<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

11.1.3 Pin assignments and cable specifications<br />

11.1.3.1 Pin assignments<br />

� 9-pin DSUB connector, female<br />

Table 48: Pin assignment: PROFIBUS-DP interface<br />

Pin no. Name Value Specification<br />

1 Shield - Cable shield<br />

6 +5V +5 V +5V output 1)<br />

2 - - Not used<br />

7 - - Not used<br />

3 RxD / TxD-P B-line transmission / reception data<br />

8 RxD / TxD-N A-line transmission / reception data<br />

4 RTS / LWL Request to Send 2)<br />

9 - - Not used<br />

5 GND5V 0 V Reference potential GND 5V 1)<br />

1) Can be used for external bus termination or to supply the transmitter/receiver of an optical<br />

waveguide transmission.<br />

2) The signal is optional. It is used to identify the direction of an optical waveguide connection.<br />

11.1.3.2 Mating connector<br />

� 9-pin DSUB connector, e.g. Erbic MAX Profibus IDC Switch, made by ERNI<br />

11.1.3.3 Cable type and configuration<br />

The cable names given refer to cables made by Lapp. They have proven to be reliable and are<br />

successfully used in many applications. However, it is also possible to use comparable cables from<br />

other manufacturers, e.g. Lütze or Helukabel.<br />

� LAPP KABEL UNITRONIC BUS L2/FIP FC; 1 x 2 x 0.64; ∅ 7.8 mm,<br />

with tinned CU shielding<br />

for quick-connect applications with IDC connectors<br />

138 E 732 GB<br />

14.12.2006