F2 Ingresso ausiliariol1l Controllare il cablaggio remoto<br />

F3 Perd potenza Manitorare la linea in CA in enlrata per rilevare una bassa tensione 0 un interruzione alia linea stessa<br />

F4 Sattatensionelll Monitorare la linea in CAin entra aper rilevare una bassa tensione 0 un interruzione ana linea stessa<br />

F5 Sopratensionell Manilorarela linea CA per rilevare condizioni di alia tensione di linea 0transitori La sovralensione bus p ub<br />

essere causata ancha dana rigenerazione del motora Eslendere II tempo di decelerazione 0 installare I optione<br />

di renatura dinamica<br />

F6 Motore in stallo Aumentare Tempo acc l xlo ridurre iI carico in modo che la corrente in uscita dell inverter non superi iI valera<br />

impostatodal parametroA089 Limite corr 11<br />

F7 Sovracc motore l<br />

F8 Sovratemp dissip ll1<br />

Condizione di carico motore eccessivo Ridurre iI carico in modo che la correnle in uscita dell inverler non superi<br />

la corrente impostata dal para metro P033 Corr sovracc mot<br />

Controllare che Ie aletle del dissipatore di calore non siano b10ccate 0 s orche Controllare che la temperatura<br />

ambiente non abbia superato i 40 C 104 F perconfigurazioni IP 30 EMA Tipo 1 0 50 C 122 F per<br />

configurazioni di tipo aperto<br />

Controllara la ventola<br />

F12 Sovrac hardware ControUare la programmazione Controllare che non si causi una corrente eccessiva a seguito di un carico<br />

eccessivo di un impostazione di boost CC non adeguata di volt di frenatura CC troppo alti 0 di aUre cause<br />

F13 Guasto terra Controllare iI cablaggio motore ed esterno ai terminali di uscila inverter per una condizione amassa<br />

l<br />

F29 Perdite ingressi analogici<br />

Un ingresso analogico e configurato per Un guasto alia perdita del segnale Si e verificata una perdita del<br />

segnale<br />

F33 Tent riavvio aut Correggara la causa del guasto 00 azzafare manualmente<br />

F36 Da fase U a terra Controllare iI cablaggio tra I inverter ed il motore Controllare il motore per rilevare una fasea massa<br />

l<br />

F39 Oa fase V a terra<br />

SosUtuire inverter qualora non fosse possibile azzerare II guasto<br />

F40 oa fase W aterra<br />

F41 Corloe fase VV Controllare it cablaggio motore edei terminali di uscita inverter I<br />

per rilevare un cortocircuito<br />

F42 Cortoc fase VW<br />

Sostituire inverter qualora rion fosse possibile azzerare it guasto<br />

F43 Cortoe fase VW<br />

i F48 Param a default L inverter riceve iI comando di scrivere valori predefinitisulla EEPROM Azzerare il I<br />

guasto 0 fermare e riavviare<br />

inverter Program mare i parametri dell inverter secondo necessita<br />

F63 Sovrae SW Controllare i requisiti di carico e I impostazione A098 Scatto carr SW<br />

F64 Sovracc inverter Ridurre il carico 0 aumentare il tempo di accelerazione<br />

F70 Vnila di pot Togliere e rinviare corrente Sostituire inverter qualora non fossepossibile azzerare il guaslo<br />

F71 Perdita rete La retedi comunicazione non funziona<br />

F60 Autotune SVC La funzione di autotune e stata annullata dall utente 0non e riuscita<br />

Fe1 Perdita comunicazioni<br />

F100 Checksum parametri Ripristinare i valori predefiniti<br />

t<br />

l<br />

t<br />

l<br />

I<br />

r r r s a a h i e g cee a<br />

e stata scollegata intenzionalmente Spegnere usando A105 Azione GuastiComj<br />

F122 Guasto schOOa 110 Togliere e rinviare corrente Sostituire I inverter qualora non fosse possibile azzerare il guaslo<br />

1<br />

Tentativo di reseVesecuzione fallito Configurare con i parametri A092 e A093<br />

I ol l<br />

E l<br />

da


Italiano 18<br />

Oimensioni inverter<br />

Telai PowerFlex 40 I valori nominali sana in kWe HP<br />

Telalo 120 V CA Monofase 240 V CA Monofasa 240 V CA Trlfase 480 VCA Trlfase 600 V CA Trlfase<br />

8 0 4 0 5 04 0 5 075 1 0 0 75 1 0<br />

04 0 5<br />

075 1 0<br />

2 0<br />

3<br />

0 4 0 5 2<br />

0 75 1 0 4 0 5 0<br />

7 5 0 0 75 1 0 4 0 5 0 1<br />

512 0<br />

1 1 1 5 1 5 2 0 1 5 2 0 1 5 2 0 2 2 3 0<br />

C 2 2 3 0 5 5<br />

7 517 5 10 0<br />

5 5<br />

7 517 5 100<br />

11 0 150 5 5<br />

7 5l7 5 10 0<br />

11 0 15 0<br />

rr AD 1j D<br />

D<br />

000 60<br />

0 OO<br />

Q<br />

I k 5 5 0 22<br />

Al<br />

m<br />

Inverter PowerFlex 40<br />

1 F<br />

U<br />

213<br />

213 0l<br />

Le dimensioni sono espresse in millimetri e pollici<br />

I pesi sono espressi in chilogrammi e iibbre<br />

0<br />

OJ<br />

Peso per Ie<br />

A B C 0 E F spedizlone<br />

8 100 180 136 87 168 e7 4 2 2<br />

3 94 7 09 5 35 343 6 61 3 44 4 9<br />

C 130 260 180 116 246 4 3<br />

5 1 10 2 7 1 4 57 9 7 9 5<br />

Kit per Ie opzioni di comunicazione filtro RFI IP 30INEMA 1UL Tipo 1<br />

m<br />

o O<br />

2<br />

0<br />

0<br />

c<br />

Inverter contnvertercon<br />

Opzlone feleloB telaioC<br />

A Copertura comune 25 0 9B 25 0 ge<br />

8 Flltro di linea EMC 50 1 97 60 2 36<br />

C Fiilro di linea EMC 229 9 02 309 12 17<br />

0 IP 30 NEMA lfTipo ULl 33 1 30 60 2 36<br />

IP30 NEMA lUL Tipo 1 64 2 52 60 2 36<br />

per la copertura comune<br />

B<br />

o<br />

Telalo B 22 JBCB<br />

usalo con la copertura comune<br />

Tetalo C 22 JBCC<br />

usalo con la copertura comune<br />

U S Allen Bradley Drives Technlca Support<br />

Tel 1 262512 8176 Fax 1 262 5122222 Emaii support@drives ra rockwell com Onllno wwwob oomlsupportlabdrives<br />

Pubblicazione 22B QSOOl B IT P Gennaio 2004<br />

Rockwell<br />

Automation<br />

Sostilulsce la pubblica zlone<br />

del mese di onobre 2002<br />

Copyright C2004 Rockwell Automation Inc Tutti i diri1ti riservati Stampato InTaiwan


tm<br />

Variador de Velocidad de<br />

CA de Frecuencia<br />

Ajustable PowerFlex 40<br />

FRN 2 xx<br />

Inicio Rapido<br />

Esta Gufa de Inicio Rapido resume los pasos basicos necesarios<br />

para instalar<br />

poneren marcha y programar el Variadorde Velocidad de CA de Frecuencia<br />

Ajustable PowerFlex 40 La informacion provista lS2 reemplaza al Manual<br />

del Usuario y esm diseiiada solo para el personal de servicio calificado<br />

del variador<br />

Para obtener informaci6n detallada sobre elPowerFlex 40 incluyendo<br />

instrucciones EMC consideraciones sobre la aplicaci6n y precauciones<br />

relacionadas consulte elManual de Usuario delPowerFlex 40 Publicaci6n<br />

22B UMOO1<br />

en el CD suministrado con el variador 0 en wwwab comlmanuals dr<br />

Precauciones Generales<br />

ATENCION EI variador contiene capacitores de alta tensi6n los cuales<br />

demoran algun tiempo en descargarse despues de retirar el suministro electrico<br />

Antes de en trabajar el variador verifique el aislamiento delsuministro eJectrico<br />

en las Ifneas de alimentaci6n R S T Ll L2 L3 Espere tres minutos para<br />

de tensi6n El<br />

que se descarguen los capacitores hasta niveles seguros<br />

incumplimiento deestas indicaciones puede resultar en lesiones personales<br />

o la muerte<br />

Los indicadores LED apagados no constituyen una indicaci6n de que os<br />

capacitores se hayan descargado hasta niveles de tensi6n seguros<br />

ATENCION Pueden ocurrir lesiones person ales 0 dafio al equipo si el<br />

parametro A092 Int rearme<br />

auto<br />

0 elA094 Inic al encender seusan en<br />

una aplicaci6n incorrecta No uti ice esta funci6n sin considerar los reglamentos<br />

estandares c6digos locales nacionalese intemacionales y as pautas de la<br />

industria<br />

ATENCION S610 el persona cualificado y familiarizado conlos variadores<br />

de velocidad de CA y las maquinarias asociadas debe 0<br />

planificar realizar la<br />

instalaci6n la puesta en marcha y el mantenimiento subsiguiente del sistema<br />

EI incumplimiento de estas indicaciones puede res ultaren lesiones personales<br />

y o dafio a equipo<br />

ATENCION Este variador tienecompOJientes y nsamblajes sensibles alas<br />

ESD Descargas Electrostaticas Se deben tomar precauciones de contr61 de<br />

estatica a instalar probar realizar el servicio 0 reparar este dispositivo El no<br />

seguir los procedimientos de control de ESD puede resultar en dafio a los<br />

componentes Si no esta familiarizado con los procedimientos de control de<br />

estatica consulte a publicaci6n de A B 8000 4 5 2 Guarding Against<br />

Electrostatic Damage Protecci6n contra Dafio Electrostatico 0 cualquier<br />

otro manual de protecci6n contra ESD pertinente<br />

ATENCION La instalaci6n 0 aplicaci6n incorrecta de un variador puede<br />

resultar en dafioa los componentes 0 en una menorvida uti de producto Los<br />

errores de cableado 0 de aplicaci6n tales como tamafio insuficiente del motor<br />

fuente de alimentaci6n de CA incorrecta 0 inadecuada 0 temperaturas ambiente<br />

excesivas pueden resultar en un funcionamiento defectuoso del sistema


Espaiiol 2<br />

Consideraciones de Montaje<br />

lnstale el variador en posici6n haciaarriba sobre una superficie vertical<br />

y a nivel<br />

Bastidor Tamafio del Par del Tornlllo Riel DIN<br />

Tornillo<br />

B M4 8 32 1 56 1 96 N m 14 17Ibs pulg 35mm<br />

C M5 10 24 245 2 94 N m 22 26Ibs pulg<br />

Evite el polvo 0 Ias partfculas metaticas para proteger eI ventilador de<br />

enfriamiento<br />

No 10 exponga a unaatm6sfera corrosiva<br />

Proteja launidad contra la humedad y Ia Iuz solar directa<br />

Distancias Libres Mfnimas de Montaje<br />

La pagina 16 contiene informaci6n sobre las dimensiones de montaje<br />

v 0 V<br />

120mm<br />

47 pulg<br />

odo bo odo bo<br />

Jpoo Jpoo<br />

0 0<br />

120mm<br />

47 pulg<br />

0 0<br />

I II I<br />

o o<br />

110Pci6n<br />

de Montaje A<br />

No se requiere espacio<br />

fibre entre variadores<br />

Opci6n de Montaje B<br />

Temperaturas Ambiente de Operaci6n<br />

e<br />

odo bo<br />

Jpoo<br />

25mm<br />

1 1 0 pulg<br />

V 0<br />

120mm<br />

47 pulg<br />

odo bo<br />

Jpoo<br />

0<br />

I<br />

o 0<br />

120mm<br />

47 pulg<br />

I I IrI<br />

Temperatura Ambiente Capacidad Nominal del Distancias Libres Mfnimas<br />

Mlnimo Maximo<br />

Envolvente de Montaje<br />

40 C 104 F<br />

IP 20ffipo Abierto Use la Opci6n de Montaje A<br />

10 C 14 F IP 30 NEMA I UL Tipo 1111 Use la Opci6n de Montaje B<br />

1<br />

50 C 122 F IP 20ffipo Abierto Use la Opci6n de Montaje B<br />

La capacidad nominal requiere la instalaci6n del conjunto opcional PowerFlex 40 IP 30INEMA lUL<br />

Tipo 1<br />

Requisitos Generales de Conexi6n aTierra<br />

Importante Retire el MOV para conectar atierra la conexi6n en puente si el<br />

variador esla instalado en un sistema de distribuci6n sin conexi6n a tierra<br />

Apriete el tornillo despues de retirar la conexi6n en puente<br />

CJ<br />

00000<br />

6000<br />

G<br />

Cumplimiento de Normativas CE<br />

Consulte eJ Manual del Usuario del PowerFlex 40 en el CD suministrado con el<br />

variador para obtener detalles sobre c6mo cumpIir conIas nonnativas sobre Baja<br />

Tensi6n LV y de Compatibilidad Electromagnetica EMC


Specificaciones Fusibles y Oisyuntores<br />

Capacidades Nominales del Variador<br />

Numero de<br />

Catalogo<br />

Capacidades Capacldades Nominales<br />

Nominales de Salida de Entrada<br />

Proteccion de Circuitos Secundarios<br />

22B V2P3N104 0410 5 2 3 90 132 15 9 0 15 140M C2E C16 100C12 30<br />

22B V5PON104 0 75 1 0 5 0 90 132 245 20 3 35 140M D8E C20 100C23 56<br />

22B V6PON104 111 5 6 0 90132 3 0 24 0 40 140M F8E C32 l00C37 70<br />

Entrada monotaslca 1 de 200 240 V CA 010 10 Salida trifasica de 0 230 V<br />

22B A2P3N104 0410 5 2 3 180264 15 6 0 10 140M C2E B63 100 C09 30<br />

22B A5PON104 0 75 1 0 5 0 180 264 245 120 20 140M C2E C16 100 C 12 55<br />

22B A8PON104 1 512 0 8 0 180 264 4 0 18 0 30 140M D8E C20 100C23 80<br />

22B A012N104 2 2 3 0 12 0 180 264 5 5 25 0 40 140M F8E C32 100 C37 110<br />

Entrada trifaslca de 200 240V CA 010 Salida trifasica de 0 230 V<br />

22B B2P3N104 0410 5 2 3 180264 15 2 5 6 140M C2E B40 100C07 30<br />

22B B5PON104 075 1 0 5 0 180 264 245 57 10 140M C2E C10 100 C09 55<br />

22B B8PON104 1 5 2 0 8 0 180 264 4 0 9 5 15 140M C2E C16 100C12 80<br />

22B B012N104 2 2 3 0 12 0 180 264 5 5 15 5 25 140M C2E C16 100C23 115<br />

22B B017N104 3 715 0 17 5 180264 8 6 210 35 140M F8E C25 100 C23 165<br />

22B B024N104 5 517 5 24 0 180 264 118 26 1 40 140M F8E C32 100C37 226<br />

22B B033N104 7 5 10 0 33 0 180 264 16 3 34 6 60 140M G8E C45 100 C60 290<br />

Entrada trlfasica de 380 480V CA 010 Salida trifasica de 0 460V<br />

22B D1P4N104 0410 5 14 342 528 14 1 8 3 140M C2E B25 100 C07 30<br />

22B D2P3N104 0 75 1 0 2 3 342 528 2 3 3 2 6 140M C2E B40 100C07 40<br />

22B D4PON104 1 5 2 0 4 0 342528 4 0 5 7 10 140M C2E B63 100C09 60<br />

22B D6PON104 2 2 3 0 6 0 342528 5 9 7 5 15 140M C2E Cl0 100 C09 90<br />

22B D010N104 4 0 5 0 10 5 342 528 10 3 13 0 20 140M C2E C16 100 C23 150<br />

22B D012N104 5 5 7 5 12 0 34252e 118 142 25 140M D8E C20 100C23 160<br />

22B D017N104 75 10 0 17 0 342 528 16 e le4 30 140M D8E C20 100C23 200<br />

22B D024N104 110115 0 240 342528 234 26 0 50 140M F8E C32 100C43 285<br />

Entrada trifaslca de 460 600V CA 010 Salida trifasica de 0 575 V<br />

22B E1P7Nl04 0 7511 0 1 7 414660 2 1 2 3 6 140M C2E B25 100C09 40<br />

22B E3PON104 1 5 2 0 3 0 414 660 3 65 3 8 6 140M C2E B40 100C09 60<br />

22B E4P2Nl04 2 2 3 0 4 2 414 660 5 2 5 3 10 140M C2E B63 100C09 90<br />

22B E6P6N104 4 0 5 0 6 6 414 660 8 1 8 3 15 140M C2E Cl0 100C09 150<br />

22B E9P9N 1 04 5 5 7 5 9 9 414660 12 1 112 20 140M C2E C16 100 C16 160<br />

22B E012Nl04 7 5 10 0 12 2 41 4 660 14 9 137 25 140M C2E C16 100C23 200<br />

22B E019NI04 110115 0 19 0 414660 23 1 24 1 40 140M D8E C25 100C30 285<br />

Espaiiol 3<br />

1 Los variadores monofasicos de 200 240 V CA tambien estan disponibles con un filtro EMC integral EI sufiio de<br />

catalogo cambia de N104 a N114<br />

12 Consulte la Gula de Selecci6n de Protectores de Motor 140M publicaci6n 140M<br />

bastidor y la capacidad de frenado necesaria para su aplicaci6n<br />

para<br />

SG001<br />

determinar el


Espafiol 4<br />

Salida Programabla rel da formaC<br />

Cepacldad Nominal Reslstiva 3 0 A a 30 V CC 3 0 A a 125 V CA 3 0 A a 240V CA<br />

Cepacldad Nomlnallnductiva 0 5 A a 30 V CC 0 5 A e 125 V CA 0 5Ae240 V CA<br />

Fusibles y Disyuntores<br />

Tipo de FuslblaReromendado UL Clase J CC T 0 Tipo BSB8 600 V 550V 0 equivalente<br />

Oisyun oras raoomendados Olsyuntores HMCP 0 equlvalente<br />

Caracteristicas de Protecci6n<br />

@YULSDBC c@yCSA22l C<br />

sm<br />

E EMC<br />

Illrecl<br />

LV EN 50178 EN 60204<br />

EMC EN 61800 3EN 50081 EN 500B2 2<br />

Safidas dp icas<br />

30 V CC 50 mA<br />

No Inductlva<br />

Safidas ana1dgicas 10 bit<br />

0 10 V lkohmMin<br />

4 20 mA 525 ohmlosMAx<br />

Proteceidn del M r lt protecci6n contra sobrecarga 150 durante 60 segundos 200 duranta 3 segundos Proporclona Protecci6n Clese 10<br />

Sobracorrien e 200 limite del hardware 300 lallo instantAneo<br />

t Sobra ansidn Entrada de 00 120 V CA Ocurre el disparo a 405V CCde la tensi6n del bus eqUivalente a una linea de entrada de 150<br />

Entrada de 200240 V CA Ocurre el disparo a 405V CCde la tensi6n del bus equivalanta a una IInaa de entrada de 290V CA<br />

Entrada de 360 460 V CA Ocurre al disparo a 810V CCde la tonsl6n del bus equlvalanta a una linea de entrada de 575 V CA<br />

Entrada de 46D 800 V CA Ocurro 01 disparo a 1005 V CC de la tens ndel bus aquivalante a una linea de entrada de 711 V CA<br />

lequivalente<br />

Baja Tensidn Entrada de 100 120 V CA Ocurre el disparo a 210V CC de la lonsl6n del bus a una linea de entrada de 75 V CA<br />

Entrada de 200240 V CA Ocurre 01 disparo a 210V CC de la tonsl6n del bus equivalento a una linea de entrada de 150 V CA<br />

Entrada de 380 480 V CA Ocurre el disparo a 390V CC de la lensi6n del bus equivalente a una linaa de entradade275 V CA<br />

Entrada de46D 8OO V CA Si ocurre un disparo P042 3 1ensi6n alla a una IeI1siOOde bus de 487 V CC 344 V CA de linea de entrada<br />

Siocurre un disparo P042 21oosl6n baja a una tensi6n de busde 390 V CC 275 V CA delinea deentrada<br />

Cicio de Mantenimiento de Con rol EI Cicio de Mantenimlento de Control mlnlmo es de 0 5 segundos el valort1pico es de 2 segundos<br />

CicIo de Mantenimlento de Afimen ecidn flee ricasin Fallo 100 milisegundos<br />

Frenado Dinamico<br />

Se incluye ellGBT de Ireno Interno con todas las capacldades nominalas Consulle el Anexo B del Manual del Usuariodel PowerFlex 40 en el CD<br />

para oblener informaci6n sabre pedidosde reslstencia DB<br />

veAl


Uneas defuerza<br />

Capacidad Nominal de Potencia<br />

No apantaliado 600 V 75 C 167 F THHNfTHWN<br />

Blindado 600 V 75 C 0 90 C 167 F 0 194 F RHH RHW 2<br />

Bandeja Blindada con capacidad nominal 600 V 75 C 0 90 C<br />

167F 0 194 F RHH RHW 2<br />

1<br />

Terminal<br />

Descripci6n<br />

AILI SL2 Entrada Monofasica<br />

RILl SL2 TL3 Entrada Trifasica<br />

OlD<br />

Alambre de Cobre<br />

Recomendado<br />

Espanol S<br />

15 mili simas con aislamiento<br />

ubicaci6n seca<br />

Anixter OLF 7xxxxx<br />

Belden 29501 29507 0<br />

equivalente<br />

Anixter 7V 7xxxx 3G<br />

Shawflex 2ACD 3ACD 0<br />

equivalente<br />

UfT1 AI Motor UfTl<br />

Conrnute cualesquiera<br />

VfT2 AI Motor VfT2<br />

dos conductores delmotor<br />

para cambiar la direcci6n<br />

WfT3 AI Motor WfT3 de avance<br />

P2 PI<br />

Conexi6n de inductor de bus de CC unicamente en variadores con bastidor C<br />

EI variador con bastidor C se envia con una conexi6n en puente<br />

entre los terminales P2 y Pl Retire este puente de conexi6n<br />

unicamente cuando se vaya a conectar un Inductor de Bus de CC EI<br />

variador no se activara si no esta presente una conexi6n en puente 0 un inductor<br />

DCt DC Conexi6n del Bus de CC<br />

BRt BR<br />

Conexi6n de Resistencia de Frenado Dinamico<br />

@ Conexi6n a Tierra de Seguridad PE<br />

1<br />

Importante Los tornillos de terminales pueden aflojarse durante el envio Asegurese que<br />

todos los tornilios de terminales esten apretados con el par recomendado antes de aplicar la<br />

alimentaci6n electrica al variador<br />

Especificaciones del Bloque de Terminales de Potencia<br />

Bastidor Dilime<br />

w Maximo del Dilime 50 Minimo del Par de apriete<br />

Cable Cable<br />

B 5 3 mm2 10 AWG 13 mm2 16 AWG 1 7 2 2 N m 16 19Ibs pulg<br />

C 8 4 mm2 8 AWG 13 mm2 16 AWG 2 9 3 7 N m 26 33 ibs pulg<br />

2 Diametros maxirnos minimos compatibles con el bloque de terminales Esto no constituye<br />

recomendaci6n alguna


Espaiiol 6<br />

Condiciones de la Potencia de Entrada<br />

Condici6n de laPotencia de Entrada Accl6n Correctiva<br />

Impedancia de Linea l<br />

Baja menos de I de la reactancia Instale el Reactor de L1nea<br />

de linea o Transformador de Aislamiento<br />

Mayor que el transformador de alimentaci6n elilctrica<br />

de 120 kVA<br />

o inductor de Bus 5 5 11 kW<br />

7 5 15 HP unicamente para<br />

variadores<br />

La linea tiene condensadores de correcci6n del factor Instale el Reactor de Linea<br />

de potencia o Transformador de Aislamiento<br />

La linea tiene interrupciones frecuentes de potencia<br />

La linea tiene picos intermitentes de ruido en exceso de<br />

6000 V rayo<br />

La tensi6n de fase a tierra excede el125 de linea normal Retire el puente de conexl6n MOV<br />

a tensi6n de linea a tierra<br />

Sistemas de distribuci6n sin conexi6n a tierra<br />

o instale el Transformador de<br />

Aislamiento con uno secundario con<br />

conexi6n a tierra si fuera necesario<br />

240 V en configuraci6n delta estrella Instale el Reactor de Linea<br />

1 Consulte el Anexo B del Manual del Usuario dei PowerFlex 40 en el CD para obtener informaci6n<br />

sobre e pedido de accesorios<br />

Recomendaciones de Cableado de E1S 2<br />

Tlpos de Cables Descripci6n Capacidad Nominal de<br />

Aislamlento Minima<br />

Belden 8760 9460 0 8 mm2 18AWG par torcido 100 0 equiv<br />

Belden 8770<br />

con drenaje<br />

0 8 mm2 18AWG<br />

apantallado<br />

3 conductores apantallado<br />

300 V<br />

60 grados C<br />

140 grados F<br />

0 equiv para pot remoto solamente<br />

2 Si los cables son cortos y estan contenidos en un envolvente sin circuitos sensibles quiza no sea<br />

necesario el uso de cable apantallado pero siempre se recomienda<br />

Especificaciones del Bloque de Terminales de E1S<br />

Bastidor<br />

Maximo del<br />

Diamel50 Diamel50 Minimo del Par de apriete<br />

Cable Cable<br />

ByC 1 3 mm2 16 AWG 0 13 mm2 26 AWG 0 5 0 8 N m 47Ibs pulg<br />

3 Diametros maximos minimos compatibles con el bloque de terminales Esto no constituye<br />

recomendaci6n alguna<br />

ConsuIte el Manual del Usuario del PowerFlex 40 en el CD para obtener las<br />

recomendaciones sobre la potencia maxima y la longitud delcable de control


t<br />

Ioque de Terminales de Control<br />

Diagrama del Bloque del Cableado de Control<br />

4<br />

Puente de Habilitaci6n<br />

f<br />

24V<br />

01<br />

02<br />

03<br />

04<br />

05<br />

06<br />

07<br />

08<br />

13<br />

14<br />

Espai iol<br />

Cableado Cableado<br />

Tipico de Tiplco de<br />

1<br />

p aro<br />

Fuente SRC Orenador SNK<br />

W oL<br />

Dir Run REV<br />

Comun Digital<br />

Entrada Digital 1<br />

Arranque Marcha de Ava<br />

Entrada Digital 2<br />

Entrade Digital 3<br />

Entrade Oigital4<br />

Opto Comun<br />

24 V CC<br />

10 V CC<br />

Entreda Dl0V 0 10V<br />

Comun Anel6gico<br />

I<br />

Rela NA<br />

Comun de Rela<br />

Rl<br />

R2<br />

15<br />

16<br />

Ent de 4 20 mA<br />

Salida Anal6gica<br />

Pot debe<br />

serde<br />

1 10kohmios<br />

2 Watt minimo<br />

3<br />

Salida 6ptica 1<br />

Comun<br />

Aela NC<br />

R3 17 024V<br />

30VCC<br />

L so mA<br />

No inductiva<br />

I<br />

I 0 10v seleCClonarsallda<br />

B<br />

VO<br />

Anal6glca V<br />

20 mA 01<br />

V<br />

02 03 04 05 06<br />

Al A2 R3<br />

SNK<br />

00 CID CID CID CID<br />

CID CID CID 8<br />

SAC<br />

Importante EI Terminal de ES 01 esta siempre establecido<br />

para el paro por inercia excepto cuando P036 Fuente<br />

Arranque esta establecido para control de 3 hilos En el<br />

control de tres hilos el Terminal de ES 01 esta controlado por<br />

P037 Modo de Parol Todas las demas fuentes de paro esf8n<br />

controladas por P037 Modo de Parol<br />

1<br />

18<br />

19<br />

Salida 6ptica 2<br />

Pantalla RS485 OS I<br />

Importante EI variador se envia con un puente de conexi6n<br />

instalado entre los Terminales de ES 01 Y 11 Retire este<br />

puente de conexi6n al utilizar este Terminal de ES 01 como entrada de paro 0 de habilitaci6n<br />

