12 <strong>Control</strong>ler evaluation<br />
Even though the MUTE car prototype will not be ready be<strong>for</strong>e autumn 2011, some testing<br />
was done with the help <strong>of</strong> simulations. In this way, the functioning <strong>of</strong> the controller in<br />
combination with the available hardware is shown.<br />
12.1 Hardware-in-the-loop test<br />
The leading institute <strong>for</strong> the MUTE development, the Lehrstuhl für Fahrzeugtechnik Mün-<br />
chen has built up a hardware-in-the-loop test rig. A special computer simulates the car<br />
<strong>an</strong>d some sensors. This simulation is communicating over CAN-busses 1 with the Mi-<br />
croAutoBox car computer (described in Section 10.7). The actuator <strong>an</strong>d sensor hardware<br />
is directly connected to this box. With this configuration, the interaction <strong>of</strong> electrics,<br />
hardware control s<strong>of</strong>tware <strong>an</strong>d the (simulated) car c<strong>an</strong> already be tested. A schematic<br />
drawing <strong>of</strong> the test rig (showing only the relev<strong>an</strong>t hardware components <strong>for</strong> the climati-<br />
sation) is found in Figure 12.1.<br />
In this way, tests <strong>of</strong> the HVAC-unit <strong>an</strong>d first parameterisations were done. One very<br />
import<strong>an</strong>t result is the execution time <strong>of</strong> the optimiser algorithm. Its turnaround time was<br />
measured to be ������ seconds (in the automatic mode). This equals a processor load <strong>of</strong><br />
0.09% with the sample time <strong>of</strong> two seconds. The disturb<strong>an</strong>ce estimator also showed a very<br />
short turnaround time <strong>of</strong> 0.00030 seconds. The remaining control parts are included in<br />
a“��� �”-task because have the same sample time as other blocks in the MUTE s<strong>of</strong>tware<br />
<strong>an</strong>d c<strong>an</strong> there<strong>for</strong>e not be regarded separately. This task showed a turnaround time <strong>of</strong><br />
0.00028 seconds. As the turnaround times are very low, they showed to be dependent on<br />
the overall system sample time. This is set to 10 milliseconds.<br />
1 <strong>Control</strong>ler-area-network, a st<strong>an</strong>dard bus in vehicles.