Fuxx Control ARS 2320 / ARS 2340 KUHNKE Automation 11.3.3 Pin assignment and cable specifications 11.3.3.1 Power supply � The admissible input voltage range during operation is 15VDC….32VDC. � The digital outputs of the EA88 technology module are supplied with voltage exclusively by an external 24VDC power supply. The nominal input voltage for the I/O supply is 24VDC. If digital inputs are used, the reference potential GND24V of the 24VDC supply also has to be connected to the EA88 interface technology module 11.3.3.2 Pin assignments The following elements can be found on the front plate of the EA88 interface: � Connector [X21] for 8 digital inputs: PHOENIX MicroCombicon MC 0.5/9-G-2.5 (9-pin type) Table 53: EA88: Connector [X21] for 8 digital inputs Pin 1 2 3 4 5 6 7 8 9 Signal GND 24V In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 � Connector [X22] for 8 digital outputs: PHOENIX MicroCombicon MC 0.5/10-G-2.5 (10-pin type) Table 54: EA88: Connector [X22] for 8 digital outputs Pin 1 2 3 4 5 6 7 8 9 10 Signal GND 24V Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 +24VDC external The following Figure 37 shows the position of the connectors and their numbering: 144 E 732 GB 14.12.2006
KUHNKE Automation Fuxx Control ARS 2320 / ARS 2340 Figure 37: Position of the pin-and-socket connectors [X21] and [X22] at the front plate 11.3.4 Mating connector � Connector [X21] for 8 digital inputs: PHOENIX MicroCombicon FK-MC 0.5/9-ST-2.5 � Connector [X22] for 8 digital outputs: PHOENIX MicroCombicon FK-MC 0.5/10-ST-2.5 11.3.5 Connection notes The MicroCombicon mating connectors made by PHOENIX regarding [X21] (FK-MC 0.5/9-ST-2.5) and [X22] (FK-MC 0.5/10-ST-2.5) are supplied together with the EA88 interface technology module. The cables are connected in the form of crimp connections. To do so, strip the cable at a length of about 8 mm. Then insert it into the desired opening by pressing down the orange crimp lock using a suitable screwdriver, the tip of a ball-pen or something similar. Release the lock to fix the cable in place. The maximum admissible wire cross-section (wire gauge) is 0.5 mm 2 or AWG20. If the EA88 interface is also used to control digital outputs, an additional external 24V supply voltage has to be connected to [X22], pin 10. As the lines GND24V and +24Vext. have to transfer the entire current of all outputs connected, their cross-section has to be sized accordingly (recommended: AWG 20). E 732 GB 145 14.12.2006
- Page 93 and 94: KUHNKE Automation Fuxx Control ARS
- Page 95 and 96: KUHNKE Automation Fuxx Control ARS
- Page 97 and 98: KUHNKE Automation Fuxx Control ARS
- Page 99 and 100: KUHNKE Automation Fuxx Control ARS
- Page 101 and 102: KUHNKE Automation Fuxx Control ARS
- Page 103 and 104: KUHNKE Automation Fuxx Control ARS
- Page 105 and 106: KUHNKE Automation Fuxx Control ARS
- Page 107 and 108: KUHNKE Automation Fuxx Control ARS
- Page 109 and 110: KUHNKE Automation Fuxx Control ARS
- Page 111 and 112: KUHNKE Automation Fuxx Control ARS
- Page 113 and 114: KUHNKE Automation Fuxx Control ARS
- Page 115 and 116: KUHNKE Automation Fuxx Control ARS
- Page 117 and 118: KUHNKE Automation Fuxx Control ARS
- Page 119 and 120: KUHNKE Automation Fuxx Control ARS
- Page 121 and 122: KUHNKE Automation Fuxx Control ARS
- Page 123 and 124: KUHNKE Automation Fuxx Control ARS
- Page 125 and 126: KUHNKE Automation Fuxx Control ARS
- Page 127 and 128: KUHNKE Automation Fuxx Control ARS
- Page 129 and 130: KUHNKE Automation Fuxx Control ARS
- Page 131 and 132: KUHNKE Automation Fuxx Control ARS
- Page 133 and 134: KUHNKE Automation Fuxx Control ARS
- Page 135 and 136: KUHNKE Automation Fuxx Control ARS
- Page 137 and 138: KUHNKE Automation Fuxx Control ARS
- Page 139 and 140: KUHNKE Automation Fuxx Control ARS
- Page 141 and 142: KUHNKE Automation Fuxx Control ARS
- Page 143: KUHNKE Automation Fuxx Control ARS
<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />
11.3.3 Pin assignment and cable specifications<br />
11.3.3.1 Power supply<br />
� The admissible input voltage range during operation is 15VDC….32VDC.<br />
� The digital outputs of the EA88 technology module are supplied with voltage exclusively by an<br />
external 24VDC power supply. The nominal input voltage for the I/O supply is 24VDC.<br />
If digital inputs are used, the reference potential GND24V of the 24VDC supply also has to be<br />
connected to the EA88 interface technology module<br />
11.3.3.2 Pin assignments<br />
The following elements can be found on the front plate of the EA88 interface:<br />
� Connector [X21] for 8 digital inputs: PHOENIX MicroCombicon MC 0.5/9-G-2.5 (9-pin type)<br />
Table 53: EA88: Connector [X21] for 8 digital inputs<br />
Pin 1 2 3 4 5 6 7 8 9<br />
Signal GND<br />
24V<br />
In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8<br />
� Connector [X22] for 8 digital outputs: PHOENIX MicroCombicon MC 0.5/10-G-2.5 (10-pin type)<br />
Table 54: EA88: Connector [X22] for 8 digital outputs<br />
Pin 1 2 3 4 5 6 7 8 9 10<br />
Signal GND<br />
24V<br />
Out 1 Out 2 Out 3 Out 4 Out 5 Out 6 Out 7 Out 8 +24VDC<br />
external<br />
The following Figure 37 shows the position of the connectors and their numbering:<br />
144 E 732 GB<br />
14.12.2006