2 Se muestra el control de dos hilos Para el control de tres hilos utilice una entrada momentanea en<br />

el Terminal E S 02 a modo de comandar un arranque Use una entradacon mantenimiento cYo para el Terminal<br />

de ES 03 a modo de cambiar de direcci6n<br />

3<br />

AI usaruna salida 6ptica con una carga inductiva como un rele instale un diodo de recuperaci6n paraielo al rele<br />

segun se muestra para evitar daiio a la salida<br />

4<br />

P036 Fuente Para Paro Tenninal de EIS 01<br />

Arranque<br />

Teclado Segun P037 Inercia<br />

TresHilos Segun P037 n P03 Sag<br />

Dos Hilos Segun P037 lnercla<br />

Puerto RS485 Segu P037 Inercia<br />

AI retirar la conexi6n en puente ENBL el Terminal 01 de E1S siempre actuara como habilitaci6n por hardware y<br />

causara un paro por inercia Consulte el Manual del Usuario del PowerFlex 40 en el CD para mas informaci6n<br />

7


Espaiiol S<br />

Designaciones de Control de Terminales de E1S<br />

Valor<br />

No Senal Predeterminado Oescripcl6n Paramo<br />

Rl Rell NA Fallo Contacto normalmente abierto para el rail de salida A055<br />

R2 Comun de Rele Comun para rele de salida<br />

R3 Rele N C Fallo Contacto normal mente cerrado para el rele de salida A055<br />

Microinterruptor de selecci6n 0 10 V<br />

de salida anal6gica<br />

Microinterruptor<br />

de Drenador Fuente<br />

01 Paro ll<br />

Fuente SRC<br />

Establece la salida anal6gica en tensi6n 0en corriente Los ajustes deben<br />

corresponder conA065 Sel Sal Anlg<br />

Les entradas sa pueden cablear como Drenador SNK 0 Fuente SRC<br />

mediante ajustes de los microinterruptores<br />

Inercia Es necesario que este presente un puente de conexi6n P0361 I<br />

instalado enfabrica 0 una entrada normalmente cerrada para<br />

que arranque el variador<br />

02 Arranque Marcha de No esta Activo EI comando proviene del teclado integral por defecto Para P036 P037<br />

Avance FWD inhabilitar la operacl6n en reversa consulte A095 Ilnver<br />

03 air Run REV No esta Activo<br />

Oeshab<br />

04 Comun Digital Para entradas digitales Electr6nicamente aisladas con<br />

entradas digitales da ElS anal6gicas y salidas 6pticas<br />

05 Entrada Digital 1 Frec presel Programa conA051 Sel ent digt 1 J A051<br />

P036 P037<br />

A095<br />

06 Entrada Digital 2 Frec presel Programa conA052 Sel ent digt 2 A052<br />

07 Entrada Digital 3 Local Programar con A053 Sel ent digt 3J A053<br />

08 Entrada Digital 4 Impulsos Avance Pro9ramar conA054 Sel ent digt 4 A054<br />

09 Opto Comun Para las salidascon acoplamientos 6pticos Electr6nicamente<br />

11 24 V CC Referido al Comun Digital<br />

aisladas consalidas 6pticas da ElS anal6gicas y entradas<br />

digitales<br />

Potencia provista por el variador para las entradas digitales<br />

Lacorriente maxima da salida es de 100 mA<br />

12 10VCC Referido al Comun Anal69ico P038<br />

13 Ent 10 V 2<br />

Alimentacl6n electrica provista por el variador para el<br />

potenci6metro externo de 0 10 V<br />

Lacorriente maxima de salida es de 15 mA<br />

No esta Activo Para la alimentaci6nde entrada externade 0 10V unipolar 0 P038<br />

10 V bipolar impedancia de entrada lOOk ohmios 0 A051 A054<br />

Iimpiador da potenci6metro<br />

A123 A132<br />

14 Comun Anal6gico Para Ent de 0 10 V 0En de 4 20 mA Electr6nicamente<br />

15 Ent da 4 20 mA<br />

1<br />

aislado conentradas y salidas anal6gicas de ElS digitales y<br />

salidas 6pticas<br />

No esta Activo Para alimentaci6n extema da entrada de 4 20 mA P038<br />

impedancia 250 ohm A051 A054<br />

16 Salida Anal6gica FrecSal 0 10 La salida anal69ica predeterminada es de 0 10 V Para A065 A066<br />

convertir aun valor de corriente cambie el microinterruptor<br />

DIP SeleccionarSalida Anal69ica en0 20mA Programar con<br />

A065 Sel Sal Antg EI valor anal6gico maximo se puede<br />

escalar con A066 Sal Anlg Mroc<br />

Carga maxima 4 20 mA 525 ohmios 10 5 V<br />

0 10V lkohmio 10mA<br />

17 Salida 6ptica 1 MotorMarcha Programar conA058 Sel Sal 6ptica I A058 A059<br />

A064<br />

18 Salida 6ptica 2 En Frecuencia programar conA061 Sel Sal6ptica2j A061 A062<br />

19 Pantalla RS485 OSI AI usarel puerto de comunicacionesRS485 DSI dabern<br />

conectarsa el terminal a la tierra dese9uridad<br />

1 Vea la nota de pie 1 Y 4 en la pagina 7<br />

2 En de 0 10 V Y Ent de 4 20 mA son canales de entrada d erentes y se pueden conectar simultilneamente<br />

Se pueden usarlas entradas independientemente para controlar ta velocidad 0 en conjunto al funcionar en modo PID<br />

A132<br />

A064


o<br />

Preparaci6n<br />

de la Puesta en Marcha del Variador<br />

Espaiiol 9<br />

ATENCION La fuente de alimentaci6n debe estar conectada al variador para<br />

realizar los siguientes procedimientos de puesta en marcha Algunas de Jas<br />

tensiones presentes estan al potencial de laIfnea de entrada Para evitar el peligro<br />

de descarga electrica 0 daiio alequipo el siguiente procedimiento debe ser<br />

realizado s6lo por personal de servicio calificado Lea detalladamente y entienda<br />

el procedimiento antes de comenzar Si un evento no se produce durante la<br />

realizaci6n de este procedimiento No Proceda Des onecte la fuentede<br />

alimentacion incluso las tensiones de control suministradas por el usuario Es<br />

posible que existan tensiones suministradas por el usuario auncuando la<br />

potencia de CA no se encuentre conectada al variador Corrija el mal<br />

funcionamiento antes de continuar<br />

Antes de Conectarla Fuente de Alimentaci6n al Variador<br />

1 Confinne que todas las entradas se encuentren firmemente conectadas a los<br />

tenninales correctos<br />

o 2 Verifique que la potencia de Ifnea de CA en el seccionador se encuentre<br />

dentro del valornominal del variador<br />

o 3 Verifique que tocta la potencia de control digital sea de 24 voltios<br />

o 4 Verifique que los ajustes del microinterruptor Drenador SNK Fuente SRC<br />

esten configurados de manera cOITespondiente con elesquema de cableado de<br />

control Yea la pagina 7 para conocer la ubicaci6n<br />

Importante El esquema de control predetenninado es el de Fuente SRC EI<br />

tenninal de Pato se conecta en puente Terminales de E S 0 y I<br />

para pennitir la puesta en rnarcha desde el teclado Si se cambia el<br />

esquema de control a Drenador SNK sera necesario retirar el<br />

puente de conexi6n de los terminales de E S 01 y I I e inst alarse<br />

entre los tenninales de E S 0 Y 04<br />

o 5 Verifique que este<br />

presente la entrada de Paro 0 no se en pondra marcha el<br />

variador<br />

Importante Si se utiliza el Tenninal de E S 0 como entradade paro el puente<br />

de conexi6n entre los Terminales de E S OJ Y 1 debe retirarse<br />

Conexi6n de la Fuente de Alimentaci6n al Variador<br />

o 6 Conecte la potencia de CA y las tensiones de control al variador<br />

o 7 Familiarfcese con las caracterfsticas del teclado integral veala pagina<br />

siguiente antes de ajustar cualquier parametro del Grupo de Programaci6n<br />

Arranque Para Control de Direcci6n y Velocidad<br />

Los valores de parametro predeterminados de fabrica permiten controlar el<br />

variador desde el teclado integral No es necesaria programaci6n alguna para<br />

poner en marcha detener cambiar la direcci6n y controlar la velocidad<br />

directamente desde el teclado integral<br />

Importante Para inhabilitar la operaci6n en reversa consulte A095 Inver<br />

Deshab<br />

Si aparece un fallo durante el arranque l pagina 7 presenta una explicaci6n del<br />

c6digo de fallo Para obtenerinfonnaci6n completa sobre la resoluci6n de fallos<br />

consulte el Manual del Usuario del PowerFlex 40 en elCD suministrado con el<br />

variador


Espaiiol 10<br />

rJ<br />

Teclado Integral<br />

00 00<br />

@W@<br />

00<br />

10<br />

CD Q<br />

10<br />

No LED Estado del Descripci6n<br />

Indicador LED<br />

Menu Descrlpcl6n<br />

d<br />

p<br />

R<br />

F<br />

Grupo deVlsuallzacl6n S61o para vlsuatizacl6n<br />

Conslste an las condiciones da tuncionamlento del<br />

variadorvisualizadas con mayor frecuencia<br />

GNpO da Programacl6n Bblca<br />

Consiste en las funciones programablesutilizadas con<br />

mayor frecuencia<br />

Grupo de Programacl6n Avanzada<br />

Conslste en el reSode las tunciones progmmables<br />

Deslgnadorda Fallos<br />

Consiste en lalista da c6digos pam condicionas da rallo<br />

especfficas Aparece unicamente ante la presenciade untallo<br />

0 Estado de Rojo Continuo Indica que el variador esta luncionando y comand61a direcci6n<br />

MarchalDirecci6n del motor<br />

R6jo Intermitente EI variador ha indicado el cambio de direcci6n Indica la direcci6n real<br />

del motor mientras reduce la aceleraci6n a cero<br />

@ Pantalla Rojo Continuo Indica el numero de parametro elvalor del parametro 0 c6digo<br />

Altanumerica de fallo<br />

Rojo Intermitente Un s610<br />

ditto intermitente indica que puede modilicarse dicho digito<br />

Todos los igitos intermltentes es indicaci6n de una condici6n de lallo<br />

@ Unidades Rojo Continuo Indica las unidades del valor del parametro mostrado en pantalla<br />

Mostradas<br />

0 Estado del Rojo Continuo Indica que se puede cambiar elvalorde parametro<br />

Programa<br />

0 Estado de Fallo Rojo Intermitente Indica que el variador tiene un lallo<br />

0 Estado del Verde Continuo Indica que el potenci6metro en el Teclado Integral esta activo<br />

Potenci6metro<br />

0 Estado de la Tecla Verde Continuo Indica que la Tecla de Arran ue en el Teclado Integral esta activa<br />

de Arranque<br />

La tecla de Retroceso tambi n esta activa a menos que se inhabllite<br />

por medio del A095 Inver Deshab<br />

No Tecla Nombre Descripcl6n<br />

0 Escapar Retroceder un paso en el menu de programaci6n<br />

Anular un cambio a un valor de panimetro y salir del Modo de<br />

Programaci6n<br />

@ Seleccionar Avanzar un paso en el menu de programaci6n<br />

Seleccionar un diglto al visualizar elvalordel parametro<br />

0<br />

@@ Flecha Hacia Arriba Permite desplazarse a traves de grupos y panimetros<br />

Flecha Hacia Abajo Aumenta 0 reduce el valor de un digito intermitente<br />

@ Ingresar<br />

Potenci6metro<br />

Avanzar un paso en el menu de programaci6n<br />

Guardar un cambio a un valor de parametro<br />

Se usa para controlar la velocidad del variador La condici6n<br />

predeterminada es activa<br />

Se controla por medio del parametro P038<br />

CD Arranque Se utiliza para poner en marcha el variador La condici6n<br />

predeterminada es activa<br />

Se controla por medio del parametro P036<br />

Q Paro<br />

Retroceso Se usa para invertir la direcci6n del variador La condici6n<br />

predeterminada es activa<br />

Se controla por medio de los parametros P036 y A095<br />

Se usa para detener el variador 0 borrar un tallo<br />

Esta tecla siempre esta activa<br />

Se controla pormedio del parametro P037


Paso<br />

sualizaci6ny<br />

Edi i6n de Parametros<br />

Espaiiol 11<br />

EI ultimo parametro del Grupo de Visualizaci6n utilizado porel usuario se guarda al interrumpir la<br />

alimentaci6n electrica y se muestra en pantalla pordefecto al volverse a aplicar la alimentaci6n<br />

elect rica<br />

A continuaci6n se presenta un ejemplo de las funciones basicas del teclado integral y la pantalla<br />

Este ejemplo proporciona instrucciones basicas de navegaci6n e ilustra c6mo programar el<br />

primer parametro del Grupo de Programaci6n<br />

1 AI aplicar la alimentaci6n electrica aparece<br />

brevemente con caracteres intermitentes el ultimo<br />

numero de parametro de Grupo de Visualizaci6n<br />

seleccionado porel usuario La pantalla entonces<br />

muestra pordefecto el valor actual del pan metro<br />

EI ejemplo muestra el valor de dOOl Frec Salida<br />

con el variador detenido<br />

2 Pulse Esc una vez para visualizar el numero de<br />

parametro de Grupo de Visualizaci6n que se<br />

muestra durante la puesta en marcha EI numero<br />

de parametro se iluminara intermitentemente<br />

3 Vue va a pulsar Esc para ingresar al menu de<br />

grupo La letra del menu de grupo se iluminara<br />

intermitentemente<br />

4 Pulse la tecla de Flecha Hacia Arriba 0 Hacia<br />

Abajo para desplazarse a traves del menu de<br />

grupo d PyA<br />

5 Pulse Enter 0 Sel para ingresar a un grupo EI<br />

digito de la derecha del ultimo parametro<br />

visualizado en ese grupo se iluminara<br />

intermitentemente<br />

6 Pulse las fiechas Hacia Arriba 0 Hacia Abajo para<br />

desplazarse por 105 parametros que estan en e<br />

grupo<br />

7 Pulse Enter 0 Sel para ver elvalor de un<br />

parametro Si no desea editar el valor pulse Esc<br />

para regresar al numero del parametro<br />

8 Pulse Enter 0 Sel para accederal modo de<br />

programaci6n y modificar elvalor del parametro EI<br />

digito de la derecha se lIuminara intermitentemente<br />

y el indicador LED del Programa se iluminara si se<br />

puede modificar el parametro<br />

9 Pulse las f1echas Hacia Arriba 0 Hacia Abajo para<br />

cambiar el valor del parametro Si 10 desea pulse<br />

Se para moverse de dfgito a digito 0 de bit a bit EI<br />

digito 0 bit que puede cambiar parpadeara<br />

10 Pulse Esc para cancelar un cambio EI digito dejara<br />

de parpadear se restaura elvalor anterior y se<br />

apagara el indicador LED del Programa<br />

o bien<br />

Pulse Enter para guardar un cambio EI dfgito<br />

dejara de parpadear y se apagara el indicador LED<br />

del Programa<br />

11 Pulse Esc para regresar a la lista de parametros<br />

Continue pulsando<br />

programaci6n<br />

Esc para salir del menu de<br />

Si al pulsar Esc no cambia la pantalla entonces<br />

aparecera dOOI Free SalidaJ Pulse Enter 0 Sel<br />

para ingresar al menu de un grupo<br />

Tecla s<br />

fi fO<br />

Jvobien<br />

obien@<br />

fJobien@<br />

Ejemplo de Pantallas<br />

Id n n 10 VOLTS<br />

U u l<br />

PROGRAM FAULT<br />

o 0<br />

IdOO<br />

n<br />

U U<br />

PROGRAM FAULT<br />

o 0<br />

PROGRAM FAULT<br />

0 0<br />

P 0 3<br />

PROGRAM FAULT<br />

o 0<br />

nlo<br />

I<br />

I<br />

vOLTS<br />

O VOLTS<br />

AMPS<br />

a HERTZ<br />

obien@ I 2 3 unlevoLTs<br />

PROGRAM FAULT<br />

0 0<br />

90bien@ I 2 3<br />

QDo bien @<br />

PROGRAM FAULT<br />

0<br />

0 AMPS 9 2 2 0 HERTZ UnlevoLTs PROGRAM FAULT<br />

o 0<br />

IP 0 3 1H<br />

PROGRAM FAULT<br />

o 0


Espaiiol 12 Vaa al Manual dal Usuano del Powerflax 40 en CD para obtaner Inlormaci6n sobre los paramelros<br />

Parametros de Grupo deVisualizaci6n<br />

No Parametro MinIMax Pantalla Opclones<br />

dOOI IFrec Salida O O Frecuencia Max 0 1 Hz<br />

dOO2 Free da comandol O O Frecuencia MAx I 0 1 Hz<br />

dOO3 lint salida O OO Intens var x 2 0 01 Amps<br />

d004 Tens de selidal ONolts nomln var I VCA<br />

dOOS Tensi6n bus CC Besado en la capatidad I VCC<br />

nominal dal variador<br />

d006 Estado Variador 01 t Condici6n Verdadere fliL3 Illl 2 Bill JliLll<br />

Decelerando Acelarando Avance Funclonendo<br />

dOO7<br />

d009<br />

IC6 ligo fallo xl F2IF122 Fl<br />

dOlO IDisplay Procesol 0 00 9999 0 01 t<br />

dOl2 Fuente Control 09 Bil1 Comando de velocidad B 0 Comando de arranoUfl<br />

Vea P038 9 Free Impulsos Vea P036 9 Impulso1<br />

dOl3 Estado ant Cntrll Oil I Entreda presante fliL3 Illl 2 Bill JliLll<br />

Tran DB Enc Ent Paro EnlDirlRev EnVA Ava<br />

dOl4 Estado ant digit 01 I Entrada presente fliL3 Illl 2 Bill JliLll<br />

En digit 4 En digit 3 En digit 2 En digit 1<br />

d01S IEstadocom 011 1 Condici6n Verdadara fliL3 Illl 2 Bill JliLll<br />

Fallo comun Opci6n OSI Transmiliendo Raclbiendo<br />

dOl6 Ver<br />

SW conlrol 1 00 99 99 O Ot<br />

dOl7 Tipo de Vanadorl 1001 9999 1<br />

dOl8 Tiempo de marcha 0 9999 H rs 1 10Hrs<br />

dOl9 Dato pt prueb OIFFFF 1 Hax<br />

d020 Ent ani 0 10 V O O tOO O 0 1<br />

d021 Ent ani 4 20 mAl 0 0100 0 0 1<br />

d022 IPotancia salidal 0 00 Alimentaci6nde 0 01 kW<br />

Variadorx 2<br />

d023 Cos Phi Salida 0 0 180 0 grados 0 1 grados<br />

d024 Temp variador 0 120 grados C 1 grado C<br />

d025 Estado Contador 09999 I<br />

d026 Estado Temponzl 0 0 9999 0 1 Sag<br />

d028 Estd paro 16gicol on I<br />

d029 Intensidad par O OO Intens var x 2 0 01 Amps<br />

QJ<br />

Puesta en Marcha Inteligente con Parametros de Grupo de<br />

Programaci6n Basica<br />

EI PowerFlex 40 esta diseiiado de manera que lapuesta en marcha sea simple y eficiente EI Grupo de<br />

Programaci6n contiene los parametros de uso mas frecuente<br />

Detenga el variador antes de camblar este para metro<br />

No Parametro I MinIMax PantallalOpclones Valor Predetermlnado<br />

P031 Voll placa motor 120NolIs nomin var lVCA Basado en la capacidad<br />

Q Seleccionar segun volt placa motor<br />

nominal del variador<br />

P032 Hzplaca motor 115 400 Hz 1 Hz 60Hz<br />

QJ Seleccionar segun la frecuencia Hz placa motor<br />

P033 Ilntens SC Motor lo o Intens saL var x 2<br />

Establecer a la maxima corrlente permislbledel molor<br />

0 1 Amps Basado en la capaddad<br />

nominal del variador<br />

P034 Frecuencla Mln 10 0 4000 Hz 0 1 Hz 0 0 Hz<br />

Establece Is mfnima frecuencia de saUda continua del<br />

varlador<br />

P035 Frecuencia Max 10 400 Hz I Hz 60 Hz<br />

QJ ESlablece la maxima lrecuencia de salida del variador<br />

P036 Fuente Arrenque 10 6 0 Teciado l11<br />

1<br />

0<br />

Establecee Q<br />

esquema de control Ulllizado para poner en<br />

1<br />

2<br />

3 Hilos<br />

2 Hilos<br />

marcha el variador<br />

3 Sens Niv2 W<br />

AI estar l<br />

actlva la tecla de relroceso<br />

4<br />

lambh n esla activa 5<br />

All VeI2 w<br />

Puerto Com<br />

a menos qua se Ie inhabilite por medio del A095 Inver<br />

Deshab<br />

6 AvlRet lJTlPur


Vea el Manual dal Usuario del PowerFlex40 en CD para oblener informaci6n sobre los paramelros Espaiiol 13<br />

Q Delanga el vanadOr anles da cambiar esle paramelro<br />

No Parametro I MinIMax PantallalOpclones Valor Predeterminado<br />

POO7 Modo da Paro 10 9 0 1<br />

Rampa Cp<br />

1 Inercia Cplll<br />

Modo de Paro activo para lodas ias fuenles de paro<br />

2 FrenoCC Cpll<br />

ejemplo ror lactado marcha de avance Terminal de EI 02<br />

3 FranAuloCC CPll<br />

marcha en reversa Terminal de E S 03puerlo RS485<br />

4 Rampa<br />

como S8 excepto indica a continuaci6n<br />

5 Inercia<br />

Importanla EI Terminalde E1S 01 esla siempre 6 Freno CC<br />

eslablecido para el para por inercia axceplo cuando P036<br />

Fuanla<br />

7 FrenAutCC<br />

Arranque esllleslablecido para conlrol de 3 hilos<br />

8 Rpa Fr M RsP<br />

Enel conlrol da Ires hilos el Terminal deE1S 01 eSla<br />

9 Rampa Fren M<br />

conlrolado por P037 Modo de Paro<br />

11 La enlrada de paro lambien borra el lallo<br />

P038 Referencia Veloc<br />

10 7 o Pal Va 0<br />

Establecela fuenle de referencia de velocidad para el<br />

variadar<br />

Importanle<br />

1<br />

2<br />

3<br />

Freclnterna<br />

Ent 0 1 OV<br />

Enlrada 4 20mA<br />

Cuando A051 0 A052 Sel ent diglx eslll<br />

configurado<br />

4 Frec presel<br />

en la opci6n 2 4 5 6 13614 Y la enlrada<br />

digital eSla aCliva A051 A052 A053 0 A054 anulara la<br />

referencia de velocidad indicada<br />

por este paramelro<br />

Consulla el Capitulo 1 del Manual del Usuariodel<br />

PowarFle 40 en el CD para oblener mas dalalles<br />

5<br />

6<br />

7<br />

Puarto Com<br />

Paro L6gico<br />

MultEnt Anf<br />

P039 Tiempo acal 1 10 0 600 0 Seg 0 1 Seg 10 0 Seg<br />

Eslablece el regimen de aceleraci6n para todos 105<br />

aumanlos de velacidad<br />

P040 Tiempodecel l 10 1 6oooSeg 0 1 Seg 10 0 Seg<br />

Estableca al regimen de deceleraci6n para todas las<br />

disminuciones de velocidad<br />

P041 IRestab a predel 10il o Uslo lnactv 0<br />

QJ Restablece todos108 parametros a sus valores<br />

predeterminados en fabrica<br />

1 Resl Fabnca<br />

P042 Clase lensi6n 1213 2 Tensi6n baja 480 V 3<br />

Q Ajusta la clase de lensi6nde 105 variado res de 600V<br />

3 TenSi6n alia 600 VI<br />

activo<br />

Parametros de Grupo Avanzados<br />

No Panlmetro MinIMax PantallaOpclones<br />

A051 Sel ent digl 1 0 26 0 No sa usa 13 EnICtrll0V 4<br />

Terminal de E1S 05 1 AcelIDecelZO 14 EntClrl20mA<br />

A052 Sel enl<br />

Terminalde digItS<br />

06<br />

2<br />

3<br />

Avanlimpuls<br />

Fallo Au<br />

15<br />

16<br />

Inhab PID<br />

Aum MOP<br />

4<br />

A053 Sel enl<br />

TerminaldiglJ de S 07<br />

4<br />

5<br />

Free presel<br />

Lacar<br />

17<br />

18<br />

Dismin MOP<br />

ArranqueTemp<br />

5<br />

A054 ISeL enl di91 6 Puerto Com 19 ActivConlad 11<br />

Q Terminal de S 08 7 Borrar Fallo 20 8 ParoRamp<br />

RestabTemp<br />

CP 21 ReslabConl<br />

9 Parolnercia CP 22 ResTempConl<br />

I A<br />

23<br />

24<br />

EnIL6gicl<br />

EnIL6gic2<br />

12 ImpulsRelroc 25 lImCle2<br />

26 Inver Anlg<br />

A055 Sel Sal Pulsos 0 22 o lislolFallo 11 EnIL6gicl 0<br />

1 EnFrecuencia 12 EnIL6gic2<br />

2 MolorMarcha 13 L6gica 1 y 2<br />

3 Retroceso 14 L6gica 1 6 2<br />

4 ml Sobrcarg 15 Paro L6g Sal<br />

5 Reg Ramp t 6 Temp Desacr<br />

6 Sabre Free 17 ContDesact<br />

7 Sobre Cle 18 Sabre PF Ang<br />

8 Sobre V CC 19 PerdEntAnlg<br />

O t i<br />

g V<br />

20<br />

21<br />

ContParam<br />

Faliono rec<br />

22 Clrt Freno M<br />

AOS6 Nivel Sal Pulsos 0 0 9999 0 1 0 0<br />

A05a Sel Sal<br />

gPlica 11 0 22 o listo Fallo 11 A061 Sel Sal plica<br />

EnlL6gicl 2<br />

2 1 EnFrecuencia 12 EnlL6gic2 1<br />

2 MolorMarcha 13 L6gica 1 y 2<br />

3 Retroceso 14 L6gica 1 6 2<br />

4 Sobrcarg mtr 15 Para L6g Sal<br />

5 Reg Ramp 16 Temp Desacf<br />

6 Sabre Free 17 Cont Desact<br />

7 Sobre Cle 18 Sobre PF Ang<br />

8 Sobre V CC<br />

r<br />

0 t i<br />

g<br />

6<br />

V 21 Falla no ree<br />

22 Clrl FrenoM<br />

0<br />

Valor<br />

Predetermlnado


Espaiol 14<br />

Vea<br />

No Para metro MinIMax PantallaOpclones<br />

el Menual del Usuario del PowerFlex40 en CD para oblener inlormad6n sobre los partlmetros<br />

