@ Established waste water composition requirements:<br />

Floating pollutants - none.<br />

Odor - 2 points at most.<br />

Color - no.<br />

Water temperature - should not exceed water reservoir natural temperature by<br />

more than 5 "C.<br />

pH level - 5.5 to 8.5.<br />

Oxygen - at least 4 mg/L.<br />

E. Coli index - 1000 at most.<br />

The proposed design will conform to the effluent discharge quality of the<br />

established standards and will have no significant impact on surface water.<br />

5.2.1.3 lmpacts on Land Resources<br />

lmpacts on land resources within the affected area will be determined by:<br />

- agricultural land allocation<br />

- impacts of emissions from the power plant on soils.<br />

@ Chapter "<strong>Project</strong> description" is indicative of the areas allocated for construction.<br />

Land transfer is properly documented and is in agreement with land use structure<br />

of the Mostovskoy district. Table 5.12 is indicative of the repayment rates to<br />

compensate for agricultural production loss.<br />

a operation.<br />

Impact of power plant emissions on soil is covered in section 5.2.1.7 of section<br />

"Impacts on agriculture".<br />

5.2.1.4 Noise<br />

Judging by the experience of construction and operation of thermal power plants,<br />

as well as previous studies and measurements of noise levels at existing thermal<br />

power plants performed by NIIISF, ME1 and other organizations, modern power<br />

plant equipment causes noise above permissible levels inside buildings, at the<br />

industrial site and to the adjacent development territories.<br />

Major sources of noise inside buildings are combustion and steam turbine units,<br />

pumps, steam pipelines, ventilation units, valves and other equipment. All the<br />

noise sources mentioned are continuous, except exhaust valves, with 24-hour<br />

PAGE 5-21