KUHNKE Automation Software<br />
Windows XP, direct connection<br />
• Go to Windows Start and choose<br />
Start – Settings – Network Connections: pick LAN connection from list,<br />
Properties<br />
• Go to tab "General", find the list of elements, choose "Internet protocol<br />
(TCP/IP)" and click on Properties.<br />
• Still on tab "General" choose "Use this IP address" and enter any IP<br />
address as appropriate,<br />
e.g.: "169.254.112.85", subnet mask "255.255.255.0"<br />
A direct connection requires the "File and printer release" to be ticked and a<br />
firewall, if any, to be disabled at least for the time of this connection.<br />
5.2.3 CoDeSys Target System Setting on the Programming PC<br />
• Run PLCWinCE on the <strong>Ventura</strong> <strong>IPC</strong><br />
(Start – Programs – KUHNKE – PLCWinCE)<br />
• Create a new CoDeSys project and choose "KUHNKE PC Control <strong>Ventura</strong>"<br />
as its target system<br />
• Choose "Online – Communication Parameters" to set up a TCP/IP connection<br />
using the IP address you previously specified for the <strong>Ventura</strong><br />
<strong>IPC</strong>.<br />
E 674 GB 35<br />
07.03.2007