A059 INvl sal 6ptica 1 0 019999 0 1 0 0<br />

A062 N sal6plica 2<br />

Confl9ureel6n A055 A05e y A061 MInIMax A0511 A059 Y A082<br />

6 0 400 Hz<br />

7 0I1eO<br />

e OIe15VoIIs<br />

10 01100<br />

16 O 1199911Se9<br />

17 119999Conleos<br />

18 111BOgrados<br />

20 Oil<br />

A064 L6giCa SIOplica 1013 II<br />

Opcl6n A064 L6gic Sal Oplical L6gie SaI Optica2<br />

0 NA Normalm nl Abl rto NA Norm lmenl Abi rto<br />

1 NC nl<br />

NormalC<br />

rrado NA Normalmenl Ablerto<br />

2 NA Normalmente Abierto NC Normalmente Corrado<br />

3 NC NormalmenleCerrado NC Normalmente Cerrado<br />

A065 Sel Sal Anlg 1 10 20 11 0<br />

Range de Valor minima Valor maximade saUda Posici6n<br />

OpciOn saUda desalida S I Anlg Max l Microinlerruplores DIP<br />

o FreeSal 010 O IOV OV OHz P035 Frecuencia Max o l0V<br />

1 CleSeI0 l0 O IOV OV OAmps 200 de amps nomlnales del variador o IOV<br />

2 TensSal 0 10 0 10V OV OVolIs 120 de la lensi6n de sa1ldenominal del variador O IOV<br />

3 PolSal 010 ol0V OV OkW 200 de polencia nominal del variador o IOV<br />

4 DalosPba 0 10 O IOV OV ooOO 65535 Hex FFFF O IOV<br />

5 FreeSal020 0 20 mA OmA OHz P035 Fraeu nda Max l 0 20 mA<br />

6 CleSal 0 20 o 20mA OmA OAmps 200 de amps nomlnales del variador o 20mA<br />

7 TensSal 0 20 0 20mA OmA OVollS 120 de IetensiOn de satida nominal del variador o 20mA<br />

e PoISalo20 o 20mA OmA OkW 200 de potencia nominal del variador o 2OmA<br />

9 DalosPba 0 20 o 20mA o mAc 0000 65535 Hex FFFF o 20mA<br />

10 FraeSaI4 20 4 20 mA 4mA OHz P035 Fracuencla Max o2OmA<br />

II Cl SaI4 20 4 20mA 4mA OAmps 200 de amps nomlnales del variador o2OmA<br />

12 TensSal 4 20 4 20mA 4mA OVolls 120 de la lensl6n de saJida nomInal del variador o20mA<br />

13 PoISaI4 20 4 20mA 4mA OkW 200 depOlencla nominal del varlador 0 20 mA<br />

14 DalosPba 4 20 4 20mA 4mA 0000 65535 Hex FFFF o 2OmA<br />

15 ParSal 0 10 0 10V OV OAmps 200 de amps nomlnales del varlador 0 10V<br />

16 ParSal 020 0 20 mA<br />

OmA<br />

OAmps 200 de amps nominales del variador o20mA 17 ParSa14 20 4 20mA 4mA OAmps 200 de<br />

amps nominales del varlador o 2OmA<br />

18 PlAjsl0 10 0 10V OV O Catibracl6n del punta de ajuste al100 0 Q10V<br />

19 PtAjslO 20 0 20 mA OmA O Calibracl6n del punto de aluste al1oo0 Q2OmA<br />

20 PlAjsl 420 4 20 mA 4mA O Callbracl6ndel punta de ajuste a11000 o20mA<br />

A066 Sal Anlg Max 0 800 1 100<br />

Valor<br />

predetermlnado<br />

A067 Tiempo acel 2 0 0 600 0 Seg 0 1 Seg 20 0 Sag<br />

A068 Tiempo decal 21 0 1 600 0 Sag O ISeg 20 0 Sag<br />

A069 Free Inlerna 0 0 400 0 Hz 0 1 Hz 60 0 Hz<br />

A070<br />

IFrec presel A071 Free presel101111 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

5 0 Hz<br />

A072<br />

A073<br />

Free presel<br />

IFrae 21<br />

10 Hz<br />

presel3<br />

20 0 Hz<br />

A074 Free 4 presel 30 0 Hz<br />

A075<br />

IFret presel<br />

A076<br />

A077<br />

Free presel6<br />

Free presel<br />

40 0 Hz<br />

50 0 Hz<br />

60 0 Hz<br />

1<br />

Pare aCllvar Free presel 0 establezca P038 ReferendaVeloe en la opcl6n 4<br />

Estadode enlrada Eslado de entrada Estado de entrada<br />

de En dlgll 1 de En digil 2 de En digit 3<br />

Terminal de EfS 05 Terminal d E1S 06 Terminal de E1S07<br />

Fuente do<br />

Freeueneia<br />

Parametro<br />

AcelJOeeel utlHzado 2<br />

1<br />

0 0 0 Free presalOI Tiempo aeal 11 deeel 1<br />

Tiempo<br />

0 0 Free presalll iempo acel 111 iempodecal 11<br />

I 0 0 Free prese12 iempo aceL 2J 1 llempodeeeL 2<br />

1 1 0 IFreepresal3 iempo acel 2J 1 1<br />

llempodecal 2<br />

0 0 jFreepresel4 iempoacel I 1 Tiempodecal I<br />

I 0 1 Free prasel 5 Tiempoacel 1 I Tlempodecel 1<br />

0 I I Free presel 61 iempo acel 211 llempodecal 2J<br />

I I I Free presal 71 Tiempe ac l 211i mp decal 2J<br />

2 Cuandouna entrada digilal sa eslableceen Ace2 y Decel 2 y la entrada asiA activa dicha entrada anulalos aJustes<br />

enestatabla<br />

A078 Freeuencla lesl 10 O Freeuencia Max 10 1 Hz 10 OHz<br />

0


Vea el Manual del Usuario del PowerFlex 40 en CD para oblener informaci6n sobre los parametros Espaiiol 15<br />

No Parametro MinIMax Pantalla Opciones<br />

A079 Impulsos AcolDec 0 1 600 0 Seg O 1Seg 10 0 Sag<br />

A080 Tiempo freno CC 0 0 99 9 Sag O 1Seg 0 0 Seg<br />

Una configuraci6n de99 9 Sag Conlinuo<br />

Valor<br />

Predeterminado<br />

A081 Nivellreno CC O OI lnlens var x 1 8 0 1 AmpS Ampsx 0 05<br />

A082 Sel resisfen FO 099 o Inhabililado 2 SinProtecci6n 0<br />

1 Res RA Normal 3 99 del Cicio de Trabajo<br />

Q<br />

A083 curva SI 0 100 1 0 Inhabilitado<br />

A084 Selec Refuerzo 0114 Ajustes en de tensi6n base 8<br />

Esta acl o unieamente cuando A125 Mod rend Parj 0 VlHz person<br />

esta estableddo en 0 VIHz Eal Yadable<br />

7 4 11 kW<br />

5 15 HP<br />

1 30 0 VI 5 0 0 no IR 10 10 0 cr<br />

2 35 0 VI 6 0 0 11 12 5 cr<br />

3 40 0 VI 7 2 5 cr 12 15 0 cr<br />

4 45 0 vr 8 5 0 cr 13 17 5 cr<br />

9 75 cr 14 20 0 cr<br />

A085 Refuer arranquel 10 0125 0 0 1 2 5<br />

Esla activo unieamenfec ando A084 Selec Refuerzo y A 125 Modo rend Pari eslan eslablecidos en 0<br />

A086 Tens ruptura 10 01100 0 0 1 25 0<br />

Esta activo unieamenlecuando A084ISelec Refuerzo y A125 Modo rend Par estan eslablecidos en 0<br />

A087 Free ruptural 10 0 400 0 Hz 10<br />

Hz 15 0 Hz<br />

Esla acl o unieamenlecuando A084 Selec Refuerzol y A125 Modo rend Par estan establecidos en 0<br />

A088 Tens 6n maxima 20Nolts nomin var 1 VCA Volts nomin var<br />

A089 rUm Corrienle 11 Oll lnlens var x 1 8 0 1 Amps Amps x 1<br />

A090 Selec SC Molor 012 o Sin Deselasificaei6n 1 Oesclasifieaci6n Mln 0<br />

2 Oesclasilieaci6n Max<br />

A091 Frecuencia PWMj 2 0 16 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Ilnl rearme aula 019 1<br />

A093 Relrd reinic aull 0 0 3000 Sag 0 1 Seg 1 0Seg<br />

A094 Inc al encender 0 1 o Inhabililado 1 Habililado 0<br />

Q<br />

A095 Inver Oeshab j 0 1 o Rev Hab litado 1 Rev Inhabililado 0<br />

Q<br />

A096 Acl mrch Vuelol 011 0 Inhabililado 1 Habilifado 0<br />

A097 Compensaci6n 013 o Inhabililado 2 Meeanieo 1<br />

1 Eleclrico 3 AmbOs<br />

A098 Oisparo Corr SW O O Inlens varx 2 0 1 Amps 0 0 Inhabililado<br />

A099 Faclor Proceso 0 11999 9 0 1 30 0<br />

A100 Borrar fallol 012 o lislonnactv 1 Reslablecor Fallo 0<br />

Q<br />

2 Borrar Buffer<br />

Al01 Bloqueo Programa 019999 o Oesbloqueado 1 Bloqueado 0<br />

Al02 Sel pIa Prueba 400IFFFF 1 Hex 400<br />

Al03 Vel datos Comj 015 0 1200 3 9600 3<br />

Es necesario<br />

1<br />

apagary encender Ja alimenlaei6n<br />

electriea del variador antes de que los eanibios afecten<br />

2400 4 19 21<br />

2 4800 el funeionamiento del variador<br />

5 38 41<br />

At04 Direc nodo coml 111247 1 100<br />

Es neeesario apagar y encender la a1imentaci6n<br />

eleelrica del variadorantes de que 105pamblos afeeten<br />

el funcionamien10 del variador<br />

Al05 IAcc perd comun 013 o Falla 2 Paro 0<br />

1 Avanee por inereia hasta 3 Continuar ultima veloeidad<br />

detenerse<br />

Al06 Tmp perd comun 0 1 60 0 Seg 0 1<br />

Al07 Formalo com 0 2<br />

l 0 RTU 8 N 3 RTU 8 N 2 0<br />

1<br />

Es neeesario apagaryencender la alimentaei6n<br />

RTU 8 E l electrica del variadorantes de que105 eambios<br />

2<br />

afecten<br />

RTU 8 0<br />

4 RTU aE 2<br />

1 el funeionamiento del variador<br />

5 RTU 8 0 2<br />

Al08 Idiomal 1110 1 Ingles 6 Reservado 1<br />

2 Franees 7 Portugues<br />

3 Espanol a Reservado<br />

4 Italiano 9 Reservado<br />

5 Aleman 10 Holandes<br />

Al09 Pisl Sal Anlg 0 0 100 0 0 1 0 0<br />

Al10 Lmlnl EnAn 0 1 OV 0 01100 0 0 1 0 0<br />

Q<br />

0<br />

5 0


Espafiol 16 Vea el Manual del Usuario del PowerFlex 40 en CO para oblener Informa 6n sabre los perAmelros<br />

No Parametro MInIMax PantallalOpelones<br />

Alll LmSup EnAn 0 10V 0 0100 0 0 1 100 0<br />

QJ<br />

Al12 Lmln EnAn 4 20 mAl 0 0 100 0 0 1 0 0<br />

Q<br />

A113 ILmSp EnAn 4 20 mAl 0 0 100 0 0 1 100 0<br />

Q<br />

A114 Deslz Hertz @ In 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

Al15 rpo Min Proees 0 00 99 99 0 01 0 00<br />

A116 rpo Max Procesl 0 00 99 99 0 01 0 00<br />

Al17 Reg bus modo 0 1 O InhabililadO 1 Habilitado I<br />

Vator<br />

Predetermlnado<br />

A118 rUm Corrienle 2 O I lntens var x 1 8 0 1 Amps Amps x 1 5<br />

A119 Free sallol 0 400 Hz 1 Hz OHz<br />

A120 Int free sallo 0 0 30 0 Hz 0 1 Hz 0 0 Hz<br />

A121 rmpo Fallo Parol 05 o 60 Segundos 3 360Segundos 0<br />

1<br />

2<br />

120 Segundos<br />

240 Segundos<br />

oSI R O<br />

A122 perd enl enal6g 0 6 o Inhabllilaclo 4 Ref Free Mln 0<br />

1 Fallo F29 5 Ref Free Max<br />

2 Paro 6 Ref Free Inr<br />

3 Ref Cere<br />

A123 10 V Bipolar Habj 0 1 o Uni PolarAdiv 1 BI Polar Aetiv 0<br />

A124 IPWM Var Inhab 01 O Habilitado 1 Inhabililado 0<br />

A125 Modo rend Per 0 1 O VlHz 1<br />

Vecl sin enc 1<br />

AI26 Ampsplaca mOlorl O I lntens var x 2 0 1 Amps Inlens sal Jar<br />

AI27 Auloajuste 0 2 O Uslollnactv 2 Aiusle Rotac 0<br />

1 Aluste ESIAlieo<br />

A128 Celda Volls IR 0 0 2300 V CA 0 1 VCA Volls nomin var<br />

A129 IRel Inlens nuj O OO VolI place motor 0 01 Amps Intens sal var<br />

A130 ILmSup ejusle PID 0 0 4000 0 1 60 0<br />

A131 Lmlnfejusle PID 0 0 400 0 0 1 0 0<br />

A132 Sel Ref PID 0 8 0 PID Inhab 5 Consigna Aiuste 0<br />

1 Conslgna PID 6 0 1 OV Ajusle<br />

2 Ent 0 10V 7 4 20mA Ajusle<br />

3 Ent 4 20mA 8 ComOn Ajusle<br />

4 Puerlo Com<br />

A133 Sel realimnl PID 0 2 0 Enl 0 10V 2 Puerto Com 0<br />

1 EnI4 20mA<br />

A134 Gan prop PIDI 0 00 99 99 01 0 01<br />

AI35 liempo Inleg PID 0 0 999 9 Sag 0 1 2 0<br />

A136 Vel Dif PIDj 0 00 99 99 l Sag 0 01 0 00<br />

A137 Conslgna PID 0 0 100 0 0 1 00<br />

A138 Banda muerl PID O O tO O 0 1 0 0<br />

A139 lprecarga PID 0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A140 pare L6gico 0 7 00Ol bAFF 4Dlgllos OOFI<br />

A147<br />

U d t xOfgi e<br />

variador<br />

BIt in<br />

e<br />

tnual<br />

A150 rmpo Paro Lege 0 7 0 0 9999 Sag 0 1 Seg 30 0 Sag<br />

A157<br />

A160 Ret Des FrenoM 0 01 10 00 Seg 0 01 Seg 2 00 Sag<br />

A161 Ret Con FrenoM 0 01 10 00 Seg 0 01 Seg 2 00 Sag<br />

AI62 SeIMod Res MOPI 0 1 o Inic MOP 0 1 Greb VaI MOP 1


C6digos de Fallo<br />

Para barrar un falla pulse la teCla Paro apague y encienda la alimerttaci6n<br />

ele trica 0 establezcaAIDO Borrar Falla en I 62<br />

No Falla Desc rlpci6n<br />

F2 Entrada auxiliarll Verifique el cableado remolo<br />

Espariol 17<br />

F3 Perdida alim Supervise la linea de CA entrante para detectar baja tensi6n 0 interrupciones en la linea de palencia<br />

I<br />

F4 Baja Tensi6n<br />

Supervise la linea de CA entrante para detectar baja tension 0 interrupciones en la Ifnea de polencia<br />

F5 Sobrelensi6n W Supervise la Hnea de CA para verifiear si existe obretensi6n 0 condiciones lransilorias La sobretensi6ndel<br />

bus tamblen puedeser ocasionada por la regeneraci6n del motor Prolongueel tiempo de deceleraci6n 0<br />

instale una opci6n de frenadodinamico<br />

F6 Motor paradol11 Aumente Tiempo acelXl 0 r duzca la carga para que la corriente de salida del variador no exceda la<br />

comenle establedda par el para metro A089 limo Corriente 11<br />

111<br />

F7 Sobrecargadel Motor<br />

Existe una carga de motor excesiva Reduzca la carga ara que la corrien e de salida del variador no exceda<br />

la corrienle eslablecida por el parametro P033 Intens C Motor<br />

F8 Sobrtmp Rad 1 Verifiqueque no haya alalas bloqueadas0 sucias en el disipador de calor Verifique que la temperatura<br />

ambienteno haya excedido 40 C 104 F para inslala ones IP 30INEMA1<br />

UL Tipo 10 50 C 122 F para<br />

lnslalaciones de tip6 abierto<br />

Verifiqueel vantilador<br />

F12 Sobrcorr HW Verifiquela programaci6n Verffique que no haya exceso de cargal ajusles err6neos de ee tensi6ndefrenado<br />

de CC muyelevada U olras causas de exceso de corriente<br />

F13 Fallotierra Verilique el motor y el cableado externo de los lerminales de salida del variador para una co dici6n de puesta<br />

stiena<br />

F29 Perdida Entreda Anal6gica II Una entrada anal6giea asIa configurada para fallar cuando sa interrumpa la senal Ocurri6 una perdida de<br />

senal<br />

F33 lnt rearma auto Corrija la causa del fallo y borre manualmenle<br />

F38 Fase U a tierra Verifique el cableado entre el variadory el motor Verifique que no exista en el motor una lasea tierra<br />

F39 Fase V atierra<br />

Si no se puede borrar el faUo reemplaee el variador<br />

F40 Fase W a tierra<br />

F41 Fase UV corto Verifique que no exista una eondici6n de cortocireuito en el cableado del motor ni en el de salida del variador<br />

F42 Fase UW corto<br />

Si no se puede borrar el fallo reemplace el variador<br />

F43 Fase VW corto<br />

F48 Param predel EI variador recibi6 instrueciones para eseribir los valores predeterminados en el EEPROM Borre el fallo 0<br />

apague y encienda el variador Programe los parametros del variador segun seanecesario<br />

F63 Sobrcorr SWIl Venfique ios requisitos de carga y el vaiorA098 Disparo Corr SWJ<br />

F64 Sobrcrg vanad Reduzca la carga 0prolongue el Tiempo de aeeleraci6n<br />

F70 Unidad pol Apague y eneienda la unidad Si no se puede bOITar el faHo reemplace el variador<br />

F71 Perdida Red Fail6 ia redde comunicaci6n<br />

F80 Autoajusle SVC Ei usuario cancel61a fund6n de autoajuste 0 fail6 ia funci6n<br />

F81 Perdida comun 5i el adaptador no se desconect6 intencionalmente verifique el cableado alpuerto Reemplace al cableado el<br />

expansor de puerto los adaptadores 0todo al variador segun sa requiera Verifique la conexi6n Sa<br />

descoriect6 inte cionalmenta Un adaptador Apague la unidad por medio de A105 Ace perd comunk<br />

F100 Suma deverificaci6n de<br />

parametros<br />

Restaure los valores predeterminados en la fabrica<br />

F122 Failode ta eta de ElS Apague y encienda la unidad Si no sa puede borrar el fallo reemplace el variad6r<br />

I<br />

Fallo de tipo Auto Restab Marcha Configurar conparametros A092 y A093


Espaiiol 18<br />

Oimensiones del Variador<br />

Capacidades Nominales de los Bastidores del PowerFlex 40 Se indican en kW y en HP<br />

Bastldor 120 V CA MonofBslco 240V CA Monofaslco 240 V CA Trifaslco 480 v CA Trlfaslco 600V CA Trifaslco<br />

B 04 0 5 04 0 5 04 0 5 2 04 0 5 2<br />

0 75 1 0 4 0 5 0<br />

075 10 075 1 0 075 10 37 5 0 0 75 1 0 4 0 5 0 1<br />

1 15 15 2 0 1 5 2 0 1 5 2 0 2 2 3 0<br />

C 2 2 3 0 5 5 55 5 110 15 0 5 5 110 15 0<br />

7 517 5 10 0 7 5 IT10 0 7 517 5 10 0<br />

I<br />

Al<br />

Variador de Velocidad de CA PowerFlex 40<br />

ij<br />

1 F<br />

U<br />

21301<br />

213 01<br />

5fOl<br />

Las dimensiones se muestran en milfmetros y pulgadas<br />

Los pesos se indican en kilogramos y en Iibras<br />

l<br />

1ii<br />

Peso de<br />

l A B C 0 E F Envlo<br />

B 100 160 136 67 166 67 4 2 2<br />

3 94 709 5 35 3 43 6 61 3 44 4 9<br />

C 130 260 160 116 246 4 3<br />

5 1 10 2 7 1 4 57 97 9 5<br />

Comunlcaci6n Filtro RFI IP 30INEMA 1 Juegos de Opciones UL Tipo 1<br />

m<br />

m<br />

o m<br />

5<br />

OJ<br />

c<br />

Varlador de Varlador de<br />

Opel6n Bastldor B Bastldor C<br />

A Cublerta cornun 25 0 96 25 0 96<br />

B Flitro EMC en linea 50 1 97 60 2 36<br />

C Flilro EMC en Ilnee 229 9 02 309 12 17<br />

o IP 30INEMA 1UL Tipo 1 33 1 30 60 2 36<br />

IP30 NEMA 1UL Tlpo 1<br />

para 18 cubierta comun<br />

64 2 52 60 2 36<br />

Bastldor B 22 JBAB<br />

Bastldor B 22 JBCB<br />

Se usa con la cublerte comun<br />

Bastldor C 22 JBAC<br />

Bastldor C 22 JBCC<br />

Seusa conla cubierta comOn<br />

0222<br />

U S AllenBradley Drives Technical Support<br />

Tel 1 262 512 6176 Fa 1 262 512 2222 Emall suppon@dnves ra rockwell com Online www ab comlsupporVabdr1ves<br />

Publicaci6n 22B QS001 B ES P Enero del 2004<br />

Rockwell<br />

Automation<br />

Reemptaza 18 publicacl6n de octubre del 2002 Copyright C 2004 Rockwell Automation Inc Reservados todos los derechos lmpreso enTwn<br />

