Hardware KUHNKE Automation<br />

3.7.5 Interface "PS / 2"<br />

2<br />

1<br />

4<br />

3<br />

6<br />

5<br />

3.7.6 Interface "USB1","USB2"<br />

<strong>Ventura</strong> <strong>IPC</strong> features a PS / 2 interface that an external keyboard and/or an<br />

external mouse can be attached to.<br />

Connector 6-pin mini-DIN, female<br />

Pin Signal Function<br />

1 DAT (mouse) Data line (mouse)<br />

2 DAT (keyboard) Data line (keyboard)<br />

3 GND Earth<br />

4 P5VFK +5 V (fused)<br />

5 CLK (mouse) Clock line (mouse)<br />

6 CLK (keyboard) Clock line (keyboard)<br />

Shell Shield shielding<br />

To attach a keyboard or a mouse or both to the interface, a PS2 splitter (Y<br />

cable) is required.<br />

The USB adapter is the port for external peripherals such as CD-ROM<br />

drives, printers, modems or mouse and keyboard. The power supply unit for<br />

the USB peripherals supplies up to 500 mA output current and is fused by<br />

means of a maintenance-free "USB current-limiting circuit breaker". A short<br />

circuit or overload thus switches off the power supply and the "USB" status<br />

indicator lights up red.<br />

Connector type A, male<br />

Pin Signal Function<br />

1 VBUS (5 VDC) +5V (fused) for external USB port<br />

2 D- data+, USB channel 0<br />

3 D+ data-, USB channel 0<br />

4 GND GND for external USB port<br />

Shell Shield shielding<br />

The USB interfaces are made for attaching USB peripherals to. Due to the<br />

wide range of commercially available USB units and operating systems,<br />

KUHNKE cannot warrant that they will function properly.<br />

The standard demands 5m as the warranted length of line. Putting in a USB<br />

repeater you can extend lines to a maximum of 20m.<br />

Hot Plug-ready peripherals can be attached to the USB port while the PC is<br />

running.<br />

To comply with the noise immunity demanded by standard IEC 61131, the<br />

use of suitable USB cables is recommended. The accessory cables supplied<br />

by KUHNKE Automation GmbH & Co. ( 10.7.2 Accessories) are tested for<br />

compliance.<br />

Wiring of all installations should bear IT-specific needs in mind.<br />

20 E 674 GB<br />