12.02.2013 Views

HPLC Accessories - KNAUER Advanced Scientific Instruments

HPLC Accessories - KNAUER Advanced Scientific Instruments

HPLC Accessories - KNAUER Advanced Scientific Instruments

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HPLC</strong> · SMB · OSMOMETRY<br />

Catalog<br />

Separating Techniques 2001<br />

<strong>HPLC</strong> / SMB<br />

Systems, <strong>Instruments</strong>, Software,<br />

<strong>Accessories</strong>, and Spare Parts.<br />

DIN<br />

EN ISO<br />

9001<br />

• C E R T I F I E D •<br />

Q U A L I T Y M A N A G E M E N T


Preface<br />

Dear Customer,<br />

<strong>KNAUER</strong> has been developing and distributing osmometers and <strong>HPLC</strong> instruments<br />

for nearly 40 years. During this 40 year experience we have continuously sought to<br />

maintain the highest level of quality in all of the instruments and services that we offer.<br />

We would also like to acknowledge the fact that our success in the past four decades<br />

would not have been possible without you, our customer. Your input as to new ideas<br />

and improvement has been a major factor in our advancement as a company.<br />

Especially today, as market conditions and demands change faster than ever, we<br />

rely on your feedback and we further commit ourselves to strive to provide you with<br />

reliable and market oriented products. We do this all within the framework of the<br />

demanding requirements of DIN EN ISO 9001, our quality management system.<br />

We would like to offer you help to an easy start as well as a comprehensive overview<br />

in our extended new and improved product program catalogue, Separating<br />

Techniques 2001 – <strong>HPLC</strong> / SMB. In particular, we would like to introduce both the<br />

new UNEXAS System for online sample preparation with linked chromatographic<br />

analysis and the new Amino Acid Analyzer A100 which have broadened our product<br />

range of <strong>HPLC</strong> system solutions. The new version of the <strong>HPLC</strong> Software, ChromGate ®,<br />

ensures that our system software stays up-to-date.<br />

For product information, a quotation, or order feel free to contact us at:<br />

+49 (0)30 8 09 72 70.<br />

We would like to thank you for your continuing confidence and are already looking<br />

forward to working with you in the future. We hope to see you soon at one of our<br />

<strong>KNAUER</strong> symposiums or at one of the many exhibitions in which we participate.<br />

Best regards,<br />

Alexandra Knauer Bernward Rittgerodt<br />

Managing Director and Owner Managing Director<br />

The production of this catalog<br />

was financially supported<br />

by the European Union.<br />

1


Extended Products and Services<br />

2<br />

Osmometers<br />

<strong>HPLC</strong> Columns<br />

Electronic Newsletter<br />

� Vapor Pressure Osmometer<br />

For molecular weight determination of up to 40,000 g/mol<br />

� Membrane Osmometer<br />

For molecular weight determination between 10,000 and 1,000,000 g/mol<br />

� Semimicro Osmometer<br />

For determining the total osmality of physiological fluids<br />

<strong>KNAUER</strong> has been developing and distributing osmometers for medicine, chemistry,<br />

polymer chemistry, and clinical diagnostics with great success for nearly 40 years.<br />

Feel free to request further detailed product information to be sent to you without<br />

obligation.<br />

Vapor Pressure Osmometer K-7000<br />

<strong>KNAUER</strong> offers an extensive range of columns and phases for <strong>HPLC</strong>. Our 25 years of<br />

experience in the field of chromatographical separation techniques has been invested<br />

into each and every delivered column. High quality and performance sorbents such<br />

as our Eurospher provide for perfect analysis. Every step in the manufacturing process<br />

of separation columns is optimized. Strict criteria guarantee outstanding quality in<br />

batch-to-batch reproduction.<br />

Request a copy of our »Columns and Phases for <strong>HPLC</strong>« catalog today.<br />

The <strong>KNAUER</strong> report is our company newsletter written two to three times a year.<br />

It keeps our customers informed about the newest products in our development<br />

department, applications, events and exhibitions, and advancement and changes<br />

within our company.<br />

There is a reply card attached to each report making it simple and time efficient for<br />

you to request further information regarding any of the articles.<br />

Staying »up-to-date« with a company that rapidly advances is important in today’s<br />

technology world! Therefore, don’t wait to get your copy of our report second hand!<br />

Subscribe free of charge today per E-mail, fax, or by giving us a call!


Table of Contents<br />

<strong>HPLC</strong>-Systems, <strong>Instruments</strong>, Software, <strong>Accessories</strong>, and Spare Parts<br />

Page<br />

<strong>HPLC</strong> System Solutions System proposal »Helios« – Premium <strong>HPLC</strong> analysis with maximum flexibility ....... 5<br />

System proposal »Asteris« – Isocratic stand-alone system ..................................... 6<br />

System proposal »Sacharis« – Automated sugar analysis ...................................... 7<br />

System proposal »Metis« – Optimized for semi-preparative purification ................. 8<br />

System proposal »Demeter« – Versatile semi-preparative and analytical <strong>HPLC</strong> ........ 9<br />

System proposal »Anemos« – Ultimate modular system for preparative <strong>HPLC</strong> ........ 10<br />

System proposal »Herakles« – Compact high-performance preparative system ...... 11<br />

System proposal »Zefiros« – Our exclusive explosion proof preparative system ...... 12<br />

CHANCE – The smallest <strong>HPLC</strong> system in the world .............................................. 13<br />

<strong>KNAUER</strong> Software ChromGate ® – GLP compliant instrument and data management ....................... 14<br />

Online SPE and <strong>HPLC</strong> UNEXAS – Universal Extraction and Sample Preparation ...................................... 15<br />

Simulated Moving Bed<br />

Chromatography (SMB) SMB production facility CSEP ® C912 .................................................................... 16<br />

SMB pilot system CSEP ® C916 ............................................................................. 17<br />

Amino Acid Analysis Amino Acid Analyzer A100 ................................................................................... 18<br />

Pumps and <strong>Accessories</strong> WellChrom <strong>HPLC</strong> Pump K-1001 ........................................................................... 19<br />

WellChrom <strong>HPLC</strong> Pump K-501 ............................................................................. 20<br />

WellChrom <strong>HPLC</strong> Pump K-120 ............................................................................. 21<br />

<strong>Accessories</strong> and Spare Parts for <strong>HPLC</strong> Pumps<br />

K-100, K-120, K-500, K-501, K-1000, and K-1001 ............................................... 22<br />

WellChrom Preparative <strong>HPLC</strong> Pump K-1800 ......................................................... 23<br />

WellChrom Pneumatic Pump K-1900 ................................................................... 24<br />

Preparative Pump Heads and <strong>Accessories</strong> ............................................................. 25<br />

WellChrom Solvent-Organizer K-1500 .................................................................. 26<br />

Detectors and <strong>Accessories</strong> WellChrom Diode Array Detector K-2700 ............................................................. 27<br />

WellChrom Fast Scanning Spectro-Photometer K-2600 ........................................ 28<br />

WellChrom Spectro-Photometer K-2501 .............................................................. 29<br />

WellChrom Filter-Photometer K-2001 ................................................................... 30<br />

WellChrom Spectro-Photometers K-2001, K-2501, K-2600<br />

with fiber optics ................................................................................................... 31<br />

Flow Cells, <strong>Accessories</strong>, and Spare Parts ............................................................... 32<br />

Flow Cells, Spare Parts, <strong>Accessories</strong> for Photometric Detectors ............................. 34<br />

WellChrom Differential Refractometers K-2301 and K-2401 ................................. 35<br />

Fluorescence <strong>HPLC</strong> Monitor RF-10 AXL ................................................................ 36<br />

Conductivity Detector for Ion Chromatography ................................................... 37<br />

Highly Sensitive Amperometric Detector for Clinical Diagnostics .......................... 38<br />

Light Scattering Detector ELSD 2000 ................................................................... 39<br />

3


Table of Contents<br />

<strong>HPLC</strong>-Systems, <strong>Instruments</strong>, Software, <strong>Accessories</strong>, and Spare Parts<br />

Page<br />

<strong>HPLC</strong> Columns<br />

and Electric Valve Drives WellChrom Electric Valve Drives K-6 and K-16 ...................................................... 40<br />

Injection and Switching Valves for K-6 and K-16 .................................................. 41<br />

4<br />

Automated <strong>HPLC</strong> Injection Systems Autosampler WellChrom Basic Marathon K-3800 ................................................. 42<br />

Autosampler TRIATHLON ..................................................................................... 43<br />

Autosampler ENDURANCE ................................................................................... 44<br />

Autosampler MIDAS ............................................................................................. 44<br />

Fraction Collectors Fraction Collector Retreiver 500 ........................................................................... 45<br />

Fraction Collector Foxy Jr. .................................................................................... 45<br />

Fraction Collector B-684 ...................................................................................... 45<br />

Online Degasser WellChrom Online Degasser K-5002 .................................................................... 46<br />

WellChrom Online Degasser K-5004 .................................................................... 46<br />

WellChrom Online Degasser K-5020 .................................................................... 46<br />

<strong>HPLC</strong> Mixing Chambers Dynamic Mixing Chamber, analytical version ....................................................... 47<br />

Dynamic Mixing Chamber, preparative version .................................................... 47<br />

Thermostats and Flowmeter Flowmeter ............................................................................................................ 48<br />

Column Box ......................................................................................................... 48<br />

Column Thermostat Jetstream .............................................................................. 48<br />

<strong>HPLC</strong> <strong>Accessories</strong> <strong>HPLC</strong> Standard Accessory Kit ............................................................................... 49<br />

Start-Up Kit, analytical .......................................................................................... 50<br />

Start-Up Kit, biocompatible .................................................................................. 50<br />

Start-Up Kit, preparative ....................................................................................... 51<br />

Filters for Sample Preparation ............................................................................... 51<br />

Sample Loops, analytical ...................................................................................... 52<br />

Sample Loops, preparative ................................................................................... 52<br />

Injection Syringes ................................................................................................. 52<br />

Capillaries, Stainless Steel ..................................................................................... 53<br />

Capillaries, PEEK ................................................................................................... 53<br />

Tubings, Tefzel ..................................................................................................... 54<br />

Tubings, PTFE ....................................................................................................... 54<br />

Tube Cutter, Ferrules, and Sealing Rings ............................................................... 54<br />

T and Cross Connectors, Stainless Steel, and Polymer .......................................... 55<br />

Bushings and Blind Fittings (Caps) ....................................................................... 56<br />

DYNASEAL Connection System ............................................................................ 56<br />

Column Inlet Filters .............................................................................................. 58<br />

Syringe Filtration Units ......................................................................................... 58<br />

Terms of Delivery Terms of Delivery, address, bank information ....................................................... 59<br />

Conditions of Sale Conditions of Sale ................................................................................................ 60


<strong>HPLC</strong> System Solutions<br />

System Proposal »Helios«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A41301 WellChrom <strong>HPLC</strong> Pump K-1001, includes 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A4012 WellChrom Solvent Organizer K-1500, stainless steel 1<br />

A0285 Dynamic Mixing Chamber 1<br />

A2015 WellChrom Online Degasser K-5004, 4 channels 1<br />

A4070 WellChrom Fast Scanning Spectro-Photometer K-2600 1<br />

A4061 Analytical Flow Cell, 10 mm 1<br />

A0759 WellChrom Autosampler Basic Marathon K-3800 1<br />

A1456 ChromGate ® Chromatography Data Acquisition and Management 1<br />

A1459 Scan Option for Spectro-Photometer K-2600 1<br />

A0910 Start-Up Kit, analytical 1<br />

I6Y535 VERTEX Column, Eurospher 100 C18, 5 µm, 250 x 4 mm<br />

with an integrated precolumn 1<br />

Description<br />

Premium <strong>HPLC</strong> analysis with<br />

maximum flexibility<br />

This system will satisfy your needs in<br />

all aspects of laboratory work. Whether<br />

it be the acquisition of spectras or the<br />

evaluation of peak purity, complete and<br />

GLP compliant software control is what<br />

you are looking for.<br />

This system raises the bar in terms of<br />

performance and flexibility.<br />

We lowered the bar, however, when it<br />

came to the price!<br />

5


<strong>HPLC</strong> System Solutions<br />

6<br />

Description<br />

Isocratic stand-alone system<br />

Complete isocratic stand-alone system<br />

with online degasser, software, columns,<br />

and accessories. Simply set it up,<br />

calibrate, and measure!<br />

The system is reliable and qualified for<br />

use in quality control and<br />

routine analysis.<br />

System Proposal »Asteris«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A42401 WellChrom <strong>HPLC</strong> Pump K-501 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A4160 WellChrom Filter-Photometer K-2001 1<br />

A4061 Analytical Flow Cell, 10 mm 1<br />

A1357 6-Port/3-Channel Injection Valve, 1/16”, manually driven 1<br />

A4018 Universal Mounting Bracket 1<br />

A2009 WellChrom Online Degasser K-5002, 2 channels 1<br />

A1245-4 EuroChrom ® 2000 Basic Edition V2.05, <strong>HPLC</strong> software 1<br />

A0910 Start-Up Kit, analytical 1<br />

I6Y535 VERTEX Column, Eurospher 100 C18, 5 µm, 250 x 4 mm,<br />

with precolumn 1


System Proposal »Sacharis«<br />

Ordering Information for Systems with Manual Injection<br />

Order No. Article Quantity<br />

A42401 WellChrom <strong>HPLC</strong> Pump K-501 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A2110 WellChrom Differential Refractometer K-2301 1<br />

A0527 Column Thermostat, 5 – 85 °C, with an integrated injection valve 1<br />

A2009 WellChrom Online Degasser K-5002, 2 channels 1<br />

A1245-4 EuroChrom ® 2000 Basic Edition V 2.05, <strong>HPLC</strong> software 1<br />

A0910 Start-Up Kit, analytical 1<br />

B196 VERTEX Column, Eurokat Ca, 300 x 8 mm 1<br />

Ordering Information for Systems with an Autosampler<br />

Order No. Article Quantity<br />

A42401 WellChrom <strong>HPLC</strong> Pump K-501 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A2110 WellChrom Differential Refractometer K-2301 1<br />

A0585 Column Thermostat, 5 – 85 °C, injection valve excluded 1<br />

A2009 WellChrom Online Degasser K-5002, 2 channels 1<br />

A0759 WellChrom Autosampler Basic Marathon K-3800 1<br />

A1245-4 EuroChrom ® 2000 Basic Edition V 2.05, <strong>HPLC</strong> software 1<br />

A0910 Start-Up Kit, analytical 1<br />

B196 VERTEX Column, Eurokat Ca, 300 x 8 mm 1<br />

Description<br />

Automated sugar analysis<br />

»Sacharis« can be used with or without<br />

an autosampler! With this system, you’ll<br />

have your sugar analysis under control.<br />

The proven refractive index detector<br />

and the column thermostat completes<br />

the range of this powerful system.<br />

7


<strong>HPLC</strong> System Solutions<br />

8<br />

Description<br />

Optimized for semi-preparative<br />

purification<br />

This system enables optimization and<br />

purification of substances in a semipreparative<br />

scale due to clever column<br />

switching. Prepare yourself for the<br />

majority of purification tasks in the<br />

field of semi-preparative <strong>HPLC</strong>.<br />

Its easy operation, as well as flexible<br />

adaptability guarantees the highest<br />

quality and most reliable results.<br />

System Proposal »Metis«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A42403 WellChrom <strong>HPLC</strong> Pump K-501 with semi-preparative<br />

50 ml pump head, inert with ceramic inlays 2<br />

A0285 Dynamic Mixing Chamber 1<br />

A2014 WellChrom Online Degasser K-5002, 2 channels 1<br />

A0377 WellChrom Electric Valve Drive K-6 2<br />

A1373 7-Port/1-Channel Switching Valve, 1/16”, stainless steel 2<br />

A4180 WellChrom Spectro-Photometer K-2501 1<br />

A4062 Analytical Flow Cell, 3 mm 1<br />

A0759 WellChrom Autosampler Basic Marathon K-3800 1<br />

A1170 Fraction Collector Foxy Jr. 1<br />

A1273 Diverter Valve for Fraction Collector Foxy Jr. 1<br />

A1245-4 EuroChrom ® 2000 Basic Edition V 2.05, <strong>HPLC</strong> software 1<br />

