Hardware KUHNKE Automation 3.12.6 Serial RS 232 Interface 5 9 4 8 3 7 22 6 1 Combi I/Os DI/DO 0 and DI/DO 2 are designed to also act as event counters up to 10 kHz. If combined with a 24V incremental encoder, these combi I/Os also provide A, B, Ref counter functions. Their actual function is set at the configuration stage. The maximum nominal current of every combi I/O output is 0.5 A. If a combi I/O is used as an output, mind that no external input signal must go through that port at the same time. The main practical use of the RS 232 port is to attach an external programming device to it. However, you could also use it for exchanging data with dialog terminals, PCs and other such devices. Connector 9-pin D-SUB, female Pin Function 1 - 2 TxD 3 RxD 4 - 5 GND 6 - 7 - 8 - 9 - Housing shielding If the interface is used for communication with a CoDeSys programming system, choose menu item "Communication Parameters" to set its baud rate to 38400 baud. The normal programming cable from the accessories range connects the Ventura+ hardware PLC with the programming device. Part number 691.151.09 Length 3.0 m Assignment 1 : 1 28 E 674 GB 07.03.2007
KUHNKE Automation Hardware 3.13 Ventura+ Hardware PLC Controls 3.13.1 "RESET" Button RUN STOP ERROR BUS2 BUS3 RESET 3.14 Ventura Indicators 3.14.1 Status LEDs RUN STOP ERROR BUS2 BUS3 RESET The Reset button is located on the front of the device, underneath the Ventura's status indicators. The reset / cold boot will affect the Ventura+ hardware PLC only, but not the PC. To avoid it being pushed unintentionally, the Reset button can be operated using a pointed object (pen, screwdriver) only. Label LED Description RUN OFF GREE N STOP OFF RED ERROR OFF RED BUS2 OFF YEL- LOW BUS3 OFF YEL- LOW FLASHI NG PLC program not loaded, not started PLC program runs cyclically PLC program runs cyclically PLC program not loaded, not started No system error Operative controller problem Ready OK, all stations connected to bus Warning, station missing Flash code imitates address of missing station E 674 GB 29 07.03.2007
- Page 1 and 2: Kuhnke Electronics Instruction Manu
- Page 3 and 4: KUHNKE Automation Table of Contents
- Page 5 and 6: KUHNKE Automation Table of Contents
- Page 7 and 8: 1 Introduction Performance in a nut
- Page 9 and 10: KUHNKE Automation Reliability, Safe
- Page 11 and 12: KUHNKE Automation Reliability, Safe
- Page 13 and 14: KUHNKE Automation Hardware 3 Ventur
- Page 15 and 16: KUHNKE Automation Hardware 3.4 Tech
- Page 17 and 18: KUHNKE Automation Hardware 3.6 Phys
- Page 19 and 20: KUHNKE Automation Hardware 3.7.4 Gr
- Page 21 and 22: KUHNKE Automation Hardware 3.7.7 Et
- Page 23 and 24: KUHNKE Automation Hardware 3.9 Stor
- Page 25 and 26: KUHNKE Automation Hardware 3.11 Ext
- Page 27: KUHNKE Automation Hardware 3.12.4 F
- Page 31 and 32: KUHNKE Automation Hardware 4 Instal
- Page 33 and 34: KUHNKE Automation Software 5 Start-
- Page 35 and 36: KUHNKE Automation Software Windows
- Page 37 and 38: KUHNKE Automation Software 6.1 Comp
- Page 39 and 40: KUHNKE Automation Software 6.2.3 OP
- Page 41 and 42: KUHNKE Automation Software 6.3.3 Ul
- Page 43 and 44: KUHNKE Automation Software 6.5 Vent
- Page 45 and 46: KUHNKE Automation Software 7.1.2 Co
- Page 47 and 48: KUHNKE Automation Software 7.1.5 OP
- Page 49 and 50: KUHNKE Automation Software • Deve
- Page 51 and 52: KUHNKE Automation Software This com
- Page 53 and 54: KUHNKE Automation Software Sometime
- Page 55 and 56: KUHNKE Automation Software 7.5 Conn
- Page 57 and 58: KUHNKE Automation Software 7.5.2 Et
- Page 59 and 60: KUHNKE Automation Software • Star
- Page 61 and 62: KUHNKE Automation Software 9 Mainte
- Page 63 and 64: KUHNKE Automation Appendix 10 Appen
- Page 65 and 66: KUHNKE Automation Appendix E 674 GB
- Page 67 and 68: KUHNKE Automation Appendix Max. pow
- Page 69 and 70: KUHNKE Automation Appendix 10.3 Dim
- Page 71 and 72: KUHNKE Automation Appendix 10.3.3 V
- Page 73 and 74: KUHNKE Automation Appendix 10.4 Ven
- Page 75 and 76: KUHNKE Automation Appendix 10.4.2 V
- Page 77 and 78: KUHNKE Automation Appendix 10.4.4 O
Hardware KUHNKE Automation<br />
3.12.6 Serial RS 232 Interface<br />
5<br />
9<br />
4<br />
8<br />
3<br />
7<br />
22<br />
6<br />
1<br />
Combi I/Os DI/DO 0 and DI/DO 2 are designed to also act as event counters<br />
up to 10 kHz. If combined with a 24V incremental encoder, these combi I/Os<br />
also provide A, B, Ref counter functions.<br />
Their actual function is set at the configuration stage.<br />
The maximum nominal current of every combi I/O output is 0.5 A.<br />
If a combi I/O is used as an output, mind that no external input signal must<br />
go through that port at the same time.<br />
The main practical use of the RS 232 port is to attach an external programming<br />
device to it. However, you could also use it for exchanging data with<br />
dialog terminals, PCs and other such devices.<br />
Connector 9-pin D-SUB, female<br />
Pin Function<br />
1 -<br />
2 TxD<br />
3 RxD<br />
4 -<br />
5 GND<br />
6 -<br />
7 -<br />
8 -<br />
9 -<br />
Housing shielding<br />
If the interface is used for communication with a CoDeSys programming<br />
system, choose menu item "Communication Parameters" to set its baud rate<br />
to 38400 baud.<br />
The normal programming cable from the accessories range connects the<br />
<strong>Ventura</strong>+ hardware PLC with the programming device.<br />
Part number 691.151.09<br />
Length 3.0 m<br />
Assignment 1 : 1<br />
28 E 674 GB<br />
07.03.2007