0 e7


tml<br />

llV<br />

PowerFlex 40<br />

AC drive<br />

FRN 2 xx<br />

Snel aan de slag<br />

In deze handleiding Snel aan de slag worden de basisstappen samengevat die<br />

nodig zijn om de PowerFlex 40 AC drive te installeren op te starten en te<br />

programmeren De verschafte informatie vervangt de gebruikershandleiding<br />

niet en is uitsluitend bedoeld voor bevoegd personeel dat onderhoud aan<br />

drives uitvoert<br />

Raadpleeg voor uitgebreide informatieover de PowerFlex 40 waaronder<br />

EMC instructies overwegingen m b t de toepassing en aanverwante<br />

voorzorgsmaatregelen de Gebruikershandleiding van de PowerFlex 40<br />

publicatie 22B<br />

wwwab com manuals dr<br />

Algemene voorzorgsmaatregelen<br />

op<br />

UMOOl<br />

de cd die bij de drive wordt geleverd of ga naar<br />

OPGELET De drive bevat hoogspanningscondensators die tijd nodig hebben<br />

omte ontladen nadat de netvoeding is verwijderd Verzeker u ervan dat de<br />

netvoeding vande lijningangen R S T Ll L2 L3 ge isoleerd is voordat u<br />

aan de drive werkt Wacht drie minuten zodat de condensators tot veilige<br />

spanningsniveaus zijn ontladen Hetnalaten hiervan kan emstig of dodelijk<br />

letsel tot gevOlg hebben<br />

Niet brandende LED s op het display betekenen niet dat de condensators tot<br />

veilige spanningsniveaus ontladen zijn<br />

OPGELET Schade aan de apparatuur en of lichamelijk letsel kunnen ontstaan<br />

als parameter A092 Poging aut hstrt of A094 Start bij powrup in een<br />

ongeschikte toe passing wordt gebruikt Gebruik deze functie niet lOnder van<br />

toepassing zijnde plaatselijke en landelijke voorschriften normen en<br />

industrierichtlijnen in acht te nemen<br />

OPGELET Uitsluitend bevoegd personeel dat vertrouwd is met AC drives en<br />

de bijbehorende apparatuur mag de installatie het opstarten en het verdere<br />

onderhoud vanhet systeem plannen of uitvoeren Het nalaten hiervan kan<br />

lichamelijk letsel en of schade aan de apparatuur tot gevolg hebben<br />

OPGELET Deze drive bevat onderdelen en samenstellen die gevoeiig zijn<br />

voor ESD elektrostatische ontlading VoorlOrgsmaatregelen voor het<br />

tegengaan vanstatische elektriciteit zijn nodig wanneer dit toestel wordt<br />

ge installeerd getest of gerepareerd of wanneer eronderhoud aan wordt<br />

uitgevoerd Componenten kunnen beschadigd raken als de procedures voor het<br />

tegengaan van statischeelektriciteit niet worden opgevolgd Als u niet vertrouwd<br />

bent met de procedures voorhet van tegengaan statische elektriciteit<br />

raadpleeg<br />

dan de publicatie 8000 4 5 2 Guarding Against Electrostatic<br />

Damage<br />

Beveiliging tegen elektrostatische schade vanAllen Bradley of een ander<br />

toepasselijk handboek overhet van tegengaan statischeelektriciteit<br />

OPGELET Eenonjuist toegepaste of ge<br />

installeerde drive kan schade aan<br />

componenten of een verkorting van de levensduur van het product tot gevolg<br />

hebben Bedradings of toepassingsfouten lOals een te klein<br />

gedimensioneerde<br />

motor onjuiste ofonvoldoende ACvoeding of extreme omgevingstemperaturen<br />

kunnen<br />

storingen in het systeem tot gevolg hebben


Nederlands 2<br />

Overwegingen<br />

m btmontage<br />

Monteer de drive rechtop op een vlak verticaal oppervlak<br />

Frame Schroefmaat Schroefkoppel DIN rail<br />

B M4 m 8 32 1 56 1 96 N m 35mm<br />

C M5 nr 10 24 245 2 94 N m<br />

Beschenn de koelventilator door stof of metalen deeltjes te vermijden<br />

Stel hem niet bloot aan een corrosieve omgeving<br />

Bescherm hem tegen vocht en direct zonlicht<br />

Minimale tussenruimte voor montage<br />

Zie biz 16 voor montageafrnetingen<br />

V 0 1V 0 1<br />

120 mm<br />

odobo odobo<br />

epoo epoo<br />

0 0<br />

120mm<br />

I<br />

0 0<br />

1r l11 1<br />

MontageoPtie A<br />

Geen ruimte nodig tussen<br />

dflves<br />

Montageoptie B<br />

Omgevingsbedrijfstemperaturen<br />

l<br />

o<br />

odobo<br />

epoo<br />

25 mm<br />

1 V 0 1<br />

0 0<br />

120mm<br />

odobo<br />

epoo<br />

o 0<br />

120mm<br />

I I Ir JI<br />

Omgevingstemperatuur Nominale waarden van Minimale tussenruimte voor<br />

Minimaal Maxirnaal behuizing montage<br />

IP 2010pen type<br />

Gebruik montageoptie A<br />

40 C<br />

10 C IP 30 NEMA l UL type 1 1 Gebruik montageoptie B<br />

50 C IP 2010pen type Gebruik montageoptie B<br />

1 Nominale waarden vereisen installatie van de optieset IP 30 NEMA 1 UL type 1 van de<br />

PowerFlex 40<br />

Algemene aardingseisen<br />

CE conformiteit<br />

Belangriik Verwijder de doorverbinding tussen de MOV en de aarde<br />

als de drive op een ongeaard distributiesysteem wordt geinstalleerd<br />

Draai de schroef vast na het verwijderen van de doorverbinding<br />

Raadpleeg de Gebruikershandleiding van de PowerFlex 40 op de bij de drive<br />

geleverde cd voordetails overde wijze waarop u aan de Jaagspanningsrichtlijn en<br />

de EMC richtlijn elektromagnetische compatibiIiteit moetvoJdoen


Specificaties zekeringen en stroomonderbrekers<br />

Nominale waarden van drives<br />

Catalogus<br />

nummer<br />

Nomlnale waarden<br />

uitgeng<br />

kW<br />

100 120 VAC 10 1 lase ingang 0 230 V 3 lase uitgang<br />

Nominale waai den ingang Aftakclrcuitbevelliging<br />

Nederlands 3<br />

Vermogens<br />

dissipatle<br />

Magneet IP20 open<br />

schakelaars W<br />

22B V2P3Nl04 0 4 2 3 90 132 1 15 9 0 15 140M C2E C16 100C12 30<br />

22B V5PON104 0 75 5 0 90 132 2 45 20 3 35 140M D8E C20 100 C23 56<br />

22B V6PON104 1 1 6 0 90 132 3 0 24 0 40 140M F8E C32 100 C37 70<br />

200 240VAC 10 1 lase l<br />

Ingan9 0 230 V 3 lase uitgang<br />

22B A2P3Nl04 0 4 2 3 180264 1 15 6 0 10 140M C2E B63 100 C09 30<br />

22B A5PON104 0 75 5 0 180264 2 45 120 20 140M C2E C16 100C12 55<br />

22B A8PON104 1 5 8 0 180 264 4 0 180 30 140M D8E C20 100C23 80<br />

22B A012Nl04 2 2 12 0 180 264 5 5 25 0 40 140M F8E C32 100C37 110<br />

200 240 VAC 10 3 lase Ingang 0 230 V 3 fase ultgang<br />

22B B2P3Nl04 0 4 2 3 180264 1 15 2 5 6 140M C2E B40 1 OO CD7 30<br />

22B B5PON104 0 75 5 0 180 264 2 45 5 7 10 140M C2E Cl0 00C09 55<br />

22B B8PON104 1 5 8 0 180 264 4 0 9 5 15 140M C2E C16 100C12 80<br />

22B B012Nl04 2 2 12 0 180 264 5 5 15 5 25 140M C2E C16 100 C23 115<br />

22B B017Nl04 3 7 17 5 180 264 8 6 21 0 35 140M F8E C25 100 C23 165<br />

22B B024Nl04 5 5 24 0 180 264 1 1 8 26 1 40 140M F8E C32 100C37 226<br />

22B B033Nl04 7 5 33 0 180 264 16 3 34 6 60 140M G8E C45 100C60 290<br />

380 480 VAC 10 3 lase Ingeng 0 460 V3 lase uitgang<br />

22B D1P4Nl04 0 4 1 4 342 528 1 4 1 8 3 140M C2E B25 100 C07 30<br />

22B D2P3N 1 04 0 75 2 3 342 528 2 3 3 2 6 140M C2E B40 100 C07 40<br />

22B D4PON104 1 5 4 0 342 528 4 0 5 1 10 140M C2E B63 100 C09 60<br />

22B D6PON104 2 2 6 0 342 528 5 9 7 5 15 140M C2E Cl0 100C09 90<br />

22B D010Nl04 4 0 10 5 342 528 10 3 13 0 20 140M C2E CI6 100C23 150<br />

22B D012Nl04 5 5 12 0 342 528 11 8 14 2 25 140M D8E C20 100C23 160<br />

22B D017Nl04 7 5 17 0 342 528 16 8 18 4 30 140M D8E C20 100C23 200<br />

22B D024Nl04 11 0 24 0 342 528<br />

460 600VAC 10 3 lase ingang 0 575 V 3fase uitgang<br />

234 26 0 50 140M F8E C32 100C43 285<br />

22B E1P7Nl04 0 75 1 7 414 660 2 1 2 3 6 140M C2E B25 1000C09 40<br />

22B E3PON104 1 5 3 0 414 660 3 65 3 8 6 140M C2E B40 1 OO C09 60<br />

22B E4P2Nl04 2 2 4 2 414660 5 2 5 3 10 140M C2E B63 100 C09 90<br />

22B E6P6N 104 4 0 6 6 414 660 8 1 8 3 15 140M C2E Cl0 100 C09 150<br />

22B E9P9Nl04 5 5 9 9 414 660 12 1 11 2 20 140M C2E C16 l00C16 160<br />

22B E012Nl04 7 5 12 2 414 660 14 9 13 7 25 140M C2E C16 l00C23 200<br />

22B E019Nl04 11 0 19 0 414 660 23 1 24 1 40 140M D8E C25 100C30 285<br />

1<br />

200 240 VAC I fase drivesziin ook verkrijgbaar met een integraal EMC filter Het achtervoegsel van de catalogus<br />

verandert van 2<br />

Nl04 in N114<br />

Raadpleeg de keuzegids Bulletin 140M motorbeveiligingen publicatie 140M SGOOI<br />

uilschakelvermogen te bepalen die voor uw toepassing vereist zijn<br />

om het frame en


Nederlands 4<br />

Programmeerbere uitgeng C vorm releis<br />

Nomlnale weerstendswaarden 3 0 A bij 30 VDC 3 0 A bij 125 VAC 3 0 A bij 240 VAC<br />

Nomlnalelnductiewaarden 0 5 A bij 30 VDC 0 5 A bij 125 VAC 0 5 A bij 240 VAC<br />

Zekeringen en stroomonderbrekers<br />

Aanbevolen zekeringtype UL klasse J CC T of type BS88 600 V 1550 V of gelijkwaardlg<br />

Aanbevolen stroomonderbrekers HMCP stroomonderbrekers of gelijkwaardig<br />

Beveiligingsfuncties<br />

@YULSOBC c@yCSA22l C<br />

EMC 01 89 6<br />

LV EN50178 EN60204<br />

EMC EN 618tJ03EN50081 1 EN 50082 2<br />

Opto uitgangen<br />

30 VDC 50mA<br />

Inductievrij<br />

M rbevelliging 12t o erbelestingsbe elllging 150 oor 60 see 200 oor 3 see ersella beveiliging klas 1 D<br />

Overs room 200 grens van hardware 300 onmiddellljke stonng<br />

1ge1ijkwaerdlg<br />

Analoge ultgangen 10 bit<br />

Minlmaal 0 10 V 1 kOhm<br />

Maximaal 4 20 mA 525 Ohm<br />

Tehoge spanning 1 00120 VAC ingang Uitsellakeling treedt op bij 405 VDC busspanning<br />

aan 150 VAC binnenkomende<br />

200 240VAC Ingang Uitschakeling treedt op bii 405 VDC busspanning gelijkwaardig aan 290VAC binnenkomende Ii n<br />

380 460 VAC ingang Uitsellakeling treedt op bil810 VDC busspanning gelijkwaerdig Ban 575VAC binnenkomende Ii n<br />

460 600 VAC ingeng Uitsellakeling treedt op bij 1005 VDCbusspanning gelijkwaerdig aan 711 VAC binnenkomende lijn<br />

Telage spanning 100 120 VAC ingang Uitschekeling treedt op bij 210VDC busspanning ean 75 VAC binnenkomendelijn<br />

200240 VAC ingang Uitschakeling treedt op bij 210VDC 380 480<br />

busspanning Ban 150VAC binnenkomende<br />

liinl<br />

VAC ingang Uitschekeling treedt op bij 390VDC busspanning Ban275 VAC binnenkomende liln<br />

46O lOO VAC ingang Als ullschakeling P042 3 Hoogspanning optreedt VDC busspanning 344VAC binnenkomande lijn<br />

Als uitschakeling P042 2 laagspanning optreedt bij 390 VDCbusspanning 275 VAC binnenkomende tijn<br />

Spanningsdip overbrugglng Mlnimele overbrugging is0 5 see gangbare waarde 2 see<br />

S oringvrije overbrugglng voeding 100 mlllisec<br />

Dynamische rem<br />

In usief interne rem IGBT met aile nominale waerden Raedpleeg Bijlage B van de Gebrulkershandleiding van de PowerFlex40 op cd voor<br />

informatie overhet bestellen van een DB weerstand<br />

lij nl


Sterkstroombedradin9<br />

Nominale waarden sterkslroombedrading<br />

Niet afgeschermd 600 V 75 C THHNfTHWN<br />

Afgeschermd 600 V 75 C of gO c RHH RHW 2<br />

Afgeschermde goot nominaal 600 V 75 c of 90 c RHHlRHW 2<br />

Terminal 1<br />

Beschrijving<br />

All 1 S L2 1 lase ingang<br />

AIL 1 S L2 T L3 3 fase ingang<br />

Nederlands S<br />

Aanbevolen koperdraad<br />

15 mil geisoleerd droge plaats<br />

Anixter OlF 7xxxxx<br />

Belden 29501 29507 of<br />

gelijkwaardig<br />

Anixter 7V 7xxxx 3G<br />

Shawflex 2ACD 3ACD of<br />

gelijkwaardig<br />

UfT1 Naar motor UfT1<br />

Verwissel twee<br />

YfT2 Naar motor VfT2 willekeurige motordraden<br />

om de voorwaartse<br />

WfT3 Naar motor WfT3 richting te veranderen<br />

P2 PI<br />

DC DC Aansluiting DC bus<br />

OW<br />

Aansluiting DC bus inductor alleen drives met frame C<br />

De drive met frame C wordt geleverd met een doorverbinding tussen<br />

aansluitterminals P2 en Pl Verwijder deze doorverbinding alleen<br />

wanneer een DC bus inductor wordt aangesloten De drive wordt<br />

alleen ingeschakeld als een doorverbinding of inductor is aangesloten<br />

BR BR Aansluiting weerstand dynamische rem<br />

@ Veiligheidsaarding PE<br />

1<br />

Belangrijk Schroeven van aansluitterminals kunnen tijdens ve oerlosraken Verzeker u ervan dat<br />

aile schroeven van aansluitterminals tot het aanbevOlen koppel zijn vastgedraaid voordat u de<br />

voeding naar de drive inschakelt<br />

Specificaties voedingsaansluitterminal<br />

Frame Maximale draaddikte 2 Minimale draaddikte 2<br />

Koppel<br />

B 5 3 mm2 1 3mm2 1 7 2 2 N m<br />

C 8 4 mm2 1 3mm2 2 9 3 7 N m<br />

2 Maximale minimale dikten die de aansluitterminal accepteert dit zijn geen aanbevelingen


Nederlands 6<br />

In9an9svermogencondities<br />

Ingangsvermogenconditie Oplosslng<br />

Te lage lijnimpedantie minder dan 1 lijnreactantie Installeer lijnreacto 1<br />

Voedingstransformator groter dan 120 kVA<br />

De Iijn heeft condensators voor cos phi compensatie<br />

De voeding van de lijn wordt vaak onderbroken<br />

De lijn heeft intermitterende ruispieken van meer dan<br />

6000 V bliksem<br />

of scheidingstransformator<br />

of bus inductor alleen 5 5 11 kW<br />

drives<br />

Installeer Iijnreactor<br />

of scheidingstransformator<br />

De fasespanning naar aarde overschrijdt 125 van Verwijder MOV doorverblnding naar<br />

normale tweefasespanning<br />

aarde<br />

of installeer zo nodig<br />

Ongeaard distributiesysteem<br />

scheidingstransformator met<br />

geaard secundair<br />

240 V open driehoekconfiguratie<br />

Installeer lijnreactor<br />

1 Raadpleeg Bijlage B van de Gebruikershandleiding van de PowerFlex 40 op cd voorinformatle over<br />

het bestellen van accessoires<br />

Aanbevelingen voor IO bedrading 2<br />

Draadtype n Beschrijving Mlnimale isolatie<br />

Belden 8760 9460<br />

of gelijkw<br />

Belden 8770<br />

0 8 mm2 getwist aderpaar 100 afgeschermd<br />

met afvoer<br />

0 8 mm2 3 aderig alleen afgeschermd<br />

300 V<br />

Voor<br />

60 graden C<br />

of gelijkw<br />

potentiometer op afstand<br />

2 Als de draden kort zijn en binnen een kast worden gehouden waar zich geen gevoelige circuits<br />

bevinden hoeft afgeschermde draad niet noodzakelijkerwijs te worden gebruikt maar dit wordt altijd<br />

aanbevolen<br />

Specificaties IO aansluitterminal<br />

Frame<br />

Maximale draaddikte 3<br />

Minimale draaddikte 3<br />

Koppel<br />

B en C 1 3 mm2 0 13 mm2 05 0 8 N m<br />

3 Maximum minimum dat de aansluitterminal accepteert dit zijn geen aanbevelingen<br />

Raadpleeg de Gebruikershandleiding van de PowerFlex 40 op cd voor<br />

aanbevelingen voor maximale lengte voor sterkstroom en stuurstroomkabels


Relais N O<br />

Relais common<br />

Relais NC<br />

Besturingsaansluitterminal<br />

Aansluitschema stuurstroombedradin9<br />

Vrijgave 4<br />

doorverbinding<br />

R1<br />

R2<br />

R3<br />

I 0<br />

I<br />

f8l<br />

VO 20 mAlJ V<br />

R1 R2 R3<br />

30VDC<br />

50mA<br />

Inductievrij<br />

Sel anal uitgang<br />

01 02 03<br />

lCID CID 8 1l CIDrl SRC<br />

30 VDC 125 VAC 240 VAC<br />

Weersland 3 0A 3 0 A 30A<br />

1<br />

Inductie 0 5 A 05 A 05A<br />

24 V<br />

109<br />

Belangrijk I O aansluitterminal 01 is altijd een ingang In<br />

vrijloop tot stilstand behalve wanneer P036 Bron Starten<br />

op 3 draads besturing is ingesteld In 3 draads besturing<br />

wordt IO aansluitterminal 01 bestuurd door P037<br />

Stop mode Aile andere stopbronnen worden bestuurd<br />

door P037 Stopmode<br />

1<br />

Stoppen<br />

GanRbare S C<br />

1 01<br />

bedrading<br />

W<br />

2<br />

StertenIVOORUIT dreaien<br />

02<br />

03<br />

04<br />

05<br />

06<br />

07<br />

08<br />

09<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

RichtingfACHTERUIT dra<br />

Digitaal common<br />

Diging 1<br />

Dig ing 2<br />

Dig ing 3<br />

Dig ing 4<br />

Opto common<br />

24 VDC<br />

10VOC<br />

0 10V of 10VI ingang<br />

Analoog common<br />

4 20 mA ing<br />

Anal uitgang<br />

Opto uitg 1<br />

Optouil 2<br />

19 RS485 IDSI afscherming<br />

13 14 15 16 17 18 1<br />

jjjjCID CID CID CID CID CID CID<br />

I<br />

I I<br />

I<br />

I<br />

Nederlands 7<br />

Pot moet min<br />

1 10 kOhm<br />

2 Watt zijn<br />

Common<br />

Belangrijk De drive wordt geleverd met een doorverbinding<br />

ge<br />

installeerd tussen IO aansluiUerminals 01 en 11<br />

Verwijder deze doorverbinding wanneer u I O aansluitterminal 01 als een stop of vrijgave ingang gebruikt<br />

2 Tweedraads besturing afgebeeld Gebruik voor driedraads besturing een kortstondige ingang op I O<br />

3<br />

024V<br />

P036 Bron Start n Stoppen 110 aanslulttenninal<br />

01 Stoppen<br />

Toelsenbord d m v P037 Vrijloop<br />

3draads dmv P03 dmv P037<br />

2 draads d mv P037 Vrijloop<br />

RS4e5 poort d m v pa3 Vrij oop<br />

aansluitterminal 02 om een startopdracht te geven Gebruik een vaste ingang cYo voor I O aansluitterminal 03<br />

om de draairichting te veranderen<br />

3 Wanneer u een opto uitgang met een inductiebelasting zoals een relais gebruikt moet u een hersteldiode<br />

parallel aan het relais installeren zoals afgebeeld om schade aan de uitgang te voorkomen<br />

4 Wanneer de VRIJGAVE doorverbinding wordt verwijderd zall O aansluitterminal 01 altijd als een vrijgave van<br />

hardware optreden en een In vrijloop tot stilstand veroorzaken Raadpleeg de Gebruikershandleiding van de<br />

PowerFlex 40 op cd voor meer informatie


Nederlands 8<br />

Besturings I O aansluitterminalbenamingen<br />

Nr Signaal Default Beschrijving Param<br />

R1 Relais N O Fout Normaal open contact vooruit9angsrelais A055<br />

R2 Relais common Common voor uitgangsreleis<br />

R3 Relais NC Fout Normaal gesloten contact voor uitgangsrelais A055<br />

Sel analuit9ang<br />

OIP schakelaar<br />

Sink Source<br />

OIP schakelaar<br />

01 Stoppen l<br />

0 10V<br />

Source SRC<br />

Stell de analoge uitgang op spanning of stroom in Instelling moet<br />

overeenstemmen met A065 iSel anal uitgl<br />

Ingangen kunnen via de OIP schakelaarinstelling als Sink SNK of Source<br />

SRC worden bedraed<br />

Vnjloop Om de dnveIe kunnen starten moet een op de fabnek P036 1<br />

geinstalleerde doorverbindin9 of een normaal gesloten ingang<br />

aanwezig zijn<br />

02 StartenNOORUIT Niet actief Opdracht komt als default vanhet integrale toetsenbord Zie<br />

draaien<br />

03 RichtingACHTERUIT Niet actief<br />

draaien<br />

voorhet uitschakelen vanachterwaartse bediening A095<br />

P036 P037<br />

Achteruit uitl P036 P037<br />

04 Oigitaal common Voor di9itale ingangen Elektronisch geisoleerd met digitale<br />

ingangen van analoge 1 0 en opto ult9angen<br />

05 Oig ing 1 Preset freq Programmaer met A051 Sel digit ing 11 A051<br />

06 Oig ing 2 Preset freq programmeer met A052 Sel digit in9 2J A052<br />

07 Di9 ing 3 Lokaal programmeer met A053 Sel digit in9 3 A053<br />

08 Dig ing4 Vooruit iog Programmeer mal A054 Sel digit ing 41 A054<br />

09 Opto common Voor opto 9akoppelde uitgangen Elektronisch geisoleerd met<br />

opto ultgangen vanana loge 1 0 en digitale ingangen<br />

11 24VDC Doorverbonden naar di9itaal common<br />

Ooordrive geleverde voedin9 voordigilale ingangen<br />

Maximale uitgangsstroom is 100 mA<br />

12 10 VOC Ooorverbonden naar analoog common P038<br />

13 t10 V ing 2<br />

Door drive geleverde voeding voor 0 10 V externe<br />

potentiometer<br />

Maximale uitgangsstroom is 15 mA<br />

A095<br />

Nietaelief Voor externe 0 10 V unipolair of tl0 V bipolair P038<br />

Ingangsvoeding ingangsimpedantie 100 kOhm of A051 A054<br />

potentiomete oper<br />

A123 A132<br />

14 Analoog common Voor0 10 V in9 of 4 20 mA ing Elektronisch geisoleerd met<br />

aneloge ingangen en uitgangen van digitale I O en opto<br />

uitgangan<br />

15 4 20 mA in9 2<br />

Niel aelief Voor externe 4 20mA ingangsvoeding P038<br />

ingangsimpedantie 250 Ohm A051 A054<br />

A132<br />

16 Anal uilgang Uitfreq 0 10 Oe default analogeuitgang is0 1 0 V Als u een stroomwaarde A065 A066<br />

will converteren verandert u deOIP schakelaar Sel anal<br />

uitgang In 0 20 mA Programrneer met A065 Sel anal uitgl<br />

Oe maximale analoge waarde kan worden geschaald met<br />

A066 Anal uitg h0091<br />

Maximale belasting 4 20 mA 525 Ohm 10 5V<br />

0 10 V f kOhm 10 mAl<br />

17 Opto uitg 1 Mlr in badrt Programmeer met A058 Sel oplo uitg 1 J A058 A059<br />

18 Opto uitg 2 Opfreq Pr09rammeer met A061 iSel opto uilg 21 A061 A062<br />

19 RS485 OSI Aansluitterminal moet op veili9heidsaarding PEworden<br />

afscherming aangesloten wanneer de RS485 OSI communicatiepoort<br />

1 Zie voetnoot 1 en 4 op biz 7<br />

wordt gebruikt<br />

2 0 10 V ing en 420 mA ing ziin verschiliende ingangskanalen en kunnen tegelijkertijd worden aangesloten<br />

Ingangen kunnen onafhankelijk voorsnelheidsregeling worden gebruikt of gezamenlijk wanneer in de PID rnode<br />

wordt gewerld<br />

A064<br />

A064


o<br />

Opstarten van drive voorbereiden<br />

Nederlands g<br />

OPGELET De voeding naar de drive moet ingeschakeld zijn om de<br />

onderstaande<br />

opstartprocedures te kunnen uitvoeren Soms staat de huidige<br />

spanning op de binnenkomende lijnpotentiaal Om gevaar voorelektrische<br />

schokken of schade aan de apparatuur te voorkomen<br />

mag uitsluitend bevoegd<br />

onderhoudspersoneel de onderstaande procedure uitvoeren Voordat u begint<br />

dient u de procedure zorgvuldig te lezenen te begrijpen AIs eengebeurtenis niet<br />

plaatsvindt terwijl u deze procedure uitvoert ga dan niet verder Schakel aile<br />

voeding uit inClusief door de gebruiker verschafte stuurspanningen Doorde<br />

gebruiker verschafte spanning kan aanwezig zijn zelfs als de sterkstroom naar<br />

de drive niet is ingeschakeld Verhelp de storing voordat u verdergaat<br />

Voordat u de voeding naar de drive inschakelt<br />

1 Controleer of aile ingangen op de correcte terminals zijn aangesloten en goed<br />

vastzitten<br />

o 2 Controleer of de sterkstroom van de AC lijn bij de schakelaar zich binnen de<br />

o<br />

o<br />

nominale waarde van de drivebevindt<br />

3 Controleer of aile digitale stuurstroom 24 V is<br />

4 Controleer of de DIP instellingsschakelaar Sink SNK Source SRC zo is<br />

ingesteld dat hij overeenkomt met uw stuurstroombedradingsschema<br />

Zie biz 7 voorde plaats<br />

Belangrijk ijetdefault stuurschema is Source SRC De aansluittenrunal<br />

Stoppen wordt doorverbonden IO aansluitterminals 01 en 1 I<br />

om starten vanaf het toetsenbord mogelijk te maken AIs het<br />

stuurschema in Sink SNK wordt veranderd moetde<br />

doorverbinding vanIO aansluitterminals 01 en IIworden<br />

verwijderd en tussenIOaansluitterminals 01 en 04 worden<br />

geinstalleerd<br />

o 5 Controleer of de ingang toppen aanwezig is anders startde drive niet<br />

Belangrijk AIs IOaansluitterminal 01 als een stopingang wordt gebruikt moet<br />

de doorverbinding tussenIO aansluitterminal 01 en 1 1 worden<br />

verwijderd<br />

Schakel de voeding naar de drive in<br />

o 6 Schakel de sterk en stuurspanning naar de drive in<br />

o 7 Zorg datuvertrouwd bent met de integrale toetsenbordfuncties zie volgende<br />

bladzijde voordat u enige parameters Groep programmeren gaat instellen<br />

Besturing van Starten Stoppen Richting en Snelheid<br />

De default parameterwaarden die in de fabriek zijn ingesteld zorgen datde drive<br />

vanaf het integrale toetsenbord kan worden bestuurd Er is geen programmering<br />

nodig om de drive rechtstteeks vanaf het integrale toetsenbord te starten stoppen<br />

van richting te veranderen en de snelheid ervan te regelen<br />

Belangrijk Zievoor het uitschakelenvan achterwaartse bediening A095<br />

Achteruit uit<br />

Raadpleeg biz 17 voor een uitleg van de foutcode als zich bij het opstarten een<br />

fout voordoet Raadpleeg de Gehruikersha71dleidi71g van de PowerFlex 40 op de<br />

bij de drive geleverde cd voor volledige informatie over het oplossen vari<br />

problemen


Nederlands 10<br />

Integraal toetsenbord<br />

00 00<br />

00<br />

@Wg<br />

10<br />

CD QJ<br />

If 10<br />

Menu Beschrljvlng<br />

d<br />

P<br />

q<br />

Nr LED Status LED Beschrijving<br />

F<br />

Dlsplaygroep alleen bekllken<br />

Bestaat uit vaak bekeken bednjfscondilies van de dnve<br />

Besl progremmeergroep<br />

Bestaa u de meest gebruikle programmeerbare<br />

functies<br />

UI gebreldeprogremmeergroep<br />

Bastast u l de resterende programmeerbare functies<br />

Fou eanduldlng<br />

Besteat uit een lijs van codes voor spedfieke<br />

foulcondilies Wordl slleen weergegeven wanneereen<br />

lout aanwezig is<br />

0 Status Draaienl Rood brandt Geeft aan dat de drive in bedrijf is en opdracht voor motordraairichting<br />

Richting continu IS gegeven<br />

Rood knippert<br />

draairichtina<br />

Drive heeft opdracht gekregen om<br />

te veranderen Geeft<br />

werkelijke motordraairichting aan terwijl drive ecelereert tot nul<br />

@ Alfanumeriek Rood brandt Geeft parameternummer parameterwaarde of foutcode aan<br />

display<br />

continu<br />

Rood knippert<br />

Als een digit knippert betekent dit dat het digit kan worden bewerkt<br />

Als aile digits knipperen geeft dat een foutconditie aan<br />

8 Weergegeven Rood brandt Geeft de eenheden van een weergegeven parameterwaarde aan<br />

eenheden continu<br />

0 programmeerstatus Rood brandt Geeft aan dat de parameterwaarde kan worden veranderd<br />

continu<br />

0 Foutstatus Rood knippert Geeft aan dat de drive ineen foulconditie verkeert<br />

0 Potentiometerstatus Groen brandt Geeft aan dat de potentiometer op het inlegrale toetsenbord actief is<br />

continu<br />

8 Status startloets Groen brandl Geeft aan dat de starttoets continu<br />

op het integrale toetsenbord actief is<br />

De toets Achteruit is ook actief tenzij uitgeschakeld door A095<br />

Achteruit uit<br />

Nr Toets Naam Beschrijving<br />

i<br />

0<br />

Escape<br />

Een stap terug in programmeermenu<br />

Een wijziging van een parameterwaarde annuleren en de mode<br />

Programmeren afsluiten<br />

@ Selecteren Een stap vooruit in programmeermenu<br />

Een digit selecteren tiidens het bekijken van de parameterwaarde<br />

f@J<br />

Pijl Omhoog Door<br />

Piii Omlaag<br />

groepen en parameters scrollen<br />

De waarde van een knipperend digit verhogenlverlagen<br />

@ Enter Een stap vooruit in programmeermenu<br />

Een wijziging van een parameterwaarde opslaan<br />

Potentiometer WOldt gebruikt om de drivesnelheid te regelen Default is actief<br />