A0910 Start-Up Kit, analytical 1<br />

I6Y535 VERTEX Column, Eurospher 100 C18 5 µm, 250 x 4 mm<br />

with an integrated precolumn 1<br />

B27Y537 VERTEX Column, Eurospher 100 C18, 10 µm, 250 x 16 mm 1


System Proposal »Demeter«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A41303 WellChrom <strong>HPLC</strong> Pump K-1001 with semi-preparative<br />

50 ml pump head, inert with ceramic inlays 2<br />

A2014 WellChrom Online Degasser K-5020, 2 channels,<br />

biocompatible, preparative version 1<br />

A0275 Dynamic Mixing Chamber, Titanium 1<br />

A4018 Universal Mounting Bracket<br />

A1358 6-Port/3-Channel Injection Valve, 1/16’’, PEEK 1<br />

A1057 Sample Loop, 500 µl, 1/16’’, PEEK 1<br />

A4180 WellChrom Spectro-Photometer K-2501 1<br />

A4063 Analytical Flow Cell, 3 mm, PEEK 1<br />

A4733 EuroChrom ® for Windows, Preparative Version V 2.05 1<br />

A1170 Fraction Collector Foxy Jr. 1<br />

A1273 Diverter Valve for Fraction Collector Foxy Jr. 1<br />

A1039 Start-Up Kit, biocompatible 1<br />

Order No. Optional instead of A41303 Quantity<br />

A42403 WellChrom <strong>HPLC</strong> Pump K-501 with semi-preparative<br />

50 ml pump head, inert with ceramic inlays 2<br />

Description<br />

Versatile semi-preparative and<br />

analytical <strong>HPLC</strong><br />

This system helps the transition from<br />

analytical to semi-preparative biochromatography.<br />

Outstanding performance<br />

together with an outstanding price.<br />

Customized columns are available<br />

upon request.<br />

9


<strong>HPLC</strong> System Solutions<br />

Description<br />

Ultimate modular system for<br />

preparative <strong>HPLC</strong><br />

Everything is included even for the<br />

most precise preparative <strong>HPLC</strong> applications.<br />

<strong>KNAUER</strong> exclusively offers<br />

a complete high pressure gradient<br />

package rated up to a maximum of<br />

200 bar in perfect harmony.<br />

Its minimal use of space is outstanding!<br />

10<br />

System Proposal »Anemos«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A40201 WellChrom Preparative Pump K-1800 with<br />

preparative 250 ml pump head 2<br />

A0581 Dynamic Mixing Chamber, preparative version 1<br />

A2515 Mixing Chamber Extension Unit, 4.9 ml 1<br />

A41501 WellChrom <strong>HPLC</strong> Pump K-120 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A0377 WellChrom Electric Valve Drive K-6 1<br />

A1371 6-Port/3-Channel Switching Valve, 1/8’’, stainless steel 1<br />

A1375 7-Port/1-Channel Switching Valve, 1/8’’, stainless steel 1<br />

A1160 Preparative Sample Loop, 1/8’’, stainless steel 1<br />

A4180 WellChrom Spectro-Photometer K-2501 1<br />

A4066 Preparative Flow Cell, 1/8’’, stainless steel,<br />

variable layer thickness 0.5 mm to 2.0 mm 1<br />

A4733 EuroChrom ® for Windows, Preparative Version V 2.05, <strong>HPLC</strong> Software 1<br />

A1104 <strong>HPLC</strong> Start-Up Kit, preparative 1<br />

B31Y536 VERTEX Column, Eurospher 100 C18, 7 µm, 250 x 32 mm 1


System Proposal »Herakles«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A40201 WellChrom Preparative Pump K-1800 with<br />

250 ml pump head 1<br />

A1359 6-Port/3-Channel Injection Valve, 1/8”, stainless steel 1<br />

A1363 7-Port/1-Channel Injection Valve, 1/8”, stainless steel 1<br />

A1160 Preparative Sample Loop, 45 ml, 1/8”, stainless steel 1<br />

A4160 WellChrom Filter-Photometer K-2001 1<br />

A4066 Preparative Flow Cell, 1/8”, stainless steel,<br />

variable layer thickness 0.5 to 2.0 mm 1<br />

A0675 1-Channel Recorder 1<br />

A0790 Chart Paper for A0675 10<br />

A4018 Universal Mounting Bracket 1<br />

A1104 Start-Up Kit, preparative 1<br />

B32Y537 VERTEX Column, Eurospher 100 C18, 10 µm, 120 x 32 mm 1<br />

Description<br />

Compact high-performance<br />

preparative system<br />

Achieve pure substances for monitoring,<br />

determination of the chemical<br />

structure, or simply as an end product.<br />

This compact and powerful system can<br />

be placed just about anywhere! Even<br />

on your shopping list!<br />

11


<strong>HPLC</strong> System Solutions<br />

Description<br />

Our exclusive explosion proof<br />

preparative system<br />

Our exclusive fiber optics enable the<br />

separation of the measuring cell from<br />

the instrument. Thus, optimal positions<br />

can be achieved for the cell due to its<br />

miniature housing for use in hazardous<br />

conditions.<br />

Hazard proof pumps are available<br />

upon request.<br />

12<br />

System Proposal »Zefiros«<br />

Ordering Information<br />

Order No. Article Quantity<br />

A40202 WellChrom Preparative Pump K-1800 with preparative<br />

1,000 ml pump head 1<br />

A1359 6-Port/3-Channel Injection Valve, 1/8”, stainless steel 1<br />

A1363 7-Port/1-Channel Injection Valve, 1/8”, stainless steel 1<br />

A1160 Preparative Sample Loop, 45 ml, 1/8”, stainless steel 1<br />

A4210 WellChrom Spectro-Photometer K-2501 with fiber optics 1<br />

A4078 Preparative Flow Cell, 1/8”, stainless steel,<br />

variable layer thickness 0.5 to 2.0 mm, with fiber optics 1<br />

A0675 1-Channel Recorder 1<br />

A0790 Chart Paper for A0675 10<br />

A4018 Universal Mounting Bracket 1<br />

A1104 Start-Up Kit, preparative 1<br />

B141Y537 VERTEX Column, Eurospher 100 C18, 10 µm , 250 x 40 mm 1


CHANCE – The smallest <strong>HPLC</strong> System in the World<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4330 CHANCE System, isocratic:<br />

WellChrom <strong>HPLC</strong> Pump K-120 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

WellChrom Fixed Wavelength Detecor K-200 1<br />

Analytical Flow Cell, 10 mm 1<br />

6-Port/3-Channel Injection Valve, 1/16’’, manually driven 1<br />

VERTEX Column, Eurospher 100 C18, 5 µm, 125 x 4 mm 1<br />

Set of accessories and spare parts 1<br />

A4440 CHANCE-Software for Windows 95/98, NT 1<br />

A4450 HPG Extension Kit:<br />

WellChrom <strong>HPLC</strong> Pump K-120 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

Static Mixing Chamber 1<br />

Set of accessories 1<br />

A4460 CHANCE System, semi-preparative:<br />

50 ml pump head, inert with ceramic inlays 1<br />

Semi-preparative flow cell, 3 mm 1<br />

Semi-preparative sample loop, 100 µl 1<br />

WellChrom Online Degasser K-5002, 2 channels 1<br />

Set of accessories 1<br />

A0676 Manometer (0 – 400 bar) with Universal Mounting Bracket for<br />

WellChrom <strong>HPLC</strong> Pump K-120 1<br />

Description<br />

This tiny new system is very practical<br />

for routine <strong>HPLC</strong> analysis with UV detection.<br />

It fits into the smallest spot in the<br />

laboratory and is very »mobile«. Even a<br />

battery can be used for energy supply.<br />

Thus, outdoor right-in-place analysis is<br />

possible. The system is suitable for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Semi-Preparative <strong>HPLC</strong><br />

The RS-232 connector enables external<br />

control of the pump and detector.<br />

Optional<br />

Powerful CHANCE-Software is for data<br />

acquisition and instrument control,<br />

quantitative peak evalution according<br />

to the methods of internal and external<br />

standard, and more sophisticated<br />

features.<br />

The CHANCE-System can be extended<br />

to a binary high pressure gradient<br />

(HPG) system, if a second WellChrom<br />

<strong>HPLC</strong> Pump K-120 and a static mixing<br />

chamber are used. Extension to a semipreparative<br />

system is also possible.<br />

Refer to page 21 for detailed information<br />

on the <strong>HPLC</strong> pump K-120.<br />

13


<strong>KNAUER</strong> Software<br />

Description<br />

ChromGate ® is a real 32-bit chromatography<br />

data system based on the<br />

newest technology from Windows 95,<br />

Windows 98, and Windows NT.<br />

ChromGate ® provides powerful and<br />

sophisticated features in one package<br />

and comes with an easy-to-use interface.<br />

The software includes creation<br />

of methods, design of custom reports,<br />

calibration functions according to<br />

proven chromatographic standard<br />

methods, data acquisition, peak processing,<br />

and running automated<br />

sample sequences.<br />

With ChromGate ® it is possible to<br />

control numerous independent chromatographic<br />

systems connected to<br />

<strong>KNAUER</strong> or third party instruments.<br />

ChromGate’s ® GLP compliant import<br />

and export functions, as well as its<br />

client/server properties, guarantee a<br />

perfect integration into your local area<br />

network or Laboratory Information<br />

Management System (LIMS).<br />

14<br />

ChromGate ® – System Control and Data Acquisition<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1456-2 ChromGate ® Data System V2.8, third release,<br />

License for 1 <strong>HPLC</strong> system 1<br />

A1457-2 Additional license for one more <strong>HPLC</strong> system 1<br />

A1458-2 Additional license to process chromatographic data on another<br />

offline computer 1<br />

A1459-2 Additional license to support <strong>KNAUER</strong>’s<br />

WellChrom Fast Scanning Spectro-Photometer K-2600 1<br />

A1460-2 Additional license to support <strong>KNAUER</strong>’s<br />

WellChrom Diode Array Detector K-2150 and K-2700 1<br />

A1461-2 Additional license to support system suitability options such as<br />

customized calculations along with a method 1<br />

A1469-2 ChromGate ® Client License 1<br />

A1470-2 ChromGate ® GPC option 1<br />

A1472 Upgrade to ChromGate ® V 2.8, third release 1<br />

A1311 Personal Computer for ChromGate ® Data System:<br />

The computer corresponds to the ChromGate ® hardware<br />

requirements. Complete functionality is guaranteed in a<br />

client/server network. 1<br />

A1312 Color Monitor, 17’’ 1<br />

A1493-2 ChromGate ® Data System V2.8, third release,<br />

Client/Server license for 1 <strong>HPLC</strong> system 1<br />

A1494-2 Additional Client/Server license for one more <strong>HPLC</strong> system 1<br />

A1495-2 Client license for Client/Server environment 1<br />

Additional Software Products<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1468 Upgrade from EuroChrom ® 2000 <strong>HPLC</strong> software to ChromGate ®<br />

