3.4.1.3 Inputs<br />

3.4.1.4 Outputs<br />

Inputs are actuated by +24 VDC signals. The 0 V potential<br />

connects to terminal L2-. Whenever an input signal is sent<br />

to the terminal the LED assigned to that terminal will light<br />

up green.<br />

Power (24 VDC) to the outputs is supplied via terminals<br />

"L2+" and "L2-". Whenever an output signal is sent to the<br />

terminal the LED assigned to that terminal will light up red.<br />

Output current<br />

The current of every output is rated at 0.5 A. Outputs are<br />

put into groups of 4 (0...3 and 4...7) which are actuated by<br />

the same driver module. Every driver module can sustain<br />

a total load of up to 1.9 A (� Technical Data, Outputs).<br />

Overload (short circuit) on an output or an output driver<br />

will switch the output off. The outputs of the basic module<br />

are not monitored for short circuits. A fault occurring in the<br />

outputs of the expansion modules cause Ventura Remote<br />

PLC to set the relevant status flag (�section 5.3.4.4).<br />

Parallel connection of outputs<br />

Since the controller uses a data byte to address the<br />

outputs of the same driver module, it is fairly<br />

unproblematic to connect them in parallel.<br />

The total load of every group of 16 outputs must be no<br />

greater than 8 A. This is the limiting current that supply<br />

terminal L2 is rated at.<br />