17.02.2013 Views

Appendix KUHNKE Automation 10.2.6 Communication Ports (Ventura +) V.24 interface (RS 232) Transfer rate............................................. 9.6 - 57.6 kbps Fieldbus interfaces PROFIBUS function................................................ DP-Master available protocols............................... PROFIBUS-DP transfer rate ......................................... 9.6 kbps to 12 Mbps (adjustable by software) own station address ............................ 0...125 (adjustable by software) CANopen function................................................ NMT master, slave protocol................................................ DSP 301 transfer rate ......................................... 50 - 1000 kbps (adjustable by software) own station address ............................ 0...125 (adjustable by software) Indicators (Ventura +) Local status indication LED "RUN" .......................................... green LED, PLC program running LED "STOP" ........................................ red LED, program stopped LED "ERROR"..................................... red LED, operational controller problem LED "BUS1" ........................................ yellow LED, fieldbus 2 data traffic LED "BUS2" ........................................ yellow LED, fieldbus 3 data traffic 10.2.7 Permits CE ............................................................. yes UL ............................................................. upon request PNO certificate (PROFIBUS) ................... upon request 68 E 674 GB 07.03.2007

KUHNKE Automation Appendix 10.3 Dimensions, Ventura IPC 10.3.1 Outer Dimensions, Ventura IPC 300 211 60 To find a complete installation drawing (pdf file) browse the Internet for www.kuhnke.com "DOWNLOAD" or find the product descriptions available on the "Electronics" pages. E 674 GB 69 07.03.2007 134 54 191

Appendix KUHNKE Automation<br />

10.2.6 Communication Ports (<strong>Ventura</strong> +)<br />

V.24 interface (RS 232)<br />

Transfer rate............................................. 9.6 - 57.6 kbps<br />

Fieldbus interfaces<br />

PROFIBUS<br />

function................................................ DP-Master<br />

available protocols............................... PROFIBUS-DP<br />

transfer rate ......................................... 9.6 kbps to 12 Mbps (adjustable by software)<br />

own station address ............................ 0...125 (adjustable by software)<br />

CANopen<br />

function................................................ NMT master, slave<br />

protocol................................................ DSP 301<br />

transfer rate ......................................... 50 - 1000 kbps (adjustable by software)<br />

own station address ............................ 0...125 (adjustable by software)<br />

Indicators (<strong>Ventura</strong> +)<br />

Local status indication<br />

LED "RUN" .......................................... green LED, PLC program running<br />

LED "STOP" ........................................ red LED, program stopped<br />

LED "ERROR"..................................... red LED, operational controller problem<br />

LED "BUS1" ........................................ yellow LED, fieldbus 2 data traffic<br />

LED "BUS2" ........................................ yellow LED, fieldbus 3 data traffic<br />

10.2.7 Permits<br />

CE ............................................................. yes<br />

UL ............................................................. upon request<br />

PNO certificate (PROFIBUS) ................... upon request<br />