Data System V 2.8, third release 1<br />

A1245-4 EuroChrom ® 2000 Basic Edition V 2.05, interface box excluded 1<br />

A4733-1 EuroChrom ® 2000 for Windows, Preparative Version V 3.01 1<br />

A1347-2 Upgrade EuroChrom ® 2000 Integration Package to V 1.65 1<br />

A13082 Interface Box 1


Online SPE and <strong>HPLC</strong><br />

UNEXAS – Online Sample Preparation<br />

Ordering Information<br />

Order No. Article Quantity<br />

A30001 UNEXAS, fully automated system for online-sample<br />

preparation in <strong>HPLC</strong> 1<br />

A0320 Autosampler TRIATHLON 1<br />

A1482 UNEXAS SPE cartridge holder 1<br />

A1483 UNEXAS SPE cartridge HySphere-Resin H 100<br />

Description<br />

UNEXAS (Universal Extraction and<br />

Sample Preparation) couples online<br />

solid phase extraction (SPE) to <strong>HPLC</strong>.<br />

UNEXAS is great for pharmaceutical<br />

chemistry, diagnostics, forensic analysis,<br />

food chemistry, and environmental<br />

analysis.<br />

UNEXAS grants an optimal sample<br />

throughput with a minimum consumption<br />

of eluent. Because this system<br />

minimizes the carry-over of samples,<br />

your results will be astonishing!<br />

The system is completely controlled<br />

by our GLP compliant <strong>HPLC</strong> software<br />

ChromGate ® which guarantees the<br />

highest degree of automation.<br />

Combine UNEXAS with the detector<br />

of your choice and you will receive a<br />

full analytical <strong>HPLC</strong> system that can<br />

process binary high pressure gradients.<br />

Control<br />

Completely controlled by ChromGate ®<br />

Power Supply<br />

115/220 V, 50/60 Hz<br />

Dimensions and Weight<br />

360 x 510 x 350 mm (W x H x D),<br />

21.0 kg<br />

Important Note<br />

For proper operation, UNEXAS requires<br />

the TRIATHLON autosampler which is<br />

excluded in the standard delivery!<br />

15


Simulated Moving Bed<br />

Chromatography (SMB)<br />

Description<br />

A System that produces up to<br />

100 kg of pure compounds per year<br />

The SMB System CSEP ® C916 is used<br />

for extracting pure substances on a<br />

semi-preparative scale. Like the »big«<br />

system, CSEP ® C912, the pilot facility<br />

enables continuous operation and<br />

high efficiency.<br />

The system operates with a thermostat<br />

and can hold up to 16 SMB columns of<br />

equal type. The patented Multi-Port<br />

Valve with 64 ports guarantees a compact<br />

design that maintains an incredibly<br />

small total dead volume.<br />

The continuous product feed is distributed<br />

across the entire surface of the stationary<br />

phase. Thus, the extraction<br />

yields maximum results.<br />

Important Note<br />

Due to individual requirements,<br />

columns are excluded from the standard<br />

delivery. We can recommend appropriate<br />

columns and packing materials<br />

according to your specific needs.<br />

Description<br />

Powerful Software for Preparative<br />

<strong>HPLC</strong> and SMB: SMB_Guide ® ,<br />

ChromSim ® , and IsothermFit ®<br />

Based on the well established algorithms<br />

of Prof. Guiochon (University of Tennessee,<br />

U.S.A.) and Prof. Dr. Seidel-Morgenstern<br />

(Max-Planck-Institute for Dynamics<br />

of Complex Technical Systems, Magdeburg,<br />

Germany), SMB and isocratic<br />

separations can be predicted and<br />

simulated on a computer.<br />

This set of powerful chromatographic<br />

software tools guarantee fast method<br />

development and perfect results.<br />

Let’s have a closer look at some of the<br />

advantages:<br />

• Estimation of eluent consumption,<br />

productivity, and product purity<br />

• Independent of vendors<br />

• No real measurements are required<br />

• Optimization for up to three compounds<br />

• Works for SMB and preparative <strong>HPLC</strong><br />

16<br />

SMB Pilot Facility CSEP ® C916<br />

Ordering Information<br />

Order No. Article Quantity<br />

A28521 SMB Pilot Facility CSEP ® C916 1<br />

Consists of:<br />

WellChrom <strong>HPLC</strong> Pump K-501 with 10 ml or 50 ml pump head,<br />

inert with ceramic inlays, stainless steel 4<br />

64-Port Multi-Function Valve, Hastelloy (stainless steel),<br />

1/16” connectors, pressure stability 80 bar, for up to<br />

16 equal SMB columns with either max. length of 300 mm<br />

or max. 20 kg of weight 1<br />

Column Thermostat (up to 80 °C) 1<br />

Rack on castors, 30 x 35 cm 1<br />

Set of capillaries, fittings, and accessories (1/16”) 1<br />

PC including pre-configured ValveChrom-Software 1<br />

Order No. Additional Software Products Quantity<br />

A2865 SMB_Guide ® for Windows<br />

Software for simulation and optimization of SMB separations 1<br />

A2866 Simulation software ChromSim ® for Windows<br />

Software for simulation of peak recycling and fraction collection 1<br />

A2867 Evaluation software IsothermFit ® for Windows<br />

Software for determining non-linear adsorption isotherms<br />

when working with high concentrations 1


SMB Production Facility CSEP ® C912<br />

Ordering Information<br />

Order No. Article Quantity<br />

A2850 SMB Production Facility CSEP ® C912 1<br />

Consists of:<br />

WellChrom Preparative Pump K-1800, 1<br />

with 100 ml, 250 ml, oder 1,000 ml pump head, stainless steel 4<br />

48-Port Multi-Function Valve, Hastelloy (stainless steel),<br />

1/8’’-connectors, 80 bar pressure stability, for up to 12 equal<br />

SMB columns with either a max. length of 1,000 mm or<br />

a max. weight of 120 kg 1<br />

Column Thermostat (up to 80 °C) 1<br />

Rack on castors 50 x 50 cm 1<br />

Set of capillaries, fittings, and accessories 1<br />

PC including pre-configured ValveChrom-Software 1<br />

Order No. Additional Software Products Quantity<br />

A2865 SMB_Guide ® for Windows<br />

Software for simulation and optimization of SMB separations 1<br />

A2866 ChromSim ® for Windows<br />

Software for simulation of peak recycling and fraction collection 1<br />

A2867 IsothermFit ® for Windows<br />

Software for determining of non-linear adsorption isotherms<br />

when working with high concentrations 1<br />

Description<br />

System for producing up to 1,000 kg<br />

of pure compounds per year!<br />

The SMB System CSEP ® C912 is known<br />

for its continous operation and high<br />

productivity. The continous delivery of<br />

feed and desorbent enables permanent<br />

extraction of two fractions at high<br />

concentrations.<br />

The thermostated system can hold up to<br />

12 SMB columns of similar type in terms<br />

of column packing, column dimensions<br />

etc. The patented Multi-Port Valve with<br />

its 48 ports is the »heart« of the system.<br />

The compact design of CSEP ® C912<br />

dramatically reduces the total dead<br />

volume compared to other available<br />

SMB concepts.<br />

The product is distributed across the<br />

entire surface of the stationary phase.<br />

Resulting in a highly efficient system.<br />

When peak recycling is practiced, one<br />

can save up to 90 % of eluent consumption!<br />

Yet this is still not sufficient;<br />

therefore, another savings of up to 80 %<br />

can be achieved with the column<br />

packing materials. You’re asking how?<br />

It’s simple. Neither is there a need for<br />

small particle sizes, nor for large plate<br />

numbers. This keeps column packing<br />

inexpensive!<br />

Software for process simulation and<br />

optimization is available.<br />

Important Note<br />

Due to individual requirements,<br />

columns are excluded from the standard<br />

delivery. We can recommend appropriate<br />

columns and packing materials<br />

according to your specific needs.<br />

17


Amino Acid Analysis<br />

Description<br />

The Amino Acid Analyzer A100<br />

(aminoSys) has been specifically<br />

developed for applying ready-to-use<br />

Ninhydrin reagent to a post-column<br />

derivatization or pre-column derivatization<br />

with OPA.<br />

The »A100« is distinguished by its<br />

capability of working with ready-to-use<br />

buffer solutions. Thus, the system<br />

analyzes 43 physiological amino acids<br />

in less than 90 minutes! At the same<br />

time, its design is as compact as its<br />

price.<br />

The Amino Acid Analyzer A100<br />

(aminoSys) processes sequences of<br />

up to 120 samples (1.5 ml vials)<br />

and uses a service free 570 nm UV<br />

detection.<br />

Delivery System<br />

Double-piston pump with an electronic<br />

residual pulsation suppressor<br />

Flow Ranges<br />

0.001 – 1.5 ml/min<br />

flow rate accuracy: < 1 % RSD<br />

(measured at 100 µl/min)<br />

Max. Operating Pressure<br />

400 bar<br />

Detection<br />

Service-free Micro-Photometer with<br />

570 nm fixed wavelength (optional<br />

440 nm), cell volume 10 µl, layer<br />

thickness 10 mm, autozero<br />

Temperature Control<br />

Peltier-element, column thermostat<br />

with adjustable temperature<br />

(20 °C – 80 °C),<br />

reactor with adjustable temperature<br />

(50 °C – 150 °C)<br />

Control<br />

Complete software control, optional<br />

control using keyboard and display<br />

18<br />

Amino Acid Analyzer A100 (aminoSys)<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0991 Amino Acid Analyzer A100 (aminoSys),<br />

complete with software 1


Pumps and <strong>Accessories</strong><br />

WellChrom <strong>HPLC</strong> Pump K-1001<br />

Ordering Information<br />

Order No. Article Quantity<br />

A41301 WellChrom <strong>HPLC</strong> Pump K-1001 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A41303 WellChrom <strong>HPLC</strong> Pump K-1001 with 50 ml pump head,<br />

inert with ceramic inlays 1<br />

A0231 Biocompatible Titanium Capillary-Kit for pump head<br />

and pressure unit for A41301 and A41303 1<br />

Refer to page 22 for more information on pump heads and accessories.<br />

Refer to page 26 for more details on the WellChrom Solvent Organizer K-1500.<br />

The <strong>HPLC</strong> pumps of the WellChrom family, in particular the K-120, K-501, and K-1001<br />

are delivered with the same mechanical drive. Thus, all pumps can be equipped with<br />

the same type of pump head. Spare parts can also be used with the K-100, K-500,<br />

and K-1000.<br />

Description<br />

Interchangeable inert pump heads for:<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Semi-preparative <strong>HPLC</strong><br />

This pump contains the logic needed<br />

for gradient operation. It can be extended<br />

without the assistence of a PC<br />

with the WellChrom Solvent Organizer<br />

K-1500 to receive a low pressure<br />

gradient system up to four solvents.<br />

Multiple pumps can be used to form a<br />

high pressure gradient with up to four<br />

solvents.<br />

Adding an electric switching valve will<br />

make a solvent recycling or fraction<br />

collection feature available.<br />

Delivery System<br />

Double-piston pump with an electronic<br />

residual pulsation suppressor<br />

Flow Ranges<br />

10ml pump head: 0.001–9.999ml/min*<br />

50ml pump head: 0.001–49.99ml/min<br />

* 3 digits with software control only!<br />

Flow Rate Accuracy<br />

RSD < 0.5 % (measured at 1 ml/min)<br />

Maximum Operating Pressure<br />

10 ml pump head: 400 bar,<br />

50 ml pump head: 150 bar<br />

System Protection<br />

Soft start with adjustable Pmin and Pmax Control<br />

2 RS-232 connectors, 8 event outputs<br />

(TTL, OC, relays), remote connection<br />

(start, error, pressure)<br />

The pump can be controlled with<br />

ChromGate ® software<br />

Analog Flow Rate Control<br />

0–10V<br />

Display<br />

2 x 24 characters<br />

Dimensions and Weight<br />

160 x 185 x 340 mm (W x H x D),<br />

5.2 kg<br />

19


Pumps and <strong>Accessories</strong><br />

Description<br />

Interchangeable inert pump heads for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Semi-preparative <strong>HPLC</strong><br />

Isocratic <strong>HPLC</strong> pump for one solvent<br />

composition. A high pressure gradient<br />

system with up to four solvents can be<br />

formed when using multiple pumps.<br />

Delivery System<br />

Double-piston pump with main and<br />

auxiliary piston<br />

Flow Ranges<br />

10ml pump head: 0.001–9.999ml/min*<br />

50ml pump head: 0.001–49.99ml/min<br />

* 3 digits with software control only!<br />

Maximum Operating Pressure<br />

10 ml pump head: 400 bar/150 bar<br />

(stainless steel or ceramic/PEEK)<br />

50 ml pump head: 150 bar<br />

System Protection<br />

Soft start with adjustable Pmin and Pmax Control<br />

RS-232 connector, remote connection<br />

(start, stop, flow)<br />

The pump can be controlled by<br />

EuroChrom ® 2000 V 1.65 or higher<br />

Display<br />

2 x 16 characters<br />

Dimensions and Weight<br />

105 x 186 x 340 mm (W x H x D),<br />

3.4 kg<br />

20<br />

WellChrom <strong>HPLC</strong> Pump K-501<br />

Ordering Information<br />

Order No. Article Quantity<br />

A42401 WellChrom <strong>HPLC</strong> Pump K-501 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A42403 WellChrom <strong>HPLC</strong> Pump K-501 with 50 ml pump head,<br />

inert with ceramic inlays 1<br />

A0248 Biocompatible Titanium Capillary-Kit for pump head<br />

and pressure unit for A42401 and A42403 1<br />

Refer to page 22 for more information on pump heads and accessories.<br />

The <strong>HPLC</strong> pumps of the WellChrom family, in particular the K-120, K-501, and K-1001<br />

are delivered with the same mechanical drive. Thus, all pumps can be equipped with<br />

the same type of pump head. Spare parts can also be used with the K-100, K-500,<br />

and K-1000.


WellChrom <strong>HPLC</strong> Pump K-120<br />

Ordering Information<br />

Order No. Article Quantity<br />

A41501 WellChrom <strong>HPLC</strong> Pump K-120 with 10 ml pump head,<br />

inert with ceramic inlays 1<br />

A41503 WellChrom <strong>HPLC</strong> Pump K-120 with 50 ml pump head,<br />

inert with ceramic inlays 1<br />

A0249 Biocompatible Titanium Capillary-Kit for pump head<br />

and pressure unit for A41501 and A41503 1<br />

Refer to page 22 for more information on pump heads and accessories.<br />

The <strong>HPLC</strong> pumps of the WellChrom family, in particular the K-120, K-501, and K-1001<br />

are delivered with the same mechanical drive. Thus, all pumps can be equipped with<br />

the same type of pump head. Spare parts can also be used with the K-100, K-500,<br />

and K-1000.<br />

Description<br />

The smallest pump in the world!<br />

Interchangeable inert pump heads for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Semi-preparative <strong>HPLC</strong><br />

Isocratic pump to promote a solvent<br />

composition. Up to four pumps can be<br />

used to receive a high pressure gradient<br />

system. Although no pressure indicator<br />

is included, an automatic pressure overflow<br />

control will stop the pump if 400 bar<br />

have been exceeded. A manometer is<br />

available upon request.<br />

This model is suitable as a dosage pump<br />

in preparative <strong>HPLC</strong> as well as for<br />

reagent feed in post-column derivatizations.<br />

Delivery System<br />

Double-piston pump with main and<br />

auxiliary piston<br />

Flow Ranges<br />

10 ml pump head: 0.001–9.999ml/min*<br />

50 m pump head:0.001–49.99ml/min<br />

* 3 digits with software control only!<br />

Flow Rate Accuracy<br />

≤ 0.5 % RSD (measured at 1 ml/min)<br />

Maximum Operating Pressure<br />

10 ml pump head: 400 bar<br />

50 ml pump head: 150 bar<br />

Control<br />

RS-232 connector, remote connection<br />

(start, stop)<br />

The pump can be controlled by<br />

EuroChrom ® 2000 V 1.65 and higher<br />

Display<br />

2 characters<br />

Dimensions and Weight<br />

105 x 100 x 185 mm (W x H x D),<br />

1.5 kg<br />

21


Pumps and <strong>Accessories</strong><br />

22<br />

<strong>Accessories</strong> and Spare Parts for WellChrom <strong>HPLC</strong> Pumps<br />

K-120, K-501, K-1001, K-100, K-500, and K-1000<br />

Order No. Article Quantity<br />

A4033 10 ml pump head, inert with ceramic inlays 1<br />

A1514 Set of gaskets, for 1/8” piston rod for A4033:<br />

1 seal high pressure side, 1 seal low pressure side, 1 O-ring 1<br />

A1515 Set of gaskets, for 1/8” piston rod preferably for aqueous solutions<br />

for A4033: 1 seal high pressure side, 1 seal low pressure side, 1 O-ring 1<br />

A1414 Set of gaskets, for 1/8” piston rod for A4033:<br />

2 seals high pressure side, 2 O-rings (can also be used on the low<br />

pressure side if the pump head is made of stainless steel or PEEK) 1<br />

A1410 Piston rod, 1/8”, for A4033 1<br />

Order No. Article Quantity<br />

A4034 50 ml pump head, inert with ceramic inlays 1<br />

A0981 Set of gaskets, for 1/4” piston rod for A4034:<br />

1 seal high pressure side, 1 seal low pressure side, 1 O-ring 1<br />

A0982 Set of gaskets, for 1/4” piston rod preferably for aqueous solutions,<br />

for A4034: 1 seal high pressure side, 1 seal low pressure side, 1 O-ring 1<br />

A0768 Set of gaskets, for 1/4” piston rod for A4034:<br />

2 seals high pressure side, 2 O-rings 1<br />

A1411 Piston rod, 1/4”, for A4034 1<br />

Order No. Article Quantity<br />

A2035 Cooling and heating device, for A4033 and A4034 1<br />

A1409 Pressure release valve, for A4033 and A4034 1<br />

A0863 Set of gaskets for check valve A0684, PEEK 1<br />

A0684 Check valve unit 1<br />

A0732 PTFE tubing, 1/8’’ x 1,5 mm, 3 m 1<br />

A0895 RS-232 cable to connect to a PC’s serial interface 1<br />

A1149 PTFE solvent filter, tubing included 1<br />

A1087 Bushing and seal, 1/8”, for pump head inlet 1<br />

A1476 Repair-Kit for A4033 includes: 1<br />

2 x A1410, 2 x A0684, 2 x A1514, 2 x A0863<br />

A1477 Repair-Kit for A4034 includes: 1<br />

2 x A1411, 2 x A0684, 2 x A0981, 2 x A0863


WellChrom Preparative <strong>HPLC</strong> Pump K-1800<br />

Ordering Information<br />

Order No. Article Quantity<br />

A40209 WellChrom Preparative <strong>HPLC</strong> Pump K-1800 with<br />

100 ml pump head, stainless steel 1<br />

A40201 WellChrom Preparative <strong>HPLC</strong> Pump K-1800 with<br />

250 ml pump head, stainless steel 1<br />

A40205 WellChrom Preparative <strong>HPLC</strong> Pump K-1800 with<br />

500 ml pump head, stainless steel<br />

A40202 WellChrom Preparative <strong>HPLC</strong> Pump K-1800 with<br />

1,000 ml pump head, stainless steel 1<br />

A4099 Valves for low pressure gradient for K-1800, stainless steel 1<br />

Refer to page 25 for more information on preparative pump heads and accessories.<br />

Description<br />

The »K-1800« is a flexible <strong>HPLC</strong> pump<br />

with an interchangeable pump head.<br />

This pump ensures constant flow rates<br />

for both analytical and preparative<br />

<strong>HPLC</strong> and for SMB purposes.<br />

Up to four pumps can be used to receive<br />

a high pressure gradient system.<br />

This pump demonstrates its reliable and<br />

reproducible gradient profiles, even<br />

with the optional low pressure gradient<br />

valve module.<br />

Delivery System<br />

Double-piston pump with Al2O3-pistons with electronic residual pulsation suppressor<br />

