Error message<br />

Main index Subindex<br />

08<br />

09<br />

Error message explanation Measures<br />

0 Resolver angle encoder error<br />

2 Incremental encoder Z0 trace<br />

signals error<br />

3 Incremental encoder Z1 trace<br />

signals error<br />

4 Digital incremental encoder trace<br />

signals error<br />

5 Incremental encoder Hall generator<br />

signals error<br />

7 Incorrect signal amplitude of<br />

incremental tracks<br />

8 Internal angle encoder error<br />

9 Angle encoder at X2B not<br />

supported<br />

0 Outdated angle encoder parameter<br />

set (type <strong>ARS</strong>)<br />

1 Angle encoder parameter set<br />

cannot be decoded<br />

2 Unknown version of angle encoder<br />

parameter set<br />

3 Defective data structure of angle<br />

encoder parameter set<br />

7 Write-protected angle encoder<br />

EEPROM<br />

9 Angle encoder EEPROM not<br />

sufficient<br />

Angle encoder connected?<br />

Angle encoder cable defective?<br />

Angle encoder defective?<br />

Check the configuration of the angle encoder<br />

interface.<br />

The encoder signals are disturbed: Check the<br />

installation for compliance with EMC<br />

recommendations.<br />

Contact the technical support team.<br />

The data in the angle encoder will be converted<br />

as far as possible. To avoid this message save<br />

the data to the EEPROM of the angle encoder<br />

(reformatting)<br />

Angle encoder defective?<br />

Check the configuration of the angle encoder<br />

interface.<br />

The encoder signals are disturbed: Check the<br />

installation for compliance with EMC<br />

recommendations.<br />

Conversion impossible. Save the data again in<br />

the angle encoder.<br />

Redetermine the data if necessary and save<br />

them again in the angle encoder.<br />

Please contact the technical support team.<br />

Please contact the technical support team.<br />

10 0 Overspeed (spinning protection) Check the parameterization of the limit value.<br />