17.02.2013 Views

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

Fuxx Control - ARS 2320 / ARS 2340 Instruction Manual - Kuhnke

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />

10.3 Error / warning messages<br />

If an error occurs, the servo positioning controller <strong>ARS</strong> 2000 will cyclically show an error message in<br />

its seven-segment display. The error message is comprised of an E (for Error), a main index and a<br />

sub index, e.g.: E 0 1 0.<br />

Warnings have the same code numbers as error messages. As a distinguishing feature, warnings<br />

have centre bar before and after the number, e.g. - 1 7 0 -.<br />

The following Table 45: Error messages summarizes the meaning and corresponding measures. A<br />

subindex “*” means that there are a number of errors which are explained in further documentation.<br />

The error messages with the main index 00 do not reflect run time errors. They contain information<br />

and in general there are no measures required by the user. They occur in the error buffer only but will<br />

not be shown on the 7-segment display.<br />

Table 45: Error messages<br />

Error messages<br />

Mainindex<br />

00<br />

Subindex<br />

Meaning of error message Measures<br />

0 Invalid error Information: An invalid (corrupted) entry in the error buffer<br />

is marked by this error number.<br />

1 Invalid error detected and<br />

corrected<br />

No measures required.<br />

Information: An invalid (corrupted) error entry is detected<br />

and corrected. The Debug information stores the initially<br />

found error number.<br />

No measures required.<br />

2 Error cleared Information: The active errors have been cleared<br />

4 Serial number / device type<br />

changed (change of modules)<br />

No measures required.<br />

Information: A flexible error buffer (service module) has<br />

been plugged into another device<br />

No measures required.<br />

01 0 Stack overflow Incorrect firmware?<br />

If necessary, reload the standard firmware again.<br />

Contact the Technical Support<br />

02 0 Undervoltage of DC-bus Error reaction set to “disable drive”?<br />

Check (measure) the intermediate circuit voltage<br />

03<br />

0 Overtemperature analogue motor<br />

1 Overtemperature digital motor<br />

Motor too hot? Check the parameterization<br />

(current controller, current limitation).<br />

Suitable sensor?<br />

Sensor defective?<br />

Error also occurs if sensor is bypassed: device defective.<br />

E 732 GB 119<br />

14.12.2006