Software<br />

5.3.7.2 A, B, Ref Up/Down Counter<br />

The A, B, Ref counter is a 32-bit counter that counts the<br />

alternations of pin A and pin B signals. It can discriminate<br />

phases to enable up/down count detection. The counter is<br />

controlled either by the Ref impulse of an encoder or by a<br />

sensor attached to the Ref input.<br />

5.3.7.2.1 A, B, Ref Counter Setup<br />

Run the PLC Configuration Editor to set up the A, B, Ref<br />

counter.<br />

� Choose "Resources, PLC Configuration, <strong>Kuhnke</strong><br />

Ventura Remote IO CAN (or DP), Internal IO,<br />

Counter1 A-BRef".<br />

� Set the options as appropriate.<br />

Run_IRQmod_after_reference_value<br />

(Aufruf_Ubst_bei_ Vergleichswert)<br />

Setting to say whether or not a reference value IRQ<br />

module is to be run when the count equals a reference<br />

value.<br />

The reference value can be 0 or set to any other value in<br />

the user program.<br />

The IRQ module contains your code on how to react to<br />

the interrupt request (IRQ module � section 4.4.9)<br />

Encoder resolution (single / 4_fold)<br />

(Drehgeberauflösung (1_fach / 4_fach)<br />

146 E 700 GB