<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

L1<br />

L2<br />

L3<br />

230 VAC -10% ...<br />

480 VAC +10%<br />

PE<br />

+24VDC<br />

Permanently excited<br />

synchronous machine<br />

T<br />

0V<br />

24 V /2 A max.<br />

for the holding<br />

brake<br />

Alternative !<br />

SM<br />

E<br />

F1<br />

Angle encoder<br />

main fuse<br />

External braking<br />

resistor<br />

Bridge for internal<br />

braking resistor<br />

24V supply<br />

<strong>ARS</strong> <strong>2340</strong><br />

76 E 732 GB<br />

14.12.2006<br />

L1<br />

L2<br />

L3<br />

PE<br />

ZK+<br />

ZK+<br />

ZK-<br />

ZK-<br />

24V+<br />

24V-<br />

U<br />

V<br />

W<br />

MT+<br />

MT-<br />

BR+<br />

BR-<br />

X9<br />

X9A<br />

BR-EXT<br />

BR-CH<br />

BR-INT<br />

X3<br />

Connection of the outer shield<br />

of the motor cable<br />

PE<br />

PE<br />

PE<br />

X6<br />

X6A<br />

X2A / X2B<br />

Resolver / Encoder<br />

Figure 16: Servo positioning controller <strong>ARS</strong> <strong>2340</strong>: Connection to the supply voltage and to<br />

the motor<br />

Operation of the <strong>ARS</strong> 2300 servo positioning controller requires a 24V voltage source for supplying<br />

the electronic system. This voltage source has to be connected to terminals +24V and GND24V.<br />

The power output stage is connected either to terminals L1, L2 and L3 for AC supply or to terminals<br />

ZK+ and ZK- for DC supply.<br />

The motor is connected to terminals U, V, W. The motor temperature switch (PTC or normally closed<br />

contact) is connected to terminals MT+ and MT-, if the switch is integrated in one cable together with