Hardware<br />

3.3.2 Wiring<br />

All plug-type terminals accept flexible wires whose<br />

conductor has a diameter of 2.5 mm 2 .<br />

Screwdriver<br />

To fit the wires you need a standard flat-blade screwdriver<br />

with a blade max. 4 mm wide.<br />

To unplug<br />

The connectors fit very tightly to avoid them coming off if<br />

exposed to vibration. In case they won't come off by hand<br />

you can use a lever, e.g. a flat object such as a<br />

screwdriver with a wide blade.<br />

Do not pull the lead to unplug. They might otherwise slip<br />

out of the terminals or rip off.<br />