Ventura IPC Instruction Manual pdf - Kuhnke
Ventura IPC Instruction Manual pdf - Kuhnke
Ventura IPC Instruction Manual pdf - Kuhnke
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Appendix KUHNKE Automation<br />
Admissible ambient conditions<br />
Storage and transportation<br />
temperature ......................................... -25...+70 °C<br />
relative humidity .................................. 5% to 95% at 25°C (no condensation)<br />
vibration............................................... 5 to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9.8 m/ s 2 (1g)<br />
shock ................................................... w/o hard disk: 150 m/s 2 , 11 ms (15g)<br />
Operation<br />
ambient temperature ........................... vertical installation: 0 ... 50 °C<br />
relative humidity .................................. 5% to 80% at 25°C (no condensation)<br />
vibration............................................... 5 to 9 Hz: 3.5 mm, 9 Hz to 500 Hz: 9.8 m/ s 2 (1g)<br />
shock ................................................... w/o hard disk: 150 m/ s 2 , 11 ms (15g)<br />
10.2.2 Indicators<br />
Local status indication<br />
LED "RUN" .......................................... green LED, <strong>IPC</strong> ready<br />
LED "STOP" ........................................ red LED, program stopped<br />
LED "ERROR"..................................... red LED, controller won't start<br />
LED "HDD" .......................................... yellow LED, CF card access<br />
LED "BUS" .......................................... yellow LED, fieldbus data traffic<br />
LED "DVI"............................................ yellow LED, DVI display active<br />
LED "USB" .......................................... red LED, USB station short circuit<br />
10.2.3 Communication ports<br />
V.24 interface (RS 232)<br />
Transfer rate............................................. 2.4 - 57.6 kbps<br />
USB interface<br />
<strong>Ventura</strong> <strong>IPC</strong> 300.................................. USB 1.1 full speed/ high current<br />
<strong>Ventura</strong> <strong>IPC</strong> 700.................................. USB 2.0 high speed/ high current<br />
<strong>Ventura</strong> <strong>IPC</strong> 1000................................ USB 2.0 high speed/ high current<br />
Ethernet<br />
Compatibility............................................. 10/100 Mbps with RJ45<br />
CANopen<br />
Function.................................................... NMT master, slave<br />
Protocol .................................................... DSP 301<br />
Transfer rate............................................. 50 - 1000 kbps (adjustable by software)<br />
Own station address................................. 0...125 (adjustable by software)<br />
10.2.4 Hardware PLC (<strong>Ventura</strong>+)<br />
Power supply<br />
Supply voltage (DC) ................................ 24 VDC ±20% (19.2 to 28.8 V)<br />
Brief voltage interruption<br />
to Namur.............................................. Min. 15 ms (at 20.4 V).<br />
Max. 10 events per hour; recovery time min. 1s<br />
66 E 674 GB<br />
07.03.2007