Flow Ranges<br />

100 ml pump head: 0.1 – 99.9 ml/min<br />

250 ml pump head: 0.1 – 249.9 ml/min<br />

1,000ml pump head: 0.1–999.9 ml/min<br />

Flow Rate Accuracy<br />

± 2 %, measured at 2 – 50 % of the<br />

flow range using methanol/water<br />

80 : 20 (v/v), RSD < 0.1 %<br />

Maximum Operating Pressure<br />

100 ml pump head: 400 bar<br />

250 ml pump head: 200 bar<br />

1,000 ml pump head: 50 bar<br />

System Protection<br />

Soft start with adjustable Pmin and Pmax Control<br />

2 RS-232 connectors, 8 event outputs<br />

(TTL, OC, relays), remote connection<br />

(start, error)<br />

The pump can be controlled with<br />

EuroChrom ® for Windows, Preparative<br />

Version V 1.65 and higher<br />

Display<br />

2 x 24 characters<br />

Power Supply<br />

115/230 V, 47 – 63 Hz, 450 W<br />

Dimensions and Weight<br />

220 x 185 x 340 mm (W x H x D),<br />

10.0 kg<br />

23


Pumps and <strong>Accessories</strong><br />

Description<br />

The »K-1900« is a pneumatic driven<br />

pump without electronics. Thus, the<br />

pump is suitable for work in hazardous<br />

environments. Due to its strong drive,<br />

it can reach flow rates of up to 2,000<br />

ml/min. This pump is ideal for column<br />

packing of microbore, analytical, and<br />

preparative columns that are under<br />

conditions up to 1,000 bar. The constant<br />

flow rate of the pump enables it<br />

to be used in process and production<br />

chemistry. Combined with the cooling<br />

option available, transportation of<br />

supercritical fluids is made possible.<br />

Due to its strong and powerful drive,<br />

the »K-1900« reaches much higher flow<br />

rates using the same pump heads as<br />

say, the WellChrom Preparative Pump<br />

K-1800. A long life and low service requirements<br />

are of course »included«.<br />

Operating Parameter<br />

100 ml pump head:<br />

Inlet air pressure: 4.2 bar<br />

Max. flow rate: 300 ml/min<br />

Max. solvent pressure: 1,000 bar<br />

Piston diameter: 6.35 mm<br />

Piston stroke volume/cycle: 0.6 ml<br />

Piston transformation ratio: 1 : 250<br />

250 ml pump head:<br />

Inlet air pressure: 7.0 bar<br />

Max. flow rate: 500 ml/min<br />

Max. solvent pressure: 670 bar<br />

Piston diameter: 9.525 mm<br />

Piston stroke volume/cycle: 1.35 ml<br />

Piston transformation ratio: 1 : 96<br />

1,000 ml pump head:<br />

Inlet air pressure: 7.0 bar<br />

Max. flow rate: 2,000 ml/min<br />

Max. solvent pressure: 160 bar<br />

Piston diameter: 19.05 mm<br />

Piston stroke volume/cycle: 5.4 ml<br />

Piston transformation ratio: 1 : 23<br />

Piston Stroke<br />

For all pump heads 9.5 mm<br />

Display<br />

Inlet air pressure, solvent pressure<br />

Dimensions and Weight<br />

220 x 185 x 340 mm (W x H x D),<br />

10.2 kg<br />

24<br />

WellChrom Pneumatic <strong>HPLC</strong> Pump K-1900<br />

Ordering Information<br />

Order No. Article Quantity<br />

A40289 WellChrom Pneumatic <strong>HPLC</strong> Pump K-1900 with<br />

100ml pump head, stainless steel 1<br />

A40281 WellChrom Pneumatic <strong>HPLC</strong> Pump K-1900 with<br />

250ml pump head, stainless steel 1<br />

A40285 WellChrom Pneumatic <strong>HPLC</strong> Pump K-1900 with<br />

500ml pump head, stainless steel 1<br />

A40282 WellChrom Pneumatic <strong>HPLC</strong> Pump K-1900 with<br />

1,000ml pump head, stainless steel 1<br />

Refer to page 25 for more information on pump heads and accessories.


Preparative Pump Heads and <strong>Accessories</strong><br />

Ordering Information<br />

Order No. Pump Heads with <strong>Accessories</strong> Quantity<br />

A4029 100 ml pump head, stainless steel 1<br />

A4021 250 ml pump head, stainless steel 1<br />

A4038 500 ml pump head, stainless steel 1<br />

A4022 1,000 ml pump head, stainless steel 1<br />

A4036 8-fold pump head, stainless steel<br />

A2034 Cooling device for pump heads A4029, A4021, A4022<br />

A4099 Ternary low pressure gradient, preparative 1<br />

Order No. <strong>Accessories</strong> and Spare Parts for 100 ml Pump Heads Quantity<br />

A0684 Check valve unit 1<br />

A0747 Piston rod, 1/4” 1<br />

A0746 2 piston seals and 1 O-ring 1<br />

A2003 Hydraulic connection set (10 tube fitting screws, 10 tube ferrules) 1<br />

A1121 Device for peak recycling and SMB applications,<br />

2 inlet valve housings, 1 T-connector, 1 fitting, 1 screw, 1 ferrule,<br />

1 left-hand and 1 right-hand connection tubing 1<br />

Order No. <strong>Accessories</strong> and Spare Parts for 250 ml Pump Heads Quantity<br />

A1080 Check valve unit 1<br />

A1017 Piston rod, 3/8” 1<br />

A1046 2 piston seals and 1 O-ring 1<br />

A2003 Set of hydraulic connection (10 tube fitting screws, 10 tube ferrules) 1<br />

A1117 Device for peak recycling and SMB applications,<br />

2 inlet valve housings, 1 T-connector, 1 fitting, 1 screw, 1 ferrule,<br />

1 left-hand and 1 right-hand connection tubing 1<br />

Order No. <strong>Accessories</strong> and Spare Parts for 500 ml Pump Heads Quantity<br />

A1080 Check valve unit 1<br />

A1478 Piston rod, 9/16’’ 1<br />

A1479 2 piston seals and 1 O-ring 1<br />

Order No. <strong>Accessories</strong> and Spare Parts for 1,000 ml pump heads Quantity<br />

A1080 Check valve unit 1<br />

A1015 Piston rod, 3/4” 1<br />

A1077 2 piston seals and 1 O-ring 1<br />

Important Note<br />

Cooling and heating options for pump<br />

heads as well as connections to thermostats<br />

are available upon request.<br />

25


Pumps and <strong>Accessories</strong><br />

Description<br />

<strong>KNAUER</strong>’s Solvent Organizer replenishes<br />

the WellChrom <strong>HPLC</strong> Pump K-1001 to<br />

a low pressure gradient system that can<br />

process up to four solvents. The device<br />

is controlled by the pump and can be<br />

used with a maximum flow rate of 50<br />

ml/min. Due to inert pump heads combined<br />

with both a static mixing chamber<br />

and a PEEK valve unit, biocompatibility<br />

is guaranteed.<br />

Solvents<br />

Maximum 4<br />

Max Flow Rate per Channel<br />

50 ml/min<br />

Mixing Chamber Volume<br />

0.6 ml<br />

Control<br />

Controlled by WellChrom <strong>HPLC</strong> Pump<br />

K-1001<br />

Dimensions<br />

Container for bottles:<br />

210 x 40 x 300 mm (W x H x D)<br />

Container for tools:<br />

210x20x45mm (WxHxD)<br />

Overall dimensions:<br />

235 x 103 x 390 mm (W x H x D)<br />

Weight<br />

3.6 kg, 2.9 kg (PEEK)<br />

Important Note<br />

If the WellChrom Solvent Organizer<br />

K-1500 is operated with a static mixing<br />

chamber the flow rate should not<br />

exceed 1 ml/min.<br />

26<br />

WellChrom Solvent Organizer K-1500<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4012 WellChrom Solvent Organizer K-1500 for low pressure<br />

gradient systems, stainless steel 1<br />

A4013 WellChrom Solvent Organizer K-1500, PEEK 1<br />

A4016 Solvent Box without low pressure gradient valve unit,<br />

stainless steel 1


Detectors and <strong>Accessories</strong><br />

WellChrom Diode Array Detector K-2700<br />

Ordering Information<br />

Order No. Article Quantity<br />

A41121 WellChrom Diode Array Detector K-2700 1<br />

Consists of:<br />

A4112 DAD Module K-2700 1<br />

A4111 Deuterium Lamp Module K-2701 1<br />

A4098 Flow Cell, 10 mm, 1/16” 1<br />

Fiber Optics and <strong>Accessories</strong> 1<br />

A4113 Tungsten-Halogen Lamp 1<br />

Refer to page 32 and 33 for more information on flow cells and accessories.<br />

Description<br />

The WellChrom Diode Array Detector<br />

K-2700 gathers chromatographic data<br />

three dimensionally by measuring adsorption<br />

both as a function of retention<br />

time and wavelength. Thus, the optimal<br />

detection wavelength can be determined<br />

for each compound leading to<br />

the »best chromatogram«.<br />

The Diode Array Detector enables the<br />

use of spectra libraries for determining<br />

peak purity.<br />

Simultaneous measurement of chromatograms<br />

can be performed with a high<br />

sensitivity.<br />

Diode array and lamp modules are<br />

connected via fiber optics.<br />

Diode Array<br />

1024 diodes in a ceramic chassis<br />

Wavelength Ranges<br />

190 – 740 nm (Deuterium)<br />

400 – 1020 nm (Tungsten-Halogen)<br />

Light Source<br />

Deuterium lamp or<br />

Tungsten-Halogen lamp<br />

Spectral Resolution<br />

2 nm (0.8 nm pixel distance)<br />

Wavelength Accuracy<br />

± 0.1 nm<br />

Wavelength Reproducibility<br />

± 0.07 nm<br />

Noise<br />

5x10-5AU, typical value: 3 – 10 x 10-5 AU<br />

Sensitivity<br />

1x10-4AU Drift<br />

< 1 x 10-3 AU/h<br />

Control<br />

3D graphic interface and spectra library<br />

functions are included in EuroChrom ®<br />

2000 Basic Edition V 2.05 and Chrom-<br />

Gate ® software<br />

Recommended: Pentium PC with a minimum<br />

of 10 GB hard disk, 128 MB RAM,<br />

and 1 free PCI-slot for a RS-422 interface<br />

card per module<br />

Dimensions and Weight<br />

106 x 185 x 340 (W x H x D),<br />

6.7 kg for each module<br />

27


Detectors and <strong>Accessories</strong><br />

Description<br />

This spectro-photometer operates with<br />

interchangeable flow cells for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Preparative <strong>HPLC</strong><br />

Multiple chromatograms can be simultaneously<br />

acquired at different wavelengths.<br />

In the »stand-alone« mode the<br />

detector offers two adjustable wavelengths<br />

per run, while four wavelengths<br />

are available if externally controlled.<br />

In the »on-flow« mode UV-spectras can<br />

be acquired.<br />

The detector provides GLP functions<br />

such as: detailed reports, displaying the<br />

total hours of lamp operation, total<br />

number of lamp ignitions, and more.<br />

Wavelength Ranges<br />

190 – 740 nm (Deuterium)<br />

Edge filter (2nd order), 370 nm<br />

Light Source<br />

Deuterium lamp<br />

Optional Tungsten-Halogen lamp<br />

Band Width / Wavelength Accuracy<br />

∆λ ≤ 8 nm / ± 1nm<br />

Drift<br />

< 1 x 10-4 AU/h at 240 nm, t = 1s<br />

Noise<br />

< 1 x 10-5 AU at 254 nm, t = 1s<br />

With fiber optics:<br />

< 8 x 10-5 AU at 254 nm, t = 1s<br />

Sensitivity<br />

< 2 x 10-5 AU at 254 nm, t = 1s<br />

Scan Speed<br />

Complete wavelength range on-flow<br />

with ca. 100 nm/s<br />

Control<br />

2 RS-232 connectors, analog input,<br />

analog outputs (TTL, OC, relays), signal<br />

output for fraction collector, controlled<br />

by EuroChrom ® 2000 Basic Edition<br />

V 1.65 or higher and ChromGate ®<br />

Integrator Output<br />

± 0.1 V / ± 1 V / ± 10 V<br />

Dimensions and Weight<br />

160 x 185 x 340 mm (W x H x D),<br />

5.5 kg<br />

28<br />

WellChrom Fast Scanning Spectro-Photometer K-2600<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4070 WellChrom Fast Scanning Spectro-Photometer K-2600,<br />

without flow cell, accessories included 1<br />

Refer to page 32 and 33 for additional accessories and spare parts!


WellChrom Spectro-Photometer K-2501<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4180 WellChrom Spectro-Photometer K-2501,<br />

without flow cell, accessories included 1<br />

Refer to page 32 and 33 for additional accessories and spare parts!<br />

Description<br />

The WellChrom Spectro-Photometer<br />

K-2501 operates with interchangeable<br />

flow cells for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Preparative <strong>HPLC</strong><br />

For each run, a particular wavelength<br />

can be set between 200nm and 740nm.<br />

The wavelength can be changed during<br />

the measurement. Thus, different wavelengths<br />

for different runs can be easily<br />

programmed. When switched into the<br />

stop-flow mode, the detector is capable<br />

of acquiring UV-spectras.<br />

Wavelength Ranges<br />

190 – 740 nm (Deuterium)<br />

Edge filter (2nd order), 370 nm<br />

Light Source<br />

Deuterium lamp<br />

Optional Tungsten-Halogen lamp<br />

Band Width / Wavelength Accuracy<br />

∆λ ≤ 8 nm / ± 2 nm<br />

Drift<br />

< 15 x 10-5 AU/h bei 254 nm, t = 1s<br />

Noise<br />

< 1 x 10-5 AU at 254 nm, t = 1s<br />

Sensitivity<br />

2x10-5AU at 254 nm, t = 1s<br />

Scan Speed<br />

Complete wavelength range on-flow<br />

with ≈ 100 nm/s<br />

Digital Output<br />

RS-232 connector<br />

Analog Output<br />

± 1V<br />

GLP Functions<br />

Detailed reports, total lamp operation<br />

time, number of lamp ignitions<br />

Dimensions and Weight<br />

106 x 185 x 340 mm (W x H x D),<br />

4.0 kg<br />

29


Detectors and <strong>Accessories</strong><br />

Description<br />

This filter-photometer operates with<br />

interchangeable flow cells for<br />

• Micro <strong>HPLC</strong><br />

• Analytical <strong>HPLC</strong><br />

• Preparative <strong>HPLC</strong><br />

Depending on the filter used, chromatograms<br />

can be acquired at a fixed<br />

wavelength of 200nm, 220nm, 254nm,<br />

or 280 nm. Further wavelength filters<br />

are available upon request!<br />

An automatic change of the filter in<br />

use can be programmed.<br />

Wavelength<br />

Up to 6 standard 1/2” filters are possible.<br />

The standard delivery contains<br />

4 filters: 200 nm, 220 nm, 254 nm,<br />

and 280 nm.<br />

Light Source<br />

Deuterium lamp<br />

Optional Tungsten-Halogen lamp<br />

Band Width<br />

∆λ ≤ 20 nm<br />

Drift<br />

< 15 x 10-5 AU/h at 254 nm, t = 1s<br />

Noise<br />

< 1 x 10-5 AU at 254 nm, t = 1s<br />

Sensitivity<br />

2x10-5AU at 254 nm, t = 1s<br />

Digital Output<br />

RS-232 connector<br />

Analog Output<br />

±1V<br />

GLP Functions<br />

Detailed reports, total lamp operation<br />

time, number of lamp ignitions<br />

Dimensions and Weight<br />

106 x 185 x 340 mm (W x H x D),<br />

4.0 kg<br />

30<br />

WellChrom Filter-Photometer K-2001<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4160 WellChrom Filter-Photometer K-2001,<br />

flow cell excluded, accessories included 1<br />

Refer to page 32 and 33 for additional accessories and spare parts!


