<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />
Error message<br />
Main index Subindex<br />
14<br />
15<br />
16<br />
Error message explanation Measures<br />
0 Insufficient supply for<br />
identification<br />
1 Current controller identification:<br />
Insufficient measuring cycle<br />
The available intermediate circuit voltage is too<br />
low for the measurement.<br />
The automatic parameter identification process<br />
delivers a time constant beyond the<br />
parameterization value range. The parameters<br />
must be optimized manually.<br />
2 Output stage could not be enabled The power stage has not been enabled.<br />
Check the connection of DIN4.<br />
3 Output stage has been switched off<br />
prematurely<br />
4 Identification does not support the<br />
encoder type set<br />
The power stage has been disabled while the<br />
identification process was running.<br />
The identification cannot be performed with the<br />
present angle encoder settings.<br />
Check the configuration of the angle encoder.<br />
If necessary, contact the technical support<br />
team.<br />
5 Reset pulse could not be found The index pulse could not be found after the<br />
maximum number of electrical rotations.<br />
Check the index pulse signal.<br />
6 Hall signals invalid The pulse sequence or the segmentation of the<br />
Hall signals is unsuitable.<br />
Check the connection. If necessary, contact the<br />
technical support team.<br />
7 Identification impossible Ensure a sufficient intermediate circuit voltage.<br />
Rotor blocked?<br />
8 Invalid number of pairs of poles The number of pairs of poles calculated is<br />
beyond the parameterization range. Check the<br />
motor data sheet. If necessary, contact the<br />
technical support team.<br />
0 Division by 0<br />
1 Range exceeded<br />
0 Error during program execution<br />
1 Illegal interrupt<br />
2 Initialisation error<br />
3 Unexpected state<br />
Please contact the technical support team.<br />
Please contact the technical support team.<br />
130 E 732 GB<br />
14.12.2006