SIEIDrive - LIFT - Gefran
SIEIDrive - LIFT - Gefran
SIEIDrive - LIFT - Gefran
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
50<br />
Regen Lift Lift Drive Drive • ADL300 • AVRy<br />
Connessioni standard<br />
Connessioni standard e configurazione<br />
di default del drive.<br />
Drive standard connections and<br />
default configurations<br />
Connexions standards et configuration<br />
par défaut du drive<br />
Standardanschlußbelegung<br />
Conexiones estándar y configuración<br />
por defecto del convertidor<br />
Dimensioni e pesi<br />
Drive type AVRy 1<br />
1425<br />
H mm<br />
(inches)<br />
H1 mm<br />
(inches)<br />
W mm<br />
(inches)<br />
W1 mm<br />
(inches)<br />
D mm<br />
(inches)<br />
Weight<br />
kg (lbs)<br />
Dimensions and Weights<br />
• Dimensions et Poids<br />
• Abmessungen und Gewichte<br />
• Dimensiones y Pesos<br />
670<br />
(26.38)<br />
656<br />
(25.83)<br />
350<br />
(13.78)<br />
300<br />
(11.81)<br />
150.3<br />
(5.92)<br />
28.7<br />
(63.27)<br />
AVRy 1<br />
2545<br />
670<br />
(26.38)<br />
656<br />
(25.83)<br />
350<br />
(13.78)<br />
300<br />
(11.81)<br />
150.3<br />
(5.92)<br />
32.0<br />
(70.55)<br />
AVRy 2<br />
3360<br />
788<br />
(31.02)<br />
753<br />
(29.65)<br />
420<br />
(16.53)<br />
400<br />
(15.75)<br />
180<br />
(7.09)<br />
55.0<br />
(121.25)<br />
<strong>SIEIDrive</strong> • Lift Control System<br />
Program to ( RUN cont mon)<br />
D<br />
MAINS<br />
3 Ph~<br />
X1 X2<br />
Drive<br />
OK<br />
Brake<br />
cont<br />
mon<br />
F1<br />
Start fwd<br />
Start rev<br />
Mlt spd s 0<br />
Mlt spd s 1<br />
Mlt spd s 2<br />
Fault reset<br />
Drive ready<br />
Speed is 0<br />
1 3 5<br />
X3 X4<br />
X1 X2<br />
K1M<br />
2 4 6<br />
12 Dig.Inp. 0 (Inverter Enable)<br />
13 Dig.Inp. 1<br />
14 Dig.Inp. 2<br />
15 Dig.Inp. 3<br />
16 COM DI/0<br />
18 0V24<br />
19 +24 VDC<br />
36 Dig.Inp. 4<br />
37 Dig.Inp. 5<br />
38 Dig.Inp. 6<br />
39 Dig.Inp. 7<br />
41 Dig.Out. 2<br />
42 Dig.Out. 3<br />
46 Supply DO<br />
80<br />
82<br />
83<br />
85<br />
U1/L1<br />
V1/L2<br />
W1/L3<br />
PE1/<br />
During maintenance operation<br />
opening must be delayed<br />
Standard connections • Connexions standards<br />
• Standardanschlußbelegung • Conexiones estándar<br />
AVRy regulation board<br />
112 D ig.Inp. (Regen Enable)<br />
141 Dig.Out. (Regen OK)<br />
Dig. Out. 0<br />
Dig. Out. 1<br />
Power Board<br />
W<br />
W1<br />
L01<br />
83<br />
Brake<br />
cont<br />
mon<br />
XE<br />
11 15<br />
6 10<br />
1 5<br />
U2/T1<br />
V2/T2<br />
W2/T3<br />
PE2/<br />
85<br />
FR<br />
L01<br />
X1 X2<br />
K3M K2M<br />
L02<br />
L02<br />
K2 K3M<br />
H1<br />
X3 X4<br />
H<br />
80<br />
RUN cont mon<br />
82<br />
M<br />
3 Ph~<br />
FR(R)<br />
Brake<br />
E