Impacts<br />

Reduced air quality due to emissions<br />

from construction equipment,<br />

trucks, earth moving machinery,<br />

asphalt production, and temporary<br />

boilers, etc.<br />

Increased turbidity in surface waters<br />

due to erosion from site clearing,<br />

earthwork, and road and building<br />

construction.<br />

Pollution of surface waters from<br />

sanitary sewage, construction waste<br />

disposal, and site stormwater runoff.<br />

Pollution of surface waters from fuel<br />

or other hazardous material spills.<br />

Table 8-2<br />

lmpacts and Mitigating Measures<br />

Mitigating Measure<br />

The chosen location of the construction site is<br />

approximately 2 km away from the nearest<br />

populated area which effectively elimi.pates the<br />

impact of reduced air quality on the local<br />

population. All diesel and gasoline powered<br />

equipment used on site will be properly maintained<br />

to ensure efficient operation.<br />

Silt fences and/or hay bales will be erected in the<br />

areas of soil disturbing activities. Vegetation will<br />

be maintained and/or replaced as necessary.<br />

Sanitary sewage will be collected and removed by<br />

tank truck until an onsite treatment plant is<br />

constructed and operating properly. Construction<br />

waste will be disposed according to local<br />

regulations. Site stormwater runoff will be<br />

directed to an onsite stormwater retention pond<br />

intended to reduce siltation and allow for floating<br />

oil to be skimmed.<br />

Fuel storage tanks will have secondary<br />

containment sufficient to hold the volume of the<br />

largest tank plus 10%. Hazardous materials will be<br />

stored in approved structures providing fire<br />

prevention and secondary containment capabilities.<br />

An Emergency Response Plan will be prepared<br />

detailing the procedures to be followed by the<br />

contractors onsite emergency response team to<br />

prevent spilled material from reaching surface<br />

waters. In the event spilled material reaches a<br />

surface water body procedures to minimize the<br />

impact by rapid containment prior to cleanup will<br />

be implimented.<br />

PAGE 8-3<br />