Dati in Ingresso<br />
Drive Type AVRy 1 1425 AVRy 1 2545 AVRy 2 3360<br />
Uln AC Input voltage [V] 3 x 400 V -15%, 3 x 460 +15% 3 x 400 V -15%, 3 x 460 +15% 3 x 400 V -15%, 3 x 460 +15%<br />
Fln AC Input frequency [Hz] 50/60 Hz ±5% 50/60 Hz ±5% 50/60 Hz ±5%<br />
cosφL1 ≈+1 (motor), ≈ -1 (generator) better than ± 0.95<br />
Rated input power<br />
(see motor side output load cycle)<br />
Rated input current Iln<br />
THD of Iln<br />
@ Uln= 400Vac<br />
(ref.to IL1 and @ Isc=100)<br />
[kVA] 13 22 29<br />
[Aac]<br />
18 32 42<br />
[%] ≤4 ≤4 ≤4<br />
Efficiency [%] ≥94 ... 96 ≥94 ... 96 ≥94 ... 96<br />
Modulation type Space vector PWM Space vector PWM Space vector PWM<br />
Default modulation frequency [kHz] 16 8 8<br />
Dati in Uscita<br />
input Data • Caractéristiques d’Entrée • Eingangsdaten • Datos de Entrada<br />
Output Data • Caractéristiques de Sortie • Ausgangsdaten • Datos de Salida<br />
Drive Type AVRy 1 1425 AVRy 1 2545 AVRy 2 3360<br />
Output voltage range U2 [V] 0 ... 520 0 ... 520 0 ... 520<br />
Output frequency range f2 [Hz] 0 ... 300 0 ... 300 0 ... 300<br />
Modulation type Space vector PWM Space vector PWM Space vector PWM<br />
Modulation frequency [kHz] 8 8 8<br />
Max. output dV / dt kV / μs 5 5 5<br />
I 2n Rated output current [A] 14 25 33<br />
I OLVD Inverter Output Overload [A] 25 45 60<br />
Ventilazione (Tutti gli inverter sono equipaggiati con ventilatori interni)<br />
Cooling (All inverters are equipped with internal fans) • Ventilation (Tous les variateurs sont équipés de ventilateurs internes)<br />
• Lüftung (Alle Frequenzumrichter sind mit internen Lüftern ausgestattet) • Ventilación (Todos los convertidores<br />
disponen de ventiladores internos)<br />
Drive Type AVRy 1 1425 AVRy 1 2545 AVRy 2 3360<br />
Pv (Heat dissipation) @Uln=400Vac (*) W 480 620 800<br />
Airflow of fan Internal choke fan m 3 /h 140 250 250<br />
Recommended minimum cabinet opening for cooling<br />
<strong>Gefran</strong> Spa - Drive & Motion Control Unit • www.gefran.com<br />
Heatsink fans m 3 /h 3 x 50 3 x 50 3 x 50<br />
Internal choke and heatsink cm 2 408 408 630<br />
sq.inch 63.24 63.24 97.65<br />
(*) Valori riferiti alla frequenza di switching in condizioni di default<br />
(*) Values that refer to operation at default switching frequency.<br />
(*) Valeurs se rapportant au fonctionnement à la fréquence de commutation par défaut.<br />
(*) Die Verluste aufgrund des Wärmeverlustes (Heat dissipation losses) beziehen sich auf die Default-Taktfrequenz.<br />
(*) Las pérdidas debidas a la disipación del calor (Heat dissipation losses) se refieren a lafrecuencia de conmutación por defecto.<br />