KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />

Figure 37: Position of the pin-and-socket connectors [X21] and [X22] at the front plate<br />

11.3.4 Mating connector<br />

� Connector [X21] for 8 digital inputs: PHOENIX MicroCombicon FK-MC 0.5/9-ST-2.5<br />

� Connector [X22] for 8 digital outputs: PHOENIX MicroCombicon FK-MC 0.5/10-ST-2.5<br />

11.3.5 Connection notes<br />

The MicroCombicon mating connectors made by PHOENIX regarding [X21] (FK-MC 0.5/9-ST-2.5)<br />

and [X22] (FK-MC 0.5/10-ST-2.5) are supplied together with the EA88 interface technology module.<br />

The cables are connected in the form of crimp connections. To do so, strip the cable at a length of<br />

about 8 mm. Then insert it into the desired opening by pressing down the orange crimp lock using a<br />

suitable screwdriver, the tip of a ball-pen or something similar. Release the lock to fix the cable in<br />

place. The maximum admissible wire cross-section (wire gauge) is 0.5 mm 2 or AWG20.<br />

If the EA88 interface is also used to control digital outputs, an additional external 24V supply voltage<br />

has to be connected to [X22], pin 10.<br />

As the lines GND24V and +24Vext. have to transfer the entire current of all outputs connected, their<br />

cross-section has to be sized accordingly (recommended: AWG 20).<br />

E 732 GB 145<br />