Production range<br />

pumps:<br />

Pumps with magnet drive<br />

E Centrifugal pumps<br />

according to DIN EN 22858<br />

E Centrifugal pumps<br />

according to ANSI B73.3<br />

E Centrifugal pumps for refinery<br />

and petrochemical applications<br />

according to API 685<br />

E Centrifugal pumps for high<br />

pressure applications<br />

E Centrifugal pumps for high<br />

temperature applications<br />

E Centrifugal pumps for liquid<br />

containing solids<br />

E Centrifugal pumps, self-priming<br />

E Multistage pumps, tension-rod or<br />

barrel-type construction<br />

E Side channel pumps, self-priming<br />

E Screw pumps<br />

E Submerged centrifugal pumps<br />

E Double suction centrifugal pumps<br />

<strong>Klaus</strong> <strong>Union</strong> GmbH & Co. KG<br />

Blumenfeldstr. 18<br />

44795 Bochum<br />

Germany<br />

Phone +49 234 45 95 - 0<br />

Fax +49 234 45 95 - 7000<br />

E-Mail info@klaus-union.de<br />

Internet www.klaus-union.de<br />

Pumps with shaft sealing<br />

E Centrifugal pumps<br />

according to DIN EN 22858<br />

E Multistage pumps, tension-rod or<br />

barrel-type construction<br />

E Horizontal and vertical propeller pumps<br />

E Bottom-flange propeller pumps<br />

E Submerged centrifugal pumps<br />

E Double-suction chemical pumps<br />

Production range<br />

valves:<br />

E Valves, T-pattern<br />

E Valves, Y-pattern<br />

E Gate valves, isomorphous<br />

construction series<br />

E Gate valves, wedge or wedge plates<br />

E Relief valves<br />

E Check valves<br />

E Sight glasses<br />

E Strainers<br />

E Filters<br />

E Bottom valves<br />

KU_<strong>GV</strong>_E_01/11_0001<br />

S E R V I C E<br />

<strong>MULTISTAGE</strong> <strong>CENTRIFUGAL</strong><br />

<strong>PUMP</strong> <strong>TYPE</strong> <strong>SLM</strong> <strong>GV</strong><br />

SEALLESS WITH MAGNET DRIVE


2<br />

Sealless multistage centrifugal<br />

construction series <strong>SLM</strong> <strong>GV</strong><br />

As a member of <strong>Klaus</strong> <strong>Union</strong>’s successful<br />

modular pump concept, the <strong>SLM</strong> <strong>GV</strong> further<br />

extends our sealless application coverage.<br />

The <strong>SLM</strong> <strong>GV</strong> pump is primarily used for applications<br />

requiring high delivery heads.<br />

Requirements have increased, become<br />

more complex, and more specific in recent<br />

years, particularly in the chemical and<br />

petrochemical industry, where pumps handle<br />

aggressive, toxic, and explosive liquids under<br />

highest safety requirements. <strong>Klaus</strong> <strong>Union</strong>’s<br />

new <strong>SLM</strong> <strong>GV</strong> pump series addresses today‘s<br />

industry requirements – and offers new<br />

efficient and demand-driven solutions.<br />

<strong>Klaus</strong> <strong>Union</strong> satisfies these requirements<br />

with over fifty years of experience in development,<br />

construction, manufacturing, and in the<br />

application of magnet drive pumps.<br />

<strong>SLM</strong> <strong>GV</strong> – “V” stands for “variable” through<br />

modular design. Features and benefits of the<br />

modular “V-Concept” are:<br />

E Few individual components –<br />

multi-functional, individual application<br />

E Greater safety over the<br />

entire construction range<br />

E Suitable for serial fabrication<br />

at competitive prices<br />

E Standard modules offer<br />

many design variations<br />

E Energy efficient systems<br />

E Maximum flexibility and interchangeability<br />

E Off-the-shelf availability of parts,<br />

components and accessories<br />

The construction series <strong>SLM</strong> <strong>GV</strong> covers the<br />

complete performance range of multistage<br />

centrifugal pumps. Pumps for high system<br />

pressure applications are also available upon<br />

request.<br />

<strong>SLM</strong> <strong>GV</strong>OT Barrel construction type design <strong>SLM</strong> <strong>GV</strong>S tension rod construction design<br />

Safety and environmental protection<br />

Quality assurance<br />

A major component of our Company ethos is<br />

to ensure the highest quality of our products.<br />

Existing quality assurance procedures with our<br />

suppliers are constantly monitored from order<br />

placement, goods inward through to final<br />

assembly. This quality assurance system, developed<br />

on modern principles, complies with<br />

the requirements of international regulations.<br />

<strong>Klaus</strong> <strong>Union</strong> is a DIN EN ISO 9001 certified<br />

