8.13.3 Pin assignment [X5]<br />
Table 42: Pin assignment RS232 interface [X5]<br />
Pin no. Name Value Specification<br />
1 - - Not used<br />
6 - - Not used<br />
2 RxD 10 V / RI > 2kΩ Reception line, RS232 specification<br />
7 - - Not used<br />
3 TxD 10 V / RA < 2kΩ Transmission line, RS232 specification<br />
8 - - Not used<br />
4 +RS485 - reserved for optional RS485 use<br />
9 -RS485 - reserved for optional RS485 use t<br />
5 GND 0V Interface GND, electrically connected to GND of<br />
the digital section<br />
8.13.4 Cable type and configuration [X5]<br />
Interface cable for serial interface (null modem), 3 cores.<br />
8.13.5 Connection notes [X5]<br />
Servo PC<br />
5<br />
9<br />
6<br />
1<br />
Female<br />
connector<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Connector housing<br />
9<br />
8<br />
7<br />
6<br />
Figure 32: Pin assignment RS232 null modem cable [X5]<br />
Connector housing<br />
108 E 732 GB<br />
14.12.2006<br />
5<br />
4<br />
3<br />
2<br />
1<br />
9<br />
8<br />
7<br />
6<br />
5<br />
1<br />
9<br />
6<br />
Female<br />
connector