17.02.2013 Views

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

Error messages<br />

Mainindex<br />

26<br />

Subindex<br />

Meaning of error message Measures<br />

2 HW revision not supported the servo positioning controller to the sales representative.<br />

3 Device function restricted Contact the Technical Support and - if necessary - send<br />

the servo positioning controller to the sales representative.<br />

0 No user parameter set Load the default parameter set.<br />

If the error continues, contact the Technical Support.<br />

1 Checksum error<br />

2 Flash:<br />

Error during write-operation<br />

3 Flash:<br />

Error during erase-operation<br />

4 Flash: Error in internal flash<br />

5 No calibration data<br />

Please contact the Technical Support.<br />

The error cannot be eliminated by the user.<br />

Please contact the technical support team.<br />

6 Missing user position data sets Simply perform save & reset.<br />

Load the default parameter set.<br />

If the error continues to occur, contact the Technical<br />

Support.<br />

7 Faulty data tables (CAM) Load default parameter set, reload the parameter set if<br />

necessary.<br />

If the error continues, contact the Technical Support.<br />

27 0 Following error warning level Check the parameterisation of the following error.<br />

Motor blocked?<br />

28<br />

0 Hours-run meter missing<br />

1 Hours-run meter: write error<br />

2 Hours-run meter correced<br />

3 Hours-run meter converted<br />

Please contact the Technical Support.<br />

Acknowledge the error. If the error continues to occur,<br />

contact the Technical Support.<br />

30 0 Internal calculation error Please contact the Technical Support.<br />

31<br />

0 I²t motor Motor blocked?<br />

1 I²t servo controller Check the power rating of the drive package.<br />

2 I²t-PFC Check the power rating of the drive package.<br />

Select operation without PFC?<br />

3 I²t-Break resistor Braking resistor overloaded. Use external braking resistor?<br />

32 0 Loading period DC-bus exceeded Please contact the Technical Support.<br />

124 E 732 GB<br />

14.12.2006