WellChrom Spectro-Photometers K-2001, K-2501, and K-2600<br />

with Fiber Optics<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4200 WellChrom Filter-Photometer K-2001,<br />

with fiber optics, flow cell excluded, accessories included 1<br />

A4210 WellChrom Spectro-Photometer K-2501,<br />

with fiber optics, flow cell excluded, accessories included 1<br />

A4090 WellChrom Fast Scanning Spectro-Photometer K-2600,<br />

with fiber optics, flow cell excluded, accessories included 1<br />

Refer to page 32 and 33 for additional accessories and spare parts!<br />

Description<br />

The use of fiber optics enables physical<br />

separation of the flow cell from<br />

the detector hardware. Thus, spectrophotometers<br />

are ideal for use in hazardous<br />

environments or near explosive<br />

materials. The temperature of the flow<br />

cell is adjustable. All spectro-photometers<br />

in the WellChrom family can<br />

be equipped with fiber optics.<br />

31


Detectors and <strong>Accessories</strong><br />

Flow Cells, <strong>Accessories</strong>, and Spare Parts<br />

Ordering Information<br />

32<br />

Analytical Flow Cells for WellChrom K-200, K-2001, K-2501, and K2600<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max.Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4061 10 (1/16’’) 1.1 10 stainless steel* 20 300<br />

A4042 3 (1/16’’) 1 2 stainless steel 50 300<br />

A4045 3 (1/16’’) 1 2 PEEK 50 30<br />

Analytical Flow Cells for WellChrom Diode Array Detector K-2700<br />

– single fiber optical connector –<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max.Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4098 10 (1/16’’) 1.1 10 stainless steel* 20 300<br />

A4043 3 (1/16’’) 1 2 stainless steel 50 300<br />

A4046 3 (1/16’’) 1 2 PEEK 50 30<br />

Preparative Flow Cells for WellChrom K-200, K-2001, K-2501, and K2600<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max.Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4066 0.5/1.25/2 (1/8’’) stainless steel 1,000 200<br />

A4067 0.5/1.25/2 (1/8’’) PEEK 1,000 100<br />

A4068 0.5/1.25/2 (1/4’’) stainless steel 10,000 200<br />

A4069 0.5 (1/16’’) stainless steel 250 200<br />

A4095 0.5 (1/16’’) PEEK 250 100<br />

Preparative Flow Cells for WellChrom Diode Array Detector K-2700<br />

– single fiber optical connector –<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max.Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4117 0.5/1.25/2 (1/8’’) stainless steel 1,000 200<br />

A4119 0.5/1.25/2 (1/8’’) PEEK 1,000 100<br />

A4120 0.5/1.25/2 (1/4’’) stainless steel 10,000 200<br />

A4121 0.5 (1/16’’) stainless steel 250 200<br />

A4122 0.5 (1/16’’) PEEK 250 100<br />

* with heat exchanger


Flow Cells, <strong>Accessories</strong>, and Spare Parts<br />

Ordering Information<br />

Analytical Flow Cells for WellChrom K-200, K-2001, K-2501, and K2600<br />

– double fiber optical connection –<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max. Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4074 10 (1/16’’) 1.1 10 stainless steel* 20 300<br />

A4044 3 (1/16’’) 1 2 stainless steel 50 300<br />

A4047 3 (1/16’’) 1 2 PEEK 50 30<br />

A4077 3 (1/16’’) 0.7 1 PEEK 10 30<br />

A4078 0.5/1.25/2 (1/8’’) stainless steel 1,000 200<br />

A4079 0.5/1.25/2 (1/8’’) PEEK 1,000 100<br />

A4081 0.5/1.25/2 (1/4’’) stainless steel 10,000 200<br />

A4089 0.5 (1/16’’) stainless steel 250 200<br />

A4096 0.5 (1/16’’) PEEK 250 100<br />

U-Z View Micro Flow Cells for WellChrom K-200, K-2501, and K2600<br />

– fiber optics not available –<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max. Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4091 8 (1/16’’) 0.150 0.140 fused silica 0.1 500<br />

A4044 8 (1/16’’) 0.075 0.035 fused silica 0.01 500<br />

A4047 8 (1/16’’) 0.020 0.003 fused silica 0.001 500<br />

CE Cell (Capillary Electrophoresis)<br />

– fiber optics not available –<br />

Order No. Layer Thickness ID Vol. Material Flow Rate Max. Pressure<br />

mm (connection) mm µl ml/min bar<br />

A4097 1 (1/16’’) stainless steel<br />

* with heat exchanger<br />

Important Note<br />

Cell volumes for adjustable cells are:<br />

0.50 mm � 1.7 µl<br />

1.25 mm � 4.3 µl<br />

2.00 mm � 6.8 µl<br />

33


Detectors and <strong>Accessories</strong><br />

Important Note<br />

Each repair kit (A1131, A1475, and<br />

A1132) for flow cells consist of 2 seals,<br />

2 gasket holders, and 2 lenses.<br />

34<br />

Flow Cells, Spare Parts, <strong>Accessories</strong> for Photometric Detectors<br />

Ordering Information<br />

Order No. Article Quantity<br />

A4071-1 Deuterium lamp (35 W) 1<br />

A4072 Tungsten-Halogen lamp 1<br />

A4073 Tungsten-Halogen lamp with base (required for first time installation) 1<br />

A4142 Mercury vapor lamp with lamp board for<br />

WellChrom Fixed Wavelength Detector K-200 1<br />

A4098 Analytical flow cell, 10 mm, 10 µl, stainless steel,<br />

with connector for fiber optics 1<br />

A0911 Fiber optical connector, length 400 mm 1<br />

A0742 Fiber optical connector, length 750 mm 1<br />

A0740 Fiber optical connectors, length 750 mm 2<br />

A0743 Fiber optical connectors with individual length upon request 1<br />

A0857 Extension-Kit for coupling two fiber optical connectors<br />

to separate the cell from the instrument hardware 1<br />

A4126 Test cell, holmium oxide filter for photometers 1<br />

A4127 Test cell, holmium oxide filter for<br />

WellChrom Diode Array Detector K-2700 1<br />

A4128 Test cell, holmium oxide filter for detectors using fiber optics 1<br />

A1447 1 lens, 1 seal for analytical flow cells 1<br />

A1448 1 lens, 1 seal for preparative flow cells 1<br />

A1449 1 lens, 1 seal for flow cells using fiber optics 1<br />

A1131 Repair-Kit for analytical flow cells, 10 mm 1<br />

A1475 Repair-Kit for analytical flow cells, 3 mm 1<br />

A1132 Repair-Kit for preparative flow cells 1<br />

A2004 PCI interface card for WellChrom Diode Array Detector K-2700 1


WellChrom Differential Refractometers K-2301 and K-2401 Description<br />

Ordering Information<br />

Order No. Article Quantity<br />

A2110 WellChrom Differential Refractometer K-2301, analytical,<br />

flow cell A0294 and accessories included 1<br />

A2111 WellChrom Differential Refractometer K-2401, preparative,<br />

flow cell A0287 and accessories included 1<br />

Order No. <strong>Accessories</strong> and Spare Parts Quantity<br />

A0294 Flow cell, 45 °, 9 µl 1<br />

A0287 Flow cell, 15 °, 12 µl, sensitivity reduced by factor 3 1<br />

A0277 Gasket for flow cell A0294 and A0287 1<br />

All WellChrom Differential Refractometers<br />

are suitable for detecting little<br />

or no UV-active compounds such as<br />

sugars or polymers. The instruments<br />

are designed for use in analytical and<br />

preparative <strong>HPLC</strong> as well as for GPC<br />

applications.<br />

WellChrom<br />

Differential Refractometer K-2301<br />

Wavelength<br />

950 ± 30 nm<br />

Range<br />

±1x10-3∆n Sensitivity<br />

< 8 x 10-8 ∆n<br />

Noise<br />

≤ 4x10-8∆n Cell Angle and Volume<br />

45 °, 9 µl<br />

Max. Flow Range<br />

5 ml/min<br />

WellChrom<br />

Differential Refractometer K-2401<br />

Wavelength<br />

950 ± 30 nm<br />

Range<br />

±2x10-3∆n Sensitivity<br />

8x10-7∆n Noise<br />

< 4 x 10-7 ∆n<br />

Cell Angle and Volume<br />

15 °, 12 µl<br />

Max. Flow Range<br />

99 ml/min<br />

Autozero<br />

Full range<br />

Analog Output<br />

±1 V<br />

Digital Output<br />

RS-232 connector<br />

Various<br />

Internal selenoid valve for purging<br />

the reference cell<br />

Dimensions and Weight<br />

106 x 185 x 340 mm (W x H x D),<br />

8.0 kg<br />

35


Detectors and <strong>Accessories</strong><br />

Description<br />

Fluorescence <strong>HPLC</strong> Monitor with high<br />

sensitivity. Thus, suitable for amino acids<br />

and other compounds showing fluorescence<br />

activity, particularly in trace analysis.<br />

Light Source<br />

Xenon lamp, 150 W<br />

Monochromator<br />

Concave, holographic grating monochromator<br />

Wavelength Range<br />

200 – 650 nm (optional 200 – 900 nm)<br />

Spectral Bandwidth<br />

15 nm, in excitation and emission state<br />

Wavelength Accuracy<br />

±2nm<br />

Wavelength Reproducibility<br />

±0.2 nm<br />

Sensitivity<br />

The signal-noise ratio for the Raman<br />

band of distilled water is 300<br />

(excitation at 350 nm, t = 1.5 s)<br />

Detection Unit<br />

Photomultiplier<br />

Cell Volume, Pressure, Materials<br />

Standard:<br />

12 µl, 2 mPa SS316, Silica, and PTFE<br />

Optional:<br />

2 µl and inert cells are available<br />

upon request<br />

Wavelength Scanning<br />

Available for exitation and emission<br />

wavelength<br />

Time Programming<br />

Up to 32 steps for wavelength settings<br />

Temperature Range<br />

4–35°C<br />

Power Supply<br />

100 – 240 V, 350 VA, 50/60 Hz<br />

Dimensions and Weight<br />

260 x 205 x 520 mm (W x H x W),<br />

17.0 kg<br />

36<br />

Fluorescence <strong>HPLC</strong> Monitor RF-10 AXL<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0815 Fluorescence <strong>HPLC</strong> Monitor RF-10 AXL 1<br />

A0753 Xenon lamp RF-10, 150 W 1


Conductivity Detector for Ion Chromatography<br />

Model 550<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1252 Conductivity Detector Model 550 1<br />

Description<br />

Suitable for determining ionic compounds.<br />

High sensitivity due to an<br />

actively tempered conductivity cell.<br />

An integrated heat exchanger preheats<br />

the mobile phase to cell temperature.<br />

The suppressor ERIS ® 1000 guarantees<br />

optimal chemical conditions for excellent<br />

results.<br />

The detector offers a wide range of<br />

linearity. Concentrations of up to<br />

500 mg/l can be directly measured<br />

enabling high reproducibility.<br />

All functions are easy to use.<br />

Measuring Range<br />

0.01 – 5,000 µS/cm in 12 steps<br />

Noise<br />

0.0004 µS/cm<br />

(double distilled water, 1ml/min, 35 °C)<br />

Baseline Drift<br />

< 0.004 µS/h<br />

(double distilled water, 1ml/min, 35 °C)<br />

Cell Volume<br />

0.5 µl<br />

Analog Output<br />

10 mV / 100 mV / 1000 mV<br />

Dimensions and Weight<br />

69 x 62 x 158 mm (W x H x D),<br />

5.9 kg<br />

37


Detectors and <strong>Accessories</strong><br />

Description<br />

The highly sensitive Amperometric<br />

Detector L-3500 determines catecholamines.<br />

The powerful electronic measuring unit<br />

and optimized cell are outstanding<br />

characteristics of this detector.<br />

Suitable for analytical and narrow-bore<br />

<strong>HPLC</strong> in clinical and pharmacological<br />

applications. Its fantastic signal-to-noise<br />

ratio enables remarkable detection<br />

limits. Because the detector performs<br />

an autozero at the beginning of each<br />

chromatogram, it can be used for<br />

routine analysis without supervision.<br />

Cell Volume<br />

1.5 µl, optional available are 0.75 µl<br />

and 2.5 µl<br />

Voltage<br />

0.000 to ± 1.999 V<br />

Input Current Range<br />

0 to ± 200 nA<br />

Measuring Range<br />

0.02 – 50 nA FS<br />

Offset Compensation<br />

± 200 nA, accuracy better<br />

than 0.05 % RSD<br />

Dimensions<br />

Electronic unit:<br />

255 x 105 x 310 mm (W x H x D)<br />

Measuring cell:<br />

120 x 155 x 110 mm (W x H x D)<br />

Weight<br />

5.5 kg (cell included)<br />

38<br />

Amperometric Detector L-3500<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1186 Amperometric Detector L-3500 with measuring cell 1


Light Scattering Detector ELSD 2000<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0925 Light Scattering Detector ELSD 2000 1<br />

Description<br />

A highly sensitive, universal, and neutral<br />

detector for the determination of compounds<br />

with little or no UV-activity such<br />

as: sugars, fats, triglycerides, phosphoric<br />

lipides, detergents, polymers, natural<br />

substances, pharmaceutical compounds<br />

or amino acids, and peptides.<br />

The molecular characteristic of light<br />

scattering is set to be directly proportional<br />

to that of the mole mass.<br />

Because of its drift-free detection as<br />

well as its independent gradient choice,<br />

the ELSD 2000 offers a great variety of<br />

applications in micro <strong>HPLC</strong>, combinatorial<br />

chemistry, and GPC.<br />

Flow Control<br />

Digital gas flow control up to 5 l/min<br />

nitrogen preferred!<br />

Pressure<br />

Maximum 80 psi<br />

Temperature<br />

Room temperature – 120 °C<br />

in steps of 1 °C<br />

Analog Output<br />

0–1V/0–10mV<br />

Display<br />

Graphical display<br />

Dimensions and Weight<br />

590 x 320 x 550 mm (W x H x D),<br />

16.0 kg<br />

39


<strong>HPLC</strong> Columns<br />

and Electric Valve Drives<br />

Description<br />

For column switching, sample enrichment<br />

on separate adsorption units,<br />

and fraction collection.<br />

The WellChrom Electric Valve Drive K-6<br />

can be used for 1 x 60 ° and 6 x 60 ° Injection<br />

and Switching Valves.<br />

The WellChrom Electric Valve Drive K-16<br />

can be used for 17-Port/1-Channel Injection<br />

and Switching Valves,<br />

16 x 22.5 °<br />

Switching Time<br />

< 150 ms<br />

Display<br />

2 characters<br />

Control<br />

RS-232 connector, external short<br />

circuit, binary code<br />

Dimensions and Weight<br />

85 x 100 x 150 mm (W x H x D),<br />

0.8 kg<br />

40<br />

WellChrom Electric Valve Drives K-6 and K-16<br />

Ordering Information<br />

WellChrom Electric Valve Drive K-6, incl. external power supply and a<br />

6-Port/3-Channel Injection and Switching Valve<br />

Order No. Maximum pressure: 300 bar Quantity<br />

A1484 Stainless steel, 1/16” 1<br />

A1485 PEEK, 1/16” 1<br />

A1486 Stainless steel, 1/8” 1<br />

A1487 PEEK, 1/8” 1<br />

7-Port/1-Channel Switching Valve<br />

A1488 Stainless steel, 1/16” 1<br />

A1489 PEEK, 1/16’’ 1<br />

A1490 Stainless steel, 1/8” 1<br />

A1491 PEEK, 1/8’’ 1<br />

WellChrom Electric Valve Drive K-16, incl. external power supply and a<br />

Order No. 17-Port/1-Channel Switching Valve Quantity<br />

A1492 Stainless steel, 1/16”, maximum pressure 50 bar 1<br />

A1492-1 Stainless steel, 1/16”, maximum pressure 100 bar 1<br />

Order No. <strong>Accessories</strong> and Spare Parts Quantity<br />

A0377 WellChrom Electric Valve Drive K-6, with external power supply,<br />

valve excluded 1<br />

A0782 WellChrom Electric Valve Drive K-16, with external power supply,<br />

valve excluded 1<br />

A0895 RS-232 cable for connection to a PC 1


Injection and Switching Valves for K-6 and K-16<br />

Ordering Information<br />

Order No. 6-Port/3-Channel Injection and Switching Valves for K-6 Quantity<br />

A1369 Stainless steel, 1/16” 1<br />

A1370 PEEK, 1/16” 1<br />

A1371 Stainless steel, 1/8” 1<br />

A1372 PEEK, 1/8”<br />

Order No. 6-Port/2-Channel Switching Valve for K-6 Quantity<br />

A1369-1 Stainless steel, 1/16” 1<br />

Order No. 7-Port/1-Channel Switching Valves for K-6 Quantity<br />

A1373 Stainless steel, 1/16” 1<br />

A1374 PEEK, 1/16” 1<br />

A1375 Stainless steel, 1/8” 1<br />

A1376 PEEK, 1/8” 1<br />

Order No. 17-Port/1-Channel Switching Valves for K-16 Quantity<br />

A1379 Stainless steel, 1/16”, pressure stable up to 50 bar 1<br />

A1379-1 Stainless steel, 1/16”, pressure stable up to 100 bar 1<br />

Manually Driven Injection and Switching Valves<br />

Ordering Information<br />

Order No. 6-Port/2-Channel Injection Valves Quantity<br />

A1365 Stainless steel, 1/16” 1<br />

A1366 PEEK, 1/16” 1<br />

Order No. 6-Port/3-Channel Injection Valves Quantity<br />

A1357 Stainless steel, 1/16” 1<br />

A1358 PEEK, 1/16” 1<br />

A1359 Stainless steel, 1/8” 1<br />

A1360 PEEK, 1/8” 1<br />

Order No. 7-Port/1-Channel Switching Valves Quantity<br />

A1361 Stainless steel, 1/16” 1<br />

A1362 PEEK, 1/16” 1<br />

A1363 Stainless steel, 1/8” 1<br />

A1364 PEEK, 1/8” 1<br />

Order No. <strong>Accessories</strong> Quantity<br />

A4018 Universal Mounting Bracket 1<br />

A0406 Universal Mounting Bracket for WellChrom <strong>HPLC</strong> Pump K-120 1<br />

