17.02.2013 Views

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

Error message<br />

Main index Subindex<br />

14<br />

15<br />

16<br />

Error message explanation Measures<br />

0 Insufficient supply for<br />

identification<br />

1 Current controller identification:<br />

Insufficient measuring cycle<br />

The available intermediate circuit voltage is too<br />

low for the measurement.<br />

The automatic parameter identification process<br />

delivers a time constant beyond the<br />

parameterization value range. The parameters<br />

must be optimized manually.<br />

2 Output stage could not be enabled The power stage has not been enabled.<br />

Check the connection of DIN4.<br />

3 Output stage has been switched off<br />

prematurely<br />

4 Identification does not support the<br />

encoder type set<br />

The power stage has been disabled while the<br />

identification process was running.<br />

The identification cannot be performed with the<br />

present angle encoder settings.<br />

Check the configuration of the angle encoder.<br />

If necessary, contact the technical support<br />

team.<br />

5 Reset pulse could not be found The index pulse could not be found after the<br />

maximum number of electrical rotations.<br />

Check the index pulse signal.<br />

6 Hall signals invalid The pulse sequence or the segmentation of the<br />

Hall signals is unsuitable.<br />

Check the connection. If necessary, contact the<br />

technical support team.<br />

7 Identification impossible Ensure a sufficient intermediate circuit voltage.<br />

Rotor blocked?<br />

8 Invalid number of pairs of poles The number of pairs of poles calculated is<br />

beyond the parameterization range. Check the<br />

motor data sheet. If necessary, contact the<br />

technical support team.<br />

0 Division by 0<br />

1 Range exceeded<br />

0 Error during program execution<br />

1 Illegal interrupt<br />

2 Initialisation error<br />

3 Unexpected state<br />

Please contact the technical support team.<br />

Please contact the technical support team.<br />

130 E 732 GB<br />