Lift Drive Introduction<br />
• AGL50<br />
Dati in Ingresso<br />
Sizes - AGL50 2040 2055 2075<br />
Uln • ac Input voltage Vac three-phase network 380 V (-15%) ... 480 V (+10%)<br />
Fln • Input frequency Hz 50 Hz – 2 % ... 60 Hz + 2 %<br />
Overvoltage threshold Vdc 800 Vdc<br />
Undervoltage threshold<br />
In • AC Input current for continuous service<br />
@ 380-400 Vac Vdc 380 Vdc<br />
@ 420-440 Vac Vdc 405 Vdc<br />
@ 460-480 Vac Vdc 415 Vdc<br />
Connection with 3-phase reactor @ 400 Vac A 9 13 16<br />
Connection with 3-phase reactor @ 480 Vac A 8.2 11.7 14.3<br />
Connection without 3-phase reactor @ 400 Vac A 9 13 16<br />
Connection without 3-phase reactor @ 480 Vac A 10 15 20<br />
THD of input current % > 100 % (without choke)<br />
Max short circuit power without line reactor<br />
(Zmin=1%)<br />
kVA 500 650 850<br />
Braking IGBT Unit Standard internal (with external resistor); Braking torque 150%.<br />
No-load consumption (Energy rating):<br />
Stand-by consumption "Fan Off"<br />
<strong>SIEIDrive</strong> • Lift Control System<br />
input Data • Caractéristiques d’Entrée • Eingangsdaten • Datos de Entrada<br />
W 11.6 11.6 11.6