<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

For highly flexible applications:<br />

� LAPP KABEL ÖLFLEX-SERVO-FD 755 CP; 4 G 6 + (2 x 0.75 StD) + (2 x 1.0 StD) CP;<br />

∅ 18.9 mm,<br />

with tinned CU shielding<br />

for highly flexible use in drag chains<br />

8.6.10 Connection notes concerning [X6] and [X6A]<br />

Motor connector<br />

Motor phase U or 1<br />

Motor phase V or 2<br />

Motor phase W or 3<br />

PE (motor)<br />

MT+<br />

MT-<br />

PE (option)<br />

BR+<br />

BR-<br />

Connector housing<br />

Motor housing<br />

Figure 22: Pin assignment [X6] and [X6A]: Motor<br />

• Connect the inner shields to PIN 3. Maximum length: 40 mm.<br />

� Maximum length of unshielded cores: 35 mm.<br />

� Connect the shield on the controller side flat to shield terminal SK14.<br />

PHOENIX POWER COMBICON<br />

at X6<br />

Connection of the<br />

outer shield of the<br />

motor cable<br />

88 E 732 GB<br />

14.12.2006<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

PHOENIX MINI<br />

COMBICON at X6A<br />

� Connect the shield on the motor side flat to the connector or motor housing. Maximum length: 40<br />