Error messages<br />
Mainindex<br />
26<br />
Subindex<br />
Meaning of error message Measures<br />
2 HW revision not supported the servo positioning controller to the sales representative.<br />
3 Device function restricted Contact the Technical Support and - if necessary - send<br />
the servo positioning controller to the sales representative.<br />
0 No user parameter set Load the default parameter set.<br />
If the error continues, contact the Technical Support.<br />
1 Checksum error<br />
2 Flash:<br />
Error during write-operation<br />
3 Flash:<br />
Error during erase-operation<br />
4 Flash: Error in internal flash<br />
5 No calibration data<br />
Please contact the Technical Support.<br />
The error cannot be eliminated by the user.<br />
Please contact the technical support team.<br />
6 Missing user position data sets Simply perform save & reset.<br />
Load the default parameter set.<br />
If the error continues to occur, contact the Technical<br />
Support.<br />
7 Faulty data tables (CAM) Load default parameter set, reload the parameter set if<br />
necessary.<br />
If the error continues, contact the Technical Support.<br />
27 0 Following error warning level Check the parameterisation of the following error.<br />
Motor blocked?<br />
28<br />
0 Hours-run meter missing<br />
1 Hours-run meter: write error<br />
2 Hours-run meter correced<br />
3 Hours-run meter converted<br />
Please contact the Technical Support.<br />
Acknowledge the error. If the error continues to occur,<br />
contact the Technical Support.<br />
30 0 Internal calculation error Please contact the Technical Support.<br />
31<br />
0 I²t motor Motor blocked?<br />
1 I²t servo controller Check the power rating of the drive package.<br />
2 I²t-PFC Check the power rating of the drive package.<br />
Select operation without PFC?<br />
3 I²t-Break resistor Braking resistor overloaded. Use external braking resistor?<br />
32 0 Loading period DC-bus exceeded Please contact the Technical Support.<br />
124 E 732 GB<br />