Wordt geregeld door parameter P038<br />

CD Starten Wordt gebruikt om de drive te starten Default is actiet<br />

Wordt geregeld door parameter P036<br />

6l<br />

CQ<br />

Achteruit Wordt gebruikt om de draairichting van de drive om te keren<br />

Default is actief<br />

Wordt geregeld door parameter P036 en A095<br />

Stoppen<br />

Wordt gebruikt om de drive te stoppen of een fout te wissen<br />

Deze toets is altijd actief<br />

Wordt geregeld door parameter P037


Parameters bekijken en bewerken<br />

Nederlands 11<br />

Delaatste door de gebruiker geselecteerde displaygroepparameter wordt opgeslagen wanneer de<br />

voeding wordt uitgeschakeld en wordt weergegeven als default wanneer de voeding weer wordt<br />

ingeschakeld<br />

Hieronder staat een voorbeeld van een algemeen integraal toetsenbord en displayfuncties Oit<br />

voorbeeld verschaft algemene instructies voornavigatie en illustreert hoe u de eerste parameter<br />

Programmeergroep moet programmeren<br />

Stap Toets enl Voorbeelden<br />

1 Wanneer de voeding wordt ingeschakeld wordt<br />

het laatste door de gebruiker geselecteerde<br />

n<br />

parameternummer van de displaygroep kort met u U iiz<br />

I<br />

knipperende tekens weergegeven Het display PROGRAM<br />

VOLTS<br />

nlo<br />

FAULT<br />

gebruikt vervolgens de huidige waarde van die<br />

parameter<br />

0 0<br />

als default Het voorbeeld toont de waarde<br />

dOOI Uitgangsfreq terwiil de drive stilstaat<br />

2 Druk eenmaal op Esc om het parameternummer van<br />

de displaygroep weer te geven dat bij opstarten<br />

getoond wordt Het parameternummer knippert<br />

3 Oruk nogmaals op Esc om naar het groepmenu te<br />

gaan De letter van het groepmenu knippert<br />

4 Oruk op de piil Omhoog of Omlaag om door het<br />

WOfG<br />

Id 00 tlH ti<br />

PROGRAM FAULT<br />

0 0<br />

IfdOO<br />

groepmenu d P en A te scrollen PROGRAM FAULT<br />

o 0<br />

5 Druk op Enter of Sel om naar een groep te gaan Het<br />

rechter digit van de laatst bekeken parameter in die<br />

groep knippert<br />

I<br />

10<br />

VOLTS<br />

0 AMPS<br />

o HERTZ<br />

80f@ P 0 3 ti<br />

6 Druk op de pijl Omhoog of Omlaag om door de<br />

PROGRAM FAULT<br />

parameters te scrollen die zich in de groep bevinden 0 0<br />

WOfG<br />

7 Oruk op Enter of Sel om de waarde van een parameter<br />

te bekijken Als u de waarde niet wilt bewerken drukt u<br />

op Ese om naar het parameternummer terug te keren U<br />

8 Oruk op Enter of Sel om naar de programmeermode te<br />

gaan en de parameterwaarde te bewerken Het rechter<br />

digit knippert en het LED Programmeren brandt als de<br />

parameter bewelkt kan worden<br />

9 Druk op de piil Omhoog of Omlaag om de parameter<br />

waarde te veranderen Druk desgewenst op Sel om<br />

van digit naar digit of van bit naar bit te gaan Het digit<br />

of de bit dat of die ukunt veranderen knippert<br />

80f@ I 2 nlOVOLTS<br />

PROGRAM FAULT<br />

0 0<br />

BOf@ I 2 3 I ti<br />

100f@J<br />

PROGRAM FAULT<br />

0<br />

10 Druk op Esc om een wiiziging te annuleren Het digit<br />

stopt met knipperen de vorige waarde wordt hersteld<br />

en het LED Programmeren gaat uit<br />

Of U z<br />

I 2 2 nlOVOLTS<br />

Druk op Enter om een wijziging op te slaan Het digit<br />

stopt met knipperen B<br />

PROGRAM FAULT<br />

en het LED programmeren gaat<br />

uit<br />

0 0<br />

11 Druk op Esc om naar de parameterliist terug te keren<br />

Bliif op Esc drukken om het programmeermenu te<br />

verlaten<br />

P 0 3 H<br />

Als het display niet verandert door op Ese te drukken PROGRAM FAULT<br />

dan wordt dOOl Uitgangsfreq weergegeven Druk op 0 0<br />

Enter of Sel om naar het groepmenu te gaan


Nederlands 12<br />

Oisplaygroepparameters<br />

Nr Parameter MInIMax Displey Optles<br />

dOOI Ungangsfreq O O Max fraquenlie 0 1 Hz<br />

d002 10pdrachtlreq O O IMexfrequentie 0 1 Hz<br />

d003 Uitgangsslroomj O OO A van drive x 2 0 01 A<br />

d004 Uitgangsspanningj O Nominale V van drive 1 VAC<br />

d005 DC busspannlng Gebaseerd op drivetype 1 VDC<br />

Zie de PowerFlex 40 gebruikershandleiding op cd voor maer informatieover perameters<br />

d006 Drivestatus 011 1 Conditiegoed Ilil 3 Llil 2 Il1l1 IlitQ<br />

Deceleraren Acceleraren Vooruit In bedrijt<br />

d007 Code fout x F2IF122 Fl<br />

d009<br />

dOlO Procesdisplay 0 00 9999 0Q1 1<br />

d012 Besturingsbron 09 Bil1 Snelheidsreferentie BilWmrlQ<br />

lie P036 9 Jog freq lie P036 9 Joggen<br />

d013 Statbesturing 0 1 II Ingang aanwezig IliLa Llil 2 Il1l1 IlitQ<br />

DB trans aan lng Stoppen Rich AUIT In StrWUlTin<br />

dOl4 Stal dig Ing 01 1 Ingang aanwezig IliLa Llil 2 Il1l1 IlitQ<br />

Digit ing 4 Digit ing 3 Digit ing 2 Digit In I<br />

d015 iCommslatus 01 I Conditie goed IliLa Ilit 2 Il1l1 IlitQ<br />

Comm fout Optie DSI Overdrecl1t Ontvangst<br />

d016 IBesturingsSWvers 1 00 99 99 0 01<br />

dOH Orivetypel 100119999 1<br />

d018 Totaletijd 0 9999 uur 1 10 uur<br />

d019 Data testpuntj O FFFF 1 Hex<br />

d020 Anal ing 0 10 VI 0 0 100 0 0 1<br />

d021 Anallng 4 20 mAl 0 0 100 0 0 1<br />

d022 Uitgangsvarmogen O OO IDrive varmogen x 2 0 011 N<br />

d023 Uitg pwr factor 0 0180 0 gr 0 1 gr<br />

d024 Drivetemp 0 120 gr C 1 gr C<br />

d025 Tellerstatus 09999 I<br />

d026 Timerstatusj 0 0 9999 0 1 see<br />

d028 Status sip log 017 1<br />

d029 Koppelstroom O OO A van drive x 2 0 01 A<br />

QJ<br />

Smart opstarten met van algemene parameters de<br />

programmeergroep<br />

De PowerFlex 40 is zodanig ontworpen dat opstarten eenvoudig en efficient is De programmeergroep<br />

bevat de meest gebruikte parameters<br />

Stop de drive alvorens deze parameter Ie wijzigen<br />

Nr Parameter I MInIMax Display Optles Default<br />

P031 Motorspanning 120 Nominale V van drive 1 VAC Gebaseerd op drivatype<br />

QJ Instellen op de nomlnale molorspanning<br />

P032 Motorireq I I 5 400 Hz 1 Hz 60 Hz<br />

QJ Instellen op de nomlnale motorfrequentie<br />

P033 Mtr over1Jel strm I O O INomlnale A van drive x 2 0 1 A Gebaseerd op drlvatype<br />

Instellen op de maximaalloegeslane motorstroom<br />

P034 Min frequentie 10 0 4000 Hz 0 1 Hz 0 0 Hz<br />

SIel1 de laagsla continue ultgangsfrequentie van de drive In<br />

P035 Max frequentie 10 400 Hz 1 Hz 60 Hz<br />

QJ Stelt de hoogsta uilgangsfrequentie van de drive in<br />

P036 Bron Starten 10 6 0 Toelsenbollfll 1<br />

QJ Stell het stuursehema in dat wordt gebruikt om de drive te<br />

1<br />

2<br />

3draadsn<br />

2c1raads<br />

0<br />

starlen<br />

3 u2 dr niv sns<br />

Indien aetief dan is ook de toets Achteruit actief tenziJ<br />

4<br />

5<br />

2 drsnlhhg<br />

Comm poorr<br />

uitgeschakeld door A095 Achteruit uit 8 Kortv a ult


Zie de PowerFlex 40gebruikershandleiding op cd voor meer informatie over parameters Nederlands 13<br />

Q Stop de dnve alvorens deze parameter Ie wijzigen<br />

Nr Parameter I MinIMax Display Optles Default<br />

P037 Stopmode 1019 0 Acldee<br />

lll<br />

1 1twf Vrijlp Itws<br />

11<br />

Actieve stopmode voor aile stopbronnen b v toetsenbord<br />

2 DC rem Itws<br />

ll<br />

voorult draaien IO aansluitterminal 02 achteruil draaien<br />

3 DCRmAut Itws ll<br />

I O aansluitterminal 03 RS485 poort behalve zoals<br />

hieronder<br />

4 Acedee<br />

5<br />

Betangrljkaangegeven Vnjloop<br />

1 aansluitterminalOl is altijd een ingang In<br />

6 DC rem<br />

vrljloop tot stilstand behalve wanneerP036 Bron Starten<br />

7 DC rem<br />

op 3 draads<br />

autom<br />

bestunng isIngesteld In 3draads besturing 8 A1de EM RFW wordt I O aansluitterminal 01 besluurd door P037<br />

9 A1de EM rem<br />

SloPmodel<br />

1<br />

Ingang Sloppen wlst ook de actleve lout<br />

P038 Snelheidsre<br />

10 7 o Drive pot 0<br />

Slell de bron voor de snelheidsreferentie voor de drive in<br />

1 Interne Ireq<br />

BelangrlJk<br />

2 0 10 V ingang<br />

Wanneer A051 of A052 Sel digit ing x op<br />

optie ang<br />

2 4 5 6 13 of 14 word ingesteld en dedigilale<br />

Ingang actief is gaal A051 A052 A053 of A054 de<br />

snelheidsreferentie van dezeparameter overschrijven<br />

5<br />

6<br />

Comm poorl<br />

Stp loglsch<br />

Raadpleeg voor details hooldstuk 1 van de<br />

Gebruikershandleiding van de PowerFlex 40op cd<br />

7 Anal Inmull<br />

P039 Accel tijd f 10 0 600 0 see 0 1 see 10 0 see<br />

Slell de versneillng in voor aile snelheidsloenames<br />

P040 Deeel tljd 1 10 1 600 0 see 0 1 see 10 0 see<br />

Stell de vert raging Invoor aile snelheidsafnames<br />

P041 Nr labnekslnsf 10 1 o Gereed ldle 0<br />

Q Reset aile paramelerwaarden op labnekslnslellingen<br />

1 Fabrieksinst<br />

P042 ISpanningsklassej 1213 2 Laagspanning 480<br />

Q Stelt de spanningsklasse in van 600V drives 3 Hoogspannlng 600 I<br />

Uitgebreide groepparameters<br />

Nr Parameter MinIMax DisplayOpties Default<br />

A051 ISel digit Ing 11 0 26 o Niet gebruikl 13 Reg 10 V In 4<br />

va Bansluitterminal 05 1 Ace dec 2 14 Reg20 mA in<br />

A052 Sel digit ing 2 VO aansluittermina 06<br />

2<br />

3<br />

Joggen<br />

Fout aux<br />

15<br />

16<br />

PID ull 4<br />

MOP werkt<br />

A053 Seldigit Ing 3 4 Preset Ireq 17 MOP ull 5<br />

va aans uitterminal07 5 Lokaal 18 Tmr slarlen<br />

A054 ISel dlgll ing 41<br />

Q<br />

6 Comm poort 19 Teiler in 11<br />

I O aanslulfferminal 08 7<br />

8<br />

Foul wissen<br />

AcldeStpFtws<br />

20<br />

21<br />

Resel time<br />

Reset teile<br />

9 VrlpStp ftws 22 Rset tim tlr<br />

10 DClnjStpFtws 23 Log Ing I<br />

11 Voorult jog 24 Log ing 2<br />

12 Aehtrultjog 25 Str grens 2<br />

26 Anal jnvert<br />

A055 Sel relais ultg 0 22 o Gereedlfout 11 Loglngl 0<br />

1 Op Ireq 12 Log Ing 2<br />

2 Mtr in bedrl 13 Log 1 en 2<br />

3 Aehteruit 14 Log 1 012<br />

4 Motoroverbel 15 Stp log uit<br />

5 Reg acedee 16 Timer uil<br />

6 Te hoge Ireq 17 Teiler uit<br />

7 Te hg stream 18 Te gr PFhoek<br />

I<br />

8 Te hoge DC V 19 Vrls anal In<br />

o<br />

F<br />

20<br />

21<br />

Param reg<br />

Nt hrst fout<br />

22 EM rem<br />

A056 INlv relais ultg 0 0 9999 0 1 0 0<br />

A058 Sel opto ultg 1 0 22 o Gereedlfout 11 Log Ing 1 A061 Selopto ultg 2J 1 Opfreq 12 2 Lag Ing<br />

2<br />

1<br />

2 MtrIn bedrl 13 Logl en 2<br />

3 Actrterult 14 Logl012<br />

4 Motoroverbel 15 Stp log ult<br />

5 Reg acedee 16 Timer uit<br />

6 Te hoge Ireq 17 Teiler uit<br />

7 Tehg stroom 18 Tegr PFhoek<br />

8 Te hoge DC V 19 Vrls analin<br />

9 Pagingen op 20 Param reg<br />

10 Te hg enal V 21 Nf hmffout<br />

22 EM rem<br />

3<br />

0


Nederlands 14<br />

Zie de PoWerFlex 40 gebruikemhandleiding op cd voormeerinlormalie over paramelers<br />

I Nr Parameter IMlnlMax D1splay Optles Default<br />

A059<br />

INiv opto uilg 1 I<br />

10 019999<br />

10 1<br />

A062 Nivopto uitg<br />

0 0<br />

2<br />

Inslelling A055 A05Ben AOBl MinIM A05B A059 en A062<br />

6<br />

01400 Hz<br />

7 01160<br />

B 0815 V<br />

10 01100<br />

16 0 19999 see<br />

17 Telling 19999<br />

Ie 1I160gr<br />

20 011<br />

A064 Log opto uitg 10 3 11 0<br />

OptieA064 Logoplouitg 1 L090plouil92<br />

0 NO normaal open NO normael open<br />

I NC normaal gesloten NO normael open<br />

2 NO normeal open NC normaBlgeslolen<br />

3 NC normaal geslolen NC normael gestaten<br />

A065 ISel analuilg 10120 l<br />

Min male Maximale uilgangswaarde Posltie<br />

Optie Uilgangsberelk ultgangswaarde Anal uitg hoog OIP schakelaar<br />

o Uirtreq 0 10 0 10V OV OHz P035 IMex lrequentie 010V<br />

l Uitgstro IO 0 10V OV OA 200 nomfnale strcom vandrive 0 10V<br />

2 Uit VO l0 O IOV OV OV 120 nominale u gangsspannlng van drive O IOV<br />

3 Uil vrm 0 10 0 10V OV OkW 200 nominael vermogen vandrive o IOV<br />

4 Testgeg 0 10 o IOV OV OOOO 65535 Hex ffFF O IOV<br />

5 Uirtreq 0 20 020 mA OmA OHz P035 1M lrequentie 0 20mA<br />

6 Uilgstr 0 20 020mA OmA OA 200 nomlnale stroom van drive 02OmA 7Uil V 0 20 0 20mA OmA OV 120 nominale ultgangsspanning vandrive 0 20mA<br />

8 Uil vrm 20 020mA OmA OkW 200 nominaal vermogen vandrive 020mA 9 Testgeg 0 20 020mA o mA 0000 65535 Hex fFfF 0 20mA<br />

10 Ultlreq 4 20 4 20mA 4mA OHz P035 IMax frequenliej 0 20mA<br />

II Uitgsfr4 20 4 20mA 4mAcOA 200 nominate stroom van drive 0 20mA<br />

12 Uit V 4 20 4 20mA 4mA OV 120 nominate uitgangsspanning van drive 0 20mA<br />

13 Uil vrm 4 20 4 20mA 4mA OkW 200 nominael vermogen van drive 0 20mA<br />

14 Tesfgeg 4 20 4 20 mA 4 mA 0000 65535 Hex fFFF 02OmA<br />

15 Uilkopp 010 0 10V OV OA 200 nominale slroom van drive 0 10V<br />

16 020 0 20mA Uitkopp OmA OA 200 nomina e stroom van drive 0 20 mA<br />

17 4 Uilkopp 20 4 20mA 4mA OA 200 nominale slroom van drive 020mA<br />

lB Setpunt 010 O IOV OV O 100 0 Setpunt instelling 0 10V<br />

19 5etpunt0 20 0 20mA OmA OO 100 00 Setpunt inslelling 0 20mA<br />

20 5elpunI4 2Q 420mA 4mA 0 100 0 Setpunl inslelllng 0 20mA<br />

A066 lAnai uitg hoag 0 800 1 100<br />

A067 IAecel tijd 21 0 0 600 0 see 0 1 sec 20 0 see<br />

A068 Decel lijd 2 0 1 600 0 see 0 1 see 20 0 see<br />

A069 Inteme Ireq 0 0 400 0 Hz 0 1 Hz 60 0 Hz<br />

Or<br />

A070 Presetfreq<br />

0 01400 0 Hz 0 1 Hz 0 Hz<br />

A071 Presel 1 freq 5 OHz<br />

A072 Presetfreq 2<br />

100 Hz<br />

A073 Preset lreq 3 20 0 Hz<br />

A074 Preset Ireq 4 30 0 Hz<br />

A075 Preset Ireq 5 40 0 Hz<br />

A076 Preset Ireq 6<br />

SO OHz<br />

A077 Preset freq 7 60 0 Hz<br />

1 Om Preset Ireq 0 te aetiveren stelt u P038 Snelheidsre in op optie 4<br />

lngangstoesland<br />

vandigltale ing<br />

lngangstoesland lngangsloestand Gebruiktepammeter<br />

1 vandigitale log 2 van 3 digltale Ing Frequenliebron AcceVdecel 2<br />

1 Oaanslultterminal05 110aanslulttermlnal 06 1 0 l<br />

aansluittermlnal 07<br />

0 0 0 Presel1reqO IAcceltijd Decel tijd 1 1<br />

1J<br />

0 0 Presetfreq Accel tijd 1 1 Decel tijd 11<br />

2<br />

i S i re<br />

I I 0 0 IPresetfreq2 IAccel tijd 2 IDecel tijd 2<br />

1 I 0 Presetfreq3 IAcceltiJd 2J I IDecel tiJd 2<br />

I<br />

0 0 1 IPreselfreq4 Accel tijd IJ Decel tijd 1J<br />

I 0 1 Presellreq51 Accel tijd 1 Decel tijd 1<br />

I 0 1 Presellreq6 Accel tiJd 2J I Decelijd 2<br />

I 1 1 preset freq 7 IAccel tijd 2J IDeceI tIJd 2J<br />

a<br />

V<br />

AcceI2 en Oece12 wordt ingesteld en de lngang actiells gaat de iogang san de<br />

A078 Jaglreq 10 O Max Irequentie 10 1 Hz 10 OHz<br />

0


Zie de PowerAex 40 gebruikershandleiding op cd voor meer informatie over parameters Nederlands 15<br />

Nr Parameter IMinlMax Display Optles Default<br />

A079 Jag AcceVDeeel 10 1 600 0 see 0 1 see 10 0 see<br />

A080 DC remlijdj 10 0 99 9 see 0 1 see 0 0 see<br />

Een nslelling van 99 9 see COnlinu<br />

A081 DC remniveaul O O A van drive x 1 8 0 1 A A x 0 05<br />

A062 Sel DB weerstand 0 99 O Uit 2 Gn bescherm 0<br />

Q 1 Norm RA wrst 3 99 van cyclus<br />

A083 1 S kremme 01100 1 0 Uit<br />

A084 Selboost 0 14 Instelfingen in van basisspanning 8<br />

Aileen actiel wanneerA125lKoppelprestaties op 0 VlHzop maal<br />

7 4 11 kW<br />

o V HZ is Ingesteld Constant koppel<br />

1 30 0 VT 5 0 0 geen IR 10 10 0 cr<br />

2 35 0 VT 6 0 0 11 12 5 Cr<br />

3 400 VT 7 2 5 cr 12 15 0 cr<br />

4 45 0 vr 8 5 0 cr 13 17 5 cr<br />

9 7 5 Cr 14 20 0 cr<br />

A085 Start boost 10 0 25 0 0 1 2 5<br />

Aileen actief wanneerA084ISel boost en A125 Koppelprestatlesj op 0 zijn ingesteld<br />

A086 Knikspanning 10 0 100 0<br />

10<br />

Aileen actiel wanneerA084 Sel boost en A125 Koppelpreslalies op0 zijn ingesteld<br />

10<br />

Aileen actiel wanneer A084ISel boost en A125 Koppelprestalies op 0 zijn ingesteld<br />

A087 IKnikfrequentle 10 0 400 0 Hz<br />

1 25 0<br />

1 Hz 15OHz<br />

A088 IMax spanningj 201N0minale V 1 VAC Nominale V<br />

A089 Stroomgrens 11 O 1 A van drive x 1 81 0 1 A AX I 5<br />

A090 Selmlr overbel 02 o Geen derale 1 Min derate 0<br />

2 Max derale<br />

A091 PWM Irequentiel 2 0116 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Pagingaul hstrt 0 9 1 0<br />

A093 Vertr aut hslrt 0 0 3000 see 0 1 see 1 Osec<br />

A094 Start bij powerupj 0 1 O Uit 1 Aan 0<br />

Q<br />

A095 Aehleruit uit 0 1 0 A uit vrijg 1 Auit uit 0<br />

QJ<br />

A096 Vlg sfrtvrijgeg 0 1 o Uti 1 Aan 0<br />

A097 Compensatlel 013 O Uil 2 MectranisCh 1<br />

1 Eiekfrisch 3 Beide<br />

A098 Uilsch sfroom SW O O A van drive x 2 0 1 A 0 0 Uti<br />

A099 Procesfaetor 0 1999 9 0 1 30 0<br />

Al00 Fout wissenl 0 2 o Gereed ldle 1 Fout reser 0<br />

QJ 2 Buffer wis<br />

Al01 Program vergrend 0 9999 o Ontgrendeid 1 Vergrendeld 0<br />

Al02 Sel testpunt 400IFFFF 1 Hex 400<br />

At03 Comm datasnelhj 0 5 0 1200 3 9600 3<br />

De drive moet uit en aan worden geiet voordat<br />

randeringen op<br />

1 2400 4 19200<br />

de werking van de drive van invloed<br />

zlJn<br />

2 4800 5 38400<br />

Al04 Comm nodeadres 11 247 1 100<br />

De drive meet un en sanworden Qezet voordat<br />

v randeringen opde Werking van de drive van invloed<br />

ZIJn<br />

Al05 Actie comm vensl 03 o Fout 2 Stoppen 0<br />

1 Vrijlp stop 3 Verder Itsfe<br />

l<br />

Al06 IComm verliesfijd 0 160 0 see 0 1 5 0<br />

Al07 IComm indelingl 02 0 RTU8 N 3 RTU 8 N 2 0<br />

De drive moet uit en aan worden gezel voordat<br />

1 RTU 8 E l 4 veranderingen op de werking van de drive van invloed<br />

zijn<br />

2 RTU 80 1 5<br />

RTU 8 E 2<br />

RTU 8 0 2<br />

Al08 Taall 10 1 Engels 6 Gereserveerd 1<br />

2 Frans 7 Portugees<br />

3 Spaans 8 Gereserveerd<br />

4 Italiaans 9 Gereserveerd<br />

5 Duils 10 Nederlands<br />

Al09 Setpnt anal utig 0 0 100 0 0 1<br />

C Anal in 0 1 OV Ig 0 01100 0 0 1 0 0<br />

0 0


Nederlands 16<br />

Nr Parameter MInIMax Dlsplay Optles<br />

Zie de PowerFlex 40 gebruikershandleiding op cd voormoor inlormalie over pammelers<br />

