10 Hardware <strong>an</strong>d characteristics <strong>of</strong> the MUTE prototype 108<br />

<strong>an</strong>d “turn counterclockwise”. These are fed to H bridges 1 , which power the motors which<br />

are running on 12 Volt. The main f<strong>an</strong> is driven by a ��� PWM signal whose active cycle<br />

is given by <strong>an</strong> <strong>an</strong>alogue output. The servo motor - potentiometer combination <strong>for</strong> the<br />

heater control might be replaced with a digital potentiometer integrated circuit.<br />

10.8 Parameterisation <strong>for</strong> the MUTE car<br />

Some parameters related to the MUTE car could only be estimated since the car is not<br />

built, yet. They have to be measured <strong>an</strong>d adapted once a prototype exists in order to<br />

achieve the best control.<br />

The heat tr<strong>an</strong>sfer c<strong>an</strong> be measured by testing how much heating power is required<br />

to keep the car’s interior at a const<strong>an</strong>t temperature. A better estimation <strong>of</strong> the heat<br />

capacity <strong>of</strong> the interior parts (seats etc.) built into the prototype a c<strong>an</strong> be done.<br />

The f<strong>an</strong> characteristics in the system with all ducts <strong>an</strong>d outlets attached has to<br />

be measured <strong>an</strong>d the curve (shown in Figure 10.4) has to be adapted. Moreover, the<br />

relationships between the flap opening <strong>an</strong>gles <strong>an</strong>d the air mass flow percentage passing it<br />

have to be qu<strong>an</strong>tified with the ducts attached (cf. Section 3.2.5). All other air flow related<br />

values in the objectives could be corrected as well. The air speed on the windscreen<br />

(equation 3.11 <strong>an</strong>d the air speed towards the passengers (cf. Section 10.2) c<strong>an</strong> be adapted<br />

to measurement data.<br />

One import<strong>an</strong>t relationship to find is the one between the battery cooling air<br />

flow <strong>an</strong>d its PWM-set value (see Section 10.5). The heater potentiometer <strong>an</strong>gle to set-<br />

temperature will also need calibration.<br />

1 A semiconductor device used <strong>for</strong> motor control.