Company.<br />

Pumping of<br />

E Acids<br />

E Lyes<br />

E Hydrocarbon<br />

E Hot water (boiler water)<br />

E Heat transfer liquids<br />

E Liquid gas<br />

E Aggressive, explosive and<br />

toxic liquids<br />

Domains<br />

E Chemical and petrochemical industries<br />

E Refrigeration and heat<br />

E Liquid gas plants<br />

E Galvanic engineering<br />

E Power stations<br />

E Tank installations<br />

Performance range<br />

Flow rate: Q = up to 350 m³ /h<br />

Delivery head: H = up to 700 m L. C.<br />

Higher flow rates and delivery heads<br />

upon request<br />

Pressure ratings/temperature ranges<br />

Standard construction: PN 40 / PN 63<br />

at 120 °C<br />

Temperature range: -120 °C up to +450 °C<br />

Higher pressure ratings upon request<br />

3


1.<br />

2.<br />

3.<br />

4.<br />

5.<br />

Constructional details <strong>SLM</strong> <strong>GV</strong>OT<br />

Barrel-type construction<br />

6.<br />

7.<br />

8.<br />

9.<br />

10.<br />

11.<br />

12.<br />

1. Barrel-type pump casing<br />

PN 40 / PN 63 at 120 °C;<br />

Suction nozzle with horizontal inlet<br />

Optionally with heating jacket<br />

2. Flushing system<br />

Pressurised to safely handle liquids close<br />

to boiling<br />

3. Radial journal bearing<br />

Radial journal bearing behind<br />

the suction impeller<br />

4. Impellers<br />

Arranged in series;<br />

First stage with suction impeller<br />

Optionally with suction inducer to reduce<br />

required NSPH<br />

5. Balancing holes<br />

Optimized thrust loads over the entire<br />

operating range via hydraulic measures<br />

6. Outer magnet carrier<br />

Two piece with rub ring on the<br />

intermediate lantern<br />

7. Isolation shell<br />

Self-venting and fully drainable;<br />

Vortex breaker<br />

8. Journal bearings<br />

Double bearing made of SSiC;<br />

Counter centred combination for universal<br />

utilisation over a wide temperature range<br />

9. Bearing support<br />

Oil-lubricated anti-friction bearings:<br />

<strong>SLM</strong> <strong>GV</strong>OT design<br />

Optionally with grease-lubricated<br />

anti-friction bearings: <strong>SLM</strong> <strong>GV</strong>ST design<br />

10. Inner magnet carrier<br />

With rub ring on the journal bearing bush<br />

11. Intermediate lantern<br />

With outer magnet carrier rub ring and<br />

assembly/disassembly guidance<br />

12. Static gasket<br />

Merely two static gaskets on isolation shell<br />

and casing<br />

4 5


Head [ m ]<br />

Head [ m ]<br />

Performance curve 50Hz<br />

135<br />

120<br />

105<br />

90<br />

75<br />

60<br />

45<br />

15<br />

0<br />

0<br />

550<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

50<br />

0<br />

0<br />

<strong>SLM</strong> <strong>GV</strong><br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

<strong>SLM</strong> <strong>GV</strong><br />

30<br />

065-032-160/6<br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

065-032-160/6<br />

100<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160<br />

50 100 150 200 250 300 350 400 450 500 550 600 650 700<br />

Performance curve 50Hz<br />

1450 1/min<br />

2900 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

25 50 75 100 125 150 175 200 225 250 275 300<br />

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

1800<br />

1600<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

Head [ m ]<br />

Head [ m ]<br />

Performance curves <strong>SLM</strong> <strong>GV</strong><br />

Performance curve 60Hz<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

065-032-160/6<br />

40<br />

20<br />

750<br />

700<br />

600<br />

500<br />

400<br />

300<br />

100<br />

0<br />

0<br />

0<br />

0<br />

<strong>SLM</strong> <strong>GV</strong><br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

200<br />

<strong>SLM</strong> <strong>GV</strong><br />

065-032-160/6<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5 <strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

1750 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

15 30 45 60 75 90 105 120 135 150 165 180 190<br />

50 100<br />

200<br />

300<br />

400<br />

500<br />

600<br />

700<br />

800<br />

Performance curve 60Hz<br />

<strong>SLM</strong> <strong>GV</strong><br />

080-040-200/6<br />

<strong>SLM</strong> <strong>GV</strong> 100-050-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 125-065-250/5<br />

<strong>SLM</strong> <strong>GV</strong> 150-080-250/4<br />

3500 1/min<br />

<strong>SLM</strong> <strong>GV</strong> 150-100-250/4<br />

25 50 75 100 125 150 175 200 225 250 275 300 325 350 375<br />

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600<br />

6 7<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

250<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]<br />

2250<br />

2000<br />

1750<br />

1500<br />

1250<br />

1000<br />

750<br />

500<br />

250<br />

Head [ ft ]<br />

Flowrate<br />

[ m³/h ]<br />

Flowrate<br />

[ usgpm ]