AliI Anal in 0 10V hg 0 0 100 0 0 1 100 0<br />

Q<br />

Default<br />

A112 lAnai in4 20mA Igl 0 01100 0 0 1 0 0<br />

QJ<br />

A113 Anal in4 20mA hgl 0 0 100 0 0 1 100 0<br />

Q<br />

A114 Slipfreq@l 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

A115 Procestijd korl 0 00199 99 01 0 00<br />

A116 Procestijd lang 0 00199 99 0 01 0 00<br />

A1l7 Busreg mode 0 1 O Uil 1 Aan 1<br />

A118 Slroomgrens 21 O I A van drive x 1 8 0 1 A Ax 1 5<br />

A119 Sprongtrequenlie 0 400 Hz 1 Hz OHz<br />

A120 ISprongtreq band 0 0 30 0 Hz 0 1 Hz 0Hz<br />

A121 Tijd lout stop Oi5 o 60 see 3 360 see 0<br />

1 120see 4 480 see<br />

2 240see 5 Fout ull<br />

A122 Verlies anal ing 0 6 O Uil 4 Rei min Ireq 0<br />

1 Foul F29 5 Rei ma freq<br />

2 Sloppen 6 Ref inl Iraq<br />

3 Rei nul<br />

A123 110 V bipolvrijg 0 1 o Unipolair In 1 Blpolair in 0<br />

A124 Var PWM ult 0 1 O Aan 1 Uil 0<br />

A125 Koppelpreslatles 011 0 VlHz 1 Sensrlz vect 1<br />

A126 Motorstroom O I A van drive x 2 0 1 A Nomlnale A<br />

A127 Aulolune 02 0 Gereed ldle 2 Dmai Iunen 0<br />

1 Stat Iunen<br />

A128 SpanningsvaIIR 0 01230 0 VAC 0 1 VAC NomineleV<br />

A129 Fluxstroomre O OO Motorspanning 0 01 A Nomlnale A<br />

A130 PID tom hoog 0 0 400 0 0 1 60 0<br />

A131 PID 10m laag 0 0 400 0 0 1 0 0<br />

A132 ISel PID re 0 8 0 PID ull 5 Setpn1 tnm 0<br />

1 PID setpunt 6 O 10V trim<br />

2 0 10 V Ingang 7 4 20mA 10m<br />

3 4 20 mA ingang 8 Comm 10m<br />

4 Comm poort<br />

AI33 ISel PID Ieedbeck 0 2 0 0 10 V ingang 2 Comm poort 0<br />

1 4 20 mA mgang<br />

A134 PID prop versl 0 00199 99 0 01 0 01<br />

A135 PID integ tijd 0 0 999 9 see 0 1 2 0<br />

AI36 PIDdiff snelh 0 00199 99 l see 0 01 0 00<br />

A137 PID selpuntl 0 0 100 0 0 1 0 0<br />

A138 PID dOde zone 0 0 10 0 0 1 00<br />

A139 PID oorbell 0 01400 0 Hz 0 1 Hz 0 Hz<br />

A140 Stp lagisch 0 71 i<br />

0001ibAFF 4digils ooFl<br />

A147<br />

rs a<br />

e3ri<br />

lij t s40 op<br />

AlSO Tljd 0 7 stp log 0 01999 9 see 0 1 see 30 0 see<br />

A157<br />

A160 Vrtr EM rem uitl 0 01 10 00 see 01 see 2 00 see<br />

A161 Vrtr EM rem aan 0 01110 00 see 0 01 see 2 00 see<br />

A162 Sel MOP reset 0 1 o<br />

MOP reinul 1 Save MOP ref 1


Foutcodes<br />

Nederlands 17<br />

Als u een fout wilt wissen druktu op de Stop toets zet u de drive uit en aan of<br />

stelt u AlOO Fout wissen in op I of2<br />

Nr Fout<br />

Beschrijving<br />

F2 Aux ingang Conlroleer de bedrading op alstand<br />

F3 Verm verlies Bewaak de binnenkomende AC lijn op laa9spanning 01 Iijnvoedingsonderbreking<br />

F4 Ondrspanning J Bewaak de binnenkomende AC lijnop laagspanning of Iijnvoedingsonderbreking<br />

FS Overspanning Bewaak de AC lijn op<br />

hZ elijnspanning 01 transi ntcondities Bus overspanning kan ookworden veroorzaakl<br />

door motorregeneratie erleng de deeellijd of inslalleer de optie dynamische rem<br />

F6 Molor lJ<br />

gestopt Vertroog IAccelijd x of verminder debelasting zOdat de uitgangsstroom van de dove de door parameter A089<br />

Slroomgrensl ingesteldeslroom niel oversehnjdl<br />

F7 Motoroverbelast 1J Er issprake van te hoge motorbelasling Verminderde belasting zOOal de u gangssfroom van de drive de door<br />

parameter P033 Molorslroom ingeslelde stroom niet oversehrijdt<br />

F8 Overtmp koelvin J<br />

Conlroleer op<br />

7teblokkeerde of vulle koelvinnen Controleer 01 de omge ngstemperatuur 40 C voor<br />

IP 30INEMA 1 UL type 1 installalies ot 50 C voor inslallaties van helopen type niel heeft oversehreden<br />

Conlroleer de venlllalOr<br />

F12 Overstroom HW Controieerde pragrammeong Controleer op te hage belasting onjuiste DC boost inslelling Ie hoog ingestelde<br />

DC rernspannin9 of andere oorzaken voor te hogs stroom<br />

F13 Aardfout Conlroleer of de motor en externe bedrading naar de uitgangsterminals van de drive goed geaard zijn<br />

F29 Verlies anai ing Een analoge ingang is gecori ligureerd op fout bij signaalverlies Er is een signaalverlies opgetreden<br />

F33 Pagingaut hslrt Verhelp de oorzaaky n de fout en wis de fout manueel<br />

F38 Fase U nf aarde Controleer de bedrading lussen de drive en motor Controleer de motor op geaarde fase<br />

F39 FaseV or aarda Vervang de dOVe als de foul niel kan worden gewisl<br />

F40 Fase W nr aarde<br />

F41 Kortsluiling UV Controleer de uitgangsterminalbedrading van de motor en drive op kortsluiting<br />

F42 Kortsluiting UW Vervang de drive als de loutniet kan worden gewist<br />

F43 Kortsluiting VW<br />

F48 Param default De dove heetl opdraeht gekregen de delaultwaarden naar EEPROM Ie schrijven Wis de loutof zet de dove u en<br />

aan Programmeer de driveparameters naar behoeven<br />

F63 Oversfroom SWI J<br />

Controleerde belaslingseisen en instelling van A098 Uitsch stroortr SW<br />

F64 Drv overbelast Verminder de belasUng 01 verleng de accel fijd<br />

F70 Voeding Zet het apparaal uit en aan Vervang de drive als de fout niet kan worden gewist<br />

F71 Verls netw Er is een fout opgetreden in hel comm ilicatienetwerk<br />

F80 SVC autotune De functieAutotunen is door de gebruikeT geannuleerd of mislukt<br />

FBI Comm verlies Als de adapler niet opzetlelijk is losgekoppeld eontroleer dan de bedrading naar de poort Vervan9 zo nodig de<br />

bedrading poort expander adapters of de complete dOVe Conlroleer de aansluiling Een edapter IS opzettelijk<br />

losgekoppeld Sehakel hem uit met A105 AcIie eomm verls<br />

Fl00 Parameter checksum Herslei fabneksinstellingen<br />

F122 Defect VO bord Zet het apparaat uit en aan Vervang de drive als de fout niet kan worden gewJst<br />

I<br />

Type lout Aulo reseVrun Confi9ureer met parameters A092 en A093


Nederlands 18<br />

van Afmetingen drive<br />

Frames van PowerFlex 40 Nominllle waarden zijn in kW<br />

Frame 120 VAC 1 fase 240 VAC 1 fase 240 VAC 3 fase 480 VAC<br />

3 fase 600 VAC 3fase<br />

B 04 04 0 4 2 2 0 4 2 2 0 75 4 0<br />

0 75 0 75 075 37 0 75 4 0 1 5<br />

1 1 1 5 1 5 1 5 2 2<br />

C 2 2 5 5 5 5 11 0 5 5 11 0<br />

7 5 7 5 7 5<br />

l m<br />

o m<br />

PowerFlex 40 AC drive<br />

8<br />

Afmetingen zijn in miliimeler<br />

Gewichten zijn in kilogram<br />

E<br />

A B C 0 E F Verzendgewlcht<br />

B 100 180 136 87 168 87 4 2 2<br />

C 130 260 180 116 246 4 3<br />

Optiesets Communicatie RFI filter IP 30INEMA 1UL type 1<br />

o<br />

J<br />

Iii<br />

g<br />

Iii Drive met Drive met<br />

Optle frame B frameC<br />

A Deksel comm 25 25<br />

B EMClijnlilter 50 60<br />

C EMClijnliller 229 309<br />

0 IP30 NEMA 1UL type 1 33 60<br />

IP30 NEMA 1UL type 1 64 60<br />

voor Deksel comm<br />

Frame B 22 JBAB<br />

00<br />

o<br />

00<br />

Frame B 22 JBCB<br />

gebruikt bij Deksel eomm<br />

Frame C<br />

22 JBAC<br />

Frame C 22 JBCC<br />

gebruikt bij Deksel comm<br />

U S Allen Bradley Drlves Technical suppon<br />

Tel 1 262 512 8176 Fax 1 262 512 2222 Emall support@drlves raJockwell com Onlinewww ab convsupportlabdnves<br />

Rockwell<br />

Pubiicatie 228 QS001 8 NL P januari 2004 Automation<br />

KomI in de plaals vanoktober 2002 Copyright@2004 RockWell Automalion Inc Aile reehten voorbehouden Gedrukt in Taiwan<br />

28 5<br />

152 2<br />

22 2


tm<br />

Inversor CA de frequencia<br />

ajustavel PowerFlex 40<br />

FRN 2 xx<br />

Partida rapida<br />

Este guia de Partida Rapida resume as etapas basicasnecessarias para instalar<br />

inicializar e programar 0 inversor CAde freqiiencia ajustavel PowerFlex 40 As<br />

informa oes fornecidasNi 2 substituem 0 Manual do Usuario e se destinam<br />

somente ao pessoal qualificado de manuten iio do inversor<br />

Para informayoes detalhadas sobre 0 PowerFlex 40 inc1uindo instruyoes de EMC<br />

considerayoes de utilizayao e precauyoes afins consulte 0 Manual do Usuario do<br />

PowerFlex 40 Publicayao 22B<br />

wwwab com manuals dr<br />

Precaugoes gerais<br />

no CD que<br />

UMOOl acompanha 0 inversorou em<br />

ATEN AO 0inversor contem capacitores de alta tensao que demoram para<br />

descarregar ap6s a remoyao da fonte de alimentayao principal Nao se esqueya<br />

de isolar a fonte de alimentayao principal das entradas de linha R S T Ll L2<br />

L3 antes de trabalhar no inversor Aguarde tres minutos para que os capacitores<br />

descarreguem para nfveis de tensao seguros Se isto nao forobservado podera<br />

ocorrerlesao pessoal ou morte<br />

LEDs de display escurecidos nao saD indicayao de que os capacitores<br />

descarregaram para nfveis de tensao seguros<br />

ATEN AO Poderao ocorrer danos no equipamento e ou lesao pessoal<br />

se 0<br />

parametro A092 Tent ReinAut ou A094 Partidaenerg for utilizado em uma<br />

aplicayao indevida Nao use essa funyao sem levar em considerayao os c6digos<br />

padroes e reguIamentos locais nacionais e intemacionais ou as diretrizes da<br />

industria<br />

ATEN AO Apenas 0 pessoal qualificado com inversores CA de freqiiencia<br />

ajustavel e mecanismos associ ados deve planejar ou implementar a instaIayao a<br />

energizayao e a manutenyao subseqiiente do sistema Se isso nao forobservado<br />

podera ocorrerlesao pessoal e ou dano no equipamento<br />

ATEN AO Este inversorcontem peyas e conjuntos sensfveis a ESD<br />

Electrostatic Discharge Descarga Eletrostatica Precauyoes de controle da<br />

estatica saDnecessarias durante a instalayao testes serviyos de manutenyao ou<br />

reparosdeste conjunto Se os procedimentos de controle da ESD nao forem<br />

observados poderao ocorrerdanos nos componentes Caso voce nao esteja<br />

familiarizado com os procedimentos de controle estatico consulte a Publicayao<br />

8000 4 5 2 da A B Guarding Against Electrostatic Damage ou quaIquer<br />

outro manual de proteyao adequado contra aESD<br />

ATEN AO Urn inversorindevidamente utilizado ou instalado pode causar<br />

danos nos componentes ou a reduyao da vida utiI do produto Erros de fiayao e<br />

aplicayao tais como 0 subdimensionamento do motor alimentayao de energia<br />

CA incorreta ou inadequada ou temperaturas ambientes excessivas podem


Portugues 2<br />

Considera 6es de Montagem<br />

Monte 0 inversor verticalmente sobre uma superffcie lisa vertical e nivelada<br />

Gablnete Tamanho dos Torque de aperto Trilho DIN<br />

parafusos<br />

B M4 8 32 1 56 1 96 N m 14 17 lb pol 35mm<br />

C M5 10 24 2 45 2 94 N m 22 26 lb pol<br />

Proteja 0 ventilador de resfriamento evitando a penetra9ao de poeira ou<br />

partfculas metiilicas<br />

Nao exponha a atmosferas corrosivas<br />

Proteja contra a umidade e luz solardireta<br />

Espa amentos minimos de montagem<br />

Consulte a pagina 16 quanta as dimensoes de monlagem<br />

v 0 V<br />

120mm<br />

4 7 po<br />

o<br />

odobo odobo<br />

6 600 tpoo<br />

0 0<br />

0<br />

120mm<br />

4 7 po<br />

i<br />

0<br />

I II I<br />

lOP9iio entre<br />

de montagem A<br />

Nao requer espa mento<br />

os mversores<br />

OP9iiO de montagem B<br />

Temperaturas do ambiente de opera ao<br />

I<br />

o<br />

odobo<br />

tpoo<br />

0<br />

1oweIfI1 i<br />

25mm<br />

1 l Opo<br />

V 0<br />

120mm<br />

4 7 po<br />

odobo<br />

tpoo<br />

0<br />

o 0<br />

120mm<br />

4 7 po<br />

Ir Jil I I<br />

Temperaturas do ambiente Classifica9iio do gabinete Espa9amentos mfnimos de<br />

Minimo Maximo montagem<br />

IP 20ffipo aberto Use a OP9iio de montagem A<br />

40 C 104 F<br />

10 C 14 F IP 30 NEMA 1 UL Tipo 1 1 Use a OP9iio de monlagem B<br />

SO C 122 F IP 20ffipo aberto Use a OP9iio de montagem B<br />

1 A c1assifica9iio requer a instala9iio de urn kit opcional PowerFlex 40 IP 30 NEMA 1 UL Tipo 1<br />

Requisitos gerais de aterramento<br />

Atendimento a norma CE<br />

Importante Retire 0 MOV para 0 jumper de aterramenlo se 0 inversor<br />

estiver instalado em urn sistema de distribui9iio niio aterrado<br />

Aperte 0 parafuso ap6s a remo9iio do jumper<br />

Consuite 0 Manual do Usuario do PowerFlex 40 no CD que acompanha 0<br />

inversor quanto aos detalhes sobre como cumprir as Diretrizes de Baixa Tensiio<br />

LV e de Compatibilidade Eletromagnetica EMC


Classifica 6es do inversor<br />

Numero de<br />

catalogo<br />

Especifica oes fustveis e di juntores<br />

Classifica 6es<br />

de saida Classlfjca 6es de entrada Prote odo circultode deriva iio<br />

Conta ores<br />

22B V2P3Nl04 04 0 5 2 3 90 132 1 15 9 0 15 140M C2E C16 100C12 30<br />

22B V5PON104 0 75 1 01 5 0 90132 245 20 3 35 140M D8E C20 100C23 56<br />

22B V6PON104 1 1 1 51 6 0 90 132 3 0 24 0 40 140M F8E C32 100 C37 70<br />

200 240V CA 10 entrada 1 monofasica O 230V saida trifasica<br />

22B A2P3Nl04 0 4 0 5 2 3 180 264 1 15 6 0 10 140M C2E B63 100C09 30<br />

22B A5PON104 0 75 1 0 5 0 180 264 245 12 0 20 140M C2E CI6 100 C12 55<br />

22B A8PON104 1 5 2 0 8 0 180 264 4 0 180 30 140M D8E C20 100C23 80<br />

22B A012Nl04 2 2 3 01 12 0 180 264 5 5 25 0 40 140M F8E C32 100C37 If 0<br />

200 240V CA 10 entrada lrlfaslca O 230V salda trlfasfca<br />

22B B2P3Nl04 0 4 0 5 2 3 180264 1 15 2 5 6 140M C2E B40 100C07 30<br />

22B B5PON104 0 75 1 0 5 0 180264 245 57 10 140M C2E Cl0 lOoC09 55<br />

22B B8PON104 1 5 2 0 8 0 180264 4 0 9 5 15 140M C2E C16 100C12 80<br />

22B BOI2Nl04 2 2 3 0 12 0 180264 5 5 15 5 25 140M C2E C16 100C23 115<br />

22B B017N104 3 7 5 0 17 5 180 264 8 6 21 0 35 140M F8E C25 100 C23 165<br />

22B B024Nl04 5 5 7 5 24 0 180 264 11 8 26 1 40 140M F8E C32 100 C37 226<br />

22B B033Nl04 7 5 10 01 33 0 180 264 16 3 34 6 60 140M G8E C45 100 C60 290<br />

380 480V CA 10 entrada trifaslca O 460V saida trifasica<br />

22B D1P4Nl04 0 4 0 5 14 342 528 1 4 1 8 3 140M C2E B25 100C07 30<br />

22B D2P3N104 0 75 1 01 2 3 342 528 2 3 3 2 6 140M C2E B40 100C07 40<br />

22B D4PON104 1 5 2 01 4 0 342 528 4 0 57 10 140M C2E B63 10O C09 60<br />

22B D6PON104 2 2 3 0 6 0 342 528 5 9 7 5 15 140M C2E C10 100C09 90<br />

22B D010Nl04 4 0 5 0 10 5 342 528 10 3 13 0 20 140M C2E CI6 100C23 150<br />

22B DOI2Nl04 5 5 7 51 12 0 342 528 11 8 14 2 25 140M D8E C20 l00C23 160<br />

22B D017Nl04 7 5 10 0 17 0 342 528 16 8 184 30 140M D8E C20 100C23 200<br />

22B D024Nl04 11 0 15 01 24 0 342 528 234 260 50 140M F8E C32 lOO C43 285<br />

460 600V CA 10 entrada lrlfllslca O 575V salda trifaslca<br />

22B El P7N104 075 1 01 1 7 414 660 2 1 2 3 6 140M C2E B25 100C09 40<br />

22B E3PON104 1 5 2 0 3 0 414 660 3 65 3 8 6 140M C2E B40 100C09 60<br />

228 E4P2Nl04 2 2 3 01 4 2 414 660 5 2 5 3 10 140M C2E B63 100C09 90<br />

22B E6P6Nl04 4 0 5 0 6 6 414660 8 1 8 3 15 140M C2E ClO lOoC09 150<br />

22B E9P9N 1 04 5 5 7 5 9 9 414 660 12 1 11 2 20 140M C2E CI6 100C16 160<br />

228 E012Nl04 7 5 10 0 122 414 660 14 9 137 25 140M C2E CI6 100C23 200<br />

22B EOI9N 1 04 11 0 15 0 19 0 414 660 23 1 24 1 40 140M 08E C25 100C30 285<br />

1<br />

Portugues 3<br />

Dlsslpa o<br />

de energla<br />

IP20 aberto<br />

Waifs<br />

Os inversores monofasicos de 200 240V CA tambem se encontram disponiveis com um filtro integral EMC<br />

osufixo no catalogo muda de Nl04 para N114<br />

2<br />

Consulte 0 Guia de Sefe9iiodos Protetores do Motor do Bulletin 140M publica ao 140M<br />

SG001 para<br />

determinar 0 gabinete e a capacidade de frenagem necessarios para a sua aplica9ao


Portugues 4<br />

i gf iff g gr 3 V CC 3 OA a 12SV CA 3 OAa 240V CA<br />

Classiliea o indutiva O 5A a 30V CC O SA a 12SVCA O SAa240V CA<br />

Fusiveis e disjuntores<br />

Tipo de fuslvel recomendado UL Classe J CC T ou Tipo SS88 600V S50V au equivaiente<br />

Disjuntores reeomendados Disjuntores HMCP ou equlvalentes<br />

Recursos de prote9iio<br />

UL508C e CSA22 C<br />

EMcrn i9i336<br />

LV EN 50178 EN 60204<br />

EMC EN 616003EN 50081 1 EN 50082 2<br />

Saidas 6ticas<br />

30V CC SO mA<br />

Naoindutiva<br />

Saldas anat6glcas 10bits<br />

0 10V lkohm Min<br />

420 mA S25 ohm Max<br />

Proteplio do motor Prole oconlra sobreearga 121 1S0 para 60 segundos 200 para 3 segundos olerece p ole o Classe 101<br />

Sobreeorrente 200 Iimile de hardware 300 lalha instantanea<br />

Sobretensao Entrada de 1 00 120V CA Disparo ocorre na lensao de barramenlo de 40SV CC eqUiValenle a linha de enlrada de IS0V CA<br />

Entrada de 200240V CA Disparo oeorre na tensao de barramento de 40SV CC equivalenfe a linha de entrada de 290V<br />

Entrada de 380460V CA Disparo CAl<br />

oeorre na tensao de barramento de 81OV CC equivalente a Iinha de entrada de 575VCA<br />

Entrada de 460 6OOV CA Disparo ocorre na lensao de barramento de 1005V CC equivalenle a Iinhade entrada de 711V CA<br />

Subtensao Enlrada de 10D 120V CA Disparo ocorre na tensao de barramento de 210VCC<br />

leqUivalente a Entreda de 200 240V CA<br />

linhade enlrada de 75V CA<br />

Disparo oeorre na lensaode barramento de 210VCC equivalente a Iinhade entrada de 150V CA<br />

Entrada de 380 480V CA Dispare ocorre na lensaode barramenlo de 390V CC equivalente a linhade enlrada de 275V CA<br />

Entrada de 46O 6OOV CA SeP042 3 Alialensao 0 disparo OlXlrre na tensao de banamento de 487V CC linhade entrada de 344V CA<br />

SaP042 2 Baixo tansao 0 dispam ooorre na tensAode barramento de 390V CC Oinha deentrada de 27SV CA<br />

Percurso Ride Threugh de controle 0 percursomlnlmo e de 0 5 segundo valor tlpico de2 segundos<br />