Important Note<br />

Valves made out of stainless steel are<br />

pressure stable up to 300 bar.<br />

Valves made out of PEEK are pressure<br />

stable up to 200 bar.<br />

41


Automated<br />

<strong>HPLC</strong> Injection Systems<br />

Description<br />

The sample carousel of the WellChrom<br />

Basic Marathon K-3800 is accessible at<br />

anytime during operation. Due to the<br />

combination of sequence and method<br />

programming, automatic injection<br />

and online sample preparation can<br />

be easily achieved. The device can<br />

be controlled by EuroChrom ® 2000<br />

Basic Edition V 1.65 or higher or by<br />

ChromGate ® .<br />

An option for tempering the sample<br />

carousel is available upon request.<br />

Sample Capacity<br />

96 sample vials of 1.8 ml or<br />

48 sample vials of 5.0 ml<br />

Injection Method<br />

Total sample loop filling<br />

Partial sample loop filling is optional<br />

Sample Loops<br />

100 µl (default), 250 µl, 500 µl,<br />

1,000 µl<br />

Reproducibility<br />

< 0.5 % RSD<br />

Control<br />

RS-232 connector, controlled by<br />

EuroChrom ® 2000 Basic Edition V 1.65<br />

or higher or by ChromGate ®<br />

Dimensions and Weight<br />

280 x 440 x 540 mm (W x H x D),<br />

15.0 kg<br />

42<br />

Autosampler WellChrom Basic Marathon K-3800<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0759 WellChrom Basic Marathon K-3800 1<br />

A07591 WellChrom Basic Marathon K-3800 COOL, with cooling 1<br />

A07592 WellChrom Basic Marathon K-3800 PLUS,<br />

partial sample loop filling 1<br />

<strong>Accessories</strong> for WellChrom Autosampler Basic Marathon K-3800<br />

Order No. and TRIATHLON Quantity<br />

A0664 Accessory kit for WellChrom Autosampler Basic Marathon K-3800<br />

and Autosampler TRIATHLON 1<br />

A0638 Sample vials, caps, septum caps, ∅ 11 mm 1,000<br />

A0865 Pliers for opening septum caps, ∅ 11 mm 1<br />

A0864 Pliers for closing septum caps, ∅ 11 mm 1


Autosampler TRIATHLON Description<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0320 Autosampler TRIATHLON 1<br />

A03201 Autosampler TRIATHLON COOL 1<br />

A03202 Autosampler TRIATHLON, preparative version 1<br />

<strong>Accessories</strong> for WellChrom Autosampler Basic Marathon K-3800<br />

Order No. and TRIATHLON Quantity<br />

A0664 Accessory kit for WellChrom Autosampler Basic Marathon K-3800<br />

and Autosampler TRIATHLON 1<br />

A0638 Sample vials, caps, septum caps, ∅ 11 mm 1,000<br />

A0865 Pliers for opening septum caps, ∅ 11 mm 1<br />

A0864 Pliers for closing septum caps, ∅ 11 mm 1<br />

A3440 Preparative kit for autosampler consisting of<br />

10 ml autosampler syringe, 10 ml sample loop stainless steel,<br />

15 ml buffer tubing for pre-column derivatization 1<br />

The Autosampler TRIATHLON’s high<br />

injection precision as well as its micro<br />

handling are a few of the many reasons<br />

why it is suitable for routine analysis.<br />

Fast injection cycles and reliable sample<br />

preparation steps such as enrichment,<br />

dilution, and derivatization using the<br />

smallest sample volumes is possible.<br />

These are some of the outstanding<br />

characteristics of the device making it<br />

a real advantage to have in the lab.<br />

Sample Capacity<br />

96 Sample vials of 1.5 ml or<br />

72 Sample vials of 4.0 ml or<br />

32 Sample vials of 10.0 ml each<br />

Injection Method<br />

Full and partial sample loop filling,<br />

µl-injection<br />

Injection Volumes<br />

1 to 1,000 µl in steps of 1 µl<br />

Maximum Run Time<br />

10 h<br />

Reproducibility<br />

< 0.3 % RSD at full sample loop filling<br />

Sample Loops<br />

100 µl, 250 µl (default), 500 µl, 1,000 µl<br />

Control<br />

RS-232 connector, 5 signal outputs,<br />

1 signal input, works as master or slave<br />

Options<br />

Cooling unit, 4 – 40 °C<br />

Biocompatible injection valve<br />

Integrated solvent valve<br />

Power Supply<br />

115/220 V, 50/60 Hz<br />

Dimensions and Weight<br />

280 x 440 x 540 mm (W x H x D),<br />

22.0 kg<br />

43


Automated<br />

<strong>HPLC</strong> Injection Systems<br />

Description<br />

Enables high sample throughput with<br />

the smallest sample volume. The injection<br />

can be performed directly from<br />

sample vials or micro titre plates.<br />

Sample Capacity<br />

1 titre plate 128 x 86 mm plus<br />

4 sample vials of 10 ml<br />

Injection Method<br />

Full and partial sample loop filling<br />

Injection Volumes<br />

1 to 1,000 µl steps of 1 µl<br />

Sample Loops<br />

100 µl, 250 µl (default), 500 µl, 1,000 µl<br />

Options<br />

Cooling unit, 4 – 40 °C,<br />

Biocompatible injection valve<br />

Mounting bracket for additional micro<br />

titre plates with 96 positions each<br />

Power Supply<br />

115/220 V, 50/60 Hz<br />

Dimensions and Weight<br />

280 x 440 x 400 mm (W x H x D), 22.0 kg<br />

Description<br />

The Autosampler MIDAS meets both<br />

analytical and preparative requirements<br />

in your lab!<br />

Sample Capacity<br />

Sample carousel with 84 sample vials<br />

of 1.5 ml plus 3 vials of 10 ml for additional<br />

liquids<br />

Injection Method<br />

Full and partial sample loop filling<br />

Injection Volumes<br />

1 µl to 5,000 µl<br />

Sample Loops<br />

250 µl (default), 500 µl, 5,000 µl<br />

Options<br />

Cooling unit, 4 – 40 °C, biocompatible<br />

injection valve, sample carousel for<br />

1.5 ml and 10 ml vials.<br />

Power Supply<br />

115/220 V, 50/60 Hz<br />

Dimensions and Weight<br />

280 x 440 x 400 mm (W x H x D),<br />

22.0 kg<br />

44<br />

Autosampler ENDURANCE<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1500 Autosampler ENDURANCE 1<br />

A15001 Autosampler ENDURANCE COOL, with sample cooling 1<br />

Autosampler MIDAS<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1508 Autosampler MIDAS, analytical version 1<br />

A15081 Autosampler MIDAS COOL, analytical version with sample cooling 1<br />

A15082 Autosampler MIDAS COOL, preparative version 1


Fraction Collectors<br />

Fraction Collector Retreiver 500<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1183 Fraction Collector RETREIVER 500, set of racks for collectors<br />

of 12 – 13 mm ID included 1<br />

A1249 Safety valve for flow interruption 1<br />

A1250 Diverter valve for waste flow control 1<br />

Fraction Collector Foxy Jr.<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1170 Fraction Collector FOXY JR., rack included, 13 mm 1<br />

A1284 Safety valve for flow interruption 1<br />

A1273 Diverter valve for waste flow control 1<br />

Fraction Collector B-684<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1437 Fraction Collector B-684, racks excluded 1<br />

A1438 Set of racks, 120 x 50 ml collectors 1<br />

A1498 Set of racks, 120 x 20 ml collectors 1<br />

A1499 Set of racks, 48 x 250 ml collectors 1<br />

Description<br />

The Fraction Collector RETREIVER 500,<br />

applied in preparative chromatography,<br />

holds a maximum of 102 collectors (ID<br />

12 – 13 mm). Fraction collection can be<br />

performed according to time, drop<br />

number, and volume control.<br />

Valves are excluded from the standard<br />

delivery!<br />

Temperature Range 0–40°C<br />

Weight 3.0 kg<br />

Description<br />

Suitable for preparative chromatography.<br />

Holds a maximum of 144 collectors<br />

(12 – 13 mm ID). Fraction collection can<br />

be performed according to time, drop<br />

number, and volume control.<br />

Peak detection according to time<br />

window, signal level, and signal slope.<br />

Valves are excluded from the standard<br />

delivery!<br />

Temperature Range 0–40°C<br />

Weight 4.7 kg<br />

Description<br />

The »B-684« collects substances after<br />

their separation on the <strong>HPLC</strong> column<br />

according to time programs of single<br />

fractions. If controlled by EuroChrom ®<br />

2000 Basic Edition V 1.65 or higher,<br />

EuroChrom ® 2000 for Windows, Preparative<br />

Version V 2.05 or ChromGate ®<br />

system software, fraction collection<br />

can be additionally performed due<br />

to signal levels or slope.<br />

Rack Configurations<br />

4 diverter plates with 48 positions,<br />

300 x 20 ml collectors<br />

120 x 50 ml collectors<br />

48 x 250 ml collectors<br />

Fraction Collection Time<br />

1 – 999 seconds or minutes<br />

Maximum Flow Rate<br />

200 ml/min<br />

Dimension and Weight<br />

420 x 480 x 550 mm (W x H x D),<br />

16.0 kg<br />

45


WellChrom<br />

<strong>HPLC</strong> Online Degasser<br />

Description<br />

Online degassers are suitable for the<br />

removal of dissolved air and other<br />

gases from the solvent. Otherwise,<br />

dissolved gases can degass inside the<br />

pump head during the suction phase.<br />

The flow precision may be reduced if<br />

a degasser is used. On the other hand,<br />

electrochemical and refractive index<br />

detectors produce a much better<br />

measuring signal due to less noise.<br />

Degassing Method<br />

Separate vacuum chambers with microporous<br />

teflon membranes.<br />

Degassing Efficiency<br />

≈ 0.4 ppm at 10 ml/min flow rate<br />

≈ 0.2 ppm at 1 ml/min flow rate<br />

Vacuum Monitoring<br />

Continuous CPU-based monitoring,<br />

± 2 Torr, digital display, error log<br />

Specials<br />

Output for error signal, exhaust vent<br />

connector, No-Ox connections<br />

Material<br />

Teflon, polyphenylene sulfide<br />

Dimensions and Weight<br />

80 x 145 x 285 mm (W x H x D),<br />

3.0 kg<br />

Important Note<br />

Eluents do not get into contact with<br />

metal parts (K-5002 and K-5004).<br />

This option is available for K-5020<br />

upon request.<br />

46<br />

WellChrom <strong>HPLC</strong> Online Degasser<br />

K-5002, K-5004, and K-5020<br />

Ordering Information<br />

Order No. For Analytical <strong>HPLC</strong> Quantity<br />

A2009 WellChrom <strong>HPLC</strong> Online Degasser K-5002, 2 channels 1<br />

A2015 WellChrom <strong>HPLC</strong> Online Degasser K-5004, 4 channels 1<br />

Order No. For Preparative <strong>HPLC</strong> Quantity<br />

A2014 WellChrom <strong>HPLC</strong> Online Degasser K-5020, 2 channels<br />

inert version available upon request 1


<strong>HPLC</strong> Mixing Chambers<br />

Dynamic Mixing Chamber, analytical version<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0285 Dynamic Mixing Chamber, stainless steel 1<br />

A0701 Set of spare parts, containing 4 sieves (stainless steel), 6 gaskets 1<br />

A0275 Dynamic Mixing Chamber, titanium 1<br />

A0365 Set of spare parts, containing 4 sieves (PTFE), 6 gaskets 1<br />

A1174 Dynamic Mixing Chamber, PEEK 1<br />

Dynamic Mixing Chamber, preparative version<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0581 Dynamic Mixing Chamber, stainless steel 1<br />

A2515 Optional for extending the mixing volume,<br />

1 intermediate volume element, 4.8 ml, 3 screws 6 x 60 mm 1<br />

A1051 Set of spare parts including 5 gaskets<br />

18.5 mm ID, 21.05 mm AD 1<br />

Description<br />

Suitable for work with high and low<br />

pressure gradient systems. The mixing<br />

chamber made out of titanium enables<br />

metal-free, biocompatible operation.<br />

The mixing chamber made out of PEEK<br />

can be used for biochromatographic<br />

purposes, but has a restricted pressure<br />

stability.<br />

Variable Chamber Volumes<br />

260 µl – ≈ 1,700 µl<br />

Biocompatibility<br />

If the appropriate type of mixing chamber<br />

is used, only titanium or PEEK parts<br />

come into contact with solvents.<br />

Pressure Stability for PEEK<br />

Maximum 120 bar<br />

Dimensions and Weight<br />

80 x 45 x 120 mm (W x H x D) or<br />

80 x 100 x 120 mm (W x H x D),<br />

1.5 kg<br />

Description<br />

Suitable for work with high and low<br />

pressure gradient systems. The mixing<br />

chamber made out of titanium enables<br />

metal-free, biocompatible operation.<br />

The mixing chamber made out of PEEK<br />

can be used for biochromatographic<br />

purposes, but has a restricted pressure<br />

stability.<br />

Chamber Volume<br />

5.9 ml<br />

Biocompatibility<br />

If the appropriate type of mixing chamber<br />

is used, only titanium or PEEK parts<br />

come into contact with solvents.<br />

Maximum Operating Pressure<br />

150 bar<br />

Dimensions and Weight<br />

80 x 130 x 125 mm (W x H x D),<br />

1.6 kg<br />

47


Thermostats<br />

and Flowmeter<br />

Description<br />

Suitable for a permanent monitoring<br />

of flow rates in <strong>HPLC</strong>.<br />

Measuring Range<br />

0.05 – 25 ml/min<br />

Accuracy<br />

±1%<br />

Weight<br />

0.5 kg<br />

Description<br />

The Column Box is ideal for use at<br />

room temperature. It prevents shortterm<br />

temperature fluctuations in chromatographic<br />

separations by covering<br />

<strong>HPLC</strong> columns in dimensions up to<br />

300 x 60 mm ID.<br />

Weight<br />

4.0 kg<br />

Description<br />

Suitable for column thermostatization<br />

above and below room temperature.<br />

Leak detection and a safety function<br />

are integrated. Operates with a Peltierelement<br />

capable of heating and cooling.<br />

Linear and non-linear temperature gradients<br />

can be programmed.<br />

Temperature Range<br />

5–85°C<br />

Temperature Stability and Accuracy<br />

± 0,1 °C, ± 0,2 °C<br />

Heating and Cooling Rate<br />

2 °C/min<br />

Power Supply<br />

100 – 245 V, 50/60 Hz, 100 W<br />

Dimensions<br />

Inside:<br />

90 x 100 x 400 mm (W x H x D)<br />

Outside:<br />

140 x 300 x 470 mm (W x H x D)<br />

48<br />

Flowmeter<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0916 Flowmeter, model 502500, with single-point calibration<br />

at 1 ml/min, with RS-232 interface 1<br />

Column Box<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0253 Column Box 1<br />

