Fuxx Control ARS 2320 / ARS 2340 KUHNKE Automation 11.4 General installation notes for technology modules DANGER ! Prior to installing technology modules, the ARS 2300 servo positioning controller has to be disconnected from any current-carrying conductors. After the operating voltage has been disconnected, wait for 5 minutes so that the capacities in the ARS 2300 servo positioning controller can be completely discharged. Make sure that ESD protection measures are taken when handling technology modules. Remove the front plate above the technology slot of the ARS 2300 servo positioning controller using a suitable screwdriver. Then push the technology module into the open technology slot such that the circuit board is held by the lateral guides of the technology slot. Push the technology module in until it reaches the stop. Then screw technology module onto the housing of the servo positioning controller using the Phillips screw. Make sure that the front plate has conducting contact with the housing of the servo positioning controller (PE). 146 E 732 GB 14.12.2006

<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

11.4 General installation notes for technology modules<br />

DANGER !<br />

Prior to installing technology modules, the <strong>ARS</strong> 2300 servo positioning controller has to<br />

be disconnected from any current-carrying conductors. After the operating voltage has<br />

been disconnected, wait for 5 minutes so that the capacities in the <strong>ARS</strong> 2300 servo<br />

positioning controller can be completely discharged.<br />

Make sure that ESD protection measures are taken when handling technology modules.<br />

Remove the front plate above the technology slot of the <strong>ARS</strong> 2300 servo positioning controller using a<br />

suitable screwdriver. Then push the technology module into the open technology slot such that the<br />

circuit board is held by the lateral guides of the technology slot. Push the technology module in until it<br />

reaches the stop. Then screw technology module onto the housing of the servo positioning controller<br />

using the Phillips screw. Make sure that the front plate has conducting contact with the housing of the<br />

servo positioning controller (PE).<br />