Software KUHNKE Automation 6.4 File Transfer The UltraVNC tool has a special dialog dedicated to controlling file transfer operations. • Click on the "Open File Transfer" button located on UltraVNC's control bar. The "File Transfer" dialog is displayed showing the complete folder structures of the two interconnecting PCs. There are various buttons for sending, receiving or deleting files. 42 E 674 GB 07.03.2007

KUHNKE Automation Software 6.5 Ventura SlotPLC Gateway Driver 6.5.1 Installation Before you can communicate with the Ventura SlotPLC via the DPRAM you must first install the appropriate driver in Ventura IPC +. At the time of delivery, installer SetupDPRamISA8K.exe is located in folder C:\Program Files\Ventura Tools\Install of your Ventura+. SetupDPRamISA8K.exe copies the gateway driver, i.e. DPRamISA.dll and DrvKuhnkeISA.dll, to WINDOWS/SYSTEM32 and enters DrvKuhnkeISA.dll into the registry. • Pick "Run" from the Windows Start menu. • Click on "Browse". • Navigate to C:\Program Files\Ventura Tools\Install and choose "SetupDPRamISA8K.exe". • Click on "OK" to actually run the installer. 6.5.2 To verify correct installation of the Ventura SlotPLC gateway drivers The following drivers will be added to your Windows\System32 folder during Target installation. • DPRamISA.dll • DrvKuhnkeISA.dll DrvKuhnkeISA.dll is the one entered into the Registry. To check do the following: • From WINDOWS' Start menu choose Run and enter "regedit". • Browse for folder KuhnkeISA645 \HKEY_LOCAL_MACHINE\.....(see status line in the figure below). For further information on the Ventura+ SlotPLC refer to instruction manual E 697 GB " Ventura SlotPLC". E 674 GB 43 07.03.2007

KUHNKE Automation Software<br />

6.5 <strong>Ventura</strong> SlotPLC Gateway Driver<br />

6.5.1 Installation<br />

Before you can communicate with the <strong>Ventura</strong> SlotPLC via the DPRAM you<br />

must first install the appropriate driver in <strong>Ventura</strong> <strong>IPC</strong> +.<br />

At the time of delivery, installer SetupDPRamISA8K.exe is located in folder<br />

C:\Program Files\<strong>Ventura</strong> Tools\Install of your <strong>Ventura</strong>+.<br />

SetupDPRamISA8K.exe copies the gateway driver, i.e. DPRamISA.dll and<br />

Drv<strong>Kuhnke</strong>ISA.dll, to<br />

WINDOWS/SYSTEM32 and enters Drv<strong>Kuhnke</strong>ISA.dll into the registry.<br />

• Pick "Run" from the Windows Start menu.<br />

• Click on "Browse".<br />

• Navigate to C:\Program Files\<strong>Ventura</strong> Tools\Install and choose "SetupDPRamISA8K.exe".<br />

• Click on "OK" to actually run the installer.<br />

6.5.2 To verify correct installation of the <strong>Ventura</strong> SlotPLC gateway drivers<br />

The following drivers will be added to your Windows\System32 folder during<br />

Target installation.<br />

• DPRamISA.dll<br />

• Drv<strong>Kuhnke</strong>ISA.dll<br />

Drv<strong>Kuhnke</strong>ISA.dll is the one entered into the Registry. To check do the following:<br />

• From WINDOWS' Start menu choose Run and enter "regedit".<br />

• Browse for folder <strong>Kuhnke</strong>ISA645 \HKEY_LOCAL_MACHINE\.....(see<br />

status line in the figure below).<br />

For further information on the <strong>Ventura</strong>+ SlotPLC refer to instruction manual<br />

E 697 GB " <strong>Ventura</strong> SlotPLC".<br />

E 674 GB 43<br />