Ventura IPC Instruction Manual pdf - Kuhnke
Ventura IPC Instruction Manual pdf - Kuhnke Ventura IPC Instruction Manual pdf - Kuhnke
Software KUHNKE Automation 7.4.3 Remote Debugging in Microsoft Visual Studio .NET 2003 This section tells you how to use Microsoft VS .NET 2003 CE to produce applications on the HOST development PC and to debug the source code with the application running on the actual target device, i.e. Ventura on a CE.NET platform. Remote Debugging is a component of the Microsoft development environment. Remote debugging is efficiently performed via Ethernet and an ActiveSync connection. The way to establishing an ActiveSync connection is explained in section 7.2 Connecting Using "ActiveSync. The text describes the "Smart Device Utility" variant as based on the add-on package of Windows CE utilities for Visual Studio .NET 2003. Prerequisites: • Microsoft Visual Studio .NET 2003 • To be able to run the Smart Device Utility for the debugging of the remote unit, you need "Windows CE .NET Utilities for Visual Studio .NET 2003.EXE". This Microsoft software is free and can be downloaded from the Internet. • Check that program folder 'Kuhnke' contains item SmartDeviceAuthentication. This file is delivered with the CE image. To connect: • Ventura IPC: Run tool SmartDeviceAuthentication and click on "Start'. Your Ventura IPC's IP address is displayed and tells you that the Ventura IPC is ready for communication. • HOST PC: Run Visual Studio 2003 on the development PC: Pick 'Smart Device Authentication Utility' from the 'Extra' menu, enter your Ventura IPC's IP address, and click on 'Set up device'. If opening a communication channel was successful, the following message will be displayed: 'Device has been prepped and ConmanClient.exe has been successfully launched'. Click on 'OK' and 'Close' to quit the utility. You are now connected with the Ventura IPC. In Visual Studio 2003, select 'Windows CE.NET device' as the target device. Choose 'TCP transport connection', click on 'Configure...', and enter Ventura IPC's IP address into the box labelled 'Use special IP address'. 54 E 674 GB 07.03.2007
KUHNKE Automation Software 7.5 Connecting with Ventura IPC's Software PLC (Windows CE) 7.5.1 Serial Interface Software PLC “PLCWinCE“ There are basically 3 channels available for communication: serial interface, Ethernet or Ethernet via a network. Serial (RS232) Ethernet Network • Connect a serial interface of the programming PC with Ventura IPC's serial interface labelled COM 1. Use a "null modem cable" with 9-pin female connectors. • In the CoDeSys development environment, define a new gateway channel using the following settings: • Switch on the power supply to Ventura IPC and run the software PLC. • From the Start menu, choose 'Programs', 'Kuhnke', 'PLCWinCE'. This launches the software PLC displaying the current status and connection details. E 674 GB 55 07.03.2007
- Page 3 and 4: KUHNKE Automation Table of Contents
- Page 5 and 6: KUHNKE Automation Table of Contents
- Page 7 and 8: 1 Introduction Performance in a nut
- Page 9 and 10: KUHNKE Automation Reliability, Safe
- Page 11 and 12: KUHNKE Automation Reliability, Safe
- Page 13 and 14: KUHNKE Automation Hardware 3 Ventur
- Page 15 and 16: KUHNKE Automation Hardware 3.4 Tech
- Page 17 and 18: KUHNKE Automation Hardware 3.6 Phys
- Page 19 and 20: KUHNKE Automation Hardware 3.7.4 Gr
- Page 21 and 22: KUHNKE Automation Hardware 3.7.7 Et
- Page 23 and 24: KUHNKE Automation Hardware 3.9 Stor
- Page 25 and 26: KUHNKE Automation Hardware 3.11 Ext
- Page 27 and 28: KUHNKE Automation Hardware 3.12.4 F
- Page 29 and 30: KUHNKE Automation Hardware 3.13 Ven
- Page 31 and 32: KUHNKE Automation Hardware 4 Instal
- Page 33 and 34: KUHNKE Automation Software 5 Start-
- Page 35 and 36: KUHNKE Automation Software Windows
- Page 37 and 38: KUHNKE Automation Software 6.1 Comp
- Page 39 and 40: KUHNKE Automation Software 6.2.3 OP
- Page 41 and 42: KUHNKE Automation Software 6.3.3 Ul
- Page 43 and 44: KUHNKE Automation Software 6.5 Vent
- Page 45 and 46: KUHNKE Automation Software 7.1.2 Co
- Page 47 and 48: KUHNKE Automation Software 7.1.5 OP
- Page 49 and 50: KUHNKE Automation Software • Deve
- Page 51 and 52: KUHNKE Automation Software This com
- Page 53: KUHNKE Automation Software Sometime
- Page 57 and 58: KUHNKE Automation Software 7.5.2 Et
- Page 59 and 60: KUHNKE Automation Software • Star
- Page 61 and 62: KUHNKE Automation Software 9 Mainte
- Page 63 and 64: KUHNKE Automation Appendix 10 Appen
- Page 65 and 66: KUHNKE Automation Appendix E 674 GB
- Page 67 and 68: KUHNKE Automation Appendix Max. pow
- Page 69 and 70: KUHNKE Automation Appendix 10.3 Dim
- Page 71 and 72: KUHNKE Automation Appendix 10.3.3 V
- Page 73 and 74: KUHNKE Automation Appendix 10.4 Ven
- Page 75 and 76: KUHNKE Automation Appendix 10.4.2 V
- Page 77 and 78: KUHNKE Automation Appendix 10.4.4 O
- Page 79 and 80: KUHNKE Automation Appendix 10.4.6 E
- Page 81 and 82: KUHNKE Automation Appendix 10.7.2 A
- Page 83 and 84: KUHNKE Automation Appendix 10.8 Ref
- Page 85: 10.10 Index application ...........
KUHNKE Automation Software<br />
7.5 Connecting with <strong>Ventura</strong> <strong>IPC</strong>'s Software PLC (Windows CE)<br />
7.5.1 Serial Interface<br />
Software PLC “PLCWinCE“<br />
There are basically 3 channels available for communication:<br />
serial interface, Ethernet or Ethernet via a network.<br />
Serial (RS232)<br />
Ethernet<br />
Network<br />
• Connect a serial interface of the programming PC with <strong>Ventura</strong> <strong>IPC</strong>'s<br />
serial interface labelled COM 1.<br />
Use a "null modem cable" with 9-pin female connectors.<br />
• In the CoDeSys development environment, define a new gateway<br />
channel using the following settings:<br />
• Switch on the power supply to <strong>Ventura</strong> <strong>IPC</strong> and run the software PLC.<br />
• From the Start menu, choose 'Programs', '<strong>Kuhnke</strong>', 'PLCWinCE'.<br />
This launches the software PLC displaying the current status and connection<br />
details.<br />
E 674 GB 55<br />