Percurso Ride Through de energla sem falha 100 mllissegundos<br />

Frenagem diniimica<br />

IGBT de Irenagem interna neluldo com lodas as elassilica oes Consulle 0 A ndice B doManual do Usuario do Powerflex40 no CD quanlo e<br />

jnforma 6es pars pedidos do resistor de FD


Fia ao eletrica<br />

Classilica iio dos lios de lor a<br />

THHNfTHWN sem blindagem 600V 75 c 167 F<br />

RHH RHW 2 blindado de 600V 75 c ou 90 c 167 F ou 194 F<br />

RHH RHW 2 suporte blindado com classifica9iio de 600V 75 c<br />

ou 90 c 167 F ou 194 F<br />

Bloco de terminais de for a<br />

Gabinete B<br />

RILl SIL2 T1L3 UIT1<br />

Terminal 1 Descri iio<br />

RlL 1 S L2 Entrada monofasica<br />

RlL1 S L2 T L3 Entrada trifasica<br />

Portugues S<br />

Fiode cobre recomendado<br />

15 Mils isolado local seco<br />

Anixter OLF 7xxxxx<br />

Belden 29501 29507 ou<br />

equivalente<br />

Anixter 7V 7xxxx 3G<br />

Shawflex 2ACD 3ACD ou<br />

equivalente<br />

CC CC SR SR @ @<br />

UfT1 Para 0 motor UfT1<br />

rn Troque quaisquerdois VfT2<br />

WfT3<br />

Para 0 motor VfT2<br />

Para 0 motor WfT3<br />

fios<br />

do motor para mudar 0<br />

sentido de avan90<br />

P2 P1<br />

Conexiio do indutor de barramento CC somente nos inversores com gabinete C<br />

oinversor com gabinete C e remetido com um jumper entre os<br />

terminais P2 e P1 Remova este jumper apenas quando for<br />

conectado um indutor de barramento ee 0inversor nao energizara<br />

sem a coneXao do jumper ou do indutor<br />

CC CC Conexiio de barramento CC<br />

BR BR Conexao do resistor de freio dinamico<br />

@ Aterramento de Seguran9a PE<br />

1<br />

Importante Os parafusos de terminais podem afrouxar durante 0 transporte Certifique se de<br />

que todos os parafusos de terminais estejam apertados com 0 torque recomendado antes de<br />

energizar 0 inversor<br />

Espeeifiea lies do bloeo de terminais de for a<br />

Gabinete Bitola maxima do lio 2 Bitola minima do lio 2<br />

Torque<br />

B 5 3 mm2 10 AWG 1 3 mm2 16 AWG 1 7 2 2 N m 16 19 lb pol<br />

C 84mm2 8 AWG 1 3 mm2 16 AWG 2 9 3 7 N m 26 33 lb pol<br />

2 Bitolas maximaminima que 0 bloco de terminais aceitara isto nao e uma recomenda9aO


Portugues 6<br />

Condigoes da potencia de entrada<br />

Condi 80 da potencia de entrada A 80 corretiva<br />

Baixa impedfmcia da linha inferior a 1 da reatancia de Instale um reator de linha l<br />

linha ou transformador de isolamento<br />

Transformador de alimenta980 maior do que 120 kVA<br />

ou indutor de barramento somente<br />

inversores de 5 5 11 kW 7 5 15 HP<br />

A Ijnha possui capacitores de corre980 do fator de Instale um reator de linha<br />

potencia ou transformador de isolamento<br />

A Iinha apresenta interruP96es frequentes de energia<br />

A linha apresenta picos de ruldo intermitentessuperiores a<br />

6000V relampago<br />

A tens80 lase terra ultrapassa 125 da tensao normal de Retire 0 MOV jumper terra<br />

linha a linha ou instale um transformador de<br />

isolamento com secundario aterrado<br />

Sistema de distribui9aO nao aierrado<br />

se necessario<br />

Conligura9ao delta aberta de 240V stinger leg<br />

Instale um realor de linha<br />

1 Consulte 0 Apendice B do Manual do Usuario do PowerFlex 40 em CD quanta a informa96es para<br />

pedidos de acess6rios<br />

Recomenda oes para a fia ao de E1S 2<br />

Tipo s de fio s Descri980 Classilica980 mInima<br />

de Isolamento<br />

Belden 8760 9460<br />

ou equiv<br />

0 8 mm2 18AWG<br />

com dreno<br />

partorcido blindagem de 100<br />

300V<br />

60 graus<br />

Belden 8770 0 8 mm2 18AWG 3 condutores blindagem<br />

C<br />

140 graus F<br />

somente para potenci6metro remoto<br />

ou equiv<br />

2 Se os fios forem curtos e estiverem contidos em um gabinete sem circuitos sensiveis 0 uso de<br />

fio blindado talvez nao seja necessario mas e sempre recomendado<br />

Especifiea oes do bloeo de terminais de E1S<br />

Gablnete<br />

BeC<br />

Bitola maxima do lio 31 Bitola mInima do fio 31<br />

Torque<br />

1 3 mm2 16 AWG 0 13 mm2 26 AWG 0 5 0 8 N m 4 4 7 lb pol<br />

3 Maximo mlnimo que 0 bloco de terminais aceitara isto nao e uma recomenda9iio<br />

Consulte 0 Manual do Usudrio do PowerFlex 40 em CD quanto as<br />

recomenda9oes de potencia maxima e comprimento do cabo de contrale


1<br />

Rei N O<br />

normaimente aberto<br />

Comum do rei<br />

Rei N C<br />

nonmalmente feehado<br />

Bloco determinais decontrole<br />

Diagrama de blotos da fia ao de controle<br />

Ativar jumper 4<br />

Rl<br />

R2<br />

30V CC 125V CA 240V CA<br />

Resi ivo 3 OA 3 OA 3OA<br />

Indutlvo O 5A 05A O 5A<br />

I<br />

I<br />

f<br />

I<br />

I<br />

I<br />

I<br />

24V<br />

01<br />

02<br />

03<br />

04<br />

05<br />

06<br />

07<br />

08<br />

09<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

Fla iio<br />

Parada 1 SRC lipica<br />

W<br />

partidalO era o<br />

2<br />

PARA A RENTE<br />

Direciio Opera<br />

Comum digilal<br />

Enlrada dlgilal1<br />

Enlrada digital 2<br />

Entrada digital 3<br />

Entrada digilal 4<br />

Comum 6tico<br />

24V CC<br />

10V CC<br />

o REV<br />

Entrada de 010 V I<br />

ou 10V<br />

I<br />

Comum anal6gico<br />

I<br />

I I<br />

Portugues 7<br />

o<br />

Enl de4 20mA<br />

polenei6metro<br />

deve ser<br />

1 Ok ohm<br />

Saida anal6gica 2 Watt Min<br />

3<br />

Comum<br />

Salda 6tica 1<br />

o24V<br />

i<br />

I<br />

I<br />

R3<br />

17<br />

Saida 61iea 2<br />

30VCC<br />

18<br />

SOmA<br />

induliva<br />

IjNii<br />

19<br />

Biindagem RS485 DSI<br />

i<br />

i 1 0<br />

f8l1 Seleciio de saida anal6gica<br />

V<br />

01 02 03 04 OS 06 07<br />

V020 mAlJi<br />

aD aD aD aD aD<br />

Ativar jumper<br />

ENBL<br />

08 09<br />

rl<br />

f81<br />

SRC EJ<br />

Importante 0Terminal de E1S 01 e sempre uma<br />

entrada coast ate parada exceto quando P036<br />

Fonte de partida estiver configurado para controle<br />

de 3 tios No controle de 3 tios 0 terminal de<br />

E1S 01 econtrolado pelo P037 Modo de parada<br />

Todas as demais tontes de parada sac confroladas<br />

pelo P037 Modo de parada<br />

1<br />

Importante 0inversor e remetido com um jumper instalado entre os terminais de E1S 01 ell Retire este<br />

jumper ao usar 0 terminal de E S Ot como uma entrada de parada ou de ativayao<br />

2 0controle de dois fios esta ilustrado Para 0 contrale de 3 fios use umaentrada momentanea no Terminal<br />

3<br />

4<br />

de E1S 02 para controlar uma partida Use uma entrada mantida ifo para 0 Terminal de E1S 03 para mudar 0<br />

sentido<br />

P036 Fonte de Parada Parada do terminal de<br />

partida ElSOl<br />

Teclado De acorna com 0P037 Coast<br />

3Fios De acordo com 0 P03l De acordo com0 P037<br />

2 Fios De aCQrdo com 0 P037 Coast<br />

Porta RS485 DeBoordO com 0 P037 Coast<br />

Ao utiiizar uma saida 6tica com uma carga indutiva como um rele instale um diodo de recuperayao paralelo ao<br />

rele conforme indicado para evitar danos na saida<br />

Quando 0 jumper ENBL for removido 0 terminal de E1S 01 sempre agira como uma ativayao de hardware<br />

causando uma coast reduyao da velocidade ate a parada Consulte 0 Manual do Usuario do PowerFlex 40 em<br />

CD para intormayoes adicionais<br />

4


Portugues S<br />

Designa<br />

oes dos terminais de E S de contrale<br />

No Sinal Default Descri iio Parametros<br />

Rl Rele N C Falha Conlalo normalmenle aberto para rele desalda A055<br />

normalmente aberto<br />

R2 Comum do rele Comum para rele de salda<br />

R3 Rele N C Falha Conlato normalmenle feehado para rele de salda A055<br />

normalmenle fechado<br />

Chave DIP de sele iio<br />

dasalda anal6giea<br />

Chave DIP<br />

de SinkSource<br />

01 Parada l<br />

0 10V Configura asaida anal6gica para tensiio ou corrente 0 ajuste deve<br />

corresponder aoA065 Sel Saida AnaI6g<br />

Source SRC Fonle As enlradas podem ser inslaladas como Sink SNK Dissipador ouSource<br />

SRC Fonle atraves da configura oda wave DIP<br />

Coast Deve haver um jumper instalado em labrica ou umaenlrada<br />

normalmenle<br />

1<br />

P036 leehada para que aopera iio do inversor inicie<br />

02 PartidalOpera iio Inativa C comando vem de um leelado integral por delaull P036 P037<br />

PARA A FRENTE Para desalivar aopera o em reverso consulle A095<br />

03 Dire aoCpera o REV Inaliva<br />

DesaI reversaol<br />

04 Comum digilal Para enlredas digilais Isolado elelronicamente com enfradas<br />

digilais apartir daE1S anal6gica esaidas 6ticas<br />

05 Entrada digital 1 Freq pre conligurada Programar com A0511Sel Enl Digllallj A051<br />

06 Enlrada digilal 2 Freq pre configurada Programar com A052 Sel Ent DigilaI2 A052<br />

07 Enlrada digilal 3 Local Programar com A053 Sel Enl DigilaI3 A053<br />

P036 P037<br />

A095<br />

08 Enlrada digital 4 Jog para Irente Programar com A054 Sel Enl Digital41 A054<br />

09 Comum 61ico Para saidas 61icas aeopladas Isolado elelronieamenle com<br />

saidas 6ticas apartir da E1S anal6gica e enlradas digitais<br />

11 24V CC Relativaao comum digital<br />

For a para enlradas digilais suprida pelo inversor<br />

A correnle de saida maxima e 100 mA<br />

12 10V CC Relaliva aocomum anal6gico P038<br />

13 Enl tl0V 2<br />

For a suprida pelo inversor para polenei6melro ex1ernode<br />

0 10V<br />

Aeorrenfe de salda maxima e 15 mA<br />

Inativa Para alimenta ode enlrada impediincia de enlrada lOOk P038<br />

ohms ex1ernade 0 10V unipolar ou tl0V bipolar ou bra o A051 A054<br />

de conlalo do polenei6melro<br />

A123 A132<br />

14 Comum anal6gieo Para Enl de 0 1 OV ou Enl de4 20 mA Isolado<br />

eletrenicamente com enlradas esaldas anal6gleas apartir da<br />

15<br />

Ent de 4 20 mA 2<br />

E1S digilal esaidas 6ficas<br />

Inativa Para alimenta ode enlrada ex1erna da4 20 mA P038<br />

impediineia de entrada 250 ohms A051 A054<br />

16 Saida anal6gica FreqSaida 0 1 0 A salda anal6gica de delault eO I OV Para converter a um A065 A066<br />

valor corrente mude aehave DIP de sele oda saida<br />

anal6giea para 0 20 mA pregramar com A0651Sel Salda<br />

AnaI6g 0 valor anal6gico maximo pode ser graduado cOm<br />

A066 Saida Anal6g Sup<br />

Carga maxima 4 20mA 525 ohms 10 5V<br />

0 10V lk ohm 10 mAl<br />

17 Salda 6tica 1 Molor em Programar com A058 Sel Salda 6lieal A058 A059<br />

funcionamento<br />

A064<br />

18 Salda 61iea 2 Na frequeneia Programar com A061 Sel Salda 6Iica2 A061 A062<br />

A064<br />

19 Blindagem RS485 o terminal deveser conectado aoaterramento PE de<br />

DSI seguran aao usara portade comunica o RS485 DSI<br />

1<br />

Consulte as notas de rodape 1 e 4 na pagina 7<br />

21 Ent de 0 10V e Ent de 4 20 mA sao canais de entrada distintos e podem ser conectados simultaneamente<br />

As enlradas podem ser usadas independentemenle para 0 contrale de velocidades ou juntas durante a opera9ao<br />

no modo PID<br />

A132


o<br />

o<br />

o<br />

o<br />

Prepare se para a energiza ao do inversor<br />

Portugues 9<br />

ATENl AO Deve se aplicar for9a ao inversor para realizar os procedimentos<br />

de energiza9ao a seguir Algumas das tensoes presentes se encontram no<br />

potencial da linha de entrada Para evitar 0 perigo de choque eletrico ou danG no<br />

equipamento 0 procedimento a seguir deve serrealizado somente por pessoal<br />

qualificado Leia atenciosamente e compreenda 0 procedimento antes de iniciar<br />

Caso nao ocorra urn evento durante a realiza9ao desse procedimento Nao<br />

prossiga Remova toda a for4t3 incluindo as tensoes de controle fomecidas<br />

pelo usuario Podem haver tensoes fomecidas pelo usuario mesmo quando a<br />

for9a principal CA nao estiver aplicada ao inversor Corrija a avaria antes de<br />

continuar<br />

Antes de aplicar a for a ao inversor<br />

1 Certifique se de que todas as entradas estejam conectadas aos terminais<br />

corretos e de que estejam seguras<br />

2 Verifique se a for9a da linha CA no dispositivo de desconexao esta dentro do<br />

valor nominal do inversor<br />

3 Certifique se de que toda for9a de controle digital seja de 24 volts<br />

4 Verifique se chave DIP de configura9ao do Sink SNK Source SRC esta<br />

configurada para corresponder ao esquema de fia9ao de controle Consulte a<br />

pagina 7 quanto a localiza9ao<br />

Importante b esquema de controle de default e Source SRC 0 terminal de<br />

Parada e ligado em ponte terminais de E S 01 eII para permitir a<br />

inicializa9ao a partir do teclado Se 0 esquema de controle for<br />

mudado para Sink SNK 0jumper deve serremovido dos<br />

terminais de ES 01 e II e instalado entre os terminais de E S<br />

01 e 04<br />

o 5 Verifique se ha uma entradade Parada caso contrario a opera9ao do inversor<br />

nao inicializara<br />

Importante Se 0 Terminal de E S 01 for usado como umaentrada de parada<br />

deve se remover0 jumper entre os Terminais de E S 01 e 11<br />

Aplica aodefor a ao inversor<br />

o 6 Aplique tensoes de controle e for9a CA para 0inversor<br />

o 7 Familiarize secom os recursos do teclado integrado consulte a pagina<br />

seguinte antes de configurar quaisquer parametros do Grupo de<br />

Programa9ao<br />

Controle de partida parada sentido e velocidade<br />

Os valores de default de fabrica dos para metros permitem controlar 0 inversor a<br />

partir do teclado integral Nenhuma programa9ao e necessaria para dar a partida<br />

parar mudar 0 sentido econtrolar a velocidadediretamente do teclado integral<br />

Importante Para desativar a opera rao<br />

reversao<br />

em reverso consulte A095 DesaI<br />

Se ocorrerumafalha durante a energiza rao consultea pagina 17 uma para<br />

explica9ao do c6digo de falha Para informa roes completas sobre aidentifica9ao e<br />

solu rao de problemas consulte 0Manual do Usudrio do PowerFlex 40 no CD<br />

que acompanha 0 inversor


Portugues 10<br />

Teclado integral<br />

FAULT<br />

00 00<br />

@ @8<br />

80<br />

10<br />

CD Q 10<br />

No LED Estado do LED Descri iio<br />

Menu Descrl ao<br />

d<br />

P<br />

R<br />

Grupo dedisplay somentevlsuallza9iio<br />

Consiste nas condi oes de opem odoinversor<br />

comumente visualizadas<br />

Grupo de programa9iio biislea<br />

Consisle nas fun oes programaveis mals comumente<br />

ulilizadas<br />

Grupo de pregrema o avan9ada<br />

Consisle nas demais fun oes progmmiiveis<br />

F De lgnadorde lalha<br />

Consisle na Iista de c6digos pam<br />

condi lles de falhas<br />

especlficas Exibido somente quando houvor uma falha<br />

0 Status de operayiio Vermelho Indica que 0 inversor esta em operayiio e 0 sentido comandado do<br />

sentido constante motor<br />

Vermelho oinversor foi comandado a mudar de sentido Indica 0 sentido efetjvo<br />

piscando do motor enquanto esta desacelerando para zero<br />

@ Display Vermelho Indica 0 numero do parametro valor do parametro ou c6digo de falha<br />

alfanumerico constante<br />

Vermelho Se apenas um dfgito estiver piscando isto indica que 0 dlgito pode ser<br />

piscando editado<br />

Se todos os dfgitos estiverem piscando indica uma condiyiio de falha<br />

8 Unidades exibidas Vermelho Indica as unidades do valor do parametro que esta sendo exibido<br />

constante<br />

0 Status de Vermelho Indica que o valor do parametro pode ser alterado<br />

programaciio constante<br />

0 Status de falha Vermelho Indica que houve falha noinversor<br />

piscando<br />

0 Status do Verde constante Indica que 0 potenciemetro no teclado integral esta ativo<br />

potenciemetro<br />

8 Status da tecla de Verde constante Indica que a tecla de partida<br />

partida do teclado integral esta ativa<br />

A tecla reverse tambem estara ativa exceto se for desativada pelo<br />

A095 DesaI reversao<br />

No Tecla Nome Descri iio<br />

0 Escape Voila uma etapa no menu de programa iio<br />

Cancela urna alteraciio no valor do par metro e sai do Modo de<br />

Programacao<br />

0<br />

@ Selecao Avanca uma etapa no menu de programacao<br />

Seleciona um digito ao visualizar um valorde parametro<br />

wGD Seta para cima Movimenta se pelos grupos e Seta para baixo<br />

parametros<br />

Aumentaldiminui 0 valor do dfgito que esta piscando<br />

8 Enter Avanca uma etapa no menu de programaCao<br />

Salva uma alteracao no valor do para metro<br />

0 Potenciernetro Usada para controlar a velocidade do inversor 0default e ativo<br />

Controlado pelo parametro P038<br />

CD Partida Usada para dar partida no inversor 0default e ativo<br />

Controlado pelo parametro P036<br />

QJ<br />

Reverso Usada para inverter 0 sentido do inversor 0default e ativo<br />

Controlada pelos parametros P036 e A095<br />

Parada Usada para parar 0 inversor ou remover uma falha<br />

Esta tecla esta sempre ativa<br />

Controlada pelo parametro P037


Etapa<br />

Portugues 11<br />

Visualiz aoe edi ao deparametros<br />

oultimo parametro de Grupo de Display selecionado pelo usuario sera salvo quando a forya for<br />

nimovida e sera exibido por default quando a forya for aplicada novamente<br />

A seguir um exemplo das funyoes basicas do teclado integral e de display Este exemplo fornece<br />

instruyoes basicas de navegayao e ilustra como programar 0 primeiro parametro do Grupo de<br />

Programayao<br />

1 Quando a forya for aplicada 0 ultimo numero de<br />

parametro do Grupo de Display selecionado pelo<br />

usuario e exibido brevemente com os caracteres<br />

piscando 0 display entao retorna ao valor atual do<br />

parametro 0exemplo indica 0 valor de d001 Freq<br />

saida com 0 inversor parado<br />

2 Pressione Esc uma vez para exibir 0 numero de<br />

parametro do Grupo de Display que aparece durante a<br />

energizayao 0numero do parametro piscara<br />

3 Pressione Esc novamente para entrar no menu do<br />

grupo A letra correspondente ao menu de grupo<br />

piscara<br />

4 Pressione a seta para cima ou seta para baixo para<br />

movimentar se pelo menu do grupo d PeA<br />

5 Pressione Enter ou Sel para entrar em um grupo 0<br />

digito da direita do ultimo parametro visualizado<br />

naquele grupo Ira piscar<br />

6 Pressione a seta para cima ou seta para baixo para<br />

movimentar se pel os parametros que estao no grupo<br />

7 Pressione Enter ou Sel para visualizar 0 valor de um<br />

parametro Caso nao deseje editar 0 valor pressione<br />

Esc para retornar ao numero do parametro<br />

8 Pressione Enter ou Sel para entrar no modo de<br />

programayiio para editar0 valor do parametro 0<br />

digito da direita piscara e 0 LED de Programacao<br />

acendera se 0 parametro puder ser editado<br />

9 Pressione a seta para cima ou seta para baixo para<br />

mudar 0 valor do parametro Se desejado pressione<br />

Sel para movimentar se de digito a digito ou bit a bit<br />

odlgito au bit que voce pode mudar ira piscar<br />

10 Pressione Esc para cancelar uma mudanya 0dfgito<br />

parara de piscar 0 valor anterior serarestaurado e 0<br />

LED de ProgramayaO se desligara<br />

Ou<br />

Pressione Enter para salvar amudanca 0digito<br />

deixara de piscar e 0 LED de Programayao se<br />

desligara<br />

11 Pressione Esc para retornar it isla de parametros<br />

Continue pressionando Esc para sair do menu de<br />

programayiio<br />

Caso 0 display nao mude quando voce pressionar a<br />

tecla Esc sera exibido d001 Freq safda Pressione<br />

Enter au Sel para entrar no menu do grupo<br />

Tecla s<br />

Wou@<br />

@lou@<br />

0ou@<br />

@lou@1<br />

@lou@1<br />

aou@<br />

@l<br />

Exemplos de display<br />

I<br />

PROGRAM FAULT<br />

o 0<br />

a al i<br />

Id 0a Hi<br />

PROGRAM FAULT<br />

o 0<br />

raaa<br />

PROGRAM FAULT<br />

o 0<br />

10<br />

VOLTS<br />

0 AMPS<br />

o HERTZ<br />

P a 3 i<br />

PROGRAM FAULT<br />

o 0<br />

2 3 al i<br />

PROGRAM FAULT<br />

o 0<br />

2 3 Q i<br />

PROGRAM FAULT<br />

0<br />

12 2 Inl<br />

PROGRAM<br />

o<br />

FAULT<br />

o<br />

VOLTS<br />

oAMPS<br />

0 HERTZ<br />

IP 0 3 mi<br />

PROGRAM FAULT<br />

o 0


Portugues 12<br />

Consulle 0 Manual do Usuario do PowerFlax 40em CD para inlormaooes adieionais sobre os parAmetros<br />

Parametros do grupo dedisplay<br />

No ParAmelro MinIMax Display Op 6es<br />

dool Freq saida 0 01 Freq maximal 0 1 Hz<br />

d002 Freq comandadal 0 0 Freq maxima 0 1 Hz<br />

d003 ICorrente saida O OO Corrente do jnversor x 2 01 Amp<br />

d004 Tenseo de saidal OlTensao nominal do inversor 1 VCA<br />

d005 Tensao barram CCJ Baseado na classificayao do<br />

inversor<br />

1 VCC<br />

d006 Slalus inversor 011 1 Condi ao verdadeiral Ilil 3 Bi12 Bill JliUl<br />

Desacelerand Acelerando Para frente Opemndo<br />

d007 C6digo lalha x F21FI22 Fl<br />

d009<br />

dOlO Display proeessol 0 0019999 0 01 1<br />

d012 IFonle eonlrole 019 Bit 1 Comando de velocidade Bit Q Comando de partida<br />

ConsuMe P038 9 Freq Jog Consulte P036 9 Jog<br />

d013 Status enl cnlrl 0 1 1 Enlrada presente Ilil 3 Bi12 Bill JliUl<br />

Trans FD Ug Parar Ent DirlEnt REV IniclEnt FRE<br />

d014 Slalus enl dig 0 1 I Enlrada presenlel 1liL3 Bi12 Bill JliUl<br />

Enl digitel4 Enl digitai3 Ent digital2 Enl dignall<br />

d015 Status comunl 011 1 Condi ao verdadeiral Ilil 3 Bi12 Bill IliUl<br />

Erro DSI Tx Rx<br />

d016 Versao SFW 1 00199 99 0 01<br />

dOl Tipo de invorsor 1001 9999 1<br />

dOl8 Tempo deeorndo 019999 Hrs 1 10Hrs<br />

d019 IDados plo teste OIFFFF 1 Hex<br />

d020 Entr Anlg 0 1OV 0100 0 0 1<br />

d021 Entr Anlg 4 20 mAl 0 0 100 0 0 1<br />

d022 Pol de Saida O oo PotAneia do inversorx 2 01 kW<br />

d023 Falor Pol Saidal O Oi1 80 0 graus 0 1 grau<br />

d024 Temp Inv 0 120 graus C 1 grauC<br />

d025 Slalus eontadorl 019999 1<br />

d026 Slalus cronOm 1 0 019999 0 1 Seg<br />

d028 ISlatus L6g Par 07 1<br />

d029 Corrente Torquel O OO Corrente do inversor x 2 0 01 Amp<br />

Energiza ao inteligente com os Parametros Basicos do<br />

Grupo de Programa ao<br />

oPowerFlex 40 e projetado para uma energizayao simples e eficiente 0Grupo de Programa9iio<br />

contem os parametros mais comumente usados<br />

QJ Pare 0 inversor antes de mudar aste parAmetro<br />

No ParAmetro IMfnlMax Dlsplay Op 6es Default<br />

P031 Tensao nominal 120rrensao nominal d inversor 1VCA Baseado na classifica t8o do<br />

Q Configurado na lens onominal da placa de identificacao do<br />

motor<br />

Inversor<br />

P032 Freq nominai 115 400Hz I Hz 60Hz<br />

QJ Conli9uradona freqOAneia nominal da placa de identilica ao<br />

do motor<br />

P033 Sobrecarga motor 10 0 Corrente nominal ioversor x 2 0 1 Amp Baseado na classlficacAo do<br />

inversor<br />

Conflgurado na corrente maxima permitldapara 0 motor<br />

P034 Freq minima 10 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

Estabelece amenor freqO mciaque 0 Inversor produzira<br />

conlinuamenle<br />

P035 Freq maxima 10 400 Hz 1 Hz 60Hz<br />

QJ Eslabelece afreqQlIncla maiselevada que 0 inversor<br />

produzlra<br />

P036 IFonle de partidal 1018 0 Teelado l<br />

0<br />

Q Estabelece 0 esquema de<br />

1 3Iios<br />

controle usado 1<br />

para Iniclar a<br />

operayao do inversor<br />

2<br />

3<br />

2 lias<br />

SenNlv 2ftOs<br />

4<br />

Quando ativo atecla reverso lambem eslan1 ativa exceto<br />

5<br />

AitaVel2fios<br />

Porta Cornun<br />

sa lor desativada palo A095 DesaI reversao 6 Momt FRENTElREV


Consulte 0 Manual do Usuario do PowerFlex 40 em CD para informayaes adicionais sobre os parametros Portugues 13<br />

