<strong>Fuxx</strong> <strong>Control</strong> <strong>ARS</strong> <strong>2320</strong> / <strong>ARS</strong> <strong>2340</strong> KUHNKE Automation<br />

8.12.4 Cable type and configuration [X4]<br />

The cable names given refer to cables made by Lapp. They have proven to be reliable and are<br />

successfully used in many applications. However, it is also possible to use comparable cables from<br />

other manufacturers, e.g. Lütze or Helukabel.<br />

Technical specification of the CAN bus cable: 2 pairs of 2 twisted cores, d ≥ 0.22 mm 2 ,<br />

shielded, loop resistance < 0.2 Ω/m, characteristic impedance 100-120 Ω.<br />

� LAPP KABEL UNITRONIC BUS CAN; 2 x 2 x 0.22; ∅ 7.6 mm,<br />

with Cu shielding<br />

For highly flexible applications:<br />

� LAPP KABEL UNITRONIC BUS-FD P CAN UL/CSA; 2 x 2 x 0.25; ∅ 8.4 mm,<br />

with Cu shielding<br />

8.12.5 Connection notes [X4]<br />

When cabling the controller via the CAN bus, make sure to observe the following<br />

information and notes in order to set up a stable and interference-free system. Improper<br />

cabling may cause the CAN bus to malfunction which in turn can cause the controller to<br />

shut down with an error due to safety reasons.<br />

The CAN bus provides an easy and fail-safe way of interconnecting all components of a system. This<br />

requires, however, compliance with the following notes on cabling.<br />

Figure 31: CAN bus cabling example<br />

106 E 732 GB<br />