Software Measuring range Number of digital values Range of values 0..+5 V 1024 0..16#7FE0 0..+10 V 1024 0..16#7FE0 Sample program: The measuring range of channel 3 is set to 10V. ai3 measures +10.0V. 140 E 700 GB
5.3.6 Internal Analogue Output Functions Ventura Remote PLC has: � 2 analogue outputs ao0 and ao1 Software � Analogue outputs send analogue control signals to drives etc. in order to control and actuate them. Analogue outputs are designed as PWM outputs. The voltage is set by the pulse-to-pause ratio plus subsequent smoothing. The resolution is used to set the output frequency and, with it, the range of output voltages: Resolution (Aufloesung) Number of output values Frequency [kHz] Ripple 8 bit 256 62.5 ±5mV 10 bit 1024 15.625 ±10mV � To set up the resolution of every analogue output and to retrieve information about analogue output variables, choose "Resources, PLC Configuration, Kuhnke Ventura Remote IO CAN (or DP), Internal IO, AO 2". Analogue output: resolution � Disable unused analogue outputs via the PLC Configuration Editor. 141
- Page 89 and 90: 4.4.10 Setting up the Watchdog Func
- Page 91 and 92: 4.5 Library MMC.LIB Function Librar
- Page 93 and 94: 4.5.2 Registering with the File Sys
- Page 95 and 96: 4.5.4 Copying Files Function Librar
- Page 97 and 98: 4.5.6 Determining the Free MMC Spac
- Page 99 and 100: 4.5.8 Moving a File Function Librar
- Page 101 and 102: 4.5.9 Opening a File Function Libra
- Page 103 and 104: 4.5.10 Reading from a File Function
- Page 105 and 106: 4.5.12 Setting the Edit Bookmark of
- Page 107 and 108: 4.5.14 Initialising the File System
- Page 109 and 110: Function Libraries FUNCTION_BLOCK M
- Page 111 and 112: � Use 'start' to repeatedly run t
- Page 113 and 114: 4.6.4 Online Reset (cold) 4.6.5 Res
- Page 115 and 116: 4.7.2 Variables with Set Addresses
- Page 117 and 118: 4.8 Extraremanent Data 4.8.1 Remane
- Page 119 and 120: Remanent Data If an extraremanent m
- Page 121 and 122: TYPE Extrarema_02: STRUCT END_STRUC
- Page 123 and 124: Start_OK := CheckXREMDATA(Clear); I
- Page 125 and 126: 5 Software Software Read this secti
- Page 127 and 128: Internal combi I/Os %IX0.0-%IX0.3 a
- Page 129 and 130: Internal I/Os AI_x and AO_x I/O Var
- Page 131 and 132: Software If an "Input IRQ module" h
- Page 133 and 134: 5.3.3 Functions of Internal Outputs
- Page 135 and 136: Software Value Frequency Value Freq
- Page 137 and 138: 5.3.4 Short-circuited Output Softwa
- Page 139: 5.3.5 Internal Analogue Input Funct
- Page 143 and 144: 5.3.7 Functions of Internal Counter
- Page 145 and 146: 5.3.7.1.2 Event Counter Variables V
- Page 147 and 148: Resolution of the rotary encoder: s
- Page 149 and 150: Software 5.4 Functions of the Basic
- Page 151 and 152: 5.7 Status Messages of Expansion Mo
- Page 153 and 154: 6 PROFIBUS-DP 6.1 Basic Information
- Page 155 and 156: 6.2 Master-Slave Communication PROF
- Page 157 and 158: 6.2.2 Receive Parameter Data (Prm_D
- Page 159 and 160: 6.2.2.2 Device-specific Bus Paramet
- Page 161 and 162: PROFIBUS replaces the term "byte" w
- Page 163 and 164: Octet 4: Diag.Master_Add PROFIBUS A
- Page 165 and 166: 6.2.4 Master-Slave Data Communicati
- Page 167 and 168: Example: VAR bIn_0: BYTE; bOut_0: B
- Page 169 and 170: 7 CANopen CANopen At this point, we
- Page 171 and 172: 7.1.1 CANopen Example CANopen A Ven
- Page 173 and 174: • Step3: Write and test CoDeSys p
- Page 175 and 176: PROGRAM PLC_PRG VAR CANMaster_Ok: B
- Page 177 and 178: 8 PLC Error Handling 8.1 "Failure"
- Page 179 and 180: Example VAR C690_Error: BYTE; END_V
- Page 181 and 182: 8.3.1 Short-circuited Output (Error
- Page 183 and 184: => - STOP: The program is stopped E
- Page 185 and 186: 9 Appendix 9.1 Technical Data 9.1.1
- Page 187 and 188: Appendix Max. current .............
- Page 189 and 190: 9.1.3 Communication Ports V.24 port
Software<br />
Measuring<br />
range<br />
Number of<br />
digital values<br />
Range of<br />
values<br />
0..+5 V 1024 0..16#7FE0<br />
0..+10 V 1024 0..16#7FE0<br />
Sample program:<br />
The measuring range of channel 3 is set to 10V.<br />
ai3 measures +10.0V.<br />
140 E 700 GB