KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />
8.3 Connection at the <strong>ARS</strong> <strong>2320</strong> servo positioning<br />
controller: Power supply and braking resistor [X9]<br />
The <strong>ARS</strong> <strong>2320</strong> servo positioning controller is supplied with three-phase mains power through<br />
connector [X9]. As an alternative to AC power supply or as a DC-link, direct DC power supply for the<br />
DC-link is possible via connector [X9].<br />
The <strong>ARS</strong> <strong>2320</strong> servo positioning controller receives its 24VDC power supply for the<br />
electronic control system through connector [X3].<br />
8.3.1 Configuration at the <strong>ARS</strong> <strong>2320</strong> servo positioning controller [X9]<br />
� PHOENIX Phoenix Power-Combicon, 11-pin type, PC 4/11-G-7.62<br />
8.3.2 Mating connector [X9] at the <strong>ARS</strong> <strong>2320</strong><br />
� PHOENIX Phoenix Power-Combicon, 11-pin type, PC 4 HV/11-STF-7.62<br />
8.3.3 Pin assignment [X9] at the <strong>ARS</strong> <strong>2320</strong><br />
Table 27: Pin assignment [X9] at the <strong>ARS</strong> <strong>2320</strong>: Supply<br />
Pin no. Name Value Specification<br />
1 L1 3 x 230 VAC -10% Mains supply phase L1<br />
2 L2 to<br />
Mains supply phase L2<br />
3 L3<br />
3 x 480 VAC +10% Mains supply phase L2<br />
4 PE - Connection of mains ground conductor<br />
5<br />
6<br />
7<br />
8<br />
ZK+ < 700 VDC Alternative supply: Positive DC-link voltage<br />
ZK- < 700 VDC Alternative supply: Negative DC-link voltage<br />
E 732 GB 79<br />