<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

8.13.3 Pin assignment [X5]<br />

Table 42: Pin assignment RS232 interface [X5]<br />

Pin no. Name Value Specification<br />

1 - - Not used<br />

6 - - Not used<br />

2 RxD 10 V / RI > 2kΩ Reception line, RS232 specification<br />

7 - - Not used<br />

3 TxD 10 V / RA < 2kΩ Transmission line, RS232 specification<br />

8 - - Not used<br />

4 +RS485 - reserved for optional RS485 use<br />

9 -RS485 - reserved for optional RS485 use t<br />

5 GND 0V Interface GND, electrically connected to GND of<br />

the digital section<br />

8.13.4 Cable type and configuration [X5]<br />

Interface cable for serial interface (null modem), 3 cores.<br />

8.13.5 Connection notes [X5]<br />

Servo PC<br />

5<br />

9<br />

6<br />

1<br />

Female<br />

connector<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Connector housing<br />

9<br />

8<br />

7<br />

6<br />

Figure 32: Pin assignment RS232 null modem cable [X5]<br />

Connector housing<br />

108 E 732 GB<br />

14.12.2006<br />

5<br />

4<br />

3<br />

2<br />

1<br />

9<br />

8<br />

7<br />

6<br />

5<br />

1<br />

9<br />

6<br />

Female<br />

connector