KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />
8 Electrical installation<br />
8.1 Connector configuration<br />
The <strong>ARS</strong> 2300 servo positioning controller is connected to the supply voltage, the motor, the external<br />
braking resistor and the holding brake as shown in Figure 15 and Figure 14.<br />
230 VAC -10% ...<br />
480 VAC +10%<br />
L1<br />
L2<br />
L3<br />
PE<br />
+24VDC<br />
T<br />
0V<br />
Permanently excited<br />
synchronous machine<br />
24 V /2 A max.<br />
for the holding<br />
brake<br />
Alternative !<br />
SM<br />
E<br />
F1<br />
Angle encoder<br />
main fuse<br />
External braking<br />
resistor<br />
Bridge for internal<br />
braking resistor<br />
24V supply<br />
<strong>ARS</strong> <strong>2320</strong><br />
E 732 GB 75<br />
14.12.2006<br />
L1<br />
L2<br />
L3<br />
PE<br />
ZK+<br />
ZK+<br />
ZK-<br />
ZK-<br />
BR-EXT<br />
BR-CH<br />
BR-INT<br />
24V+<br />
24V-<br />
U<br />
V<br />
W<br />
MT+<br />
MT-<br />
BR+<br />
BR-<br />
X9<br />
X3<br />
Connection of the outer shield<br />
of the motor cable<br />
PE<br />
PE<br />
PE<br />
X6<br />
X6A<br />
X2A / X2B<br />
Resolver / Encoder<br />
Figure 15: Servo positioning controller <strong>ARS</strong> <strong>2320</strong>: Connection to the supply voltage and to<br />
the motor