KUHNKE Automation <strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong><br />
10.3 Error / warning messages<br />
If an error occurs, the servo positioning controller <strong>ARS</strong> 2000 will cyclically show an error message in<br />
its seven-segment display. The error message is comprised of an E (for Error), a main index and a<br />
sub index, e.g.: E 0 1 0.<br />
Warnings have the same code numbers as error messages. As a distinguishing feature, warnings<br />
have centre bar before and after the number, e.g. - 1 7 0 -.<br />
The following Table 45: Error messages summarizes the meaning and corresponding measures. A<br />
subindex “*” means that there are a number of errors which are explained in further documentation.<br />
The error messages with the main index 00 do not reflect run time errors. They contain information<br />
and in general there are no measures required by the user. They occur in the error buffer only but will<br />
not be shown on the 7-segment display.<br />
Table 45: Error messages<br />
Error messages<br />
Mainindex<br />
00<br />
Subindex<br />
Meaning of error message Measures<br />
0 Invalid error Information: An invalid (corrupted) entry in the error buffer<br />
is marked by this error number.<br />
1 Invalid error detected and<br />
corrected<br />
No measures required.<br />
Information: An invalid (corrupted) error entry is detected<br />
and corrected. The Debug information stores the initially<br />
found error number.<br />
No measures required.<br />
2 Error cleared Information: The active errors have been cleared<br />
4 Serial number / device type<br />
changed (change of modules)<br />
No measures required.<br />
Information: A flexible error buffer (service module) has<br />
been plugged into another device<br />
No measures required.<br />
01 0 Stack overflow Incorrect firmware?<br />
If necessary, reload the standard firmware again.<br />
Contact the Technical Support<br />
02 0 Undervoltage of DC-bus Error reaction set to “disable drive”?<br />
Check (measure) the intermediate circuit voltage<br />
03<br />
0 Overtemperature analogue motor<br />
1 Overtemperature digital motor<br />
Motor too hot? Check the parameterization<br />
(current controller, current limitation).<br />
Suitable sensor?<br />
Sensor defective?<br />
Error also occurs if sensor is bypassed: device defective.<br />