KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />

4.3 Motor connection [X6]<br />

Table 12: Technical data: Motor connection data [X6]<br />

Type <strong>ARS</strong> <strong>2320</strong> <strong>ARS</strong> <strong>2340</strong><br />

Data for use at 3x 400 VAC [± 10%], 50 Hz, with an output stage clock frequency of 5 kHz<br />

Output power 12 kVA 20 kVA<br />

Max. output power for 2 s 25 kVA 50 kVA<br />

Output current 20 Aeff 40 Aeff<br />

Max. output current for 2 s 41.5 Aeff 70 Aeff<br />

Clock frequency 12.5 kHz max.<br />

Max. mains current in continuous<br />

operation 1)<br />

1) for a cos ϕ of 0.7 in the motor circuit<br />

4.3.1 Current derating<br />

19 Aeff<br />

32 Aeff<br />

Other than stated in the technical motor data, the <strong>ARS</strong> <strong>2320</strong> and <strong>ARS</strong> <strong>2340</strong> servo positioning<br />

controllers have current derating in nominal operating conditions.<br />

The following formula can be used to calculate the output current of the output stage as a function of<br />

the output stage frequency for values > 5 kHz:<br />

<strong>ARS</strong> <strong>2320</strong>:<br />

I(f PWM ) =<br />

<strong>ARS</strong> <strong>2340</strong>: I(f PWM ) =<br />

5<br />

4<br />

5<br />

2<br />

A<br />

kHZ<br />

A<br />

kHZ<br />

f PWM<br />

f PWM<br />

26,25 A<br />

52,50 A<br />

E 732 GB 35<br />