Column Thermostat Jetstream<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0527 Column Thermostat Jetstream, 5 – 85 °C,<br />

with 6-Port/2-Channel Injection Valve A1365, stainless steel 1<br />

A0585 Column Thermostat, 5 – 85 °C, injection valve included 1<br />

A1999 Column Thermostat, 5 – 85 °C,<br />

with 6-Port/2-Channel Injection Valve A1366, PEEK 1


<strong>HPLC</strong> <strong>Accessories</strong><br />

<strong>HPLC</strong> Standard Accessory Kit<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1071 <strong>HPLC</strong> Standard Accessory Kit (weight 0.8 kg) 1<br />

Consists of:<br />

Ferrules for Capillaries<br />

1/16”, AD stainless steel 50<br />

1/8”, AD stainless steel 4<br />

Sealing Rings for Capillaries<br />

1/16”, Polymer 100<br />

1/16”, PEEK 20<br />

1/8”, Polymer 5<br />

Bushings for Capillaries<br />

1/16”, short, UNF 10/32, wrench caliber 1/4”, stainless steel 10<br />

1/16”, long, UNF 10/32, wrench caliber 1/4”, stainless steel 10<br />

1/8”, long, M8 x 0,75, wrench caliber 10, stainless steel 3<br />

1/16”, short, UNF 10/32, knurled, polymer 5<br />

1/16”, short, UNF 10/32, with integrated sealing cone,<br />

knurled, polymer 5<br />

Polymer Caps<br />

for closing columns, connectors, and, flow cells<br />

UNF 10/32, knurled, polymer 10<br />

Low Dead Volume Coupling<br />

for 2 capillaries 1/16, stainless steel 5<br />

for 2 capillaries 1/16, polymer 5<br />

for capillaries 1/16” 1/8”, stainless steel 1<br />

T-Connector for 3 Capillaries<br />

1/16”, stainless steel 1<br />

1/16”, polymer 1<br />

Cross-Connector for 4 Capillaries<br />

1/16”, stainless steel 1<br />

1/16”, Polymer 1<br />

DYNASEAL connection system for capillaries<br />

1/16”, short 10<br />

1/16”, long 5<br />

1/8”, short 2<br />

Split-Grooved Clamping Ring for Capillaries<br />

1/16”, stainless steel 30<br />

1/8”, stainless steel 3<br />

Double-Cone Sealing Ring for Capillaries<br />

1/16”, polymer 20<br />

Open-End Wrenches<br />

Set of wrench caliber 1/4” and 5/16” 1<br />

Foreceps 1<br />

Description<br />

<strong>KNAUER</strong> offers a wide range of <strong>HPLC</strong><br />

fittings, connectors, ferrules, and more.<br />

These parts are compatible with commonly<br />

used injection and switching<br />

valves such as Rheodyne, Valco, or<br />

Swagelok. They are compatible for<br />

standard connections for both <strong>HPLC</strong><br />

columns and instruments.<br />

We strongly recommend our DYNASEAL<br />

connection system that is available in<br />

1/16” and 1/8” for analytical and<br />

preparative purposes.<br />

All parts are also available in PEEK.<br />

49


<strong>HPLC</strong> <strong>Accessories</strong><br />

Description<br />

This kit is recommended when ordering<br />

an analytical <strong>HPLC</strong> system for the first<br />

time.<br />

Weight<br />

0.5 kg<br />

Description<br />

This kit is recommended when ordering<br />

an analytical, biocompatible, and inert<br />

<strong>HPLC</strong> system for the first time.<br />

Weight<br />

0.2 kg<br />

50<br />

Start-Up Kit, analytical<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0910 Start-Up Kit, analytical 1<br />

Consists of:<br />

A0131 Capillary, 1/16” AD, 0.25 mm ID, stainless steel 3 m<br />

A0132 Capillary, 1/16” AD, 0.5 mm ID, stainless steel 3 m<br />

A0133 Capillary, 1/16” AD, 0.75 mm ID, stainless steel 3 m<br />

A0129 Set of precut capillaries, 1/16” 8<br />

A0137 Capillary cleaning set 1<br />

A0118 Low dead volume coupling of 2 capillaries, 1/16”, stainless steel 5<br />

A0112 Bushings for capillaries, 1/16”, stainless steel 10<br />

A0110 Ferrules for capillaries, 1/16” 30<br />

A0146 Caps, 1/16”, polymer 1<br />

A0120 T-connector for 3 capillaries, 1/16”, stainless steel 1<br />

A0152 PTFE tubing, 1/16”, 0.45 mm ID 3 m<br />

A0153 PTFE tubing, 2 mm x 1.4 mm ID 3 m<br />

A0108 Set of DYNASEAL connection system, short 2<br />

A0181 Set of DYNASEAL connection system, long 1<br />

A0726 Injection syringe, 100 µl 1<br />

A0809 Pliers for capillaries 1<br />

Start-Up Kit, biocompatible<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1039 Start-Up Kit, biocompatible 1<br />

Consists of:<br />

A0685 Capillary, PEEK, 1/16”, 0.25 mm ID 1.5 m<br />

A0691 Capillary, PEEK, 1/16”, 0.5 mm ID 1.5 m<br />

A0692 Capillary, PEEK, 1/16”, 0.75 mm ID 1.5 m<br />

A0137 Capillary cleaning set 1<br />

A0149 Low dead volume coupling of 2 capillaries, 1/16”, polymer 5<br />

A0585 Bushings for capillaries, 1/16”, short, PEEK 10<br />

A0139 Ferrules for capillaries, 1/16”, PEEK 30<br />

A0146 Caps, 1/16”, polymer 10<br />

A0150 T-connector for 3 capillaries, 1/16”, polymer 1<br />

A0152 PTFE tubing, 1/16”, 0.45 mm ID 3 m<br />

A0153 PTFE tubing, 2 mm x 1.4 mm ID 3 m<br />

A0108 Set of DYNASEAL connection system, short 2<br />

A0181 Set of DYNASEAL connection system, long 1<br />

A0726 Injection syringe, 100 µl 1<br />

A0569 Tube cutter 1


Start-Up Kit, preparative<br />

Ordering Information<br />

Order No. Article Quantity<br />

A1104 Start-Up Kit, preparative 1<br />

Consists of:<br />

A0639 Capillary, 1/8”, 1.6 mm ID 1.5 m<br />

A0640 Capillary, 1/8”, 2.2 mm ID 1.5 m<br />

A0134 Capillary, 1/16”, 1.0 mm ID 3 m<br />

A0873 PTFE tubing, 1/8”, 2 mm ID 3 m<br />

A0732 PTFE tubing, 1/8”, 1.5 mm ID 3 m<br />

A0154 PTFE tubing, 4 mm OD, 3 mm ID 3 m<br />

A0737 Capillary, 1/8”, PEEK, 1.6 mm ID 1.5 m<br />

A0478 Tefzel tubing, 1/8”, 1.6 mm ID 3 m<br />

A0644 DYNASEAL connection system for capillaries 1/8”, stainless steel 1<br />

A0830 Bushing for capillaries 1/8”, stainless steel 1<br />

A2511 T-connector for 3 capillaries 1/8”, short, stainless steel 1<br />

A2512 Low dead volume coupling for 2 capillaries 1/8”, stainless steel 5<br />

A2513 Low dead volume coupling for capillaries 1/16” 1/8”, stainless steel 1<br />

A0117 Low dead volume coupling for 2 capillaries 1/16”, stainless steel 1<br />

A0736 Set of DYNASEAL connection systems, 1/8”, long 1<br />

A0232 Sealing ring for capillaries 1/8”, polymer 10<br />

A0874 Ferrules for capillaries 1/8”, stainless steel 10<br />

A1239 Split-grooved clamping ring for capillaries 1/8” 4<br />

X0003 Set of two open-end wrenches, wrench caliber 1/4” and 5/16” 2<br />

X0030 Open-end wrench, wrench caliber 8/10” 2<br />

A0573 Luer-Lock syringe, glass, 10 ml 1<br />

A0734 Caps, 1/8”, polymer 10<br />

Filters for Sample Preparation<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0950 All glass vacuum unit 1<br />

A0951 PTFE membrane filter, 47 mm ∅, pore size 0.45 µm 100<br />

A0917 Membrane filter made out of regenerated cellulose,<br />

47 mm ∅, pore size 0.45 µm 100<br />

Description<br />

Recommended when ordering a preparative<br />

<strong>HPLC</strong> system for the first time.<br />

Weight<br />

0.9 kg<br />

Description<br />

Recommended for sample preparation.<br />

51


<strong>HPLC</strong> <strong>Accessories</strong><br />

Description<br />

<strong>KNAUER</strong>’s sample loops are suitable for<br />

all types of <strong>HPLC</strong> systems. Sample loops<br />

made out of PEEK will be delivered with<br />

our DYNASEAL connection system for<br />

capillaries 1/16”.<br />

Individual sizes available upon request.<br />

We recommend using the loop filling<br />

port if the injection syringe cannot be<br />

inserted into the injection port.<br />

Description<br />

Suitable for 1/16” and 1/8” connections.<br />

Useful for full and partial loop filling.<br />

The 11 ml and 45 ml sample loops<br />

consist of an empty stainless steel<br />

column with an internal piston.<br />

Low peak broadening. Applicable for<br />

flow rates exceeding 1 ml/min.<br />

Description<br />

Glass syringes are suitable for all standard<br />

<strong>HPLC</strong> injection valves.<br />

52<br />

Sample Loops, analytical<br />

Ordering Information<br />

Sample Loops, stainless steel<br />

Order No. Sample Volume Quantity<br />

A0331 5 µl 1<br />

A0561 10 µl 1<br />

A0562 20 µl 1<br />

A0836 30 µl 1<br />

A0563 50 µl 1<br />

A0837 75 µl 1<br />

A0564 100 µl 1<br />

A0565 200 µl 1<br />

A0566 500 µl 1<br />

A0567 1,000 µl 1<br />

A0568 2,000 µl 1<br />

Sample Loops, preparative<br />

Ordering Information<br />

Order No. Sample Loops Quantity<br />

A1159 1/8’’, volume up to 11 ml 1<br />

A1160 1/8’’, volume up to 45 ml 1<br />

A1054 1/16”, volume up to 11 ml 1<br />

A1055 1/16”, volume up to 45 ml 1<br />

A1043 1/8”, volume up to 1 ml, stainless steel 1<br />

A1110 1/8”, volume up to 1 ml, PEEK 1<br />

A1044 1/8”, volume up to 2 ml, stainless steel 1<br />

A1111 1/8”, volume up to 2 ml, PEEK 1<br />

Injection Syringes<br />

Ordering Information<br />

Order No. Sample Volume Quantity<br />

A0723 10 µl 1<br />

A0724 25 µl 1<br />

A0725 50 µl 1<br />

A0726 100 µl 1<br />

Sample Loops, PEEK<br />

Order No. Sample Volume Quantity<br />

A1058 10 µl 1<br />

A1059 20 µl 1<br />

A1060 50 µl 1<br />

A1061 200 µl 1<br />

A1057 500 µl 1<br />

Loop Filling Port<br />

Order No. Article Quantity<br />

A0555 Loop filling port 1<br />

Order No. Sample Volume Quantity<br />

A0727 250 µl 1<br />

A0728 500 µl 1<br />

A0729 1,000 µl 1<br />

A0730 2,500 µl 1


Capillaries, stainless steel<br />

Ordering Information<br />

Order No. OD (inch) ID (mm) Length (cm) Quantity<br />

A0130 1/16” 0.10 300 1<br />

A0131 1/16” 0.25 300 1<br />

A0132 1/16” 0.50 300 1<br />

A0133 1/16” 0.70 300 1<br />

A0134 1/16” 1.00 300 1<br />

A0123 1/16” 0.10 10 10<br />

A0124 1/16” 0.10 20 10<br />

A0125 1/16” 0.10 30 10<br />

A0126 1/16” 0.25 10 10<br />

A0127 1/16” 0.25 20 10<br />

A0128 1/16” 0.25 30 10<br />

A0639 1/8” 1.60 150 1<br />

A0640 1/8” 2.20 150 1<br />

Tools for Capillaries, stainless steel<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0137 Capillary cleaning set 1<br />