Q Pare 0lnversor antes de mudar este parametro<br />

No Pariimetro TMinlMax DlsplayOp 6es Default<br />

P037 Modo de parada 1019 0 Rampa Cpll 0<br />

1 Coast Cpll<br />

Modo de parada ativa para todas as fontes deparada Jpor 2 Fren CC Cpll<br />

exemplo tedado<br />

oferafiio para Irente Terminal de E S 02<br />

3 AutoFrCC CPI<br />

operayao reversa ermlnal de E1S 03 porta RS485 exeeto<br />

4 Rampa<br />

como observado abaixo<br />

5 Coasr<br />

Importante 0 Terminal de E1S 01 e sempre uma entrada<br />

de redu oda veloeidade ate a parada coast to stop BXCeto ar 22<br />

quando P036 Fonte de partida estivereonfigurado para<br />

8<br />

controle de 3 tios Quando RmpCntFrEMCP<br />

no controle de 3 flos 0 terminal<br />

9 RmpCntFrEM EIS 01 e eontrolado pelo P037 Modo de parada<br />

1 A entrada da parada tambem remove uma<br />

lalha aliva<br />

P038 Ref veloeidade 10 7 0 Pot Inverso 0<br />

1 Freq Interna<br />

Estabelecea fonte de refertmcia de velocidade para 0<br />

inversor<br />

2 Entrada 0 10V<br />

3<br />

Entrada 4 20 mA<br />

Importante Quando A051 oU A052 Sel Ent Digitalx estiver 4 FreqPre conl<br />

configurado na opyao 2 4 5 6 13 au 14 eaentradadigital 5 Porta Comun<br />

est eraliva A051 A052 A053 au A054 eaneelara a<br />

6 L6g Parada<br />

6 u1 ao f d1a f 6 5 cfoa ex 40 7 MultEntAnlg<br />

em CD para maiores delalhes<br />

P039 Tempo aeelerac 11 0 0 600 0 Segs 0 1 Seg 10 0 Segs<br />

Configura ataxa de acelera o para todos os aumentos de<br />

velocidade<br />

P040 Tempo desaeele 11 10 1 600 0 Segs 0 1 Seg 10 0 Segs<br />

d d<br />

a de desacelera o para todas as reduyaes<br />

P041 Vollar Defaults 10 1 o Prontollnat 0<br />

Q Reconfigura lodos os valores de parAmetros para os valores 1 defabriea<br />

Rest Fabnca<br />

P042 Classe Tens ol 1213 2 Baixa tens o 480VI<br />

Q Eslabelece a c1asse de tensao dos inversoresde 600V 3 Alia tens o 600V<br />

Parametros de grupo avan ados<br />

No Pariimetro MinIMax Display Op 6es Default<br />

A051 Sel Enl Digitall 0126 o N o usado 13 CantEnll0V 4<br />

Terminalde ES 05 1 Acel Desae 2 14 Coni En120 mA<br />

A052 Sel Enl Digilal2 2 Jog 15 Desat PID 4<br />

Terminal de ES 06 3 Faiha Aux 16 Elev MOP<br />

A053 Sel Ent Digilal3 4 Freq Pre conI 5<br />

Terminal de ES07 5 Locar<br />

A054 el Ent Digital4 6 Porta Comun 19 Ent Contado 11<br />

erminal de ES 08<br />

Q<br />

7<br />

8<br />

Rem falha<br />

ParRampa CP<br />

20<br />

21<br />

Reset cron<br />

Reset Contad<br />

9 ParCoas CP 22 RstCron Conl<br />

10 ParlnjCC CP 23 Ent 16gieal<br />

11 Jag pllrente 24 Ent 16gica2<br />

12 Jog reverso 25 UmCorrente2<br />

26 Invers Anal<br />

A055 Sel salda rele 0 22 o ProntolFalha 11 Enl16giea 1 0<br />

1 Na Iraq 12 Ent 16gica 2<br />

r<br />

2 Molor opera 13 L6gica 1 e2<br />

3<br />

4<br />

Reverso<br />

Sobrec motor<br />

1 iEg<br />

2<br />

5 Reg rampa 16 Gron esat<br />

6 Acima freq 17 Cant desal<br />

7<br />

8<br />

Acima corr<br />

Aeima lensCC<br />

1 r<br />

9 Encer lent 20 Con Parllm<br />

10 Aeima V anlg 21 Falha NiioRee<br />

22 CntFrenEM<br />

A056 Nivel saida rele 0 0 9999 0 1 0 0<br />

6tiealj<br />

A058 Sel Saida<br />

0 22 o ProntolFalha 11 Ent 16giea 1 2<br />

A061 Sel Salda 61ica2 1 Na Iraq 12 Ent 16giea 2 1<br />

2 Motor opera 13 L6gice 1 e 2<br />

3<br />

4<br />

Reverso<br />

Sobree moto<br />

1 icgg<br />

2<br />

5 Reg rampa 16 Cron desat<br />

6 Aeima Freq 17 Cant desat<br />

7 Acima corr 18 Aeima PFAnlg<br />

8 Acima tensCC 19 Parda EntAnl<br />

9 Encer tent 20 Contr Paramo<br />

10 Aeima V anig 21 Falha NiioRee<br />

22 CntFrenEM<br />

3


Consulle 0 Manual do Usuariodo PowerFlex 40em CD<br />

para inlorma oes adicionais sobre os paramelros Portugues 15<br />

No Par8metro MInIMax Dlsplay Op oes Default<br />

A079 IAeeVOesaeel Jogl 0 1600 0 Segs 0 1 Sag 10 0 Sags<br />

A080 Tempo Fren CC 10 0 99 9 Segs 0 1 Seg 0 0 Segs<br />

Uma conligurayao de 99 9 Segs Continuo<br />

A081 Nlvel Fren CC O O Cortente do inversor 0 1 Amp Amps x 0 05<br />

xl81<br />

A082 Sel resislor FOJ 0 99 o Desativado 2 Sem Proleyao 0<br />

Q<br />

1 Res RA Normar 3 99 doCicio de servi<br />

A083 CurvaS 0100 1 0 Desalivadol<br />

A084 ISeleyao Relo oJ 0 14 Ajusles em da tensao de base 8<br />

Ativo somenle quando 0A 125 Modo Desemp Torq for 0<br />

configurado em 0 V1Hz<br />

VlHz Person<br />

Toraue constante<br />

7 4 11 kW<br />

5 15 HPI<br />

1 30 0 TV 5 0 0 sem Rr 10 100 TC<br />

2 35 0 TV 6 0 0 11 125 TC<br />

3 40 0 TV 7 2 5 TC 12 15 0 TC<br />

4 45 0 TV 8 5 0 TC 13 17 5 TC<br />

9 7 5 TC 14 20 0 TC<br />

A085 Retoroo partida 10<br />

025 0 0 1 2 5<br />

Alivo somente quando 0A084 Seleyao Reto e0A1251ModO Desemp Torq forem eonfigurados em 0<br />

A086 Tensao Interrupj 10 01100 0 10 1 25 0<br />

Alivo somente quando 0 A084ISeleyao Reto ol e0A125 ModODesemp Torq lorem conligurados em 0<br />

A087 Freq Inlerrup 10 0 400 0 Hz 10 1 Hz 15 OHz<br />

Alivosomenle quando 0 A084 Seleyao ReIO o e0A125 Modo Desemp Torql lorem conligurados em 0<br />

A088 Tensiio maxima 20ITensiio nominal lVCA Tensao nominal<br />

l A089 Umile corr 1 O Corrente do inversor 0 1 Amp Amps x 1 5<br />

xl 8<br />

A090 Sel sobree motor 0 2 o Sem reduoiio 1 ReduOiio min 0<br />

2 RedUoiio max<br />

A091 IFreqOancaPWM 2 0 16 0 kHz 0 1 kHz 4 0 kHz<br />

A092 Tent ReinAutj 0 9 1 0<br />

A093 Ret rein auto 0 01300 0 Sags 0 1 Seg I OSeg<br />

A094 Partida energ 011 o Desativado 1 Ativado 0<br />

QJ<br />

A095 DesaI reversiio 01 o Rev ativado 1 Rev dOSativ 0<br />

QJ<br />

A096 Partid mov ativ 1 0 1 o Desalivado 1 Ativado 0<br />

A097 Compensaoiio 0 3 o Desativado 2 MecAnico 1<br />

1 Elelrieo 3 Ambos<br />

A098 Disparo Carr SW O O Corrente doinversor 0 1 Amp 0 0 Desativado<br />

x2<br />

A099 Fator processol 0 11999 9 0 1 30 0<br />

Al00 Remoyao lalha 012 o Prontollnae 1 Reset lalha 0<br />

QJ<br />

2 Remov buffer<br />

Al01 Bloq pragramayao 019999 o Desbloqueado 1 Bloqueado 0<br />

Al02 Sel ponto teste 400IFFFF 1 Hex 400<br />

Al03 Taxa comun dados 0 5 0 1200 3 r<br />

9600 3<br />

n<br />

e<br />

g rd ndc re cao<br />

1<br />

2<br />

2400<br />

4800<br />

4<br />

5<br />

19<br />

38<br />

21<br />

41<br />

Al04 lEnd n6 comunl 111247 1 100<br />

n<br />

e<br />

g i rd re ns a<br />

r pe cao<br />

Al05 IAyaoperda comunl 0 3 0 Falha 2 Parada 0<br />

1 Parada coast 3 ConI ultima<br />

Al06 Tempo perdaeomunJ 0 1 60 0 Segs 0 1 5 0<br />

l A107 Formato comun 02 0 RTU BN 3 RTU 8 N 2 0<br />

n<br />

e<br />

g rd nd o<br />

1 RTU 8 E l 2 RTU 8 Dl<br />

4<br />

5<br />

RTU BE 2<br />

RTU 8 0 2<br />

Al08 Idioma 1 10 1 English 6 Reservado 1<br />

2 Franyais 7 Portuguas<br />

3 Espanol a Reservado<br />

4 Italiano 9 Reservado<br />

5 Deutsch to Nederlands<br />

Al09 PtoAj Saida Anal 0 01100 0 0 1 0 0<br />

IEntr Anini0 1 OV 0 0 100 0 0 1 0 0


portugues 14 Consulle 0 Manual do UsuMo do PowerFlex 40 em CD para inlorma oes adidonals sobre os parAmetros<br />

No PsrAmetro MInIMax DlsplaylOp 6es Default<br />

A059<br />

INIV Salda<br />

61iealj 10 019999<br />

A062 Nlv Saida 61iea2<br />

Configura ao d A055 A058 A061 A056 A059 A062 MinIMilx<br />

6 01400 Hz<br />

7 01180<br />

8 01815 Volts<br />

10 01100<br />

16 0 19999 Se95<br />

17 19999 Conlagens<br />

18 1 180 graus<br />

20 011<br />

10<br />

1 0 0<br />

A084 L6g Salda OUcal 10 3 11 0<br />

O ao do A064 LOgica d S ida Otica 1 LOgica d S ida Otica 2<br />

0 NO Normalmente aberto NO Normalm nt berto<br />

1 NC Normalmente lechado NO Normatmente sberto<br />

2 NO Normalmente aberto NC Norm lment techado<br />

3 Ne Normalmentefectlado Ne Normalmente fect1ado<br />

A065 Sel Salda AnalOg 10120 l 0<br />

Faixade Velarde Valor de salda mAxlmo Pos Ao de<br />

1<br />

Op llo salda salda minima Saida AnalOg Sup chaw DIP<br />

o FraQS 0 10 010V OV OHz P035 Fr Q mAxim 0 10V<br />

1 CorrSa10 10 0 10V OV OAmp 200 da corrente de carga plenanominal do lnversor 0 10V<br />

2Ten SaI0 10 0 10V OV OVolls 120 da lansao desalda nominal do inversor 0 10V<br />

3 PoIS I 0 10 0 10V OV OkW 200 dapolMcla nominal do lnversor 0 10V<br />

4 OadTsle010 010V OV 0000 65535 Hex FFFF 0 10V<br />

5 FraqS 1 020 0 20 mA OmA OHz P035 Fraq mAxim 020mA<br />

6 CorrS ida 0 20 0 20mA OmA OAmps 200 de corrente decarga plena nominal do lnversor O 20mA<br />

7TensS 1 020 020mA OmA<br />

OVolls 120 de lansAo desalda nominal do inversor O20mA 8 PoIS i 0 20 0 20 mA OmA OkW 200 de potAncia nominaldo inversor O20mA<br />

9 DadTsle 0 20 0 20mA OmA 0000 65535 H x FFFF 0 20mA<br />

10 FreqS i 4 20 4 20mA 4mA OHz P035 Fraq mAximal O20mA 11 CorrS 14 20 4 20mA 4mA OAmps 200 de corrente de<br />

carga plena nomInal do inversor 020mA 12T nsS i4 20 4 20mA 4mA 0 Volt 120 de tenseo de salda nominaldo inversor 020mA<br />

13 PoIS I 4 20 4 20mA 4mA OkW 200 da potAncia nominal do inversor O20mA<br />

14 DadTsI 4 20 4 20mA 4 mA 0000 65535 IH x FFFF 020 mA<br />

15 TorqSal 0 10 0 10V OV OAmps 200 da corrente de carga plena nominal do Inversor 010V<br />

16 0 TorqSal 20 O20mA OmA OAmps 200 da corrente de carga plena nominaldo inversor o20mA<br />

17 TorqSaI4 20 HOmA 4mAcOAmps 200 da corrente de carga plena nominal do inversor 0 20mA<br />

18 PloAj 010 010V OV O 100 da oonfigura ao do ponto d ajUS1 010V 19 PloAj020 0 20mA OmA O 100 da oonfigura ao do ponloda a US1e O20mA 20 PloAj 420 4 20mA 4mA 0 100 da conflgura odo ponto de aJuste 020mA<br />

A066 Salda AnalOg Sup 0 800 1 100<br />

A067 Tempo acelerae 2 0 0 600 0 Segs 0 1 Seg 20 0 Sags<br />

A068 Tempo desacele 21 0 1600 0 Segs 0 1 Seg 20 0 Sags<br />

A069 Freq Infemal 0 0 400 0 Hz 0 1 Hz 60 0 Hz<br />

A070 Freq pre eonfigO 1<br />

0 0 400 0 Hz 0 1 Hz 0 0 Hz<br />

A071 Freq prtkonfigl 50 Hz<br />

A072 Freq pre eonlig2 10 0 Hz<br />

A073 Freq pre eonfig3 20 0 Hz<br />

A074 Freq pre config4 3Q OHz<br />

A075 Freq pre eonlig5 40 0 Hz<br />

A076 Freq pre eonfig6 50 0 Hz<br />

AOn Freq pre config7 60 0 Hz<br />

I<br />

Para ativar a Fraq Pre eonlig 0 configure0 P038 Ref veloeidade na op llo 4<br />

Estado de entrada Eslado de entrada Estado de entrada<br />

da Ent Digital 1 da En Digital2 da Enl DIgllal3 Fonte de<br />

Termnalde Terminal de Terminal de freQ06nci<br />

ElS05 ElS06 ElS07<br />

acelera AoI7er an o<br />

usado 2<br />

0 0 0 Freq pr6 onligO Tempo acelerac 1 1<br />

1<br />

Tempo desacele<br />

0 0 FreQPr6 onfigl Tempo acelerac 1 Tempo desacele 1<br />

0 1 0 FreQPr6 onlig2 T mpo ecelarae 2 Tempo desacele 2<br />

1 1 0 Fraq p Xf1fig3 Tempo acelerac 2 Tempo desacele 2J<br />

0 0 1 Freq p config41 T mpo calerae 111 T mpo dasacel 11<br />

1 0 1 FreQ pre conlig5 T mpo acel raeI T mpo dosecela 1<br />

0 1 1 Freq p conf 6 Tempo aoelerac 2J Tempo desacele 2J<br />

1 1 1 FreQP conlig7 Tempo acelerac 2 Tempo desacele 2<br />

2<br />

Quando uma Entrada Digital forconfigurada em Ace12eDesacele 2 eaentrada estiver ativa ala cancelaas<br />

conligura oes nesta tabela<br />

A078 FreqOencla Jog 10 0 Freq maximal 10 1 Hz 10 0 Hz


Portugues 16 Con suite0 Manual do Usuerio do PowerFlex 40em CDpara inlorma oes<br />

adicionais sobre os parAmelres<br />

No Par6metro MInIMax orsplay Op Oes Default<br />

Alii<br />

Q<br />

IEntrAnSup 0 1 OV 0 01100 0 0 1 1000<br />

A112<br />

Q<br />

EntrAnlnf 4 20 mAl 0 0100 0 0 1 00<br />

A113 EnlrAnSup 4 20 mAj 0 0 100 0 0 1 100 0<br />

Q<br />

A114 IFreq Esc @ I Nom 0 0 10 0 Hz 0 1 Hz 2 0 Hz<br />

A115 lTempo Inl Procesl 0 00199 99 0 01 0 00<br />

A118 lTempo Sup Proees 0 00 99 99 0 01 0 00<br />

A117 Modo Reg Barram 011 o Desativado 1 Ativado 1<br />

A118 Limite carr 2 O II Corrente do inversor 0 1 Amp Amps xlS<br />

xl8<br />

A119 FreqGAnda inib 0 400Hz 1 Hz OHz<br />

A120 Banda Inlb Freq 0 0 30 0 Hz 0 1 Hz DOHz<br />

A121 ITpo FalhaParalisl 0 5 0 60 Segundos 3 360 Segundos 0<br />

1 120 Segundos 4 480 Segundos<br />

2 240 Segundos 5 Fal Desaliv<br />

A122 perda En Anlg 016 o Desativado 4 Rei Freq Mln 0<br />

1 Falha F291 5 Ref Freq Max<br />

2 Parada 6 Ref Freq In<br />

3 Ref Zere<br />

A123 Ent Bipolar 10V 01 o Enf unipola 1 Ent blpola 0<br />

A124 Desat PWM Var 011 0 Ativado 1 Desalivedo 0<br />

A125 Modo Desemp Torql 01 0 V1H1 1<br />

Velor sensrl 1<br />

A126 Correnle Nominall O liCorrenle do inversor x 10 1 Amp Correnle Nominal<br />

A127 Autoajuste 0 2 o Prontonnat 2 Ajusle Rota 0<br />

1 Ajuste Eslel<br />

A128 Queda Tensao RI 0 0 2300 VCA 0 1 VCA Tensao nominal<br />

A129 Rei Corr Fluxol O OO Tensao Nominal 0D1 Amp Corrente Nominal<br />

A130 Ajuste Sup PID 0 01400 0 0 1 60 0<br />

A131 IAjuste Inl PiDI 0 0 4000 0 1 0 0<br />

A132 Sel Rei PIDI 0 8 0 PIDdesaliv 5 AjPtoPfI Conl 0<br />

1 PtoConfg PID 6 Ajusle ol0V<br />

l 2 Entradao OV 7 Alusle4 20 mA<br />

3 Ent 4 20 mA 8 AjusteComun<br />

4 Porta Comun<br />

AI33 Sel Feedback PIDI 02 0 Enol0V 2 Porta Comun 0<br />

1 En4 20 mA<br />

A134 Ganho Prep PID 0 00 99 99 0D1 0 01<br />

A135 lTempo Inleg PiD 0 0 999 9 Segs 0 1 2 0<br />

A136 lTaxa Oil PID O OOi99 99 1 Segsl 0 01 0 00<br />

A137 Ponto ajusle PIDI 0 01100 0 0 1 0 0<br />

A138 Banda morta PiD 0 0110 0 0 1 0 0<br />

A139 Pre Garga PID 0 0 4000 Hz 0 1 Hz 0 0 Hz<br />

A14o ILOgica Parada Q7 0001 bAFF 4dlgitos ooFl<br />

A147 Para uma USIa de<br />

op<br />

es dlgitais consulle 0 Manual doUsuArio<br />

do PowerFlex 40 no 0 que acompanha 0inversor<br />

A150 ITpo L6g Parada 0 7 0 01999 9 Segs 0 1 Seg 30 0 Segs<br />

A157<br />

A160 Freio ElefrmgDes 0 01 10 00 Segs 0 01 Seg 2 00 Segs<br />

A161 Fren Eletmag Atv 0 01 10 00 Segs 0 01 Seg 2 00 Segs<br />

A162 Sel Reset MOP 0 1 0 Ref MOP Zero 1 Salvar Ref MOP 1


C6digos<br />

de falhas<br />

Portugues 17<br />

Para removeruma falha pressione a tecla Stop Parar desligue e volte a ligar ou<br />

configure 0 AIOO Remo ao Falha em 1 ou 2<br />

No Falha Descri iio<br />

F2 EnAuxiliar Verifique a Iia o remota<br />

F3 Perda pol6neia Monitore a linhade entradaCA quanlo a baixa lensaoou interrupyao de for na linha<br />

F4 Subtensao 1<br />

Monitore a Unhade entrada CA quanto a baixa tensao ou inlerrupcao de forca na linha<br />

FS Sobretens60111 Monitore a linhaCA quanta a condi 5es transientes au tansaa elevada da linha A sobrelensao do barramento<br />

tambem pode sar causada pela regenerayao domotor Aumente 0 tempo de desaceleracao au inslale a opyao<br />

de raiodinamico<br />

F6 Molor Travado 1<br />

Aumenle Tempo Acelerac xl ou reduza a carga de forma que a corrente de sarda do inversor nao ultrapasse a<br />

corrente eslabeleeida pelo parAmetro A089 Umile corr 1 j<br />

F7 Sobrecarga Motor He uma carga excessivano molor Reduzaa carga para que a corrente de salda do inversor nao excedaa<br />

eorrenle estabeledda pelo par melro P033 Sobreearga motor<br />

F8 Sobretemp Dissip Verifique sa M alatas sujas ou bloqueadas no dissipador Vefifique se atemperatura ambiente neo ultra<br />

bas sou<br />

40 c 104 F para as instala oes IP 301NEMA 1 UL Tipo 1 au SO c 122 FI para instala oes lipo A ertas<br />

Verifique 0ventilador<br />

F12 Sobrcorr HW Verifique a programacao Verilique quanta a carga excessiva configurayao indevida do reforeo ce configuracao<br />

da tensao de frenagem CCmuito elevada ou outras causas de corrente excessiva<br />

F13 Faiha alerram Verifique a fiacao externa edo motor 80Sterminais de sarda do inversor quanta a condicao deaterramento<br />

F29 Perda Enl Anlg111 Uma enlrada anal6gica e configurada para acusar a perda de sinal Ocofreu urna perda de sinal<br />

F33 Tent ReinAut Corrija a causa da lalhae remova manualmente<br />

F38 Fase UpTerra Verifiquea fiayao enlre0 inversor e0motor Verifique 0 motor quanto a lase ligada a terra<br />

F39 Fase V pi Terra<br />

Saa falha nao puder sef removida substilua 0 inversor<br />

F40 Fase Wpi Terra<br />

F41 CurtoFase UV Verifiquea fiayao dos lerminais de safda do inversor emotor quanto a condiyao de curto<br />

F42 CurtoFase UW<br />

Sea falha nao puderser removida substitua 0 inversor<br />

F43 CurtoFase VW<br />

F48 Par m delault o inversor recebeu um comando para gravar os valoresdedefault para a EEPROM Remova afalha ou desligue<br />

eligue novamente 0 inversor Programeos parametros do inversor conforme necessario<br />

F63 Sobrcorr SWill Venlique os requisitos de carga ea eonligura ao do A098 Dispare Carr SW<br />

F64 Sobrec Inversor Reduza a carga ou prolongue 0 tempo de acelera o<br />

F70 Unidade pol neia Oesliguee ligue novamenle Sea falha nao puderser removida substitua 0 inversor<br />

F71 Perda Rede Adapl A rede de comunica o falhou<br />

F80 Auto juste A funcao de auto ajuste foi caricelada pelo usuario ou lalhou<br />

F81 Perda de comun<br />

p<br />

s<br />

P d<br />

r Oo v<br />

d<br />

o<br />

Ooi b a<br />

i<br />

ri<br />

foi inteneionalmente desconeelado Desligue usando 0A 10S Aao perda eomunj<br />

Fl00 Checksum par m Restauraros defaults de fabrica<br />

F122 Falha plaea ElS Oesligue e ligue novamente Sea falha nao puder ser removida substitua 0 inversor<br />

1<br />

Falha do tlpo Auto ReseVOpera ao Configurar com os parametros A092 e A093<br />

rt<br />

t f<br />

J ia or


Portugues 18<br />

Dimensoes do inversor<br />

Gabinetes do PowerFlex 40 Classificayoes indicadas em kW e HP<br />

GablnetE 120V CA Monof sleo 240V CA Monof8slco 240V CA Trlf slco 480V CA Trlf8slco 600V CA<br />

Trif slco<br />

B 04 0 1<br />

51 04 0 51 0 4 0 5 2 04 0 5 2 2 0 75 1 0 4 0 5 0<br />

0 75 1 0 0 75 0 0 75 1 01 37 5 0 0 75 1 0 4 0 5 0 1<br />

1 1 1 5 1 5 2 0 1 5 2 0 1 5 2 01 2 2 3 0<br />

c 2 2 3 0 5 5 5<br />

517 517 51 11 0 15 0 5 5 11 0 15 0<br />

7 5 10 0 7 5 10 0 7 5f 5 10 0<br />

rr Ao1<br />

Inversor CA PowerFlex 40<br />

r<br />

J<br />

9 obo<br />

000CJ<br />

j<br />

III<br />

II5 5 0 22<br />

r<br />

0<br />

l<br />

1<br />

213 Ol<br />

f3 Ol<br />

512 Ol<br />

As dimensoes estao indicadas em milfmetros e polegadas<br />

Os pesos estao indicados em quilogramas e ibras<br />

l<br />

c<br />

Peso de<br />

s<br />

A B C D E F remessa<br />

B 100 180 136 87 168 874 2 2<br />

3 941 7 091 5 35 3 43 6 61 344 4 9<br />

C 130 260 180 116 246 4 3<br />

5 1 10 2 7 1 4 57 9 7 9 5<br />

Kits opcionais de comunicayiio IlItro RFI IP 30 NEMA 1UL Tipo 1<br />

m<br />

m m<br />

o m m<br />

D<br />

J<br />

Inversor Inversor<br />

f com com<br />

is Op jjo gablnete B gablnete C<br />

A Tampa de Comun 25 0 981 25 0 981<br />

B Fillro de linhaEMC 50 1 97 60 2 361<br />

C Fillro de IinhaEMC 229 9 02 309 12 17<br />

0 iP30INEMA lUL PO 1 33 1 30 60 2 36<br />

IP30 NEMA lUL Tipo 1 64 2 521 60 2 38<br />

para tamps de comun<br />

o<br />

77 5 3 05<br />

50 0 1 97<br />

22 510 89<br />

Gablnete B 22 JBCB<br />

usado coma tampa de comun<br />

Gablnete C 22 JBAC<br />

Gablnete C 22 JBCC<br />

usado com atampa de comun<br />

u s Allen Bradley Drives Teohnlcal Support<br />

Tel 11262 512 8176 Fex 1 262 512 2222 Email support@drlves ra rockwellcom Online wwwab comlsupportJabdrlves<br />

Rockwell<br />

Publica9ao 22B Q8001 B PT P Janeiro de 2004 Automation<br />

Substltul a publica o de outubro de 2002 Copyrlght@2004 Rockwell Automation Inc TOOos os dire os reservados Impresso no Taiwan


www rockwellautomatlon com<br />

II11I111I1I1111111111111111111<br />

Corporate Headquarters<br />

Rockwell Automation 777 East Wisconsin Avenue Sulto 1400 Milwaukee WI 53202 5302 USA Tel 1 414 212 5200 Fax 1l 414 212 5201<br />

Hoedquarters for Allen Bradley Products Rockwell Software Products and Globel Manufacturing Solutions<br />

Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444<br />

AockwellAutomatlon SA NY Vorsllaan Bculeverd du Souveraln 36 BP 3A<br />

Europe B 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640<br />

Asia Pacific Rockwell Automation 27 FCiticorp Centre 18 Whitfield Road CausewayBay Hong Kong Tel 852 2887 4788 Fax 852 2508 1846<br />

Hoadquarters for and Reliance ElectricProducts<br />

Dodge<br />

Americas Rockwell Automation 6040 Ponders Court Greenvllle SC 29615 4617 USA Tel 1 864 297 4800 Fax 1 864 281 2433<br />

Europe Rockwell Automation BrOhlstraf3e 22 D 74834 Elztat Dallau Germany Tel 49 62619410 Fax 49 6261 1774<br />

AsIa Pacific Rockwell Automalfon 55 Newton Road 11 01 02 Revenue House Singapore 307987 Tal 65 3516723 Fax 65 355 1733<br />

u s Allen Bradloy Drives Technical Support<br />

Tel 1 262 512 8176 Fax 1 262 512 2222 Email supportCdrlves rarockwellcom OnUne wwwab comlsupporVabdrlves<br />

Publication 22B QS001 B MU P February 2004 5011613101 4001<br />

Supersedes December 2002 Copyright@2004 Rockwell Automalion Inc All rights reserved Prinled in Taiwan<br />