A0809 Pliers for capillaries 1<br />

Capillaries, PEEK<br />

Ordering Information<br />

Order No. OD (inch) ID (mm) Length (cm) Quantity<br />

A0685 1/16” 0.25 150 1<br />

A0691 1/16” 0.50 150 1<br />

A0692 1/16” 0.70 150 1<br />

A0737 1/8” 1.60 150 1<br />

Description<br />

Resistant capillaries made out of stainless<br />

steel for all <strong>HPLC</strong> connections.<br />

Description<br />

Tools to keep your capillaries in »shape«.<br />

Description<br />

Suitable for biochromatography.<br />

Metal-free PEEK capillaries consist of<br />

polyether-ether-ketone that show a<br />

pressure stability of up to 400 bar<br />

depending on the inner diameter.<br />

Don’t forget to take advantage of our<br />

DYNASEAL connection system when<br />

working with PEEK capillaries.<br />

53


<strong>HPLC</strong> <strong>Accessories</strong><br />

Description<br />

Tefzel tubings consist of perfluorinated<br />

hydrocarbons. They are flexible, inert,<br />

and gas tight. Pressure stability reaches<br />

up to 200 bar depending on the inner<br />

diameter.<br />

Description<br />

PTFE tubings consist of perfluorinated<br />

hydrocarbons. They are flexible, biocompatible,<br />

and gas tight.<br />

Description<br />

Cuts all flexible plastic tubes, particularly<br />

suitable for capillaries made out of<br />

PEEK.<br />

54<br />

Tefzel Tubings<br />

Ordering Information<br />

Order No. OD (inch) ID (mm) Length (cm) Quantity<br />

A0182 1/16” 0.25 – 0.30 300 1<br />

A0183 1/16” 0.70 300 1<br />

A0478 1/8” 1.60 300 1<br />

PTFE Tubings<br />

Ordering Information<br />

Order No. OD (inch) ID (mm) Length (cm) Quantity<br />

A0152 1.6 (1/16”) 0.45 300 1<br />

A0153 2 1.45 300 1<br />

A0732 3.2 (1/8”) 1.5 300 1<br />

A0873 3.2 (1/8”) 2.00 300 1<br />

A0154 4 3.00 300 1<br />

Tube Cutter, Ferrules, and Sealing Rings<br />

Ordering Information<br />

Order No. Tube Cutter Quantity<br />

A0569 Tube cutter 1<br />

Order No. Ferrules for capillaries Quantity<br />

A0110 1/16”, stainless steel 30<br />

A0111 1/16”, stainless steel 100<br />

A0874 1/8”, stainless steel 10<br />

Order No. Sealing Rings for capillaries Quantity<br />

A0139 1/16”, polymer 30<br />

A0140 1/16”, polymer 100<br />

A0232 1/8”, polymer 10<br />

A1062 1/16”, PEEK 10<br />

A1063 1/8”, PEEK 10


Couplings, T-Connectors, and Cross Connectors<br />

Ordering Information<br />

Low Dead Volume Couplings, stainless steel<br />

Order No. for connecting: Quantity<br />

A0117 2 capillaries 1/16” 1<br />

A0118 2 capillaries 1/16” 5<br />

A0119 2 capillaries 1/16” 25<br />

A2512 2 capillaries 1/8” 5<br />

A2513 2 capillaries 1/16” 1/8” 1<br />

Low Dead Volume Couplings, polymer<br />

Order No. for connecting: Quantity<br />

A0148 2 capillaries, 1/16” 1<br />

A0149 2 capillaries, 1/16” 5<br />

T-Connector, stainless steel<br />

Order No. for connecting: Quantity<br />

A0120 3 capillaries 1/16” 1<br />

A2511 3 capillaries 1/8” 1<br />

T-Connector, polymer<br />

Order No. for connecting: Quantity<br />

A0150 3 capillaries 1/16” 1<br />

Cross-Connector, stainless steel<br />

Order No. for connecting: Quantity<br />

A0121 4 capillaries 1/16” 1<br />

A1096 4 capillaries 1/8” 1<br />

Cross-Connector, stainless steel<br />

Order No. for connecting: Quantity<br />

A2514 3 capillaries of 1/16” and 1 capillary of 1/8” 1<br />

Cross-Connector, polymer<br />

Order No. for connecting: Quantity<br />

A0151 4 capillaries of 1/16” 1<br />

Description<br />

All parts made out of polymer consist<br />

of PETP (Arnite) if not mentioned<br />

otherwise.<br />

55


<strong>HPLC</strong> <strong>Accessories</strong><br />

Description<br />

All bushings have inch threading (UNF)<br />

and are available with short and long<br />

heads. The long head bushings are<br />

recommended when tight connections<br />

are required.<br />

Ferrules are slipped over the capillary,<br />

deformed during tightening, and cannot<br />

be removed afterwards. Thus, the<br />

connection is sealed.<br />

Description<br />

56<br />

Bushings and Caps (Blind Fittings)<br />

Ordering Information<br />

Order No. Bushings for Capillaries Quantity<br />

A0112 1/16’’, short, UNF 10/32, SW 1/4’’, stainless steel 10<br />

A0113 1/16’’, short, UNF 10/32, SW 1/4’’, stainless steel 25<br />

A0115 1/16’’, long, UNF 10/32, SW 1/4’’, stainless steel 3<br />

A0116 1/16’’, long, UNF 10/32, SW 1/4’’, stainless steel 10<br />

A0830 1/8’’, M8 x 1, SW 10, stainless steel 10<br />

A0141 1/16’’, short, UNF 10/32, knurled, polymer 10<br />

A0142 1/16’’, short, UNF 10/32, knurled, polymer 30<br />

A0143 1/16’’, short, UNF 10/32, knurled, polymer 100<br />

A0144 1/16’’, long, UNF 10/32, knurled, polymer 10<br />

A0145 1/16’’, short, UNF 10/32, with double-cone sealing,<br />

knurled, polymer 10<br />

A0733 1/8’’, short, UNF 10/32, M8 x 1, with sealing ring,<br />

knurled, polymer 10<br />

A0584 1/16’’, UNF 10/32, PEEK 10<br />

Order No. Caps (blind fittings) Quantity<br />

A0146 1/16’’, short, UNF 10/32, polymer 10<br />

A0147 1/16’’, short, UNF 10/32, polymer 30<br />

A0734 1/8’’, M8 x 1, polymer 10<br />

A0582 1/16’’, short, UNF 10/32, knurled, polymer 10<br />

DYNASEAL Connection System<br />

Ordering Information<br />

Order No. Bushings for Capillaries Quantity<br />

A1021 1/16”, short 10<br />

A1064 1/16”, long 5<br />

A1067 1/8”, short 4<br />

A0735 1/8”, long 4<br />

Order No. Split-Grooved Clamping Rings Quantity<br />

A0484 1/16” 4<br />

A1239 1/8” 4<br />

Order No. Sealing Rings Quantity<br />

A0139 1/16”, polymer 30<br />

A0140 1/16”, polymer 100<br />

A1062 1/16”, PEEK 10<br />

A0232 1/8”, polymer 10<br />

A1063 1/8”, PEEK 10<br />

Order No. Double-Cone Sealings Quantity<br />

A1022 1/16”, polymer 10<br />

A1070 1/16”, PEEK 10


DYNASEAL Connection System<br />

Ordering Information – System –<br />

Order No. Article Quantity<br />

A0108 1/16”<br />

Short head bushings 4<br />

Split-grooved clamping rings 4<br />

Sealing rings 8<br />

A0181 1/16”<br />

Long head bushings 3<br />

Split-grooved clamping rings 3<br />

Sealing rings 4<br />

A1020 1/16”<br />

Short head bushings 10<br />

Double-cone sealings 10<br />

A1069 1/16”<br />

Long head bushings 5<br />

Double-cone sealings 5<br />

A0736 1/8”, M8 x 0.1<br />

Long head bushings 4<br />

Split-grooved clamping rings 4<br />

Sealing rings 8<br />

A0644 1/8”, M8 x 1<br />

Short head bushings 4<br />

Split-grooved clamping rings 4<br />

Sealing rings 8<br />

Description<br />

The DYNASEAL connection system<br />

connects capillaries made out of stainless<br />

steel and PEEK, as well as PTFE and<br />

Tefzel tubings with saftey and low dead<br />

volumes. It allows maintenance-free<br />

operation and provides a long life.<br />

Suitable for UNF-threads of type 10/32.<br />

The system consists of a bushing, a splitgrooved<br />

clamping ring, and a polymer<br />

sealing. The split-grooved clamping<br />

ring and polymer sealing are slipped<br />

over the capillary »back to back«, while<br />

the bushing tightens all parts. Thus,<br />

leak-free operation is made possible.<br />

DYNASEAL connections are pressure<br />

stable up to 450 bar.<br />

DYNASEAL can be optionally used with<br />

double-cone sealings made out of PEEK<br />

or stainless steel. In this case, pressure<br />

stability is accordingly reduced to 150 bar<br />

(PEEK) and 350 bar (polymer).<br />

DYNASEAL is adaptable in new conditions<br />

such as variable bore depths or<br />

detector connections because it is<br />

mobile and reuseable.<br />

Important Note<br />

The DYNASEAL connection system<br />

is available for capillaries with 1/16”<br />

(analytical <strong>HPLC</strong>) and 1/8” (preparative<br />

<strong>HPLC</strong>).<br />

In general, to connect <strong>KNAUER</strong>, Rheodyne,<br />

or other injection systems; the<br />

long head bushings can be delivered<br />

upon request.<br />

57


<strong>HPLC</strong> <strong>Accessories</strong><br />

Description<br />

The Column Inlet Filter can be installed<br />

between the injection system and the<br />

column. Column inlet filters protect<br />

the column from particle contamination<br />

caused by sealing material (i. e. pump<br />

pistons). We recommend adding a filter<br />

after the column. This prevents contamination<br />

of the detector cell. Inlet filters<br />

are available in stainless steel and<br />

PEEK.<br />

Description<br />

Ready-to-use filtration units for ultrapurification<br />

of small sample volumes.<br />

The chemically resistant polypropylene<br />

housing has been designed to achieve<br />

a maximum sample yield with a high<br />

retention time. Backflow/overflow of<br />

the filtrate is effectively avoided with<br />

elongated Spike and Luer outlets.<br />

58<br />

Column Inlet Filters<br />

Ordering Information<br />

Order No. Article Quantity<br />

A0109 Column Inlet Filter, stainless steel 1<br />

A0015 Set of spare parts for A1090, includes:<br />

6 sieves (3 µm), 6 sieves (7 µm), 12 glass filters, 6 PTFE gaskets 1<br />

A0138 Set of open-end wrenches, wrench caliber 1/4” and 5/16” 2<br />

A0573 Luer-Lock glass syringe, 10 µl 1<br />

A0653 Luer-Lock glass syringe, 20 µl 1<br />

Syringe Filtration Units<br />

Ordering Information<br />

Polypropylene-reinforced PTFE (hydrophobe)<br />

Pore Size Dead Volume � Area<br />

Order No. Article µm µl mm cm 2 Quantity<br />

A1258 Minisart SRP4 0.45 1 4 0.10 50<br />

A1259 Minisart SRP4 0.45 1 4 0.10 500<br />

A0958 Minisart SRP15 0.45 10 15 1.70 50<br />

A1264 Minisart SRP15 0.45 10 15 1.70 500<br />

A0953 Minisart SRP15 0.20 10 15 1.70 50<br />

A0954 Minisart SRP15 0.20 10 15 1.70 500<br />

A0956 Minisart SRP25 0.20 100 25 4.80 50<br />

A0957 Minisart SRP25 0.45 100 25 4.80 50<br />

A1262 Minisart SRP25 0.45 100 25 4.80 500<br />

Cellulose (hydrophile)<br />

Pore Size Dead Volume � Area<br />

Order No. Article µm µl mm cm2 Quantity<br />

A1260 Minisart RC4 0.45 5 4 0.07 50<br />

A1261 Minisart RC4 0.45 5 4 0.07 500<br />

A1265 Minisart RC15 0.45 10 15 1.70 50<br />

A0960 Minisart RC15 0.45 10 15 1.70 500<br />

A0961 Minisart RC25 0.20 150 25 4.80 500<br />

A1263 Minisart RC25 0.45 150 25 4.80 50<br />

A0962 Minisart RC25 0.45 150 25 4.80 500


Terms of Delivery<br />

Terms of Delivery<br />

Our general delivery and payment conditions are valid as follows:<br />

Our deliveries follow ex works. As soon as the merchandise leaves our factory accidental<br />

loss, damage, destruction, or deterioration is at the buyer’s own risk. The guarantee<br />

is valid for one year with the exception of cullet, expendable items such as lamps,<br />

columns, seals, valves, and damage due to clogging or jamming. This guarantee<br />

strictly applies to osmometers and devices used in liquid chromatography.<br />

The delivered merchandise will remain our property until payment has been made,<br />

received in full, and all claims have been met. We reserve the right for any modifications<br />

in technical advancement.<br />

Address<br />

Wissenschaftliche Gerätebau<br />

Dr. Ing. Herbert Knauer GmbH<br />

Hegauer Weg 38<br />

D-14163 Berlin (Zehlendorf)<br />

Germany<br />

Telephone: +49 (0)30 80 97 27- 0<br />

Fax: +49 (0)30 8 01 50 10<br />

E-mail: info@knauer.net<br />

Internet: www.knauer.net<br />

Bank Information<br />

� Commerzbank AG, Berlin<br />

Bank code number: 100 400 00<br />

Account number: 65 02 900<br />

� Berliner Bank AG, Berlin<br />

Bank code number 100 200 00<br />

Account number 99 80 22 52 01<br />

59


Conditions of Sale<br />

Conditions of Sale<br />

1. Definition of Terms<br />

The following terms and conditions apply to every order received<br />

by us. This is especially applicable in case of contradictory buying<br />

conditions of sale. Exceptions are only valid when confirmed<br />

by us in writing.<br />

Purchase orders are only binding if confirmed by us in writing.<br />

2. Payment<br />

Domestic deliveries are payable, net, within 30 days of invoice<br />

date or in advance. Deductions are not allowed.<br />

Foreign deliveries must be paid by irrevocable letter of credit or<br />

in advance. All bank and transfer fees must be paid by the<br />

customer. The maturity date passed the customer is in default<br />

even without an additional reminder. Upon delay interest of five<br />

percent above the German Federal Bank discount rate will be<br />

added to the purchase price, if we do not prove a higher damage<br />

or the customer proves a lower damage.<br />

Payments are due irrespective of an eventual notice of defect,<br />

except such defects which are evidently justified.<br />

3. Delivery<br />

Delivery dates are not binding. Delay in delivery requires a<br />

written reminder and an adequate additional period of grace set<br />

by the customer, after which customer may rescind the contract.<br />

Claims for damages of any kind are excluded.<br />

4. Claims<br />

Condition for any warranty claim is the immediate inspection of<br />

the goods upon delivery, complaint towards and damage assessment<br />

together with the carrier, and an immediate written complaint<br />

to us. The complaint must be made within three workdays<br />

in case of visible defects or losses.<br />

5. Risk Liability<br />

Delivery is made at the customer’s own risk. As soon as the<br />

goods leave our plant the risk of accidental loss, destruction or<br />

deterioration passes to the customer.<br />

6. Guarantee<br />

Our warranty for osmometers and liquid chromatography instruments<br />

is limited to one year, excluding glass breakage,<br />

damages due to stoppage and consumable materials such as<br />

membranes, light bulbs, columns, bushings, gaskets and valves.<br />

Our warranty is limited to repair or replacement at no costs except<br />

if we have guaranteed certain characteristics explicitly and<br />

in writing. Transportation costs are borne by the customer. In<br />

case a repair or eventual replacement is also defective the customer<br />

may rescind the contract or may claim a reduction in<br />

price.<br />

Warranty claims are barred if the customer denies us repair or<br />

replacement of the defective product within a reasonable<br />

period of time not exceeding three months counting from the<br />

date of the written complaint.<br />

We are not liable for defects originating after the passing of the<br />

risk, for defects originating in improper or careless handling of<br />

the goods by the customer, or for defects caused by inappropriate<br />

or not permitted operating supplies.<br />

We are liable for monetary compensation only for damages<br />

caused by the absence of expressly and in writing warranted<br />

characteristics, for damages caused by us or persons employed<br />

60<br />

by us, either intentionally or – in case of a breach of condition of<br />

the contract – negligently, otherwise only in case of gross negligence.<br />

Our liability for damages is limited to direct damages except in<br />

case a specific warranty was given to cover the customer also<br />

against indirect damages. We are not liable for advice given.<br />

Liability according to the stipulations of the German Law on<br />

Product Liability remains unaffected.<br />

7. Property Rights<br />

The ownership of the goods shall remain with us until payment<br />

in full for all our claims resulting from our business relation is<br />

received. In case of improper treatment of the goods or in case<br />

of default we may demand the return of the delivered goods.<br />

Towards merchants this demand entails resignation of the contract<br />

only if we declare it explicitly.<br />

Resalers are allowed to sell the goods to third parties in due<br />

course of the business. The customer herewith assigns his resale<br />

claims against third parties to us.<br />

8. Export<br />

<strong>Instruments</strong> and products delivered by us may not be exported<br />

to a country other than of the customer’s headquarters without<br />

our prior written permission.<br />

9. Place of Settlement and Court of Jurisdiction<br />

If the customer is a merchant the place of performance is Berlin.<br />

Proper venue for all claims is the competent local court at our<br />

principal place of business. We reserve the right to sue the<br />

customer at his principal place of business.<br />

This agreement shall be governed by the laws of the Federal<br />

Republic of Germany excluding the UN-Convention on the<br />

International Sale of Goods (CISG).


Please ask for our<br />

Flyers for individual Modules ...<br />

The WellChrom Series<br />

of Analytical <strong>HPLC</strong> Pumps<br />

Wissenschaftliche Gerätebau<br />

Dr. Ing. Herbert Knauer GmbH<br />

Hegauer Weg 38<br />

D-14163 Berlin, Germany<br />

Telephone: +49 (0)30/80 9727- 0<br />

Telefax: +49 (0)30/8 01 50 10<br />

E-Mail: info@knauer.net<br />

Internet: www.knauer.net<br />

Photometric<br />

Detection Systems<br />

The WellChrom Series<br />

of Autosamplers Preparative Pump K-1800<br />

<strong>KNAUER</strong> systems are manufactured based on the<br />

latest technology and over 40 years of experience.<br />

Our product and sales managers are specialized in<br />

configuring and / or adjusting all <strong>KNAUER</strong> systems.<br />

Dealers now located in over 50 countries!<br />

<strong>HPLC</strong> Autosampler K-3800<br />

Our customers are, therefore, equipped with excellent<br />

products and services. With expertise and<br />

patience we are committed to assisting your every<br />

need.<br />

Your local dealer:<br />

<strong>KNAUER</strong> ChromGate ®<br />

Chromatographic System<br />

Vapour Pressure<br />

Osmometer K-7000 <strong>HPLC</strong> Columns<br />

KN 08/01/06.2001/8.5 Weselmann Berlin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!